What can cause my zone 2 thermostat to go blank?
I have a 2 zones heating/cooling. Evrytime the heating srart in zone 2 the zone 2 thermostat (this is connected directly to power) goes blank.
When the heating stop the zone 2 thermostat turn back on.
My zone 1 work fine.
What can cause my zone 2 thermostat to go blank?
Thank you On 2018-11-22
by Andre
by (mod) - When heating starts in zone 2 the zone 2 thermostat (this is connected directly to power) goes blank
Andre,
Thank you for asking interesting question. That's a condition that I have not encountered. Normally when a thermostat display goes blank it's because there's a loss of power to the device. I would start by checking the electrical connections on both ends of the thermostat circuit.
As a very speculative guess, it's also possible that a low voltage Transformer on your system is overloaded, that is being asked to power too many devices.
155.00 error code on my thermostat
I have a 155.00 error code on my thermostat and my outside unit will not communicate with the air handler. Anyone know what the code 155.00 is? On 2018-11-18 by Brian
On 2018-11-19 by (mod) - thermostat 155.00 error code
I would like to help Brian, but unfortunately error codes are not Universal across all brands and models of thermostats.
You need to identify the brand and the model and then get ahold of the owners manual or we can look up the error code.
For example here is just one manufacturer's error code translatoor:
TRANE ComfortLink™ II SYstem Heat Pump Service Facts and ERROR CODES [PDF], (2011) Trane Corporation, Website: www.trane.com
Our free HVAC downloads of service and operating manuals for all brands can be found at MANUALS & PARTS GUIDES - HVAC - home - Master Index to All Brand Names & HVAC manuals, wiring diagrams, installation and repair guides
On 2018-06-13 by Christian
The 120V 20A circuit breaker that powers my thermostat, and I believe the 120V side of the HVAC keeps tripping. This causes the A/C to not work because the thermostat has no power. I can reset the circuit breaker and everything works fine, and 2-3 days later it trips again. Where should I start looking, in the HVAC contactor?
The circuit breaker is tripping even though the fan motor sounds fine, and works fine. The connections all seem good. It is a Lennox 80HUF gas furnace and blower. Could it be the circuit breaker?
On 2018-06-14 00:59:15.618525 by (mod) -
Christian
When a breaker keeps tripping it could be the breaker but usually it's a short or a failing component.
If your electrician simply swaps wires between two breakers of the same amperage rating in the panel, and if the thermostat circuit trips the new breaker that's a pretty good diagnostic.
System shuts down on call for heat - trips breaker?
I have a hydro air system with Trane air handlers and slow-close Taco zone valves. On one of the zones, the cooling side and the fan work OK.
When the thermostat (Ecobee 4) calls for heat, I hear the blower come on for a second and then the entire system shuts down and resets (including the thermostat which is powered by the air handler).
Any ideas? I'm pretty sure the thermostat is operating normally. On 2018-05-21 by Mooneydriver -
Reply by (mod) -
I'd look for an overcurrent tripping a breaker first. Is there a separate blower or zone damper motor or other motor that could be giving trouble>?
I have a Beutler Heating and A/C. not working properly: downstairs thermostat turns on upstairs heat
Ok, I did not see my issue listed above. I have a Beutler Heating and A/C. I live in a two story house and have a stat (TS40B) both upstairs and downstairs.
There are supposed to be two working zones. One for upstairs and the other for the downstairs.
The upstairs stat will not allow me to turn on the heat or A/C.
The digital display is working, but there are not a few options missing from the stat that used to be there, and can be found on the stat downstairs.
The upstairs stat says "Econ Sys Off", and there is no longer a "hold" selection. I swapped the stat control on the wall, and the problem still appears to be the same upstairs (no change).
The downstairs stat turns on both the A/C and the heater, but here is the catch.
The downstairs stat turns on the A/C and heater upstairs. The heater will run continuously since it is not changing the temperature downstairs. Any ideas? On 2018-01-27 by Chris Morrow
by (mod) - contact Beutler Air Conditioning and Plumbing
Chris
What you describes sounds like a wiring error or shorted thermostat wires.
Beutler is not a brand I recognize, though there is a service company with that name. If this is close to you I'd give them a call:
Beutler Air Conditioning and Plumbing
855 National Drive, Suite 109
Sacramento, CA 95834
Tel: (916) 696-8711
On 2018-01-18 by Anonymous
My Ac unit is set at 90% but my house temperature is only 64 what could be the problem i need more heat its cold
On 2018-01-18 by (mod) -
Anon
Assuming that your AC unit is also a heat pump that is supposed to be giving you heat, it may be that outdoor temperatures are too low for your heat pump to work and your backup heat is not working.
Start at HEAT WON'T TURN ON https://inspectapedia.com/heat/No-Heat-Diagnosis.php as you've already said your thermostat is set to 90 degrees (not %) and it sounds as if you're not getting heat.
The room temperature never seems to climb
Hi All,
I have a natural gas hot water boiler heat system, an Utica PGB125, and do not have an air system in house, just heat only system.
I recently replaced my old round honeywell thermostats with new digital Honeywell thermostats.
I have a Honeywell RTH2400 in my living room that controls one side of my house (living room, sunroom, kitchen, & laundry room) and a Honeywell RTH2300 in the bedroom that controls (2 bedrooms and the bathroom).
I have programmed the thermostats to 80 degrees, but I can’t get the living room above 73 and the bedrooms above 69 degrees.
The boiler does kick on and circulate and heat comes out of registers, but the room temps never seem to climb. Thermostats only had a two wire hook up On 2018-01-14
by Shawn
by (mod) - Honeywell RTH2400 and a Honeywell RTH2300
Shawn
It does not sound to me as if this is a thermostat problem. If the heat continues to run but room temperature never reaches the thermostat set point then the thermostat is doing its job - asking for heat.More likely there is a boiler temperature problem, a circulator flow problem, or the combination of an unusually high (80 degF) thermostat setting combined with very low outdoor temperatures and the rate of heat loss from your building exceeds the heating system's capability.
...
Continue reading at THERMOSTAT DIAGNOSTIC GUIDE or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
THERMOSTATS, DIAGNOSTIC FAQs-4 at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
In addition to any citations in the article above, a full list is available on request.