Wood Fired Heating Furnace & Boiler Defects List & Home Inspection Education
Wood heaters & wood burning appliance inspection defects list:
This article lists significant wood fired heating system defects, definitions, and home inspection education topics. This article series, beginning at BUILDING DEFECTS LISTS, provides lists of common building defects and basic defect knowledge that also outline recommended curriculum content for home inspector education. The building defects and inspection points listed in these articles also guide homeowners and home buyers to building areas that merit careful attention and often point areas of safety concern or important maintenance and repair tasks.
Readers should see WOOD BURNING HEATERS FIREPLACES STOVES and also Woodstove Safety for our complete list of articles on this topic. Also see HOME & BUILDING INSPECTORS & INSPECTION METHODS. Use the Search Box at the top or bottom of these pages to find in-depth information about building, energy savings, and indoor environment inspection, diagnosis and repair at this website.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
These curriculae and building defect lists are based on smilar curriculum documents first prepared by Joe Scaduto, an ASHI member who prepared course material for Northeastern University's Building Inspection Certificate program in 1988, subsequently by DF, InspectApedia's editor, for New York University ca 1988 and later, with others, recommended to ASHI, the American Society of Home Inspectors. ASHI did not adopt this material though currently that association as well as others offer extensive HOME INSPECTOR EDUCATION material.
The curriculum and lists of defects are informed by additional analysis of the process of home inspection that was developed beginning Calgary, AB for Canadian and U.S. home inspector education and certification examinations in 1997 and later. Other early contributors to home inspection education in the U.S. and Canada include Dr. Jess Aronstein, Alan Carson, Mike Casey, Mark Cramer, John Cox, Dwight Barnett, Douglas Hansen, Rick Heyl, Larry Hoytt, Bill Merrill, Kevin O'Malley, Dennis Robitalille, Keith Peddie, Pat Porzio, Roger Robinson.
• Combustible clearances
• Mechanical damage
• Missing components
• Not listed or certified
• Obstructed air intakes
• Rust
• Scorching
• Inadequate combustion air
• Creosote deposits
• Extends too far into chimney
• Improper material (galvanized)
• Inadequate combustible clearance
• Poor support
• Poor slope
• Poor connection to chimney
• Poor manifolding
• Poor connections
• Rust
• Too long
• Too big or too small
• Inoperative valve or motor
• Poor adjustment
• Running continuously
• Warped or stuck
• Inoperative
• Noisy or vibrating
• Deteriorated brick
• Dirty combustion chamber
• Poor door seal
• Warped door
• Warped or cracked metal firebox
• Warped grate
• Not level
• Damaged
• Anticipator problems
• Loose
• Dirty
• Poor adjustment, calibration
• Poor location
• Dirty
• Fan belt loose, worn or damaged
• Inoperative
• Noisy
• Overheating
• Poorly secured
• Rust
• Too small
• Unbalanced or vibration
• Cracks or holes
• Rust
• Soot or creosote deposits
• Dirty
• Improperly wired
• Mechanical damage
• Rusting
• Missing cover
• Scorching
• Set wrong or defective
• Inadequate draft air
• Inoperative
• Missing
• Poorly adjusted
• Rusting
• Spillage
• Missing
• Scorching
• Set wrong
• Set wrong or defective
• Add-on furnace not downstream from other
• Combustible clearances
• Combustible return ducts
• Dirty ducts
• Disconnected ducts
• Ducts obstructed or collapsed
• Leaks
• No air or weak airflow
• Poor register location
• Registers obstructed, painted shut or damaged
• Registers or grills in garages
• Rust
• Too few return grills
• Uninsulated ducts
• Wire or pipe in duct
• Combustible clearances
• Mechanical damage
• Missing components
• Not listed or certified
• Obstructed air intakes
• Rust
• Scorching
• Inadequate draft air
• Inoperative
• Cracks or holes
• Rust
• Soot or creosote deposits
• Missing
• Poorly adjusted
• Inadequate combustion air
• Rusting
• Spillage
• Creosote deposits
• Extends too far into chimney
• Inadequate combustible clearance
• Improper material (galvanized)
• Poor support
• Poor connection to chimney
• Poor slope
• Poor manifolding
• Poor connections
• Rust
• Too long
• Too big or too small
• Inoperative valve or motor
• Poor adjustment
• Warped or stuck
• Inoperative
• Noisy or vibrating
• Deteriorated brick
• Dirty combustion chamber
• Poor door seal
• Warped door
• Warped or cracked metal firebox
• Warped grate
• Inoperative
• Set incorrectly
• Anticipator problems
• Damaged
• Dirty
• Loose
• Not level
• Poor adjustment or calibration
• Poor location
• Inoperative
• Leaking
• Inoperative
• Inoperative
• Leaks
• Inoperative
• Leaks
• Rust
• Missing
• Leaking
• Inoperative
• Inoperative
• Set incorrectly
• Installed backwards
• Missing
• Leaking
• Inoperative
• Installed backwards
• Set too low
• Leaking
• Missing
• Leaks
• Poor discharge location for open tank
• Poor location for tank
• Rust
• Too small
• Waterlogged
• Hot
• Inoperative
• Leaks
• Noisy
• Leaks
• No insulation
• Poor support
• Rust
• Too small
• No piped extension
• Pipe too small
• Pipe threaded, capped or corroded at bottom
• Pipe dripping or leaking
• Poor location
• Set wrong
• Wrong size
• Balancing valve problems
• Damaged baseboard fins
• Leaks
• Missing
• Obstructed airflow
• Poor location
• Rust
• Too small
• Door gasket – loose, missing,
brittle or incomplete
• Door loose, warped or poorly fit
• Leakage
• Unsteady or not well secured
• Warped, cracked or gaps
• Multiple appliances connected to chimney
• Pieces poorly connected
• Catalytic combuster clogged
• Combustible clearances
– Floor
– Side and rear walls
– Front walls
– Ceiling
• Creosote deposits
• Firebrick cracked, crumbling or incomplete
• Owner’s manual missing
• Warped, cracked or creosote deposit
• Improper clearance Reduction system installation
• Inadequate combustible clearance
• Creosote deposits
• Excess length
• Goes through walls or closets
• Heat reclaimer installed
• No expansion provision
• Poor slope
• Poor connection to chimney
• Seams on bottom
• Too many elbows
• Wrong material
• Cracked
• Deteriorating concrete, masonry or mortar
• Heaved
• Leakage
• Settled
• Frame loose
• Damper or frame rusted
• Inoperative
• Missing
• Undersized
• Obstructed
• Too low
• Too small
• Debris
• Excess slope
• Missing
• Rust (metal firebox)
• Uneven slope
• Walls not smooth
• Evidence of overheating
• Gaps or cracks
• Inappropriate material
• Settled
• Too thin
• Too small
• Wood forms not removed
• Settled (gap at wall)
• Combustible clearances
• Cracked
• Evidence of overheating
• Loose
• Settled (gap at wall)
• Cracked masonry or refractory
• Designed for coal
• Deteriorated, missing or loose masonry or mortar
• Draft suspect
• Inappropriate materials
• Lintels rusted, sagging or loose
• Rust out, burn out, buckled or cracked metal firebox
• Too shallow
• Too thick
• Cracked or broken glass
• Frame warped
• Inappropriate installation
• Frame rust
• Inoperative
• Ash dump missing
• Cleanout door too close to combustibles
• Cleanout door missing
• Floor below cleanout door
• Wood forms not removed
• Obstructed intakes or outlets
• Rusted out steel ducts/boxes - air leaks, loss of control, fire hazards, smoke contamination
• Fan inoperative
• Damper stuck
• Damper missing
• Disconnected
• Hood and screen at firebox missing, damaged or loose
• Inadequate combustible clearance
• Inappropriate material
• Intake not weathertight
• Intake not screened
• Intake poor location
• Rust
• Uninsulated
• Inadequate seal at firebox wall or floor
• Inadequate combustible clearance
• Pipe obstructed
• Gas leak
• Missing or improperly located gas shutoff valve
• Inadequate combustible clearance
Also see HOME & BUILDING INSPECTORS & INSPECTION METHODS. Use the Search Box at the top or bottom of these pages to find in-depth information about building, energy savings, and indoor environment inspection, diagnosis and repair at this website. Watch out: these inspection lists do not list all possible defects for the systems discussed, and not all home or building inspectors will examine all of the items listed here. CONTACT us to suggest corrections or additions to articles at this website.
...
Continue reading at WOOD BURNING HEATERS FIREPLACES STOVES and also Woodstove Safety, or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
DEFECTS LIST - HEAT, WOOD APPLIANCE at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Or see
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Or see
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
In addition to any citations in the article above, a full list is available on request.