Trianco Boiler Manuals, Parts Lists, Wiring Diagrams
Manuals, parts lists, wiring diagrams for Trianco Boilers.
This website proides free downloadable copies of installation and service manuals for heating, heat pump, and air conditioning equipment, or contact information for the manufacturers who can provide that information for nearly all major brands of HVAC equipment., heat pumps, and heating equipment from a variety of manufacturers as well as contact information to obtain the exact manual or wiring diagram for your unit.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
In the U.K. Trianco produces and sells several types of heating boilers including electric, oil-fired, wood pellet, and coal boilers. The company's headquareters are in Sheffield, England. The company has been in business in the U.K. since its founding at Thorncliffe circa 1855, re-named to Triancco Heating Company in 1972.
The company's current product lines are Aztec (electric boilers - shown here), Contractor, Eurostar oil-fueled boilers (shown at page top), Greenstar or Greenflame (wood pellet-fueled heating boilers), TRG (solid fuel boilers).
The company also provides both residential and Commercial HVAC airsources (air-sourced heat pump equipment) for heating and hot water.
Under this name, the 1940s and 50s saw the company pioneer domestic oil fired boilers and it was probably the first with an oil combi. In the early 1970s they acquired Trianco Stewart, a small oil boiler manufacturer, and thus Trianco was born.
A management buy out followed in 1983 and then, in 1995, the company became part of the Bullough Group and subsequently Union Investment (a merchant bank based in London)
Trianco U.S. includes a number of heating systems: 9600 HWG/CB, Endurance EPB/EDP, H & HP Boilers, HW series boilers, and Teledyne Lars heating equipment and parts.
Trianco Boiler Company is headquartered in the U.K.: Trianco Heating Products Limited, Thorncliffe, Chapeltown, Sheffield, S35 2PH, England. Tel: +44 (0) 114 257 2300 Fax: +44 (0) 114 257 1419
...
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
I have an older Trianco (blue) boiler ,house is 30+ yrs old. Unknown if original boiler.
Kept losing hot water volume (running out after 1-3 minutes).
Dont hear furnace coming on when hot h20 is called for. It does have a newer mixer inline installed Aug 2015.
Have only light warm water when called for 5 secs then just called/furnace doesnt fire.
Dont have large iron an mineral water content in NH.
My intent at this point is a sulfuric acid bath of coil. ,remove clean the mixer valve. Not sure if control box needs change or not.? Thoughts?
email...flipzhd@hotmail.com thks On 2017-04-16
by flipzhd
by (mod) - what to check if you're running out of hot water from your Trianco boiler.
Flip
When your domestic hot water supply (washing / bathing) is from a tankless coil and water quantity runs out more quickly I would look at the boiler temperature first.The fact is no tankless coil hot water system will give endless hot water, as the rate at which heat is removed from the boiler by the coil is faster than the oil burner can put heat in.
That's because the rest of the boiler/heating system was designed to heat the home not to heat a tankless coil.
A mixing valve gives the appearance of more hot water because it meters out the hot water more slowly, mixing in some cold.
1. Check the boiler aquastat settings, and use the InspectApedia search box at the top or bottom of any Inspectapedia.com page to find our article on RECOMMENDED AQUASTAT SETTINGS to see where they should be
2. Check that when the boiler temperature is below the LO on the aquastat the burner is firing; if it's not the system needs service/repair, and yes the control or its temperature sensor could be defective.For de-clogging your tankless coil
see CLOGGED TANKLESS COIL or PIPES, LIME SCALE
See TANKLESS COIL HOT WATER INCREASE If you need to improve the hot water temperature and flow from a tankless coil system that is not clogged
We have an Aztec electric boiler which is working. However we have hot water but no heating. I'm pretty sure it's something to do with the tank. Not sure whether to turn the pressure tap? On 2016-02-26 by Sam
by (mod) - Aztec electric boilers are distributed by Trianco
Sam,
Aztec electric boilers are distributed by Trianco - here is their UK website: http://www.trianco.co.uk/
You need the boiler model number to find the proper manual for your unit.There you'll see some diagnostics for cases where the heat is not working.
Some Tiranco heating units include diagnostic lights that help determine the trouble.
For example the Trianco CLASSIC 2, 6, 9, 11 & 12KW BOILER manual includes a diagnostic flow chart for "No Heat" where you'll see that the repair steps depend on which light is on: solid green, flashing red, permanent red, or no green. Problems range from a control board to a burned-out element.
Or see the diagnosis and repair steps I describe
...
Continue reading at MANUALS for HEATING & A/C SYSTEM CONTROLS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
TRIANCO BOILER CONTACT INFO & MANUALS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Or see
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
If you posted comments here and no longer see what you wrote, please check for your comment in the Reader Q&A found above on this page.
In addition to any citations in the article above, a full list is available on request.