Gas furnace inspection curriculum& defects list.
This article lists significant gas fired heating furnace defects, definitions, and home inspection education topics.
The building defects and inspection points listed in these articles also guide homeowners and home buyers to building areas that merit careful attention and often point areas of safety concern or important maintenance and repair tasks. Page top illustration of a gas fired furnace courtesy of Carson Dunlop Associates, a Toronto home inspection, education & report writing tool company [ carsondunlop.com ].
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Editor/Publisher - See WHO ARE WE?
1. Describe the function of residential heating systems.
2. Describe the common heating fuels (gas, oil, propane, electricity, wood).States GAS above ??
3. Describe the combustion process with reference to the fire triangle, combustion air, ignition, and venting.
4. Describe three methods of heat transfer(radiation, convection, conduction) and how each apply to residential heating systems.
5. Describe the common visually detectable defects in gas fired heating systems and identify safety hazards
6. Describe the common types of heating equipment (furnaces, hot water boilers, steam boilers, space heating, radiant heating).
7. List the materials, function and location for the components of a gas fired forced air furnace including
8. Differentiate between conventional, mid efficiency and high efficiency gas furnaces. Include a description of the normal operating cycle for each.
9. Describe the features of adequate installation and repair technique for gas fired forced air furnaces.
10. Define the following terms with respect to gas fired heating systems: gas pressure regulator, gas meter, drip leg(dirt pocket), flex connectors, combustion air, draft air, dilution air, circulating air, spillage(back drafting, down drafting), natural gas, BTU content of natural gas, monoport burner, multi port burner, cross over igniter refractory (firepot), ,(Norrmally only in oil fired systems) JDG gas valve, pilot light, thermocouple, fan/limit switch, heat shield(flame roll out shield), heat exchanger, indirect fired system, direct fired system, draft hood, blower(house fan, furnace fan, air handler, furnace blower),
Fan door safety relay..JDG, up flow furnace, down flow furnace, horizontal furnace, summer switch, fan compartment interlock switch, thermostat, heat anticipator, vent connector, supply plenum, return plenum, filter, supply duct system, return duct system, supply registers, return grills, electronic air cleaner, humidifier, input capacity, output capacity, bonnet capacity, steady state efficiency, seasonal efficiency, steady state losses, off cycle losses, stack effect, AFUE, separation of circulating and combustion air.
11.Define the following terms with respect to mid and high efficiency gas furnaces: vent damper, intermittent pilot, direct spark ignition, hot surface ignition, flame rectification, natural draft burners, induced draft burners, forced draft burners, pre-purge, side wall venting, sealed combustion, direct vent, mid efficiency, high efficiency, condensing furnaces, latent heat of vaporization, neutralizer, differential pressure switch, heat switch(spillage switch), blower cover interlock, pulse combustion, combination furnaces(water heater and furnace), tempering valve (mixing valve).
12. Outline the life expectancies for gas fired forced air furnaces.
13. Identify the codes and standards which apply to gas fired appliances and warm air heating systems in your area.
1. Describe the inspection procedure for conventional, mid efficiency and high efficiency, forced air gas furnaces.
2. Identify the following common defects listed on the next page.
3. Describe the implication of each defect.
4. Identify safety issues for the inspector and occupant of the house (gas explosion, carbon monoxide poisoning, injury due to moving parts).
5. Communicate findings to client verbally and in writing, recommending corrective action where needed.
Gas meters - general gas supply piping, regulators, controls
Gas regulators & control valves at the heating equipment
• Gas shut off and locked
• Loose
• Ice
• Missing
• Leaks
• Rust
• Mechanical damag
• Scorched
• Poor access
• Poor location
Heat shield defects at the gas burner - burns, rust, missing, damaged, leaks
Soot - Carbon Monoxoide fatality risk warnings
flame leakage
rust or water or mechanical damage
• Rust
• Undersized
• Connector extends too far in chimney
• Draft hood spillage or backdrafting
• Improper material
• Inadequate combustible clearance
• Copper tubing not properly labeled • Poor manifolding
• Improper connections
• Poor slope
• Inadequate support
• Poor support
• Inappropriate materials
• Poor connections
• Leak
• Rust, dirty, obstructed
• Missing shut off valves
• Vent connector too long
• No drip leg
• Vent connector too big or too small
• Piping in chimney or duct systems
• Plastic pipe exposed above grade
• Rust Corrosion. JDG
• Airflow proving switch problems
• Condensate problems
• Electronic ignition problems
• Inadequate combustion air
• Excess temperature rise
• Heat exchanger problems
Gas Burner Defects at Gas Furnaces
• Induced draft fan problems
• Poor vent location, arrangement
• Delayed ignition
• Poor combustion air intake location
• Dirt or soot
• Spillage switch problems
• Flame wavers when fan comes on
• Vent damper stuck
• Gas odor or leak
• Inoperative
• Poor flame color or pattern
• Rust Corrosion..JDG
• Scorching
• Short cycling
• Cracks, holes or rust
• Excess temperature rise
• Soot or deposits
• Dirty
• Installed backwards
• Loose or collapsed
• Missing
• Wrong size
• Damaged cells
• Dirty
• Improper orientation
• Inoperative
• Mis-wired
• Missing components
• Combustible clearances
• Mechanical damage
• Missing components
• Obstructed air intake
• Rust
• Scorching
• Anticipator problems
• Damaged
• Dirty
• Loose
• Not level
• Poor adjustment or calibration
• Poor location
• Clogged pad, mesh or nozzle
• Dirty
• Inoperative motor or solenoid valve
• Leaks
• No duct damper
• Poor location
• Dirty
• Fan belt loose, worn, damaged
• Inoperative
• Noisy
• Overheating
• Poorly secured
• Running continuously
• Rust
• Too small
• Unbalanced or vibration
• Balancing damper adjustment
• Dirty, obstructed collapsed
• Disconnected or breached JDG or damaged ducts
• Excessively long runs, excessive elbows
• Wire or pipes in ducts
• Registers or grilles (for return air) in garage
• Rusting or dirty
• In-slab ducts
• Mechanical damage
• Leaky joints
• Insulation missing, damaged
• Filter problems
• Undersized
• Weak airflow
• Improperly wired
• Missing cover
• Scorching
• Set wrong or defective
• Fan problems
• Cabinet problems
• Control problems
• Domestic water too hot
• Inadequate heat for house
• Inoperative, inefficient pumps
• Inoperative water heater
• Leaking, clogged coils
• Water control problems
Readers should see FURNACES, HEATING
and HEATING SYSTEMS for our complete list of articles on this topic.
Also see HOME & BUILDING INSPECTORS & INSPECTION METHODS.
See HEATING SYSTEM INSPECT DIAGNOSE REPAIR.
Also see HEAT EXCHANGER LEAK TEST, s
and see GAS PIPING, VALVES, CONTROLS,
FLAME COLOR, BLUE vs YELLOW COMBUSTION, FIREPLACES & HEARTHS
Watch out: these inspection lists do not list all possible defects for the systems discussed, and not all home or building inspectors will examine all of the items listed here. CONTACT us to suggest corrections or additions to articles at this website.
These curriculae and building defect lists are based on smilar curriculum documents first prepared by Joe Scaduto, an ASHI member who prepared course material for Northeastern University's Building Inspection Certificate program in 1988, subsequently by DF, InspectApedia's editor, for New York University ca 1988 and later, with others, recommended to ASHI, the American Society of Home Inspectors. ASHI did not adopt this material though currently that association as well as others offer extensive HOME INSPECTOR EDUCATION material.
The curriculum and lists of defects are informed by additional analysis of the process of home inspection that was developed beginning Calgary, AB for Canadian and U.S. home inspector education and certification examinations in 1997. Other early contributors to home inspection education in the U.S. and Canada include Dr. Jess Aronstein, Alan Carson, Mike Casey, Mark Cramer, John Cox, Dwight Barnett, Douglas Hansen, Rick Heyl, Larry Hoytt, Bill Merrill, Kevin O'Malley, Dennis Robitalille, Keith Peddie, Pat Porzio, Roger Robinson.
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
On 2019-10-16 - by (mod) -
What happens if you disconnect the thermostat wires at the heater and jump the two TT terminals?On 2019-10-16 by Mike
Working on a 90,000 but googman gas heater. Thermastate is on heat, but furnace will not come on. Board has steady light, all limits are closed, even changed board out just in case, nothing. Have not checked the thermstate yet! Any thoughts?
On 2018-09-30 - by (mod) -
AnonOn 2018-09-30 by Anonymous
I have a janitors forced air furnace model # 37065-4 and want to get manual for it
On 2018-02-01 by Nichole Alexander
Will a gas powered wall-mount furnace pass inspection without identification plates? Blower fan? Externally located thermostat?
On 2017-10-12 - by (mod) -
Tricia,On 2017-10-11 by tricia f
Hello, I bought an holder home (1945) last year. There was at one point an oil furnace, however now it is gas-fired furnace. I suspect that the original ductwork is hooked up to the currentl furnace. We had the ducts cleaned out when we moved in (via a truck mounted system, and nothing was sprayed into the ducts). They had never been cleaned (in over 60 years).
There is still a small amount of building material, debris and dirt in the ductwork where the men simply could't get deep enough into the vents, but they are MUCH cleaner. The company said it was the 2nd worst home they'd ever seen.
We noticed an oil smell coming from the supply vents when we tuned the furnace on last winter. We run air purifiers in the home. I also keep filters in every vent, and have to change the main furnace filter once a month.
Over the summer, when the windows were open, I would occasionally notice a petroleum/oil like smell draft through part of the main floor, but could not pinpoint it. Last night, as I was preparing to turn on the furnace for the winter, I discovered that the smell was actually coming from the return air duct (as well as the supply ducts), too.
This is surprising because I did not notice it from this duct last winter. So either I am becoming more sensitive, or the "smells" of the previous owner are going away and we are noticing other smells now. Is it possible that oil contamination can be in the ducts – I am surprised that the return would also smell so bad? Other than replacing the duct work, is there anything else that we can do? Thank you so much for your assistance. I appreciate the information on this site so much.
Kind regards,
Tricia
...
Continue reading at BLUE vs YELLOW COMBUSTION FLAMES or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
HEAT FURNACE GAS DEFECTS LIST at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Or see
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.