Complete Aluminum Wiring Bibliography
|
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
Aluminum electrical wiring hazards research bibliography & references: bibliography of publicly available articles, pamphlets, resources providing information about
aluminum electrical wiring.
Green links show where you are. © Copyright 2013 InspectAPedia.com, All Rights Reserved. Author Daniel Friedman.
Aluminum Wiring Bibliography
ALUMINUM WIRING HAZARDS & REPAIRS - see detailed links at page top & left
Recommendations for the Homeowner/Occupant
- "The Trouble With Aluminum Wiring," Consumer Reports, January, 1981, p. 42
-
"The Use of Aluminum Conductors with Electrical Wiring Devices in Electrical
Wiring Systems," Underwriters Laboratories, Inc., 333 Pfingsten Road,
Northbrook, IL 60062, Issued March 1973, reissued July 1980
- J. Aronstein, "Reducing the Fire Hazard in Aluminum-Wired Homes,"
Wright-Malta Corporation, Ballston Spa, NY, Jan. 25, 1982
- Reducing the Fire Hazards in Aluminum-Wired Homes
- "Is YOUR Aluminum Wiring Safe?" article discussing safety claims made without looking at the wiring, J. Aronstein, 11/21/95
- CPSC Publication 516 on Aluminum Wiring
Information on Aluminum Wiring for Home Inspectors
- D.J. Friedman, "Safety Considerations for the Electrical Inspector," The ASHI
Technical Journal of home inspection and in-service building component
failures, Vol. 2 No. 1, Winter, 1992
- D.J. Friedman, "Aluminum Wiring Poses Potential Fire Hazard," The Journal of
Light Construction, June 1996 [Reprinted in the ASHI Reporter, January 1997,
p.10-11]
Field Surveys of Aluminum Wiring Hazards & Failures
-
"National Controlled Study of Relative Risk of Overheating of Aluminum
Compared with Copper Wired Electrical Receptacles in Homes and Laboratory,"
Executive Summary. Prepared for U.S. Consumer Product Safety Commission.
Report #F-C4812-01, Franklin Research Center, Philadelphia, PA, April 20,
1979
- R. Newman and W.H. King, Jr., "Pilot Survey of Branch Wiring Systems in
Montgomery County, Maryland," U.S. Consumer Product Safety Commission, Sept.,
1977
- J. Aronstein, "Summary Report, Study of Overheating of Aluminum-Wired
Electrical receptacles in Scarborough, Toronto, Homes," Wright-Malta
Corporation, Ballston Spa, NY, Jan. 11, 1982
Aluminum Wiring Connectors/Connections
- H. Dupre, "The Problems Involved in Designing Connectors for Aluminum Cable,"
Misc. Paper no. 51-325, AIEE Fall General Meeting, October, 1951.
- J. Aronstein and W.E. Campbell, "Overheating Failures of Aluminum-Wired
Special Service Connectors," IEEE Trans. Components, Hybrids, and Mfg. Tech.,
V. CHMT-6 No. 1, Mar. 1983
- N.T. Bond, "Reliability in Electrical Terminations on Aluminum Conductors,"
Electrical Products Div., Alcoa Conductor Products Co., Alcoa Laboratories,
Massena, NY.
- C.W. Zimmerer and F.Neumer, "Aluminum Building Wires and Connectors,"
Bulletin of Research, No. 48, Underwriters Laboratories Inc., Sept. 1954
- J. Aronstein and W.E. Campbell, "The influence of Corrosion Inhibitor and
Surface Abrasion on the Failure of Aluminum-Wired Twist-on Connections," IEEE
Trans. Components, Hybrids, and Mfg. Tech., V. CHMT-7 No. 1, March, 1984.
- R. Schubert, "Erratic Behavior of Al/Al Wire Junctions," Elecrical Contacts -
1986, Proceedings of the 32nd IEEE Holm Conference on Electrical Contacts,
Boston, 1986.
-
"Test of 'Old Technology' Aluminum Wire With Twist-On Connectors," Project
Report CPSC-C-79-0079, Task II, for U.S. Consumer Product Safety Commission.
Wright-Malta Corp., Ballston Spa, NY, November 23, 1981
- J. Aronstein, "Overheating Failures of Presently-Listed Aluminum Wiring
Connection Combinations Within Rated Service Conditions". Wright-Malta
Corp., Ballston Spa, NY, November 23, 1981
- R.L. Hicks, "Pigtail Splicing Connections for Baseboard Heaters and Similar
Cyclic Loads," Ontario Hydro, Research Division
Failure Mechanisms of Aluminum Wiring
- M. Braunovic, "Fretting Corrosion Between Aluminum and Different Contact
Materials," Electrical Contacts - 1977, Proceedings of the 23rd Annual
Meeting of the Holm Conference on Electrical Contacts, Chicago, 1977.
- M. Braunovic, "Effect of Fretting on the Contact Resistance of Copper,
Aluminum, and Nickel-Coated Aluminum Wire Connections," Wear, V. 112, 1986.
- N.T. Bond, D.L. Robinson, and M. Mohajery, "Fundamental Considerations of
Aluminum Electrical Contact Interfaces," Elecrical Contacts - 1977,
Proceedings of the 23rd Annual Meeting of the Holm Conference on Electrical
Contacts, Chicago, 1977.
- J. Aronstein, "Electromigration Failure of Aluminum Contact Junctions,"
Elecrical Contacts - 1995, Proceedings of the 41st Annual Meeting of the
Holm Conference on Electrical Contacts, Montreal, 1995.
- J. Aronstein, "Conduction in Failing Aluminum Connections," Electrical
Contacts - 1990, Proceedings of the 36th IEEE Holm Conference on Electrical
- Contacts meeting jointly with the 15th International Conference on Electrical
Contacts," Montreal, 1990.
- M. Leger, "Metallurgical Analysis of Failed CO/ALR Devices," Ontario Hydro,
#78-54-K, Ontario, Canada, February, 1978.
- J. Aronstein, "Failure of Aluminum Connections in Residential Applications,"
Elecrical Contacts - 1991, Proceedings of the 37th Annual Meeting of the Holm
Conference on Electrical Contacts, Chicago, 1991.
- J. Aronstein, "AC and DC Electromigration in Aluminum Contact Junctions,"
Electrical Contacts - 1996, Proceedings of the 42nd IEEE Holm Conference on
- Electrical Contacts meeting jointly with the 18th International Conference on
Electrical Contacts," Chicago, September 1996
Nickel Plated Aluminum Wire
- H.O. Hansson, "Sinipal: Swedish-bred Aluminum Substitute for Copper Wire,"
Wire and Wire Products, September, 1970.
- J. Aronstein and T.K. Hare, "Evaluation and Analytical Electron Microscopy
Investigation of a Plated Aluminum Wire for Branch Circuit Applications,"
IEEE Transactions on Components, Hybrids, and Manufacturing Technology, V.
11, No.2, June 1988, p. 218-226
Copper-Clad Aluminum Wire
- J.C. Fan, "An Examination of Copper Clad Aluminum Conductor for Circuit Size
Wiring," Texas Instruments Inc., Metallurgical Materials Div., Wire Products
Dept., Attleboro, MA.
Alloy Aluminum Wire
- J. Aronstein and W.E. Campbell, "Evaluation of an Aluminum Conductor Material
for Branch Circuit Applications," IEEE Trans. Components, Hybrids, and Mfg.
Tech., V. CHMT-8 No. 1, Mar. 1985
Connector/connection standards and test methods
- UL Standard 1567, Underwriters Laboratories, Inc., Northbrook IL
(CO/ALR Wiring Device Terminals for Aluminum Wire)
-
UL Standard 486C, Underwriters Laboratories, Inc., Northbrook IL
(Splicing Connectors for Aluminum Wire)
- ASTM B812-90, "Standard Test Method for Resistance to Environmental
Degradation of Electrical Pressure Connections Involving Aluminum and
Intended for Residential Applications," ASTM, 1916 Race Street, Philadelphia,
PA
Industry Handbooks
"Aluminum Building Wire Installation Manual and Design Guide," The Aluminum
Association, Inc.
Government Agency Documents
- R. Newman, "Hazard Analysis of Aluminum Wiring," April, 1975, U.S. CPSC,
NIIC-0600-75-H006
- J.T. Wilson, "Report of the Commission of Inquiry
on Aluminum Wiring," Ontario, Canada,
March, 1979
- J. Aronstein, "Tests of 'Old Technology' Aluminum Wire," Wright-Malta Corp.
Project Report CPSC-C-81-1418, U.S. Consumer Product Safety Commission,
Washington, DC, Feb. 10, 1983
Aluminum Electrical Wiring Hazards, Inspection, Repair Procedure documents available on Internet:
ALUMINUM WIRING HAZARDS & REPAIRS
ALUMINUM WIRE FAILURE REPORTS
ALUMINUM WIRING IDENTIFICATION
ALUMINUM WIRING RENTAL HOME ADVICE
ALUMINUM WIRING REPAIR METHODS
ALUMINUM WIRE CHANGEOUT
ALUMINUM WIRE AlumiConn
ALUMINUM WIRE COPALUM
ALUMINUM WIRE SPLICES
ALUMINUM WIRE GROUNDS
MAKE SPACE FOR ALUMINUM CONNECTORS
REDUCE THE AL WIRE RISK: DETAILS
ALUMINUM WIRING REPAIR ELECTRICIANS
ALUMINUM WIRING REPAIR, Other Products
ALUMINUM WIRING REPAIR COALR & CU-AL DEVICES
ALUMINUM WIRING REPAIR NOT-Recommended
COALR or / CU/AL Devices
HARBOR FREIGHT CRIMPER
IDEAL-65 Purple Twister
MARRETTE B-Cap Connector
SCOTCHLOK 3-M Connector
Wiring Repair Methods CPSC Meeting
ALUMINUM WIRING SAFETY RISKS
Aluminum Wiring - CPSC Publication #516-PDF
Aluminum Wiring - CPSC Publication #516-HTML
ALUMINUM-WIRED HOMES, REDUCE THE HAZARD
ALUMINUM WIRING REPAIR METHODS
ALUMINUM WIRE CHANGEOUT
ALUMINUM WIRE AlumiConn
ALUMINUM WIRE COPALUM
ALUMINUM WIRE SPLICES
ALUMINUM WIRE GROUNDS
MAKE SPACE FOR ALUMINUM CONNECTORS
REDUCE THE AL WIRE RISK: DETAILS
ALUMINUM WIRING REPAIR ELECTRICIANS
ALUMINUM WIRING REPAIR, Other Products
ALUMINUM WIRING REPAIR COALR & CU-AL DEVICES
ALUMINUM WIRING REPAIR NOT-Recommended
COALR or / CU/AL Devices
HARBOR FREIGHT CRIMPER
IDEAL-65 Purple Twister
MARRETTE B-Cap Connector
SCOTCHLOK 3-M Connector
Wiring Repair Methods CPSC Meeting
BOOKSTORE - ELECTRICAL
DIRECTORY OF ELECTRICIANS - Aluminum Wiring
DIRECTORY OF ELECTRICIANS - FPE Zinsco
Aluminum Wiring Bibliography
Fire Ignition/Fire investigation
- J. Aronstein, "Fire Due to Overheating Aluminum Wired Branch Circuit
Connections," Electrical Safety Conference, Univ. of Wisconsin-Extension,
Madison, WI, April 7, 1981
Contact Addresses for Requesting Information
- The American Society of Home Inspectors, ASHI 847-290-1919
85 West Algonquin Road 847-290-1920 FAX
Arlington IL 60005-4423
http://inspectapedia.com/home_inspection/ashihome.htm
-
The Aluminum Association,
900 19th St.
NW, Washington DC 20006
-
NFPA - (National Fire Protection Association)
1 Batterymarch Park
P.O. Box 9101
Quincy, MA 02269-9101
-
UL - Underwriters Laboratories Inc.
333 Pfingsten Road
Northbrook, IL 60062
-
NEMA -National Electrical Manufacturers Association
2101 L Street, N.W.
Washington, DC 20037 202-457-8400 FAX 202-457-8411
-
Internat. Assoc. of Elect. Insp. 214-235-1455
901 Waterfall Way, Suite 602 214-235-3855
Richardson, TX 75080 6226,563 CIS
-
The Journal of Light Construction 802-434-4747
RR2 Box 146 jlc@bginet.com
Richmond VT 05477
-
Also AIEE - tbd.
Frequently Asked Questions (FAQs)
...
Ask a Question or Search InspectApedia
Questions & answers or comments about where to find the most authoritative information about aluminum electrical wiring in homes: hazards, history, inspection, troubleshooting & repair procedures. .
Ask a Question or Enter Search Terms in the InspectApedia search box just below.
Technical Reviewers & References
Related Topics, found near the top of this page suggest articles closely related to this one.
The Aluminum Wiring Information Website Aluminum Wiring Hazards and Repairs: in-depth info, photos, documents. Main Page.
- The Aluminum Electrical Wiring Hazard Explained (in the document you are presently viewing)
- ALUMINUM WIRE REPAIR METHODS to reduce risk in buildings with Aluminum Electrical Wiring - Overview of Acceptable Repair Practices (in the document you are presently viewing)
- Aluminum Wire Repair Method Details - "How to" details, how to identify, COPALUM repair, alternative repairs, history, products, research, source of special AMP TYCO COPALUM connectors & COPALUM Electricians (in the document you are presently viewing)
- COPALUM Electricians: Sources of TYCO COPALUM -Certified/Trained Aluminum Wire Repair Services (in the document you are presently viewing)
- Other Products, Ideal 65 Purple Twister (not recommended), & other Aluminum Wire Products/Articles (in the document you are presently viewing)
- * Safety Hazards and Safe Inspection Procedures for Electrical and Home Inspectors at Residential Electric Panels
- Electrical Panels, How to Inspect in buildings, safety for electrical inspectors, electrical panel, fusing, wiring defects, defective products. Inspection Class Presentation
- Electrical System & Wiring Hazard Inspection, Detection, Cause, Remedy, Prevention - Main Electrical Page
- ...
Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair
The Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.
Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.
|
|