Building Drains as the Source of Sewage or Septic Odors
Odors from building plumbing drains or traps:
How to troubleshoot sewer or septic odors due to building drain problems: this article explains sewer gas odor troubleshooting for odor sources due to blocked or slow plumbing drains.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
Another indoor sewer gas odor explanation is that there may be a partial blockage and possibly even a leak (photo at left) in a waste line such in a crawl space, below a basement floor, or outdoors between house and septic tank or less likely between septic and fields.
The "glub glub" sound discussed above can also be caused by a partially-blocked drain which is simply slow.
When a building drain is slow due to partial blockage (or bad venting), sewer gases, smells, odors may travel backwards up into the building through the plumbing drain openings.
If the building drain waste vent system has inadequate venting a result may be the loss of water from the building fixture traps. In turn this loss of water from traps permits sewer gases to rise up drain piping and out into occupied space through the building sinks, showers, tubs, and in extreme cases, even toilets.
Don't forget that a loose toilet may itself be an odor source - with sewer gases leaking out around the toilet base. If sewer gas smells are peculiar to a single bathroom we might check for toilet leaks. Even if a toilet seems bolted securely to the floor, its wax ring seal may be damaged, permitting sewer gases and odors into the building.
At FIXTURE vs SYSTEM DRAIN BLOCKAGE we provide steps to diagnose plumbing fixtures as the prime odor sources.
Drain noises due to bad venting or due to a partial blockage will be invariant day or night, depending on drain usage, but in the more quiet still and cool night air, drain noises are more easily heard.
See PLUMBING VENT DEFECTS & NOISES for procedures to diagnose problems with the building drain vent system.
As we said earlier, partially blocked building drain, septic tank, or drainfield can generate odors indoors or outside.
Odors in this case will usually correspond to surges in system use, and odors should not correspond particularly to cold weather, except insofar as cold still air may permit gases to fall (from a plumbing vent stack, for example) , or different seasonal wind patterns may cause gases to move to areas where they're not noticed in warmer weather.
See Using the TIF 8800 Gas Detector for tips on using a gas detection instrument to scan for sewer gas sources in a building.
Also see our broad-scope article on diagnosis and cure of sewer gas and septic odors:
SEWER GAS ODORS for diagnosing, finding, and curing septic tank and sewer line smells.
...
Continue reading at CLOGGED DRAIN DIAGNOSIS & REPAIR or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
BUILDING DRAIN ODOR SOURCES at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
In addition to any citations in the article above, a full list is available on request.