Sooty gas burner (C) Daniel FriedmanHeating Boiler, Gas: Defects List

Gas heating boiler defets list for home inspections: This article lists significant gas fired heating boiler defects, definitions, and home inspection education topics.

This article series, beginning at BUILDING DEFECTS LISTS, provides lists of common building defects and basic defect knowledge that also outline recommended curriculum content for home inspector education. The building defects and inspection points listed in these articles also guide homeowners and home buyers to building areas that merit careful attention and often point areas of safety concern or important maintenance and repair tasks.

Watch out: these inspection lists do not list all possible defects for the systems discussed, and not all home or building inspectors will examine all of the items listed here.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?





ADVERTISEMENT





Home Inspection Education Curriculum - Heating, Gas Boilers

High efficiency heater problems (C) Daniel Friedman

4.    HEATING, Gas Fired Boilers: Inspection Recommendations & Typical Defects Lists

4.1   Gas Fired Warm Heating Boilers Inspection Recommendations & Education

4.1.1 Knowledge Base for Inspecting Gas Fired Heating Boilers - Hydronic Systems

1.    Describe the function of residential heating systems.

2.  Describe the common heating fuels (gas, oil, propane, electricity, wood).States GAS above ??

3.  JDG

3.    Describe the combustion process with reference to the fire triangle, combustion air, ignition, and venting.

4.    Describe three methods of heat transfer(radiation, convection, conduction) and how each apply to residential heating systems.

5.    there is none.

6.    Describe the common types of heating equipment (furnaces, hot water boilers, steam boilers, space heating, radiant heating).

7.    List the materials, function and location for the components of a gas fired  forced air furnace including ? fuel delivery system, burner, gas valve, pilot light, thermocouple, combustion air supply, heat exchanger, cabinet, fan (blower, air handler), fan control, high temperature limit switch, thermostat, draft hood, vent connector (exhaust flue, C-vent, B-vent, vent pipe, stack pipe, flue pipe, chimney connector, breeching), filter, electronic air cleaner, humidifier, duct system, registers, grill, induced draft fan, electronic ignition system, condensate handling system, vent damper.

8.    Differentiate between conventional, mid efficiency and high efficiency gas furnaces. Include a description of the normal operating cycle for each.

9.    Describe the features of  adequate installation and repair technique for gas fired forced air furnaces.

10.   Define the following terms with respect to gas fired heating systems: gas pressure regulator, gas meter, drip leg(dirt pocket), flex connectors, combustion air, draft air, dilution air, circulating air, spillage(back drafting, down drafting), natural gas, BTU content of natural gas, monoport burner, multi port burner, cross over igniter refractory (firepot),

Norrmally only in oil fired systems)  JDG gas valve, pilot light, thermocouple, fan/limit switch, heat shield(flame roll out shield), heat exchanger, indirect fired system, direct fired system, draft hood, blower(house fan, furnace fan, air handler, furnace blower), Fan door safety relay.

JDG, up flow furnace, down flow furnace, horizontal furnace, summer switch, fan compartment interlock switch, thermostat, heat anticipator, vent connector, supply plenum, return plenum, filter, supply duct system, return duct system, supply registers, return grills, electronic air cleaner, humidifier, input capacity, output capacity, bonnet capacity, steady state efficiency, seasonal efficiency, steady state losses, off cycle losses, stack effect, AFUE, separation of circulating and combustion air.

11.   Define the following terms with respect to mid and high efficiency gas furnaces: vent damper, intermittent pilot, direct spark ignition, hot surface ignition, flame rectification, natural draft burners, induced draft burners, forced draft burners, pre-purge, side wall venting, sealed combustion, direct vent, mid efficiency, high efficiency, condensing furnaces, latent heat of vaporization, neutralizer, differential pressure switch, heat switch(spillage switch), blower cover interlock, pulse combustion, combination furnaces(water heater and furnace), tempering valve (mixing valve).

12.   Outline the life expectancies for gas fired forced air furnaces.

13.   Identify the codes and standards which apply to gas fired appliances and warm air heating systems in your area.

4.1.2 Inspection Skills for Gas Fired Heating Boilers

Unsafe sidewall vent (C) Carson Dunlop Associates

1.    Describe the inspection procedure for conventional, mid efficiency and high efficiency, forced air gas furnaces.

2.    Identify the following common defects listed on the next page.

3.    Describe the implication of each defect.

4.    Identify safety issues for the inspector and occupant of the house (gas explosion, carbon monoxide poisoning, injury due to moving parts).

5.    Communicate findings to client verbally and in writing, recommending corrective action where needed.

Sketch above of a pulse furnace heat exchanger is provided courtesy of Carson Dunlop Associates & appears in their Home Reference Book.

GAS Burner for Boilers: TYPICAL DEFECTS

Gas Burner & Venting Defects

Gas Meters, Defects, Visible or by Testing

Heat Shield Defects on Gas Boilers, Heaters, Furnaces

Venting System Defects, Gas Fired Heaters

 Gas Fired Heater Piping Defects

Mid & High Effficiency Gas Heaters: Boilers, Furnaces

Gas Fired Boilers or Furnaces: Combustion Air Defects

Gas Burner Inspection Points & Defects


4.3 Hot Water Heating Boilers, Typical Defects Lists

(Burners are not covered in this section since they have been covered earlier)


4.3.1 Knowledge Base for Gas Fired Boilers


1.    Describe the function of a hot water (hydronic) heating system.

2.    Describe open and closed heating systems.

3.    Describe four types of distribution piping (series loop, 1-pipe system, 2-pipe system - direct return, 2-pipe system - reverse return).

4.    List the materials and components of a typical hot water heating system including fuel storage and supply system, burner, combustion air supply, venting, cabinet/body, heat exchanger, controls, expansion tank, pump (circulators), pipe, radiator, convector, baseboard, radiant heating.

5.    Describe the features of  adequate installation and repair technique for hot water heating systems.

6.    Outline the advantages and disadvantages of hot watering heating relative to forced air heating.

7.    Outline the differences between boilers and furnaces, including the normal operating cycles.

8.    Define the following terms with respect to hot water boilers: convection, conduction, radiation, super heated water, pressure relief valve, high temperature limit switch, low water cut-out, backflow preventer, pressure reducing valve (automatic  water makeup), automatic air vent, primary control pump(circulator), zone control, outdoor air thermostat, flow control valve, isolating valve, tankless coil, radiator bleed valve, radiator control valve, air separator (air scoop), aquastat, open expansion tank, closed expansion tank, diaphragm (bladder) expansion tank, side arm heater, indirect water heater, mixing valve(tempering valve), condensing boilers.

9.    Outline the life expectancies of boilers made of various materials.

10.   Identify the codes or standards which apply to hot water heating systems in your area.


4.3.2 Inspection Skills for Gas Fired Boilers


1.    Describe the inspection procedure for hot water heating systems.

2.    Identify the following common defects listed on the next page.

3.    Describe the implication of each defect.

4.    Identify safety issues for the inspector and occupant of the home (steam explosion, combustion product poisoning, electric shock, physical injury).

5.    Communicate findings to client verbally and in writing, recommending corrective action where needed.

HOT WATER BOILER TYPICAL DEFECTS

Gas Fired Boiler Heat Exchanger Defects

Room Thermostat Defects - Gas Fired Hot Water Heat

Boiler Cabinet Defects

Gas-Fired Boiler Air Vent Defects

Hot Water Heating Circulator Pump or Relay Defects - Gas Fired Heating Systems

Gas-Fired Heating Boiler Expansion Tank Defects

Gas-Fired Heating Boiler Primary Control Defects

Gas-Fired Heating Boiler Isolation Valve Defects

Gas-Fired Heating Boiler Pump Control Defects

Gas-Fired Heating Boiler Pressure Relief Valve Defects

Gas-Fired Heating Boiler Zone Control Defects

Gas-Fired Heating Boiler Outdoor Air Defects

Gas-Fired Heating Boiler High Limit Switch Defects

Gas-Fired Heating Boiler Flow Control Valve Defects

Gas-Fired Heating Boiler Low Water Cutoff Control Defects

[not required in all jurisdictions]

Gas-Fired Heating Boiler Isolation Valve Defects

Gas-Fired Heating Boiler Backflow Preventer Valve Defects

Gas-Fired Heating Boiler Pressure Reducing Valve / Water Feed Valve Defects

Mid & High Efficiency Gas-Fired Heating Boiler Defects

Hot Water Heating Piping Defects on Gas Fired Heating Boiler Systems

Gas-Fired Heating Boilers & Radiant Heating Systems

Gas-Fired Hot Water Heating Radiators, Convectors, Baseboards: Defects

Tankless Coil on Gas-Fired Heating Boiler, Defects

These curriculae and building defect lists are based on smilar curriculum documents first prepared by Joe Scaduto, an ASHI member who prepared course material for Northeastern University's Building Inspection Certificate program in 1988, subsequently by DF, InspectApedia's editor, for New York University ca 1988 and later, with others, recommended to ASHI, the American Society of Home Inspectors. ASHI did not adopt this material though currently that association as well as others offers other material

The curriculum and lists of defects are informed by additional analysis of the process of home inspection that was developed beginning Calgary, AB for Canadian and U.S. home inspector education and certification examinations in 1997. Other early contributors to home inspection education in the U.S. and Canada include Dr. Jess Aronstein, Alan Carson, Mike Casey, Mark Cramer, John Cox, Dwight Barnett, Douglas Hansen, Rick Heyl, Larry Hoytt, Bill Merrill, Kevin O'Malley, Dennis Robitalille, Keith Peddie, Pat Porzio, Roger Robinson.

Watch out: these inspection lists do not list all possible defects for the systems discussed, and not all home or building inspectors will examine all of the items listed here.


...

Continue reading at BOILERS, HEATING or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Recommended Articles

Suggested citation for this web page

DEFECTS LIST - HEAT BOILER GAS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to BUILDING & HOME INSPECTION

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Share this article:

Search the InspectApedia website

Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.

Citations & References

In addition to any citations in the article above, a full list is available on request.



ADVERTISEMENT