Barometric damper in chimney (C) Daniel Friedman A Catalog of Methods to Inspect the Interior of Chimneys & Flues

Catalog of chimney interior flue inspection methods & techniques:

This article describes various methods that can be used to make a visual inspection of the interior of a chimney flue. Inspection methods taking advantage of existing openings such as at barometric dampers or chimney thimbles and cleanout doors can tell a lot about the condition of a chimney interior even though a complete view of the entire flue is not available.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?





ADVERTISEMENT





Methods Used to Inspect the Chimney or Chimney Flue Interior

Described in this article are more readily-accessible ways to inspect portions of the chimney flue interior by eye.

Also see CHIMNEY FLUE INSPECTION CAMERA for a discussion of chimney inspection camera systems.

While none of these methods is comprehensive, valuable information can be easily obtained by putting two and two together combining visual clues about a chimney.

Photograph of a damaged unsafe brick chimney in an attic.We recommend that you have any questionable chimney inspected by a professional and if necessary, make use of a remote camera and lighting to complete a detailed examination. But you can also make use of the methods we describe in this article.

 

First, Some Simple Indoor Clues Can Suggest Very Serious Chimney Hazards

Odors

from a chimney or from heating equipment, high levels of indoor moisture, trouble keeping a gas burner going, rust on top of a heating appliance are examples of indoor observations that could indicate a very dangerous blocked chimney even before the homeowner or home inspector has approached the chimney itself.

Evidence of flue gas spillage

may be easy to spot, especially with gas-fired equipment. For example, the rust on the top of this gas-fired heating boiler was from a long history of spillage from the boiler's draft hood.

The flue gases were spilling out of the draft hood because the chimney was blocked by fallen bricks which had jammed up in the flue right above the thimble for the boiler. The bricks had fallen from loose masonry up in the attic - as we showed by photos just above.

The homeowner contacted us to ask for a diagnosis of the high level of water found on basement walls, not because she suspected an unsafe chimney and indoor carbon monoxide hazards.

Chimney Flue View by Barometric Damper or Flue Vent Connector and Thimble

Masonry flue interiors:

It may be possible to obtain a limited view of the chimney interior by looking through the hinged door of a barometric damper, flue vent connector (disassembly required) or thimble (disassembly required), or where no flue vent connector is installed, if you find a cover closing off a previously-used chimney thimble, such as the old spring-loaded metal "pie plate" chimney thimble covers, it may be possible to inspect the chimney interior through those openings.

You may not be so lucky as to find a barometric damper giving view directly into the chimney flue (photo at left) but check to see if the draft regulator on a heater or water heater gives view into the chimney.

This damper location, built right into a chimney works properly only if just a single appliance is vented into this flue.

Also see DRAFT REGULATOR, DAMPER, BOOSTER.

Metal chimney flue liners

have to be inspected by removing the vent connector from the chimney breach to check for corrosion. Sight up the liner with a mirror to check straightness, rust, holes, heavy creosote, leak evidence, and for metal flue blockage.

Metal chimney flue interiors & metal chimney liners

have to be inspected from the chimney top and inside by removing the vent connector from the chimney breach to check for corrosion. Sight up the liner with a mirror to check straightness and for blockage.

Even when a home inspector cannot see much of the chimney flue through such a limited access opening, certain observations can be critical, such as:

Chimney Thimble Requirements

A chimney thimble is a sleeve embedded in the chimney wall designed to accept the flue connector from an appliance. They must be placed with the chimney end flush with the inside wall of the flue lining and cemented in place with the refractory mortar used in the flue tiles.

Chimney Thimble Damage and Safety Concerns

The thimble is the masonry or clay or insulated metal sleeve that provides an entry passage for a metal flue vent connector to enter a masonry chimney.

The most common defect we see at the chimney thimble is failure to seal the metal flue at the entry to the chimney flue.

A broken or short thimble can allow combustion gases to rise in the air space between the flue liner and the masonry surround. Condensation stains will often appear in the mortar joints and as streaks running down the exterior face of the chimney. Wood or oil burners leave soot that leaches out as black streaks.

Readers of this article should be sure to

review FIREPLACE DAMAGE & UNSAFE HEARTHS, and also

see FIREPLACE INSPECTIONS for a professional chimney sweep's fireplace and chimney hazard checklist.

at FIREPLACE INSERTS INSTALL, INSPECT, REPAIR we discuss fireplace inserts and zero-clearance fireplaces, both antique and modern, and their hazards and inspection limitations.

Readers should also

see INACCESSIBLE CONNECTIONS FIREPLACE, WOODSTOVE. The inspection of chimney interiors is discussed

at CHIMNEY INSPECTION, FLUE INTERIOR.

...




ADVERTISEMENT





Reader Comments, Questions & Answers About The Article Above

Below you will find questions and answers previously posted on this page at its page bottom reader comment box.

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs

Reader Question: (Aug 12, 2012) John said: I am getting a pale, sand colored, crystalline buidlup around the joints of my less than one year old I metal flue liner and the stuff has even dripped onto the top of the oil burner box which is also less than a year old. Looking through the flue damper, which is right next to the base of the chimney, I see only rust, which I am also not happy about. What is this stuff and how is it getting into my flue? Thanks

Reply: John, it sounds as if there is a condensation or leak problem in that chimney or the flue vent connector as well as deterioration. If the metal "flue" you describe is the actual chimney I'd ask a certified chimney sweep to inspect, clean, repair the system. Else it may be unsafe. If the metal flue you describe is actually the connector betweeen the heating appliance and the chimney, that's a job for your heating service technician.

Question:

(Oct 28, 2011) mark daniels said:
my 8"round chimney thimble is broken off flush with the concrete block and im trying to install a pellet burning stove how can i fix the thimble? cani add to the thimble?

Reply:

(Nov 2, 2012) rodney calhoun said:
im replacing a mortat cap on a large hollow with only 2 clay flue liners should their be bore brick around liner


...

Continue reading at CHIMNEY FLUE INSPECTION CAMERA or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see CHIMNEY INSPECTION DIAGNOSIS FAQs - questions and answers posted originally here on this page.

Or see these

Recommended Articles

Suggested citation for this web page

CHIMNEY INSPECTION, FLUE INTERIOR at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to CHIMNEYS & FLUES

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Share this article:

Search the InspectApedia website

Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.

Citations & References

In addition to any citations in the article above, a full list is available on request.



ADVERTISEMENT