Painting & FInishing Chapter 20 of BUILD YOUR DREAM HOME
This article series provides an updated version of Hubbard Cobb's Your Dream Home, illustrated by Sigman-Ward, first published by Wm. H. Wise & Co. New York, 1950.
From site selection and obtaining financing through each step in construction of a single family home the simple procedures and drawings in this book are still useful for anyone building or repairing a home or other small structure.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
Chapter 20
Every step in building a house is im- absorbing moisture. There is not quite portant, and painting and finishing is as much rush with interior painting no exception. Woodwork exposed to except for floors, wrhich should be given the weather should be painted just a protective coating of some sort before as soon as possible to prevent it from they are put into use.
|
A good paint job wdll not only protect the outside of your house, but it will also make it more attractive, so take pains writh the selection of your color scheme, the paint you use and the manner in which it is put on. The exterior of the house—that is, any portion that will be exposed to the weather—should be painted with a good grade of exterior paint. Do not take the time and trouble to mix vour v own paints because, in the first place, this is rather tricky work and you may not get a good quality of paint and, second, there are many fine ready-mixed paints on the market that are better than anything you could mix yourself. Be sure that you have good paint brushes; they are as important for the job as is a good paint. |
As a general rule, painting should start at the highest point of the house and w'ork down. If the roof wood shingles are to be stained, this should be done first of all. Stain is easily applied by brush, and the main point is to get it on evenly and to keep it off other woodwork that is to be painted. After the shingles have been done, do the cornice trim, the siding, and then the window' and door trim.
|
|
The first rule to follow for good results in painting is to be sure that the wood is both dry and clean. Do not paint right after rain or during damp weather. Allow the wood to become bone dry before you begin to apply paint. Another point is not to try to paint when the temperature of the air is below 50° F. Below this temperature, paint will not flow properly and the job will not turn out well. The best way to insure that the wood is clean is to wipe it down with turpentine. Rough spots in the wood should be sanded smooth. Knots and sappy spots should be coated with either orange shellac or aluminum paint before the first coat of paint is applied. Unless this is done, the rosin will bleed through the paint after it is dry. The First Coat The first coat of paint, the priming coat, is the most important of the three coats that are required for exterior work. Unless this coat is worked well into the wood’s pores, where it will dry and make a strong bond, the weight of subsequent coats of paint may cause it to pull loose and peel off. The proper thinning of the first coat will depend on the condition of the wood. If the wood is rather green and contains a good deal of rosin and gum, the priming coat should be thinned with turpentine. The turpentine will act on these m |
gums as a solvent and allow the paint to penetrate the pores of the wood. If the wood is very gummy, it might be wise to wipe it down thoroughly with turpentine before painting. On the other hand, if the wood is very dry, the first coat should be thinned with linseed oil to replace the oils in the paint that will be absorbed. The first coat of paint should be worked into the pores of the wood. Do not just flow the paint onto the wood; slap it on and work it in. Many experts feel that the only way to get a priming coat applied properly is by brush. A paint sprayer does not force the paint into the pores as well as can be done by a brush. For the second and third coats, a sprayer can be used if one is available. The Second and Third Coats As soon as the first coat of paint is dry, go over the surface and fill in any holes or nail heads with putty. The putty should not be applied before the first coat goes on because the wood will absorb the oils out of the putty and cause it to drv out and crack or fall out. After the putty is hard, give it a light sanding and then apply the second and third coats. Be sure to allow' ample time between coats for the paint to dry. The exact time required will depend on the weather conditions, but be sure that the paint is good and hard before you go ahead with another coat. The general practice is to paint the siding first and then do the trim around doors and windows. This trim was given a priming coat when it was installed, so only the second and third coats are required for it. In spite of the common practice of painting the trim |
|
a different color than the siding, it is not essential by any means. You can paint it the same color as the siding or you may select any other color that appeals to you. Wood Siding Shingles Shingles used for siding can be stained or painted. The reason that these shingles can be painted while roof shingles cannot, is that siding shingles are not so apt to absorb moisture as roof shingles. Because of the rough texture of shingles, it is easier to apply paint by a sprayer. If you use a brush, use an old one since the rough surface may damage a good new brush. (Shingle stain is applied by brush.) |
Asbestos-Cement Shingles Asbestos-cement shingles can be painted with an oil paint, but you will be better off if you use an asbestos-cement-shingle paint. The reason for this is that it is difficult to be sure that the shingles do not contain moisture and, if they do, using an oil paint on them will turn out badly. The special paints designed for these shingles will not be damaged by moisture either inside the shingles or on the outside surface of the paint itself. Stucco Stucco is best painted with special Portland-cement paints that will not be damaged by moisture and will provide a certain amount of waterproofing for the stucco. |
|
As far as the actual application of the paint goes, brush it on in 1-foot squares, working from the top of the wall down. By covering a small area at a time and working quickly, you will have ample time to join up the sections before the paint around the edges has set. Fig. 3 shows the proper way to hold the brush when you come to painting in the corners. Calcimine is the least expensive finish you can use on a wall, and it can be put on fresh plaster directly after a size has been applied. As far as painting the various wall-boards goes, you do not, of course, have to worry about neutralizing the lime. These products can be painted with an oil paint, water-thinned paint or calcimine just as soon as they are in place. The better types of board do not require any size for calcimine or water-thinned paint but do need one for an oil paint. This size is usually a varnish size. Directions for decorating wallboard are available from your local dealer and should be consulted. When you come to the door casings and the doors, consult Fig. 4, which shows the parts of the casing that should be painted the same color as the door itself. Needless to say, it is not |
necessary to finish all the walls in a house with the same type of paint. For example, it is always best to use an oil paint, such as enamel, in the bathroom and kitchen because here you want a surface that is waterproof and that can be washed easily. In living rooms and bedrooms, calcimine is perfectly satisfactory for the ceiling with a water-thinned paint for the walls or, if you wish something a little more expensive and durable, a water-thinned paint on the ceiling and an oil paint on the walls. Of course, for children’s rooms you need a good, durable and washable surface that only oil paint can supply. |
TV
You will find it a good deal easier to and the holes for the fixtures can be paper walls before fixtures are in- made in the paper after it is in place, stalled. If this is done, the paper can be Wallpaper should not be applied put up with minimum amount of fitting to plaster walls until the plaster is com-
![]() |
|
Fig. 5. Pasted wallpaper folded for convenient handling. Top to bottom: for vertical hanging, top edge at right; for cutting into strips; for horizontal hanging, top edge at bottom; for ceiling hanging, matching edge at bottom. |
|
pletely dry. If the paper is going to be applied to some type of wallboard, the board must first be covered with a fight- weight felt. Strips of felt arc joined |
at the seams with tight butt joints. Plaster walls must be covered with a glue size before the paper is hung. Size for this purpose comes in powder |
form; it needs only to be mixed with water for use. As a rule, ceilings are painted rather than papered, but if you wish to paper the ceilings, they should be done before the walls. You will need some good scaffolding for this job so that you will be able to get the paper up into place with a minimum amount of effort. |
The best method of getting the paper on straight is to draw a line across the ceiling. The distance of this line from the wall should be 2 inches less than the width of the paper. Thus, 2 inches of the paper will fold around the joint between the ceiling and wall and a little way down the wall itself. This overlap will be covered by the strips of paper that are put on the walls after the ceiling has been finished. This procedure will insure that your first strip of paper on the ceiling is parallel with the walls. |
|
After the line has been drawn, measure off and cut a strip of paper. It should be a few inches longer than is required to cover the ceiling so that its ends will extend down along the walls. The self-edges (or selvages) of the paper can now be trimmed off either with scissors or a sharp knife. When you are using heavy grades of paper, a butt joint between sections is necessary, so then both self-edges must be removed. When a lighter grade of paper is used, an overlapping joint can be made, and this calls for the removal of the selfedge from only one side of the paper. After trimming, the paper is ready for pasting. This is done by placing the paper on a clean table with the pattern side facing dowrn. The wallpaper paste is applied with a wide brush and the pasting should begin at the center of the paper and work out to within a few |
inches of the edges. Special care must be taken when pasting the edges not to get any of the paste on the pattern side of the paper. Try moving the paper so that the edge extends a little over the side of your worktable and carefully brush on the paste. The paper can then be folded up, making sure that a pasted surface does not come into contact with a pattern surface. See Fig. 5. The paper is placed against the ceiling and positioned so its outer edge is along the line on the ceiling. The paper is unfolded and smoothed out with a brush. The ends of the paper extending down the walls can be trimmed off and the other sections of paper put on. In papering walls, it is best to drop a plumb line at a point near a window frame, as you may find that in spite of all your efforts the walls and the location of the window frames are not absolutely perfect. The first section of paper is hung to the plumb line and the surplus on the other side can be trimmed off around the window frame. See Fig. 6. Allow at least 2 inches of paper for turning corners. Fig. 7 shows the method of working around angles and the best direction in which to work. Fig. 8 shows how to get the paper to fit around door frames and similar openings. |
As far as the interior woodwork goes, room. The woodwork can be painted the finish used here will depend on the with trim enamel or given a natural quality of the wood and the general finish with varnish, shellac or wax. At-decorative scheme of each particular tractive wood with a natural finish is

Fig. 7. How to paper around corners and the direction in which to work.
|
veiy popular today. If you wish, the wood can be stained with a wood stain to bring out the grain and change the color somewhat. Painting Wood Trim The first step, if you wish to paint the wood trim with an interior trim paint or enamel, is to give all the woodwork a good sanding down with No. 1 sandpaper or steel wool. Dust off the woodwork and then coat the knots and sappy spots with orange shellac or aluminum paint. Now you can apply the first coat of paint. This should be thinned in accordance with the manufacturer’s instructions. Start working at the highest point in the room and work down. After the first coat of paint is dry, fill in any nail holes or flaws in the wood with putty or plastic wood. Give the filler time to dry and then rub the surface down with sandpaper. The second and third coats can then go on. |
Staining Woodwork If the woodwork is to be stained and given a natural finish, it must first be sanded down smooth with No. 0 sandpaper. Dust the surface clean and then apply a stain. There arc many different types of stain that you can use for this purpose, but most amateurs prefer an oil stain. This can be applied to the wood with either a brush or a clean cloth. The edge grain of wood will tend to absorb more stain than the other surfaces and this will make the edges darker. To prevent this from happening, apply a mixture of half-and-half turpentine and linseed oil to the edge grain before you apply the stain. |

Fig. 8. How to fit wallpaper around a covered with paper. In hanging the rest, door. The shaded areas have already been cut and fit the narrow strip firgt.
|
Remember when staining that the longer the stain is allowed to remain on the surface the deeper it will penetrate and the darker will be the wood. Also keep in mind that when stain dries it will be just a little lighter in color than when wet. It is best to stay on the safe side and have the stain too light than too dark. If it is too light, you can always apply another coat. |
The stain should be applied to the wood and after time has been given |
|
for it to sink in, the surplus is wiped off with a clean cloth. Allow twenty-four hours for the stain to dry and then go on to the next step. If you are working with wood that has an open grain, such as oak, elm, chestnut or walnut, a filler is next on the list. Fillers come in paste form and are thinned with turpentine before application. A filler is necessary to plug the pores of the wood so that when the varnish is applied, it will not sink into these little depressions and dry out with a rough surface. Of course, you do not have to use a filler. You can apply the varnish directly to the wood and sand it out smooth after it is dry. But you will find that several coats of varnish will have to be applied and sanded smooth before you have a base suitable for the finish coat. If the wood has not been stained, vou need a neutral filler. If the wood is stained, you need a filler of the same color as the stain or tint that was used on the wood. The filler is applied across the grain and then finished by rubbing with the grain. Allow it to set for about fifteen minutes and then wipe it off with a piece of clean burlap. Wipe across the grain and then with the grain. Give the filler a day to dry and then give the entire wood surface a light sanding. Varnishing Most of the trouble encountered with varnish is the result of the surface’s not being properly prepared. The wood must be absolutely clean, dry and smooth. The temperature of the air |
where varnishing is being done should be around 70°. When the weather is cold, varnish will not flow out properly. When it is too hot, the varnish will dry too quickly. Not only must the wood be dry, but the air around it must not be damp. Do not varnish during damp weather or in the early morning or late evening when dew is falling. The wood should be sanded dowm with No. 00 sandpaper before the first coat of varnish is put on. Flow the varnish onto the surface, working with a full brush at all times. You will probably find that the best way to get the varnish on is to apply it across the grain and then brush it with the grain. Do not try to cover too much area at one time, for if you do, the edges of the varnish may set before they can be joined up with the next section. And do not try to go back over a spot that has alreadv been varnished because once the varnish has set, it will not flow out again and the brush will roughen up the surface. Catch any sags and wrinkles before they have a chance to |
set. Work from the highest point down coats of varnish should be applied and and do the baseboard trim last because each should be sanded down with No. your brush is very likely to pick up 00 sandpaper to produce a smooth some dirt at this point. Two or three finish.
|
Exterior paint, 8 gallons Water-thinned paint, 11 gallons |
Floor enamel, 3 gallons Interior enamel, IV2 gallons |
...
Continue reading at FINISHING the ATTIC & BASEMENT - next chapter in this book, or go to book contents at BUILD YOUR DREAM HOME, or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
PAINTING & FINISHING YOUR HOME at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Or see
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Questions & answers or comments about how to identify the architectural style of buildings and building components
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
In addition to any citations in the article above, a full list is available on request.