Chimney Safety AlertWood stove & chimney clearance safety:
This article provides woodstove chimney and flue safety advice from the U.S. CPSC in an expanded, illustrated version.
Because most wood stove-related house fires are traced to unsafe wood stove chimney or flue installations, these safety warnings, installation and chimney installation and inspection advice are important to anyone using a woodstove (or coal stove) in their home.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
"In 1982, wood-burning appliances accounted for more fires, more fire deaths, and greater property damage than any other kind of heating fuel -- about 140,000 fires, 250 deaths and $257 million in property damage.
These losses represented 20 percent of all residential fires in the U.S., 5 percent of all fire deaths, and 8 percent of estimated property damage." -- CPSC Chimney Safety Document #5017.
Whether your heater is a woodstove, coal stove, or even a gas fired free-standing stove or heater such as shown in the photo above showing a church heater, a fire-safe installation includes respecting the necessary clearances from combustibles and other measures too.
CPSC research indicates that most wood heating fires involve the chimney and not the appliance itself. The majority of these fires are contained within the chimney and cause no damage to the house.
The Commission
is concerned, however, not only about the chimney fires that did ignite other
parts of the house, but also about the potential future hazard from the
continued use of chimneys whose structural integrity has been compromised by a
chimney fire. This is especially true in light of the fact that many contained
chimney fires are not reported to the fire services; in fact, consumers may not
even be aware that a chimney fire has occurred.
Therefore, the Consumer Product Safety Commission is issuing a special safety
alert concerning chimneys used with wood burning
stoves, fireplaces, and fireplace inserts. The Commission urgently warns
consumers to be aware of the potential fire hazards associated with these
chimneys.
Now that the nation has entered the heating season, the Commission strongly
urges you, if you have a stove or fireplace, to check the chimney for any
damage that may have occurred in the past heating season. If it is difficult to
examine the chimney, a local chimney repairman, chimney "sweep," or
dealer can help. Have any damage repaired NOW.
Most fires involving either masonry or prefabricated metal chimneys occur
because of improper installation, use or maintenance. The Commission staff has
identified the following common causes of fires:
Structural damage to metal prefabricated chimneys that results in wood framing being exposed to excessive temperatures or leakage of potentially toxic gases to the interior of the home can take the following forms:
Structural damage also occurs
in masonry chimneys, often associated with deterioration or improper
installation of the chimney. The tile inner liner and the surrounding brick or
block structure may crack and separate, perhaps as a result of the ignition of creosote
that has built up in the chimney. Many old chimneys do not have a tile liner.
If your chimney does not have a liner, the addition of a properly installed
liner is advisable. Also, a clay liner should be sealed with refractory cement.
Even when the heating appliance is properly installed, people with either metal
or masonry chimney systems should frequently check the chimney for creosote
deposits, soot build-up, or physical damage.
This involves only a simple visual
examination, but it should be done as often as twice a month during heavy use.
If you see heavy creosote buildup, suspect a problem, or have had a chimney
fire, a qualified chimney repairman or chimney "sweep" should perform
a complete safety inspection. They can arrange for any necessary repairs or
creosote removal, which must be done before the heating appliance is used
again.
There are products now available which, according to recent tests conducted by
independent laboratories, show promise for reducing the production of creosote
and harmful pollutant emissions.
Advance wood stove designs appear to provide more complete combustion of the fuel. Catalytic combustors appear to achieve similar results, and are available with new stoves or as separate components which can be installed between the flue gas exit and the chimney connector of existing stoves.
If you have had a fire or other safety problem with your chimney, or would like additional information, call the Commission's toll-free Hotline 800-638-CPSC.
DF: additional safety advice for people heating with wood stoves or coal stoves can be found
at WOOD, COAL STOVES & FIREPLACES
...
Continue reading at CHIMNEY INSPECTION CHECKLIST or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
CHIMNEY CLEARANCE & CONDITION SAFETY at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
In addition to any citations in the article above, a full list is available on request.