Q&A about asbestos cement corrugated roofing.
This article series provides a photo guide and text that can identify the condition of cement asbestos roofing products like asbestos-cement roof shingles.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
These FAQs about asbestos cement roof shingles were posted originally at CORRUGATED CEMENT ASBESTOS ROOFING - so you will want to also review the photos and information detailed there.
On 2018-11-25 by (mod) - identifying CCMTA Fiber Cement or Asbestos Cement corrugated products
Andy I see why you ask.
Searching for CCMNTA leaves us drowned in information about the Canadian Council of Motor Transport Administrators (CCMTA) .
I don't know the product in your photo and am doing some more research.
It would help to know what we're looking at.
Is this fiber cement corrugated roofing?
In what country and city?
What is the building age?
Do we know the roof age?
Meanwhile, knowing nothing else about your material I would err on the side of caution and treat it as PACM - presumed asbestos containing material (or have a sample tested).
The CMNT "A" could suggest that it's a cementious product with "A" - asbestos. BUt in truth we don't know.
On 2018-11-25 by Andy
Do you have any idea if this is asbestos or cement many thanks, as far as I can tell it says
CCMNTA X 160306I or F
On 2017-10-15 by Brendan
My neighbor is having his asbestos roof demolished. The contractors are wearing appropriate PPE but the house is not wrapped. Are my children ok t be outside duirng the removal of this roof. from a guess it looks like the cement / asbestos corrugated roofing
On 2016-10-09 by (mod) -
Quite possibly, yes, Jamie as you'll read in this article series.
On 2016-10-07 by Jamie
Can you tell me if the roof sheets were fibre cement BS 690:pt3:1981 had asbestos in them please. My email is seroofing@hotmail.com thanks
On 2015-11-04 by (mod) -
Yes if someone added it.
On 2015-11-03 by Nancy Campbell
Could a mobile home manufactured in 1978 have a corrugated asbestos cement roof?
On 2014-11-28 by (mod) -
Robert
Your options are increased air circulation and ventilation, adding heat to the area, and looking for moisture sources that can be fixed such as leaks, puddles, a poor-draining garage floor.
I would not add insulation unless you use closed-cell foam that won't pick up water.
On 2014-11-26 by robert deeks
Due to the very wet weather I am getting lots of condensation on the underside of my asbestos/concrete Marley concrete garage roof What can I do ?
On 2014-11-18 by (mod) -
Gerrett S. please see the updates in the article above where we discuss sources for the engineering properties of fiber cement and asbestos cement roofing.
On 2014-05-07 by (mod) -
Douglas, at
https://inspectapedia.com/Environment/Environment_Building.php
on the upper left of the page you'll see these articles you'll want to review:
ASBESTOS REMOVAL CERTIFICATIONS
ASBESTOS REMOVAL, Wetting Guidelines
ASBESTOS RISK ASSESSMENT
ASBESTOS ROOFING / SIDING POWER WASHING
ASBESTOS ROOFING / SIDING DUST
Principally, minimizing dust creation by how the material is handled is key. Variables include local regulations that apply in demolishing asbestos-containing materials outoors, debris disposal, etc.
Daniel
On 2014-05-07 by Douglas Bell
I have a corrugated asbestos garage roof erected in 1960's which is now deteriorating ,what precaution are required in replacing the roof?
On 2014-04-04 by (mod) -
I doubt it Michael. A roof ought not to be leaking water into the interior at all; first be sure that it's not an indoor condensation issue (which seems unlikely for a garage).
On 2014-04-04 by Michael
We have installed a fibrous cement roof but it looks like it is absorbing water & looks as if damp is ingressing the garage. Is this normal?
On 2014-03-12 by Anonymous
Depends on nature and extent of damage. On a clean, dry crack I'd try geocel or similar sealant. Or cut and patch as in slate roofing.
On 2014-03-12 by shabbir civil eng.
which material can be used for leakage asbestos sheet?
On 2014-03-12 by Anonymous
how to repair asbestos roof sheet leakage/sepage
On 2014-02-08 by (mod) -
Re-posting a reader comment
2/8/14 David Carter Said:
Re-Posting a comment from U.K. reader:
2/8/14 Some good points in this article. As a UK based asbestos roofing specialist surveyor, it's important to know that most injuries and deaths associated with asbestos cement roofs are related to falls through the roof panels.
Fiber release from asbestos roofs is minimal unless it's disturbed by drilling or scraping.
My dedicated asbestos roofing site contains more information about the repair and refurbishment of corrugated asbestos roof panels at asbestosroofig co uk
-
Thanks for the comments, David, we welcome hearing from our U.K. readers. I'll review your website and find a location to include the link. Our security software does not permit links posted in comments. Your link refers to a company selling asbestos roofing services.
WATCH OUT: I think we need to know more about your company's asbestos roof cleaning proposal as a treatment option.
As we report in these pages, there have been serious asbestos fiber release and contamination issues arising from cleaning operations (like power washing) a fiber cement or asbestos-cement roof.
The washwater itself is asbestos-contaminated and as that water dries asbestos particles are easily airborne.
Keep in mind that in addition to asbestos fibers, ultra-fine asbestos particles were used as fillers in many asbestos cement products, increasing the particle hazard.
Coating or roofing over an asbestos based roof most likely minimizes the disturbance hazard.
...
Continue reading at ASBESTOS ROOFING / SIDING DUST or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
CORRUGATED CEMENT ASBESTOS ROOFING FAQs at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Or See
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.