HVAC Air Temperature Measurement
How to measure A/C temperatures: this article describes how to measure input and output air temperatures at air conditioning equipment in order to determine whether or not it is operating properly, as part of checking basic air conditioning system operation and for detection of air conditioning operating defects.
What Instruments Are Used to measure Air Conditioner or Warm Air Furnace Operating Temperatures?
Air conditioner temperatures that are too high or too low can indicate specific operating problems on central and portable or window air conditioners. Simple measurements of air temperatures, if made at the right place, can assist in diagnosing what may be wrong and what repairs may be needed for the air conditioner.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
Dial thermometers such as the dial face shown in the photograph at the top of this page are inexpensive (typically less than $10.00) and very simple instruments which combine a bimetallic spring, a dial face, and a stainless steel probe which can be inserted into A/C systems at key points (below) or in some cases simply held in an air stream.
The thermometer can take a couple of minutes to stabilize, so you should keep it in position until the dial indicator stops changing. Dial thermometers vary in accuracy but can easily be calibrated (using boiling water).
Don't choose a dial thermometer whose temperature range is much greater (say 0 degF. to 212 degF.) than the range that you need (say 30 degF. to 100 degF.) since the smaller range thermometer will be more accurate in determining the temperature.
Digital thermometers work much like a dial thermometer but include a digital display of temperature (and require a battery). Digital thermometers cost a bit more, typically around $25. to $130.
Air flow thermometers are electronic devices similar to a the temperature probes above, but their probe ends in a loop through which air passes to provide a more rapid readout of air temperature. However these devices are not easily inserted into duct work as a larger probe opening will be required.
Infrared temperature measurement devices have the feature of being able to measure surface temperatures from a distance but are not used to make direct measurements of air temperatures
If your air conditioning or heat pump system has lost its cooling capacity or wont' start
see LOST COOLING CAPACITY
and also REPAIR GUIDE for AIR CONDITIONERS
See COOLING CAPACITY, RATED of air conditioning equipment if the system seems to be working but is inadequate to cool your building.
...
Continue reading at AIR CONDITIONER TEMPERATURES or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
HVAC TEMPERATURE INSTRUMENTS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
In addition to any citations in the article above, a full list is available on request.