Photograph of Allergenco Mark III Impaction Air Sampler Mold Mold Concentration Burst Error in Mold Tests

Mold concentration bursts impact on airborne mold count results:

Here we explain what Mold Concentration Bursts are and how mold concentration bursts cause Error in Mold Tests when Air Sampling.

This document is a brief tutorial which provides information about the accuracy of and sources of errors in tests for the level of allergenic and toxic mold in residential buildings:

Are spore counts valid? Are mold culture tests and mold swab tests valid? These critical questions are discussed in this article series.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?

Concentration Bursts of Mold Spores Cause Variation in Indoor or Outdoor Mold Level Counts

Photograph of air trace under moldy tableACGIH Bioaerosols: Assessment and Remediation states [section 1.2.3]:

Some organisms and sources release aerosols as 'concentration bursts' which may only rarely be detected by limited grab sampling and may be masked in measurements of long-term average concentrations.

Nevertheless, such episodic bioaerosol releases may produce significant health effects. -- thanks to S. Flappan for suggesting this citation.

[Click to enlarge any image]

Spores are not always airborne during sampling:

Mold spores may not be in interior air at the time of the sample but may be present in high levels at other times.

Particle level in air varies very continuously as a function of temperature, humidity, size, mechanical disturbance, HVAC operation, use of fans and vacuum cleaners, and other factors as simple as foot traffic through a building.

Concentration bursts of mold spores:

An example of a concentration burst of Aspergillus sp. spores occurred during our inspection and monitoring of a college library with many moldy books in its basement. Initially, though there was a large area of visible green mold (Aspergillus sp.) on many books on shelves in the library basement, while conditions there were still quite damp (humidity 65-75% RH) the airborne Aspergillus sp. spore levels were rather low.

But when the college brought in an "expert" who installed commercial dehumidifiers (without cleaning or removing the mold) the airborne Aspergillus sp. skyrocketed.

As the humidity dropped the fungus responded by releasing spores.


...

Continue reading at ACCURACY OF AIR TESTS for MOLD or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Recommended Articles

Suggested citation for this web page

AIRBORNE MOLD SPORES CONCENTRATION BURSTS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to MOLD CONTAMINATION & REMEDIATION

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia


Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.

Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification
when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.


Comment Form is loading comments...

IF above you see "Comment Form is loading comments..." then COMMENT BOX - countable.ca / bawkbox.com IS NOT WORKING.

In any case you are welcome to send an email directly to us at InspectApedia.com at editor@inspectApedia.com

We'll reply to you directly. Please help us help you by noting, in your email, the URL of the InspectApedia page where you wanted to comment.

Citations & References

In addition to any citations in the article above, a full list is available on request.



ADVERTISEMENT