Building Inspection, Diagnosis & Repair Info

Photograph of  this unusual attic air conditioning system is an example of
the range of human creativity observed during a career of building inspections Air Conditioner or Heat Pump System Operating Defect FAQs

A/C or heat pump operating defect checklist FAQs.

This articler series explains how to fix an air conditioner or heat pump that is not operating properly - starting with a simple checkist.

Page top photo: a remarkable do-it-yourself home air conditioning system in the attic of a home inspected by the author: a kiddie swimming pool holds a portable window air conditioner that has been connected to home-made "flex duct" ductwork stolen from a New York city jobsite.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?





ADVERTISEMENT





Air Conditioning System Maintenance & Operating Defect Diagnosis & Repair Guide: defect checklist

Air conditioner or heat pump basic schematic © D Friedman at InspectApedia.com These questions and answers were posted originally

at OPERATING DEFECTS, AIR CONDITIONING - please check out that article.

 

Will increasing the SEER rating 2,3,or 4 points improve efficiency ?

Old house: Local installer said gas heat was added later, air flow not good, want to replace old gas furnace with new gas/electrial AC unit.

Question will increasing the SEER rating 2,3,or 4 points improve efficiency ? On 2016-01-16 by David

by (mod) - Question will increasing the SEER rating 2,3,or 4 points improve efficiency ?

Efficiency yes, airflow perhaps not.

First lets get a correct diagnosis of the problem.

Dirty blower fan, dirty filter, crimped or connected supply duct, inadequate return air, etc.

Fix that and then re evaluate

Outdoor Cooling Unit won't come on at all

My thermostat and fan are working fine. Air blows through the vent but the house never cools to temp.

The outdoor unit has not come on at all - it is making no noise whatsoever. Reset blower/furnace switch, checked over flow, no condensation being drawn out of the air through the lines.

Getting ready to check to see if I buy new fuses (pull-outs) if that will solve the problem

What else should I look for next? I am not even sure if I can tell if a fuse is blown. I have two pull-outs with two fuses each... not sure how much they cost. Just had gas added last year and cleaning, service.

The unit is not that old, estimated at 8-10 years. On 2012-05-29 by anon

Reply by (mod) -

Outdoor:

If the outdoor unit is never coming on your system will not produce cool air. That's because no refrigerant is being condensed to liquid form for routing to the cooling coil inside your indoor air handler.

Make sure the compressor condenser has power, that your thermostat is in COOL mode and is calling for cooling. If the compressor condenser unit (the outdoor unit) makes no sound at all it may have no power or there could be a bad switch or relay.

Complete diagnostics are at LOST COOLING CAPACITY (article link in our ARTICLE INDEX)

Air Conditioner Condensate water dumps into a bucket at our air conditioner

Help, we have had out unit "fixed" each summer. We have tons of water coming out of our overflow pipes, instead of coming out of the main drains.

It is filling up a 5 gallon bucked with the overflow pipes at least 3 times a day.

They cleaned the whole unit last year, found some blockage, and had to replace the motor fan last year as well.

Frustrating since the unit is a Lennox, and only 5 years old. On 2011-07-19 by Molly

Reply by (mod) -

Molly:

First, your condensate system needs to be one that empties automatically, either by draining by gravity or by using a condensate pump.

Next, it sounds worth looking into why you have so much condensate and whether the amount is really abnormal - it depends on the relative humidity where you live and of course building specifics.

If there were a source of water leaks or humidity in the building that needs correction you'd want to find and attend to that too.

On 2011-07-03 14:59:23.553149 by Carolyn

My air works, then stops and the house heats up. If I turn the air Off, then On, it starts working again. What can I check or do?

Reply by (mod) -

Carolyn: your compressor/condenser may be overheating; check to see that it's airflow is not blocked, it's not too close to the building;

if you can cool down the outdoor unit with a water spray and you see that that gets it going, the system is overheating - could be an installation error (as I just described above) that blocks air flow, or the system compressor could be failing.

Question: Carrier 38 YXA Repair for Outside Unit: breake was tripped

My airconditioner is working on the inside but not working outside...lost its cooling capacity.

When I checked the main panel, the breaker tripped, when I went outside to check on the fan, it wasn't working, removed cover and checked the capacitor,

the "HERM" blew and the blue wire was burnt, the outside switch with the fuse, when checked, 1 fuse blew up.
I changed all the fuses on the outside switch and placed a new run Capacitor..

.I put it back on, the fan started turning but the condenser/compressor just made a humming sound and tripped the circuit breaker again and blew the 2 pieces of fuses on the outside switch...also installed a new contactor but same things happened over and over.

I just don't know what to do anymore. My unit is a carrier 38yxa. 11 years old. Any assistance you can help me regarding this matter is greatly appreciated. (May 14, 2014) james

Reply:

James this is a problem for an experienced hvac tech and a service call. It sounds as if your compressor condenser had a failed compressor motor or possibly a control board or a fan motor.


...

Continue reading at OPERATING DEFECTS, AIR CONDITIONING or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Defects Lists for Air Conditioners & Heat Pumps

Suggested citation for this web page

OPERATING DEFECTS, AIR CONDITIONING FAQs at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to AIR CONDITIONING & HEAT PUMPS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Share this article:

Search the InspectApedia website

Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.

Citations & References

In addition to any citations in the article above, a full list is available on request.



ADVERTISEMENT