Title 5 Water Test Parameters
What drinking water contamination tests should you order?
This article explains the general classes of water contaminants covered in a
Title 5 water test. Sketch of a dug well courtesy of Carson Dunlop Associates, a Toronto home inspection, education & report writing tool company [ carsondunlop.com ].
This website describes the types of water testing available, outlines common water test fees, describes the details of what parameters are included in various water test options, and gives advice to assist you in deciding what tests to order.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
ADVERTISEMENT
Title 5- water test parameters and how to check for pesticide contaminants in drinking water
This article lists a set of Title 5 Water Testing parameters for property buyers or owners who need to meet Title 5 (Title V) property and drinking water standards. Review this requirement with your lender. Be sure to review actual parameters with your home inspector or laboratory: parameters and costs vary.
Title 5 Water Test Parameter List |
|
Organics
|
Benzene |
Bromobenzene |
Bromochloromethane |
Bromodichloromethane |
Bromoform |
Bromomethane |
n-Butylbenzene |
sec-Butylbenzene |
tert-Butylbenzene |
Carbon-Tetrachloride |
Chlorodibromomethane |
Chloroethane |
Chloroform |
Chloromethane |
o-Chlorotoluene |
p-Chlorotoluene |
1,2-Dibromo-3-Chloropropane |
Dibromomethane |
1,2-Dibromoethane |
m-Dichlorobenzene |
o-Dichlorobenzene |
para-Dichlorobenzene |
Dichloromethane |
Dichlorodifluoromethane |
1,1-Dichloroethane |
1,2-Dichloroethane |
1,1-Dichloroethylene |
cis-1,2-Dichloroethylene |
trans-1,2-Dichloroethylene |
1,2-Dichloropropane |
1,3-Dichloropropane |
2,2-Dichloropropane |
1,1-Dichloropropene |
1,3-Dichloropropene |
trans-1,3-Dichloropropene |
Ethylbenzene |
Fluorotrichloromethane |
Hexachlorobutadiene |
Isopropylbenzene |
p-Isopropyltoluene |
Monochlorobenzene |
Napthalene |
n-Propylbenzene |
Styrene |
1,1,1,2-Tetrachloroethane |
1,1,2,2-Tetrachloroethane |
Tetrachloroethylene |
Toluene |
1,2,3-Trichlorobenzene |
1,2,4-Trichlorobenzene |
1,1,1-Trichloroethane |
1,1,2-Trichloroethane |
Trichloroethylene |
1,2,3-Trichloropropane |
1,2,4-Trimethylbenzene |
1,2,5-Trimethylbenzene |
Vinyl Chloride |
o-Xylene |
m-Xylene |
p-Xylene |
|
|
Total Coliform
|
Ammonia |
Nitrate |
...
Continue reading at TOTAL COLIFORM TESTING or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
Recommended Articles
Suggested citation for this web page
TITLE 5 WATER TEST PARAMETERS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Share this article:
Questions & answers or comments about title V or Title 5 Water Test Parameters.
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
Citations & References
In addition to any citations in the article above, a full list is available on request.
- 1-Bromo-3-chloro-5,5-dimethylhydantoin (C5H6BrClN2O2) is produced world-wide and is also used in cleaners and bathroom disinfectants and deodorizers. Here is an example MSDS for this product, provided by Leisure Time
- "Bacteria in Drinking Water" - "Chlorine," Karen Mancl, water quality specialist, Agricultural Engineering, Ohio State University Extension. Mancl explains factors affecting the effectiveness of chlorine in water as a means to destroy bacteria and other microorganisms. OSU reports as follows:
- Chlorine kills bacteria, including disease-causing organisms and the nuisance organism, iron bacteria. However, low levels of chlorine, normally used to disinfect water, are not an effective treatment for giardia cysts. A chlorine level of over 10 mg/1 must be maintained for at least 30 minutes to kill giardia cysts. -- http://ohioline.osu.edu/b795/index.html is the front page of this bulletin
- "Chemicals and Our Health", Nicholas D. Kristof, New York Times, 16 July 2009, p. 27. This outstanding editorial calls for improvements in public health policy to address phthalates and other environmental contaminants from common chemicals and products in everyday use. - DJ Friedman
- Crystal Clear Supply provides portable ceramic water filter purifiers and portable reverse osmosis water treatment equipment - see http://www.crystalclearsupply.com/category_s/7.htm
- CHLORINE IN DRINKING WATER - Does Chlorine in Drinking Water Harm the Septic Tank? - Septic Tank Cleaning Advice
- CHLORINE IN SEPTIC WASTEWATER - Septic Tank Maintenance: Chlorine in Septic Systems - Septic Tank Maintenance Advice
- Cheating on water tests: Testing Water for Real Estate Transactions - make sure your water test is valid
- Chlorinate or Shock a Well, When, How-to - Procedure for Shocking a Well to (temporarily or maybe longer) "Correct" Bacterial Contamination
- Choices of Water Tests & Fees: A Summary of Types of Water Tests, Degrees of Comprehensive Water Testing, Details of Water Test Parameters
- Correcting Unsatisfactory Water what to do, when to do it, treatment alternatives, equipment, filters, etc.
- Disinfectants in water: www.epa.gov/ogwdw/mdbp/pdf/alter/chapt_2.pdf provides an article on use of disinfectants for water treatment
- "Drinking Water Safety in Emergencies", University of Minnesota extension, extension.umn.edu/info-u/nutrition/BJ646.html
- Drinking Water testing, contamination, correction - all topics
- Drinking Water Testing Advice for home buyers home owners home inspectors
- Endocrine Disruptor Exchange, Dr. theo Colborn (also see Our Stolen Future). From that website: The Endocrine Disruption Exchange, Inc. is the only organization that focuses primarily on the human health and environmental problems caused by low-dose and/or ambient exposure to chemicals that interfere with development and function, called endocrine disruptors. ... TEDX's work focuses on the endocrine system, which is the exquisitely balanced system of glands and hormones that regulates such vital functions as body growth, response to stress, sexual development and behavior, production and utilization of insulin, rate of metabolism, intelligence and behavior. Hormones are chemicals such as insulin, thyroxin, estrogen, and testosterone that interact with specific target cells. The interactions occur through a number of mechanisms, the easiest of which to conceptualize is through a lock and key arrangement.
- Giardia exposure limits for drinking water: see www.mass.gov/dep/water/drinking/standards/giardia.htm is the current regulatory exposure limit (your minimum target for
sterilization)
- Health Effects of Chemical Contaminants in Drinking Water, US Environmental Protection Agency,
- Hydrogen peroxide: Wikipedia on history of use of hydrogen peroxide: Information on Hydrogen peroxide as a sterilant is in Wikipedia at en.wikipedia.org/wiki/Sterilization_(microbiology) HO2 has been
used for a long time, including by vaporization for sterilizing freeze dryers.
- Hydrogen Peroxide warning: US FDA Warning about drinking hydrogen peroxide: www.truthorfiction.com/rumors/h/hydrogen-peroxide.htm This article cites a 2003 entry in Journal
of Food and Science on using Hy.Perox to sterilize vegetables, referring to E.coli - NOT to Giardia.
- Iodine: "Do Iodine Water Purification Tablets Provide an Effective Barrier against Cryptosporidium parvum?", Starke, Jeffrey A., Bowman, Dwight D., Labare, Michael, Fogarty, Elizabeth A., and others, Military Medicine, 25 October 2001 [possibly a later version of this article appeared in 2005 -DF] http://www.amsus.org/military medicine/milmed.htm
- National Primary Drinking Water Regulations - The complete regulations regarding these contaminants available from the Code of Federal Regulations Website -(United States)
- Ohio State University article on the concentration of chlorine necessary to act as an effective disinfectant, and the effects of the water's pH and temperature: See http://ohioline.osu.edu/b795/b795_7.html for details.
- Our Stolen Future: Are We Threatening Our Fertility, Intelligence, and Survival?--A Scientific Detective Story, Theo Colborn, Dianne Dumanoski, John Peter Meyers. Plume-Penguin Publishing, 1997, ISBN 0-452-27414-1., ISBN13: 9780452274143. This book is a seminal work on endocrine disruptors (chemical contaminants having impact at extremely low levels in the environment).
Recommended by Daniel Friedman, this book is a critical update to the landmark Silent Spring by Rachel Carson and discusses the effects of minute trace amounts of chemical contaminants in the environment. The text "Identifies the various ways in which chemical pollutants in the environment are disrupting human reproductive patterns and causing such problems as birth defects, sexual abnormalities, and reproductive failure. Reprint. Tour. NYT."
Amazon.com Review: By O T (Ontario, BC) - 'Our Stolen Future' is a great introduction to one of the most important scientific discoveries in our time. Having recently completed a thesis project at university on Endocrine Disruptors, I have reviewed hundreds of papers on the subject. This book is a good clear overview of the scientific literature on EDs. The authors are experts - Theo Colborn is largely responsible for creating the field by bringing together diverse researchers so they could see the big picture of their work. Many of the principle investigators are interviewed and quoted at length on the way chemicals participate in and interfere with delicate hormonal systems in animals (including humans). The major accomplishment of the book is to make an easy-to-follow story out of complex research. Many resources are available to help you assess the reliability of this story, and the best thing to do if you have any doubts is read review articles in scientific journals (which are easier to understand than technical papers). The Physicians for Social Responsibility (PSR) have a guidebook for health-care professionals on Endocrine Disruptors, and the US EPA has many reports on the matter. Beware of people or websites who try to 'debunk' this book (or the science behind it) by simply declaring it false, flawed or disproven. There is far too much supporting research for so simple a refutation.
OPINION: Significant and discussed in this book is the observation that at certain critical points in the development of animals, presumably including humans, exposure to extremely low levels of endocrine disruptor chemicals (EDC's) (such as BPA - Bisphenol-A or BPA, Diethylstilbestrol - DES, dioxins, PCBs, and chemicals used in the production of certain cleansers, dyes, flame retardants, plastics, pesticides, white papers ) perhaps just a few molecules, or in the parts per trillion, is sufficient to cause disruption of the animal's development, including proper sex differentiation, or the lack of it that produced androgynous ducks unable to reproduce under such conditions.
A endocrine disruptor is a synthetic chemical compound that mimics natural hormones when it is taken into the body of a human or other animal. It "disrupts" the endocrine system by turning on or off normal chemical signals that in turn can affect normal hormone levels, bodily functions, and significantly, the development of embryos. Further, unlike naturally occurring hormones ingested, for example from plants (phytoestrogens), synthetically-generated hormones accumulate in the body and can have a half-life of decades or longer.
One significance of this finding includes the observation that an important medical effect that occurs with exposure to chemicals in extremely low concentrations means that experiments to test for correlations between chemical exposure and subsequent serious medical problems will be deeply flawed if, for example, the experimental design does not include testing for the presence of the chemical at extremely low levels. A related concern is that even if harmful effects from exposure to extremely low concentrations of an endocrine disruptor are occurring, teasing out and proving that relationship can be also extremely difficult.
- Silent Spring, Rachael Carson, Mariner Books; Anv edition (October 22, 2002), ISBN-13: 978-061824906.
Amazon.com Review:
Silent Spring, released in 1962, offered the first shattering look at widespread ecological degradation and touched off an environmental awareness that still exists. Rachel Carson's book focused on the poisons from insecticides, weed killers, and other common products as well as the use of sprays in agriculture, a practice that led to dangerous chemicals to the food source. Carson argued that those chemicals were more dangerous than radiation and that for the first time in history, humans were exposed to chemicals that stayed in their systems from birth to death. Presented with thorough documentation, the book opened more than a few eyes about the dangers of the modern world and stands today as a landmark work.
- Shock or Chlorinate a Well, When, How-to - Procedure for Shocking a Well to (temporarily or maybe longer) "Correct" Bacterial Contamination
- US EPA: list of drinking water contaminants: see http://www.epa.gov/safewater/contaminants/index.html
- UV light: This patent application for UV light sterilization www.patentstorm.us/patents/6565803.html Lists good references on water
purification for Giardia et als
- Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
- In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested
CONTINUE READING or RECOMMENDED ARTICLES.
ADVERTISEMENT