  • PASSIVE SOLAR FLOOR TILES, PHASE CHANGE - CONTENTS: use of phase-change floor tiles for passive solar slab design. Sol-Ar-Tile, polymer-resin concrete tiles for floors & ceilings using Colloidal Materials' pouches. Solar Age Magazine Articles on Renewable Energy, Energy Savings, Construction Practices
  • POST a QUESTION or READ FAQs about phase-change floor tiles for passive solar heating systems
  • REFERENCES

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.


Passive solar floor heating using phase change floor tiles:

This article discusses the use of phase-change floor tiles for passive solar floor design



Green links show where you are. © Copyright 2017 InspectApedia.com, All Rights Reserved.

Passive Solar Floor Tile Choices - Phase-Change Tiles

Accompanying text are reprinted/adapted/excerpted with permission from Solar Age Magazine - editor Steven Bliss. Our page top photograph shows a horrible radiant floor slab insulation scheme installed by a Minnesota contractor - this radiant floor system never worked because the tubing was placed too deep in the concrete slab and the insulation system was incomplete.

Floor Coverings for Passive Solar Thermal Mass Floors

The question-and-answer article below paraphrases, quotes-from, updates, and comments an original article from Solar Age Magazine and written by Steven Bliss.

Question:

A few years ago I read about floor tiles with phase-change salts inside their hollow cores for use over thermal-mass slabs in passive solar heating designed homes. An upcoming project I'm involved in could benefit from such a project. Could you please supply me with information on suppliers or manufacturers of phase-change floor tiles for use over insulated slabs? -- Gary Higgins, North Windham ME

Answer:

We mentioned Sol-Ar-Tile™ in Solar Age articles in February 1982 (p.40), and May 1983 (p. 69).

The manufacturer, Ar-Lite Panelcraft Inc., (formerly Architectural Research Corp.), uses Colloidal Material's pouches in polymer resin concrete tiles for floors and ceilings.

Penwalt Corp. produces and packages phase-change materials that can be embedded in floors, ceilings, and walls.

Other articles you'll want to see on passive solar floors, ceilings, and walls, include

The question-and-answer article about use of phase-change materials in passive solar house design, quotes-from, updates, and comments an original article from Solar Age Magazine and written by Steven Bliss.

The link to the original Q&A article in PDF form immediately below is followed by an expanded/updated online version of this article.

...


Continue reading at PASSIVE SOLAR HEAT PERFORMANCE or select a topic from closely-related articles below, or see our complete INDEX to RELATED ARTICLES below.

Suggested citation for this web page

PASSIVE SOLAR FLOOR TILES, PHASE CHANGE at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

INDEX to RELATED ARTICLES: ARTICLE INDEX to SOLAR ENERGY

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia


...

Frequently Asked Questions (FAQs)

Click to Show or Hide FAQs

Ask a Question or Search InspectApedia

Use the "Click to Show or Hide FAQs" link just above to see recently-posted questions, comments, replies, try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Comment Box is loading comments...

Technical Reviewers & References

Click to Show or Hide Citations & References

Publisher's Google+ Page by Daniel Friedman