Building Inspection, Diagnosis & Repair Info

Building Exterior Structural Defects List & Home Inspection Education

This article lists significant building structural defects visible from outside, including definitions of common structural defect terms, and related home inspection education topics.

This article series, beginning at BUILDING DEFECTS LISTS, provides lists of common building defects and basic defect knowledge that also outline recommended curriculum content for home inspector education.

The building defects and inspection points listed in these articles also guide homeowners and home buyers to building areas that merit careful attention and often point areas of safety concern or important maintenance and repair tasks.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?





ADVERTISEMENT





Home Inspection Education Curriculum - Exterior Roof Structure Inspection

7.2   Exterior structures: inspeting for defects


7.2.1 Knowledge Base


1.    Describe the function of exterior structures including porches, decks, balconies, garages and carports, basement walk-outs.

2.    List the materials and components of each of the structures listed above.

3.    Describe the features of  adequate installation and repair technique for each of the structures listed above.

4.    Define the following terms:

Porch, deck, balcony, eaves, steps (rise, run, tread, landing, wood/soil contact, handrail, guardrail), cantilever, ledgerboard, gasproofing garages, fireproofing garages, man-door on garage, auto closer on garage door, pressure grouting, mud jacking, vehicle door on garages, counter-balance on garage doors, auto reverse on garage door openers.

5.    Identify the codes or standards which apply to exterior structures in your area.


7.2.2 `Inspection Skills:


1.    Describe the inspection procedure for all the exterior structures listed above.  Include testing of auto reverse mechanisms for overhead garage doors.

2.    Identify the common defects listed on the next page.

3.    Describe the implication of each defect.

4.    Identify the safety issues for the inspector and occupant of the home (fall hazard, trapping children under garage doors, trip hazard on stairs).

5.    Communicate findings to client verbally and in writing, recommending corrective action where needed.



EXTERIOR STRUCTURE TYPICAL DEFECTS

BEAMS

• End support inadequate

• Rot, insect damage, wood/soil contact

 • Rotation

  • Sag

JOISTS

• Cantilevered joist problems

• End bearing inadequate

• Fastener problems

• Ledgerboard problems

• Rotation

• Sag (undersized, overspanned, damaged, overloaded)  missing  JDG


PORCHES, DECKS AND BALCONIES

STEPS AND LANDINGS                       


• Carpet over wood steps or landing      

• Landings missing or undersized               

• Masonry or concrete spalling or cracking    

• Rot                                   

• Stair rise too big or not uniform

• Stair run too small or not uniform                

• Steps slope

• Steps or landings settling or heaving        

• Steps spring, loose or sagging               

• Tread widths too small or not uniform        

• Wood/soil contact                            

• Rot, insect damage or wood/soil contact

FLOORS

• Carpet

• No step up into house

• Poor quality materials

• Rot, insect damage or wood/soil contact

• Sag

• Rot, insect damage or wood/soil contact

HANDRAILS AND GUARDS         

• Loose

• Missing                                

• Rot

• Spindles missing, too far apart, climbable   

• Concrete cracked or spalled

• Rust

• Mechanical damage

 • Paint or stain needed

COLUMNS                                  

• Paint or stain needed

• Leaning, settled, heaved                     

• Rot, insect damage                     

• Rust                                         

• Spalling, cracked or damaged                 

• Wood/soil contact

SKIRTING

See Mobile Homes & Manufactured Homes

ROOF STRUCTURES

• Fastener problems

• Mechanical damage                      

• Rot, insect damage                    

• Settlement or other movement                 

Also see HOME & BUILDING INSPECTORS & INSPECTION METHODS. Use the Search Box at the top or bottom of these pages to find in-depth information about building, energy savings, and indoor environment inspection, diagnosis and repair at this website.

Watch out: these inspection lists do not list all possible defects for the systems discussed, and not all home or building inspectors will examine all of the items listed here. CONTACT us to suggest corrections or additions to articles at this website.

FEAR-O-METER: Dan's 3 D's SET REPAIR PRIORITIES a promotion theory to convert risk of hidden defects & hazards into action thresholds, for a discussion of how an accumulation of inspection evidence leads to a rational decision to perform invasive or desctructive inspection measures.

These curriculae and building defect lists are based on smilar curriculum documents first prepared by Joe Scaduto, an ASHI member who prepared course material for Northeastern University's Building Inspection Certificate program in 1988, subsequently by DF, InspectApedia's editor, for New York University ca 1988 and later, with others, recommended to ASHI, the American Society of Home Inspectors. ASHI did not adopt this material though currently that association as well as others offer extensive HOME INSPECTOR EDUCATION material. The curriculum and lists of defects are informed by additional analysis of the process of home inspection that was developed beginning Calgary, AB for Canadian and U.S. home inspector education and certification examinations in 1997. Other early contributors to home inspection education in the U.S. and Canada include Dr. Jess Aronstein, Alan Carson, Mike Casey, Mark Cramer, John Cox, Dwight Barnett, Douglas Hansen, Rick Heyl, Larry Hoytt, Bill Merrill, Kevin O'Malley, Dennis Robitalille, Keith Peddie, Pat Porzio, Roger Robinson.


...

Continue reading at ARTICLE INDEX to BUILDING DAMAGE, DISASTER, REPAIR or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Recommended Articles

Suggested citation for this web page

EXTERIOR STRUCTURAL DEFECTS LIST at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to BUILDING & HOME INSPECTION

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Share this article:

Search the InspectApedia website

Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.