Basement Water Entry - Stopping Leaks at Windows
Windows that leak into basements:
This article explains the causes of water entry, leak, or actual flooding of buildings when water is entering at or near basement or crawl space windows.
In the page top photo shows water leak stains below a basement window. Inspecting outdoors it is often easy to recognize where this water is coming from and thus how to stop it from entering the building.. Observing evidence of the frequency, extent, source, and causes of leaks, water entry, and actual building flooding is a critical step in evaluating a building as well as in planning the cure for building leaks, water entry, and mold.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
Visual inspection of a the exterior and interior of a building can provide ample evidence of the history of leaks and water entry at a property.
Even when a building is brand new, an experienced home inspector or waterproofing or de-watering contractor can spot conditions that are likely to lead to future leaks, water entry, flooding, and moisture or even mold problems at a structure.
If you see a downspout spilling right by the building foundation, certainly you'll want to correct this condition before calling an expert to diagnose "basement leaks".
But some very common sources of basement water entry are a bit more difficult to recognize unless you are familiar with common causes of leaks into buildings.
A client troubled by basement water leaks that were developing on her home sent the outdoor and basement interior photos we show here and at page top and asked for advice.
The outdoor photograph (left) show quite a few possible sources of leaks at or near the building corner in the center of this picture:
Inside the homeowner noticed leaks beginning to enter the basement at or near the top of the foundation wall, confirming that water was most likely coming from the ground surface. Therefore we advised the following steps:
The two half-round corrugated steel window wells shown in our photo (left) look like a proper step in reducing surface water runoff into this basement at the windows themselves.
But notice that the ground appears to slope back towards the building to the right of those stairs? An inside foundation corner tends to trap surface runoff against the building.
This detail may not be a problem in this home provided that roof drainage is not spilling at the foundation, and provided that there is no hillside sloping to drain into this area.
At WET BASEMENT PREVENTION we describe more aggressive (and costly) steps to stop basement water entry and foundation leaks using exterior drainage systems and foundation waterproofing systems such as plastic coverings and drain systems.
Here we show two more problem windows at building basements.
Above is a wood framed basement window buried in backfill. This construction detail invites both basement water entry from surface water outside, and also termite or carpenter ant damage to the structure. A window well is badly needed here.
And above this sentence we show a wood frame basement window below ground level, with its sill in dirt, and although the owners installed a window well, the well has become overgrown. Soil level in a window well needs to be about 4" below the top of the soil.
The window well above left looks nice and neat; if the steel surround is not at least 2" above soil level, ground water may run into the window well. The owners installed a plastic cover over the window well to prevent spillage from the roof eaves falling into the well.
The window well at above right is almost a great job. A concrete window well floor was installed along with a drain (hopefully conducting water to daylight away from the building). When we see details like this we guess that a previous owner or contractor was sure that water was entering the building at this spot.
Unfortunately, burying the window sill in concrete creates a risk point for rot or insect attack on the building.
Readers having problems with basement moisture should also . If your building suffers from a wet or damp crawl space or crawl space mold, see CRAWL SPACE DRYOUT PROCEDURES
...
Continue reading at WALL / WINDOW LEAK DIAGNOSIS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
WINDOW LEAKS INTO BASEMENT at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
IF above you see "Comment Form is loading comments..." then COMMENT BOX - countable.ca / bawkbox.com IS NOT WORKING.
In any case you are welcome to send an email directly to us at InspectApedia.com at editor@inspectApedia.com
We'll reply to you directly. Please help us help you by noting, in your email, the URL of the InspectApedia page where you wanted to comment.
In addition to any citations in the article above, a full list is available on request.