This article provides manuals and contact information for Alka-Viva water softeners.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Editor/Publisher - See WHO ARE WE?
Below is a description of the AlkaViva brand water conditioner from AquaBreeze, https://aquabreezestore.com/, retrieved 2022/01/.20
The Salt-Free Softener Technology
The principle behind the EnviroSoft Technology is relatively simple: it changes scaling calcium into non-scaling calcium.
Water becomes hard or “scaling” when the calcium and carbonic acid are out of balance. EnviroSoft Media helps return hard water chemistry from this state of imbalance towards proper balance – just like in soft water. As nature intended.
In other words, minerals are neutralized so they don’t stick to surfaces, not removed from your water using harmful chemicals.
The EnviroSoft Media is made up of inert NSF-certified polymer beads that work in a fluidized bed - meaning the beads move around and bump into each other.
The surface of each inert bead looks like a mini-template of organized holes, technically referred to as “nucleation sites”.
These sites act as a catalyst to change scaling calcium into nano-sized crystal structures that are able to absorb minerals readily, yet stable enough to not attach themselves to the surfaces of your plumbing or appliances.
The calcium crystals eventually release from the templates into the water stream making EnviroSoft self-regenerating – meaning you never have to replace the media.
Nothing is added to the water. Back in the water stream, the calcium crystals become templates (or “seed” crystals) themselves, and can perform the same function just like the media.
This is especially important with hot-water appliances like your coffee maker or hot water heater because heating water increases its scale potential. However, the seed crystals are able to absorb the calcium that would otherwise form scale.
So while EnviroSoft does not technically soften the water, it also doesn’t come with the ongoing hassle, expense or eco-issues that salt-softeners create. At the same time, EnviroSoft conditions your water to protect your plumbing and appliances.
EnviroSoft also leaves in the healthy minerals (softeners do NOT). EnviroSoft is eco-friendly, needs no maintenance, never has to be replaced and is hassle-free and cost effective.
...
Continue reading at WATER SOFTENER ADJUSTMENT & CONTROLS, or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
Alka-Viva WATER SOFTENERS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.