HB Smith & AO Smith & Smith Boilers
Manuals, parts lists, wiring diagrams for HB Smith boilers & Smith Boilers.
We include immediate downloads of example installation & repair manuals and wiring diagrams for air conditioners, heat pumps, and heating equipment from a variety of manufacturers as well as contact information to obtain the exact manual or wiring diagram for your unit.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
Free Furnace, Heat Pump, Air Conditioner Installation & Service Manuals, Wiring Diagrams, Parts Lists
Photo: even a high-quality boiler like this HB Smith unit inspected by the author can suffer mishap.
Below we provide HVAC manufacturer contact information and direct links to free downloadable installation, service, and users manuals, focusing on hard-to-find manuals for older models or discontinued equipment. We also provide links to the manufacturer's current model lists and literature.
HB Smith, (Lowell Mass) beginning as a foundry in the 1800's, incorporated in 1878, made a cast iron boilers beginning before 1870 and continuing over many years. Boilers of the same size and type and even model were made over long periods and may look very much alike.
In the U.S., you can locate the H. B. Smith Company, Inc.., 47 Westfield Industrial Park Road, Westfield, MA 01085, Tel: (413) 568-3148 offers this company history at their website http://www.hbsmith.com/
The H. B. Smith Company, a true pioneer in the heating industry as we know it today, was founded in the mid-1850's by two brothers, Henry B. and Edwin Smith. Originally manufacturing fences and other ornate iron work, the Smith brothers' manufacturing expertise turned to cast-iron heating products in 1859 when they formed an association with inventor, Samuel Gold and commenced manufacturing his patented "Gold" boiler/radiator products.
As the central heating industry grew, so did The H. B. Smith Company; and by 1879 the company was also manufacturing the "Mills" boiler patented by inventor John Mills. A century and a half later, The H. B. Smith Company continues to manufacture a broad line of quality cast-iron boilers for both residential and commercial, industrial applications, including several models of "Mills" design.
From its humble beginning, our Company has weathered many economic highs and lows. Down from the high of 450 employees in 1988, we currently have a workforce numbering 50+. Our plant workers have been represented by Local 95 of the Glass, Molders, Pottery, Plastics & Allied Workers International Union for over 100 years. Management and Union employees work amicably together to ensure that high standards are always maintained.
...
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
Regina,
That's a great but difficult question. HB Smith, (Lowell Mass) beginning as a foundry in the 1800's, incorporated in 1878, made a superb line of cast iron boilers beginning before 1870 and continuing over many years. Boilers of the same size and type and even model were made over long periods and may look very much alike.
If we (or you) contacted HB Smith for help they's probably say that without a data tag that gives the boiler serial number setting an accurate age will not be possible.
You could try a more subtle approach that might earn your $1900:
Contact the company
Phone: (413) 568-3148
Fax: (413) 568-0525
Website http://www.hbsmith.com/
Letter: The H. B. Smith Company, Inc.
47 Westfield Industrial Park Road
Westfield, MA 01085
and ask if there were specific residential steam boiler features that are visually detectable and that first appeared in their boilers) in particular years beginning 30 or more years ago. For example a particular casting shape or mark or boiler feature.
Armed with that information, and even without a data tag you could at the very least assert that the boiler was made after that feature first appeared
or conversely
Ask what features disappeared so that you could also have an ending year.
see H.B. SMITH BOILERS Manuals, Contact information
Kelvin
AO Smith encodes the date in the first two digits in the second-to-last group when you see this format
K81-710-806-F0017 - that 806 = 1980
Smith Boilers (Mestek subsidiary) encode the year with aletter followed by two digits of the year
Your "Smith" boilers don't exactly match these formats,
I'm not sure which "Smith" boiler (Westcast) you've got. But from the GB I'm guessing this is a Smith Boiler. Gas-Fired hydronic or steam boiler.
You can contact Smith Boilers directly at
Westcast, Inc., 260 North Elm Street, Westfield, MA 01085 (413) 562-9631 FAX: (413) 562-3799 Website: www.smithboiler.com
I'd guess (without really knowing) you've got a 1975 and a 1985 boiler each.
(thanks to Carson Dunlop Associates Technical Reference Guide cited in and available from links in this article)
On 2017-03-29 by Regina P
I've been told my steam boiler was made by HB Smith, but the tag/sticker is nowhere on the boiler. We've owned the home since 1999, and the owners before us were here for five years before that and did not replace it.
We are planning to replace it this spring as it is rusting on the sides, and there have been some intermittent water leaks. However, none of the heating contractors we've had estimates from will certify that it is over 30 years old, which would allow us to get a $1900 tax credit/rebate. Is there a way to determine the age without that tag? The burner attached is dated from the 1986.
On 2016-10-24 by Dave re: age of old HB Smith Boilers
I have several very old H.B.Smith boilers that I need to know what the age is. They are 28A Series Serial # 28A-12-050446; H.B.Smith Model 450 Mills; Smith 28 high efficiency 8A Series, Serial #28A-11-060623
how can I tell the age of my gas boiler?
It is a HB Smith Series PV150 model @200W5 - Joe 11/1/11
Joe you gave us a model number but no serial number. Because models are manufactured over a number of years the equipment age is encoded in its serial number not its model number. Take a look on your data tag:
In the serial number the second and third digit from the left are usually the year. E.g. from Carson Dunlop's Technical Reference,
A82-2248 would translate to year of manufacture 1982
In the serial number, begining with a letter (indicating the wate heater model), the next two digits from the left indicate the year of manufacture just as the boiler serial number above.
Carson Dunlop, Associates, Toronto, have provided us with (and we recommend) Carson Dunlop Weldon & Associates'Technical Reference Guide to manufacturer's model and serial number information for heating and cooling equipment
Special Offer: Carson Dunlop Associates offers InspectAPedia readers in the U.S.A. a 5% discount on any number of copies of the Technical Reference Guide purchased as a single order.
Just enter INSPECTATRG in the order payment page "Promo/Redemption" space.
See H.B. SMITH BOILERS Manuals, Contact for more information.
(May 26, 2017) kelvin said:
Trying to find the age of two Smith cast iron boilers. S/N GB300-2002-75 & GB300-2002-85
Kelvin please see SMITH BOILER MANUALS
...
Continue reading at MANUALS for HEATING & A/C SYSTEM CONTROLS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
H.B. SMITH BOILER MANUALS also A.O. Smith & Smith Boilers & Heaters at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Or see
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
In addition to any citations in the article above, a full list is available on request.