InspectAPedia.com InspectAPedia®
Google
InspectAPedia
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US



Mobile Phone/PDA website viewMobile View
SEPTIC SYSTEM INSPECT DIAGNOSE REPAIR
  SEPTIC SYSTEM BASICS
  Septic Guide for Home Buyers or Owners
  Septic or Sewer Connection?
  Septic System Design
  Septic System Designs Master List
  Septic Inspection Testing
  Septic Maintenance Repair
  Septic Component & Product Suppliers
  Septic Videos

ADDITIVES / TREATMENTS for SEPTIC SYSTEMS
AEROBIC SEPTIC SYSTEMS
ALTERNATING BED SEPTIC SYSTEMS

BACKUP PREVENTION, SEPTIC
BACKUP PREVENTION, SEWER LINE
BACKWATER VALVES, SEWER LINE
BIOLOGICAL POLLUTANTS
BOOKS, RECOMMENDED SEPTIC
BOOKSTORE, SEPTIC SYSTEMS

CESSPOOLS
CESSPOOL SAFETY WARNINGS
CHECK VALVES, WATER SUPPLY
CHEMICALS & TREATMENTS for SEPTICS
CHLORAMINE / CHLORINE Tests
CHLORINE IN DRINKING WATER
CHLORINE IN SEPTIC WASTEWATER
CISTERNS
CLOGGED DRAIN DIAGNOSIS & REPAIR

D BOX TROUBLESHOOTING
DEFINITIONS OF SEPTIC SYSTEM TERMS
DIFFICULT SEPTIC SITES
DISTRIBUTION-BOX INSPECTION, SEPTIC
DRAINFIELD FAILURE DIAGNOSIS
DRIVING or PARKING OVER SEPTIC
DRYWELL DESIGN & USES

EFFLUENT RETENTION TIME

FILTERS SEPTIC & GREYWATER
FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
FLOODED SEPTIC SYSTEMS, REPAIR

GARBAGE DISPOSAL vs SEPTICS
GRAVELLESS SEPTIC SYSTEMS
GRAVITY/SIPHON DOSING SYSTEMS
GREYWATER SYSTEMS

HOME BUYERS GUIDE to SEPTIC SYSTEMS
HOME SELLERS GUIDE TO SEPTIC INSPECT

LAGOON SEPTIC SYSTEMS
LEACHFIELD FAILURE DIAGNOSIS

MEDIA FILTER SEPTIC SYSTEMS
MOUND SEPTIC SYSTEMS

NOISE / SOUND DIAGNOSIS & CURE

ODORS & SMELLS DIAGNOSIS & CURE
ODOR DIAGNOSIS CHECKLIST
ODORLESS CHEMICALS / GASES: CHECK FOR?
ODORS, PLUMBING SYSTEM
ODORS, SEPTIC or SEWER
ODORS, SULPHUR SMELL SOURCES
OUTHOUSES & LATRINES

PLANTS & TREES OVER SEPTIC SYSTEMS
PRESSURE DOSING SEPTIC SYSTEMS

RAISED BED SEPTIC SYSTEMS

SAND BED SEPTIC SYSTEMS
SEEPAGE PITS

SEPTIC & CESSPOOL SAFETY
SEPTIC AUTHORITIES, DESIGN REGS
SEPTIC BACKUP PREVENTION
SEPTIC BACKUP REPAIR
SEPTIC BOOK, FREE ONLINE
SEPTIC BOOKSTORE
SEPTIC BIOMATS
SEPTIC CARE INSTRUCTIONS
SEPTIC CLEARANCE DISTANCES
SEPTIC CODES & REFERENCES
  DESIGN MANUALS
  SEPTIC STANDARDS
  SEPTIC MAGAZINES
  SEPTIC BOOKS
  BUY SEPTIC BOOKS ONLINE
  BUY GREYWATER BOOKS ONLINE
  BUY COMPOSTING TOILET BOOKS ONLINE
SEPTIC CONSULTANTS
SEPTIC DRAINFIELD FAILURE DIAGNOSIS
SEPTIC DRAINFIELD INSPECTION & TEST
SEPTIC DRAINFIELD LIFE
SEPTIC DRAINFIELD LOCATION
SEPTIC DRAINFIELD RESTORERS?
SEPTIC DRAINFIELD SIZE
SEPTIC DRAINFIELD SHAPE
SEPTIC DRAWINGS
SEPTIC DYE TEST PROCEDURE

SEPTIC FAILURE LAWSUIT
SEPTIC FAILURE SIGNS
SEPTIC FIELD INSPECTION
SEPTIC FILTERS
SEPTIC FLOOD RESPONSE
SEPTIC HOLDING TANKS

SEPTIC INSPECTION & TEST GUIDE
SEPTIC SYSTEM INSPECTION CLASS
SEPTIC LIFE EXPECTANCY
SEPTIC LIFE MAXIMIZING STEPS
SEPTIC METHANE GAS
SEPTIC ODORS
SEPTIC PUMPS
SEPTIC PUMPING REPAIR
SEPTIC REFERENCES
SEPTIC & CESSPOOL SAFETY
SEPTIC SUPPLIES & PARTS

SEPTIC SYSTEM DEFINITIONS
SEPTIC SYSTEM DESIGN ALTERNATIVES
SEPTIC SYSTEM DESIGN BASICS
  DRYWELL DESIGN & USES
  FILTERS SEPTIC & GREYWATER
  SEEPAGE PITS
  SEPTIC CLEARANCES
  SEPTIC SOIL & PERC TESTS
  SEPTIC TANK SIZE
  SEPTIC TANK DEPTH
  SEPTIC TANK TEES
  SEPTIC DRAINFIELD LOCATION
  SEPTIC DRAINFIELD SIZE
  SEPTIC DRAINFIELD SHAPE
  SEPTIC TANK PUMPING FREQUENCY
  SEPTIC TANK PUMPING PROCEDURE
  SEPTIC SYSTEM PUMPS
  SEPTIC TREATMENTS & CHEMICALS
  STEEP SLOPE SEPTIC DESIGNS
SEPTIC SYSTEM DESIGN MANUAL - Online
SEPTIC SYSTEM, HOME BUYERS GUIDE
SEPTIC SYSTEM INSPECTION & TEST GUIDE
SEPTIC SYSTEM INSPECTION CLASS
SEPTIC SYSTEM INSPECTION LEVELS
SEPTIC SYSTEM ODORS
SEPTIC SYSTEM SAFETY WARNINGS
SEPTIC SYSTEM TYPES, MASTER LIST

SEPTIC TANKS
SEPTIC TANK BAFFLES
SEPTIC TANK COVERS
SEPTIC TANK, HOW TO FIND
SEPTIC TANK GRASS or SNOWMELT
SEPTIC TANK, HOME BUYERS GUIDE
SEPTIC TANK INSPECTION PROCEDURE
SEPTIC TANK PUMPING PROCEDURE
SEPTIC TANK PUMPING REASONS
SEPTIC TANK PUMPING SCHEDULE
SEPTIC TANK SAFETY
SEPTIC TANK SIZE
SEPTIC TANK TEES
SEPTIC TESTS: DYE & LOADING TESTS
SEPTIC TREATMENTS & CHEMICALS
SEPTIC VIDEOS

SEWAGE & SEPTIC CONTAMINANTS
SEWAGE BACKUP, WHAT TO DO
SEWAGE BACKUP TEST & CLEANUP
SEWAGE BACKUP PREVENTION
SEWAGE CONTAMINATION in buildings
SEWAGE CONTAMINANTS in FRUIT / VEGETABLES
SEWAGE EJECTOR / GRINDER PUMPS
SEWAGE LEVELS in SEPTIC TANKS
SEWAGE NITROGEN CONTAMINANTS
SEWAGE PATHOGENS in SEPTIC SLUDGE
SEWAGE PUMPS
SEWAGE PUMP CLOG DAMAGE
SEWER BACKUP PREVENTION
SEWER GAS ODORS
SEWER LINE REPLACEMENT
SMELL PATCH TEST to Track Down Odors
SULPHUR & SEWER GAS SMELL SOURCES
SINKHOLES, WARNING SIGNS
SOAKAWAY BED FAILURE DIAGNOSIS

TOILETS, INSPECT, INSTALL, REPAIR
TOILET ALTERNATIVES
TOILET REPAIR GUIDE
TOILET TYPES
Toilet Types, Flush Methods
TOILETS, DON'T FLUSH LIST
TRAPS on PLUMBING FIXTURES
TREATMENTS & CHEMICALS, SEPTIC

VIDEO GUIDES: Septic Videos

WASHING MACHINES & SEPTIC SYSTEMS
WATER SOFTENERS & CONDITIONERS
WATER SUPPLY & DRAIN PIPING
  CLOGGED DRAIN DIAGNOSIS & REPAIR
WASTEWATER TREATMENT BASICS
WATER, WELLS, WATER TANKS: TESTING GUIDE
WATER PURIFIERS
WATER QUALITY TESTS, CONTAMINANTS, TREATMENT
WATER QUANTITY IMPROVEMENT
WATER QUANTITY USAGE GUIDE
WATER, WELLS, WATER TANKS: TESTING GUIDE
WETLAND SEPTIC SYSTEMS
WINTERIZE A BUILDING

More Information

CLICK for LARGER IMAGE - This illustration shows the stages in soil clogging of a septic
system drain field as the biomat grows from the low-end, up the length and up the sides of the trench.Septic Design Books, Septic Installation Manuals, Septic Standards & Codes, Onsite Wastewater Publications, Septic Journals
InspectAPedia®  -      

  • Septic system & onsite wastewater treatment system example & model codes & regulations
  • Septic system & onsite wastewater treatment system inspection model codes & regulations
  • Septic system books, references & septic design manuals listing and recommendations
  • Questions & answers about where to find septic system design books and building code references

This document lists key septic system design guidelines, codes, manuals, standards, and journals - information about and specifications for conventional and alternative septic systems - onsite wastewater disposal systems. Most of these texts can be purchased online through our InspectAPedia Online Bookstore supported by Amazon.com. The bookstore includes detailed septic book reviews and recommends specific texts.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers nor with topics or services discussed at this website.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

DESIGN MANUALS - Septic Design Books, Septic Standards & Codes, Onsite Wastewater Publications

Septic System Design Manuals & Septic or Onsite Wastewater Disposal System Building Codes

Also see SEPTIC STANDARDS

  • Buyer's Guide Home Buyer's Guide to Septic Systems Inspection & Testing - What to Do, Step by Step.
  • Design Basics for Septic Systems: Choosing Septic Tank Size, Absorption System Size - basic septic system volume and absorption system design guides.
  • SEPTIC DESIGN ALTERNATIVES: Alternate Onsite Wastewater Disposal Designs for Septic Systems - design engineers, consultants, products, books for special problem situations, difficult soils, old system repairs
    Including: AEROBIC Septic systems, chemical toilets, composting toilets, disinfection systems, evaporation/transpiration septics, greywater systems, holding tank septic systems, incinerator toilets, media filter septics, pressure dosing septic systems, raised bed septics, sand filter bed septics, wetland septic treatment systems.
  • US EPA Onsite Wastewater Treatment Systems Manual
  • Inspecting Septic Systems: Online Book, Inspection, Test, Diagnosis, Repair, & Maintenance: Our Online Septic Book: Septic Testing, Loading & Dye Tests, Septic Tank Pumping, Clearances, details of onsite waste disposal system inspection, testing, repair procedures.
  • Soil Percolation Tests soil perc testing, online guide
  • Canada Provincial & Local Septic Codes: (examples)
    • British Columbia Sewerage System Regulations, Standard Practice Manual, Inspection Guidelines provided by the BC Ministry of Health and posted online by BCOSSA British Columbia Onsite Sewage Association, Victoria BC tel: 250-391-8442 email: info@bcossa.com
    • "Manual of Policy, Procedures, and Guidelines for Onsite Sewage Systems," Ontario Reg. 374/81, Part VII of the Environmental Protection Act (Canada), ISBN 0-7743-7303-2, Ministry of the Environment,135 St. Clair Ave. West, Toronto Ontario M4V 1P5 Canada $24. CDN.
  • California State & Local Septic Codes: (examples)
    • City of Calabasas California, Onsite Wastewater Treatment Ordinance & Codes 2009-262
    • City of Calabasas California, Septic & Onsite Wastewater Treatment Inspection Guide 2009- 2010
  • New York State Septic Codes:75-A.0 New York State Regulation of & Design Specifications for Private Septic Systems includes septic system construction details:
    75-A.3 Sewage flows and design flow estimates
    75-A.4 Soil and site appraisal for Septic Systems
    75-A.5 House or building sewer line specifications
    75-A.6 Septic tank capacity requirements, installation, and placement (conventional septic tank and septic drainfield)
    75-A.7 Distribution lines, distribution boxes, gravity flow, pressure distribution, dosing, siphons
    75-A.8 Subsurface treatment of effluent, absorption field requirements, leach field design criteria (conventional septic tank and septic drainfield)
    75-A.9 Alternative Septic System Designs mound systems, raised bed septics, sand filter bed septics, evaporation/transpiration septic systems. others.
  • US EPA's Design Manual for Onsite Wastewater Treatment and Disposal, 1980, available from the US EPA, the US GPO Superintendent of Documents (Pueblo CO), and from the National Small Flows Clearinghouse. This document is now also available online at http://www.epa.gov/ORD/NRMRL/Pubs/625R00008/625R00008.htm
  • US Public Health Service's Manual of Septic Tank Practice, 1959.
  • United States: Pennsylvania: Three septic standards have been developed in "Standards Related to On-site Septic Systems," ISBN 0-8031-1836-8:
    D 5879-95 Standard Practice for Surface Site Characterization for On-site Septic Systems
    D 5921-96 Standard Practice for Sub-surface Site Characterization of Test Pits for On-site Septic Systems
    D 5925-96 Standard Practice for Preliminary Sizing and Delineation of Soil Absorption Field Areas for On-site Septic Systems.
    Inquiries to Staff Mgr Comm. D18 Soil and Rock, ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, voice: 610-832-9500, fax: 610-832-9555, email: service@astm.org
  • International Private Sewage Disposal Code, 1995, sponsored by BOCA - 708-799-2300, ICBO - 310-699-0541, SBCCI - 205-591-1853, available from those code associations.
  • The National Society of Consulting Soil Scientists soil science pointers. Emphasis on locating standards of practice, criteria (like Hydric Soils) and handbooks
  • Onsite Wastewater Treatment Systems, Bennette D. Burks, Mary Margaret Minnis, Hogarth House 1994 - one of the best septic system books around, suffering a bit from small fonts and a weak index.This is one of the best books we've reviewed on the subject, with an excellent balance of clear simple explanation and solid engineering. Topics: Soil & Site Selection, Hydraulics, System Selection & Design, Wastewater Biology, History & Mythology of Onsite Wastewater Treatment. $49.95, Hogarth House, Ltd., 800-993-2665 x327 to order 800 -993-2665 x327 (Univ. Wisc. Bookstore).
    Septic expert Mary Margaret (Peggy) Minnis has an informative website and information about this book found at http://webpage.pace.edu/mminnis/book/
  • The NSFC Products List has an excellent list of design manuals/modules available from their website or by telephone 800-624-8301
  • BUY SEPTIC BOOKS ONLINE
  • BUY GREYWATER BOOKS ONLINE
  • BUY COMPOSTING TOILET BOOKS ONLINE
  • Submissions welcome. send us a suggested document link or request an exchange of website links

SEPTIC STANDARDS - Septic System Onsite Waste Disposal Standards

See DESIGN MANUALS above - we have combined these lists of onsite wastewater treatment references

  • Canada: British Columbia Sewerage System Regulations, Standard Practice Manual, Inspection Guidelines provided by the BC Ministry of Health and posted online by BCOSSA British Columbia Onsite Sewage Association, Victoria BC tel: 250-391-8442 email: info@bcossa.com
  • United States: Pennsylvania: Three septic standards have been developed in "Standards Related to On-site Septic Systems," ISBN 0-8031-1836-8:
    D 5879-95 Standard Practice for Surface Site Characterization for On-site Septic Systems
    D 5921-96 Standard Practice for Sub-surface Site Characterization of Test Pits for On-site Septic Systems
    D 5925-96 Standard Practice for Preliminary Sizing and Delineation of Soil Absorption Field Areas for On-site Septic Systems.
    Inquiries to Staff Mgr Comm. D18 Soil and Rock, ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, voice: 610-832-9500, fax: 610-832-9555, email: service@astm.org
  • The National Society of Consulting Soil Scientists soil science pointers. Emphasis on locating standards of practice, criteria (like Hydric Soils) and handbooks
  • 75-A.0 New York State Regulation of Private Septic Systems
    75-A.1 Introduction to Septic Systems, Definitions of Septic System Terms
    75-A.2 Regulation of Sewage Treatment Systems by other agencies
    75-A.3 Sewage flows and design flow estimates
    75-A.4 Soil and site appraisal for Septic Systems
    75-A.5 House or building sewer line specifications
    75-A.6 Septic tank capacity requirements, installation, and placement
    75-A.7 Distribution lines, distribution boxes, gravity flow, pressure distribution, dosing, siphons
    75-A.8 Subsurface treatment of effluent, absorption field requirements, leach field design criteria
    75-A.9 Alternative Septic System Designs
    75-A.10 Other systems
    75-A.11 New product/system design interim approval
  • BUY SEPTIC BOOKS ONLINE
  • BUY GREYWATER BOOKS ONLINE
  • BUY COMPOSTING TOILET BOOKS ONLINE

Questions & Answers regarding this article

.

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Recommend / Share this Article            

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also list books on the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

  Septic Videos

SEPTIC BOOK, FREE ONLINE
SEPTIC BOOKSTORE

SEPTIC CARE INSTRUCTIONS
SEPTIC CLEARANCE DISTANCES
SEPTIC CODES & REFERENCES
  DESIGN MANUALS
  SEPTIC STANDARDS
  SEPTIC MAGAZINES
  SEPTIC BOOKS
  BUY SEPTIC BOOKS ONLINE
  BUY GREYWATER BOOKS ONLINE
  BUY COMPOSTING TOILET BOOKS ONLINE
SEPTIC CONSULTANTS

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • To buy books and references discussed at this website, see the Amazon.com supported InspectAPedia Bookstore
  • SEPTIC BOOKS - Septic System Design, Repair, Service Guide Books

    In addition to the septic system design, installation, repair, and alterative design books listed here, you can save time and money ordering these books on septic systems - click on the book-title link - or for detailed septic book reviews and recommendations check out the more detailed book descriptions at the Amazon.com supported InspectAPedia Bookstore

    • Septic System Inspections, Diagnosis, Repair, & Maintenance: our online book, offered at no charge (comments, critique, feedback welcome) including Septic Testing, Loading & Dye Tests, Septic Tank Pumping, Clearances, Septic System details of inspection and testing procedures.

      Septic System Maintenance, Repair, Design Books
    • Septic System Owner's Manual, Lloyd Kahn, Blair Allen, Julie Jones, Shelter Publications, 2000 $14.95 U.S. - easy to understand, well illustrated, one of the best practical references around on septic design basics including some advanced systems; a little short on safety and maintenance.
    • Onsite Wastewater Treatment Systems, Bennette D. Burks, Mary Margaret Minnis, Hogarth House 1994 - one of the best septic system books around for serious professionals
    • Advanced Onsite Wastewater Systems Technologies, Anish R. Jantrania, Mark A. Gross.
    • Water Wells and Septic Systems Handbook, R. Dodge Woodson. This book is in the upper price range, but is worth the cost for serious septic installers and designers.
    • Builder's Guide to Wells and Septic Systems, Woodson, R. Dodge: $ 24.95; MCGRAW HILL B; TP;
    • Wells and Septic Systems, Alth, Max and Charlet, Rev. by S. Blackwell Duncan, $ 18.95; Tab Books 1992.
    • Onsite Wastewater Disposal, R. J. Perkins;
    • Design manual: Onsite wastewater treatment and disposal systems, Richard J Otis, published by the US EPA.
    • Country Plumbing: Living with a Septic System, Hartigan, Gerry: $ 9.95; ALAN C HOOD & TP;
    • Grass is Always Greener Over the Septic Tank, Bombeck, Erma: $ 5.99; FAWCETT; MM;

    • Builder's Guide to Wells and Septic Systems, Woodson, R. Dodge: $ 24.95; MCGRAW HILL B; TP; 01.97
    • Country Plumbing: Living with a Septic System, Hartigan, Gerry: $ 9.95; ALAN C HOOD & TP; 01.86
    • Grass is Always Greener Over the Septic Tank, Bombeck, Erma: $ 5.99; FAWCETT; MM; 01.77
    • Onsite Wastewater Treatment Systems, Bennette D. Burks, Mary Margaret Minnis, Hogarth House 1994 - one of the best books around, small font, weak index
    • Rural Water Supply, New York State Department of Health, 1966, Revised 1995, includes septic distances and some basics. Thin reference.
    • Septic System Owner's Manual, Lloyd Kahn, Blair Allen, Julie Jones, Shelter Publications, 2000 $14.95 U.S. - easy to understand, well illustrated, one of the best practical references around on septic design basics including some advanced systems; a little short on safety and maintenance. you can also buy this book here
    • Wells and Septic Systems, Alth, Max and Charlet, Rev. by S. Blackwell Duncan, $ 18.95; Tab Books 1992

    • Book Listing Submissions Invited Contact Information for D Friedman send us a suggested document link or request an exchange of website links. We also write and publish book reviews for texts within our field of expertise.

    • BUY SEPTIC BOOKS ONLINE
    • BUY GREYWATER BOOKS ONLINE
    • BUY COMPOSTING TOILET BOOKS ONLINE

  • Greywater Systems and Rainwater or Water Conservation Systems
    Greywater and Rainwater System Design Manuals and Books - methods for water recycling, water conservation, rainwater collection, and septic field load reduction.

    In addition to the septic system design, installation, repair, and alterative design books listed here, you can save time and money ordering these books on septic systems - click on the book-title link - or for detailed septic book reviews and recommendations check out the more detailed book descriptions at the Amazon.com supported InspectAPedia Bookstore

    • The New Create an Oasis With Greywater, Art Ludwig; Buy New: $14.25. Ludwig is one of the most thoughtful, prolific, and sometimes controversial writers on gray water systems
    • Builder's Greywater Guide, Art Ludwig; Buy New: $10.17. Installation of Greywater Systems in New Construction & Remodeling; A Supplement to the Book "Create an Oasis With Greywater"
    • Branched Drain Greywater Systems, [superseded by "The New Create an Oasis with Greywater"], Art Ludwig.
    • Create an Oasis With Greywater: Your Complete Guide to Choosing, Building and Using Greywater Systems , Art Ludwig, [superseded by new edition] (Paperback) You may prefer the newer edition available and listed above.
    • Rainwater Catchment Systems for Domestic Supply: Design, Construction and Implementation, Erik Nissen-Petersen, John Gould.
    • Guidelines on rainwater catchment systems for Hawaii , (CTAHR resource management publication) Patricia S. H Macomber. This more technical document may be especially helpful for rainwater collection
    • Design for Water: Rainwater Harvesting, Stormwater Catchment, and Alternate Water Reuse, Heather Kinkade-Levario.
    • The Toilet Papers: Designs to Recycle Human Waste and Water : Dry Toilets, Greywater Systems and Urban Sewage Sim Van Der Ryn, Wendell Berry;
    • Rainwater Reservoirs Above Ground Structures for Roof Catchment : Most Common Rainwater Tanks in Comparison and Construction Manual, Rolf Hasse.
    • Quality issues in harvested rainwater in arid and semi-arid Loess Plateau of northern China, K. Zhu, L. Zhang, W. Hart, M. Liu, H. Chen (out of print, find by search and deferred order)
    • City eying home water-recycling technology; uses bath and washer water for irrigation., (ReWater Systems' equipment for greywater irrigation):
    • BUY SEPTIC BOOKS ONLINE
    • BUY GREYWATER BOOKS ONLINE
    • http://astore.amazon.com/inspectapedia-20?_encoding=UTF8&node=8
    • BUY COMPOSTING TOILET BOOKS ONLINE
      http://astore.amazon.com/inspectapedia-20?_encoding=UTF8&node=9
  • Composting Toilets and Low Water or No-Water Toilets

    Design Manuals and Books - for water conservation, composting toilets, waterless toilet systems, and septic field load reduction.

    In addition to the septic system design, installation, repair, and alterative design books listed here, you can save time and money ordering these books on septic systems - click on the book-title link - or for detailed septic book reviews and recommendations check out the more detailed book descriptions at the Amazon.com supported InspectAPedia Bookstore

    • Composting Toilet System Book: A Practical Guide to Choosing, Planning and Maintaining Composting Toilet Systems , David Del Porto, Carol Steinfeld
    • The Humanure Handbook: A Guide to Composting Human Manure, 3rd Ed., Joseph C. Jenkins
    • Thermal composting of faecal matter as treatment and possible disinfection method--laboratory-scale and pilot-scale studies, B. Vinneras, A. Bjorklund, H. Jonsson
    • Experiences with a composting toilet article from: Countryside & Small Stock Journal, available as HTML download

    • BUY SEPTIC BOOKS ONLINE
    • BUY GREYWATER BOOKS ONLINE
    • BUY COMPOSTING TOILET BOOKS ONLINE

  • SEPTIC MAGAZINES - Septic System and Onsite Wastewater Magazines or Electronic Publications
    • A Home Buyer's Guide to Septic Systems
    • Pumper Magazine magazine for septic servicing industry, equipment sources, classified ads, business articles
    • Septic System Inspections, Diagnosis, Repair, & Maintenance: our online book, Septic Testing, Loading & Dye Tests, Septic Tank Pumping, Clearances, Septic System details of inspection and testing procedures.
    • Swopnet Engineering Databank articles and information about septic systems.
    • Pipeline wastewater topics for community officials and Small Flows technical information for engineers and regulators, are free newsletters available from National Small Flows Clearinghouse, 800-624-8301, 304-293-3161-FAX or Email to order NSFC publications
    • Small Flows Journal ideas and methodologies for solving wastewater issues for small communities
  • ...

SEPTIC BOOKS - Septic System Design, Repair, Service Guide Books

In addition to the septic system design, installation, repair, and alterative design books listed here, you can save time and money ordering these books on septic systems - click on the book-title link - or for detailed septic book reviews and recommendations check out the more detailed book descriptions at the Amazon.com supported InspectAPedia Bookstore

  • Septic System Inspections, Diagnosis, Repair, & Maintenance: our online book, offered at no charge (comments, critique, feedback welcome) including Septic Testing, Loading & Dye Tests, Septic Tank Pumping, Clearances, Septic System details of inspection and testing procedures.

    Septic System Maintenance, Repair, Design Books
  • Septic System Owner's Manual, Lloyd Kahn, Blair Allen, Julie Jones, Shelter Publications, 2000 $14.95 U.S. - easy to understand, well illustrated, one of the best practical references around on septic design basics including some advanced systems; a little short on safety and maintenance.
  • Onsite Wastewater Treatment Systems, Bennette D. Burks, Mary Margaret Minnis, Hogarth House 1994 - one of the best septic system books around for serious professionals
  • Advanced Onsite Wastewater Systems Technologies, Anish R. Jantrania, Mark A. Gross.
  • Water Wells and Septic Systems Handbook, R. Dodge Woodson. This book is in the upper price range, but is worth the cost for serious septic installers and designers.
  • Builder's Guide to Wells and Septic Systems, Woodson, R. Dodge: $ 24.95; MCGRAW HILL B; TP;
  • Wells and Septic Systems, Alth, Max and Charlet, Rev. by S. Blackwell Duncan, $ 18.95; Tab Books 1992.
  • Onsite Wastewater Disposal, R. J. Perkins;
  • Design manual: Onsite wastewater treatment and disposal systems, Richard J Otis, published by the US EPA.
  • Country Plumbing: Living with a Septic System, Hartigan, Gerry: $ 9.95; ALAN C HOOD & TP;
  • Grass is Always Greener Over the Septic Tank, Bombeck, Erma: $ 5.99; FAWCETT; MM;

  • Builder's Guide to Wells and Septic Systems, Woodson, R. Dodge: $ 24.95; MCGRAW HILL B; TP; 01.97
  • Country Plumbing: Living with a Septic System, Hartigan, Gerry: $ 9.95; ALAN C HOOD & TP; 01.86
  • Grass is Always Greener Over the Septic Tank, Bombeck, Erma: $ 5.99; FAWCETT; MM; 01.77
  • Onsite Wastewater Treatment Systems, Bennette D. Burks, Mary Margaret Minnis, Hogarth House 1994 - one of the best books around, small font, weak index
  • Rural Water Supply, New York State Department of Health, 1966, Revised 1995, includes septic distances and some basics. Thin reference.
  • Septic System Owner's Manual, Lloyd Kahn, Blair Allen, Julie Jones, Shelter Publications, 2000 $14.95 U.S. - easy to understand, well illustrated, one of the best practical references around on septic design basics including some advanced systems; a little short on safety and maintenance. you can also buy this book here
  • Wells and Septic Systems, Alth, Max and Charlet, Rev. by S. Blackwell Duncan, $ 18.95; Tab Books 1992

  • Book Listing Submissions Invited Contact Information for D Friedman send us a suggested document link or request an exchange of website links. We also write and publish book reviews for texts within our field of expertise.

  • BUY SEPTIC BOOKS ONLINE
  • BUY GREYWATER BOOKS ONLINE
  • BUY COMPOSTING TOILET BOOKS ONLINE

Greywater Systems and Rainwater or Water Conservation Systems

Greywater and Rainwater System Design Manuals and Books - methods for water recycling, water conservation, rainwater collection, and septic field load reduction.

In addition to the septic system design, installation, repair, and alterative design books listed here, you can save time and money ordering these books on septic systems - click on the book-title link - or for detailed septic book reviews and recommendations check out the more detailed book descriptions at the Amazon.com supported InspectAPedia Bookstore

  • The New Create an Oasis With Greywater, Art Ludwig; Buy New: $14.25. Ludwig is one of the most thoughtful, prolific, and sometimes controversial writers on gray water systems
  • Builder's Greywater Guide, Art Ludwig; Buy New: $10.17. Installation of Greywater Systems in New Construction & Remodeling; A Supplement to the Book "Create an Oasis With Greywater"
  • Branched Drain Greywater Systems, [superseded by "The New Create an Oasis with Greywater"], Art Ludwig.
  • Create an Oasis With Greywater: Your Complete Guide to Choosing, Building and Using Greywater Systems , Art Ludwig, [superseded by new edition] (Paperback) You may prefer the newer edition available and listed above.
  • Rainwater Catchment Systems for Domestic Supply: Design, Construction and Implementation, Erik Nissen-Petersen, John Gould.
  • Guidelines on rainwater catchment systems for Hawaii , (CTAHR resource management publication) Patricia S. H Macomber. This more technical document may be especially helpful for rainwater collection
  • Design for Water: Rainwater Harvesting, Stormwater Catchment, and Alternate Water Reuse, Heather Kinkade-Levario.
  • The Toilet Papers: Designs to Recycle Human Waste and Water : Dry Toilets, Greywater Systems and Urban Sewage Sim Van Der Ryn, Wendell Berry;
  • Rainwater Reservoirs Above Ground Structures for Roof Catchment : Most Common Rainwater Tanks in Comparison and Construction Manual, Rolf Hasse.
  • Quality issues in harvested rainwater in arid and semi-arid Loess Plateau of northern China, K. Zhu, L. Zhang, W. Hart, M. Liu, H. Chen (out of print, find by search and deferred order)
  • City eying home water-recycling technology; uses bath and washer water for irrigation., (ReWater Systems' equipment for greywater irrigation):
  • BUY SEPTIC BOOKS ONLINE
  • BUY GREYWATER BOOKS ONLINE
  • BUY COMPOSTING TOILET BOOKS ONLINE

Composting Toilets and Low Water or No-Water Toilets

Design Manuals and Books - for water conservation, composting toilets, waterless toilet systems, and septic field load reduction.

In addition to the septic system design, installation, repair, and alterative design books listed here, you can save time and money ordering these books on septic systems - click on the book-title link - or for detailed septic book reviews and recommendations check out the more detailed book descriptions at the Amazon.com supported InspectAPedia Bookstore

  • Composting Toilet System Book: A Practical Guide to Choosing, Planning and Maintaining Composting Toilet Systems , David Del Porto, Carol Steinfeld
  • The Humanure Handbook: A Guide to Composting Human Manure, 3rd Ed., Joseph C. Jenkins
  • Thermal composting of faecal matter as treatment and possible disinfection method--laboratory-scale and pilot-scale studies, B. Vinneras, A. Bjorklund, H. Jonsson
  • Experiences with a composting toilet article from: Countryside & Small Stock Journal, available as HTML download

  • BUY SEPTIC BOOKS ONLINE
  • BUY GREYWATER BOOKS ONLINE
  • BUY COMPOSTING TOILET BOOKS ONLINE

SEPTIC MAGAZINES - Septic System and Onsite Wastewater Magazines or Electronic Publications

  • A Home Buyer's Guide to Septic Systems
  • Pumper Magazine magazine for septic servicing industry, equipment sources, classified ads, business articles
  • Septic System Inspections, Diagnosis, Repair, & Maintenance: our online book, Septic Testing, Loading & Dye Tests, Septic Tank Pumping, Clearances, Septic System details of inspection and testing procedures.
  • Swopnet Engineering Databank articles and information about septic systems.
  • Pipeline wastewater topics for community officials and Small Flows technical information for engineers and regulators, are free newsletters available from National Small Flows Clearinghouse, 800-624-8301, 304-293-3161-FAX or Email to order NSFC publications
  • Small Flows Journal ideas and methodologies for solving wastewater issues for small communities

  • Submissions welcome. send us a suggested document link or request an exchange of website links
  • The Septic System Information Website home page for this topic
  • Septic Systems Inspection, Testing, & Maintenance- online textbook. Detailed how to inspect, maintain, repair information
  • The Home Buyer's Guide to Septic Systems
  • Septic Tank Pumping Guide: When, Why, How to pump the septic tank
  • Home & Outdoor Living Water Requirements
  • Septic Tank Capacity vs Usage in Daily Gallons of Wastewater Flow, calculating required septic tank size, calculating septic tank volume from size measurements
  • Septic Tank/Soil-Absorption Systems: How to Operate & Maintain [ copy on file as /septic/Septic_Operation_USDA.pdf ] - , Equipment Tips, U.S. Department of Agriculture, 8271 1302, 7100 Engineering, 2300 Recreation, September 1982, web search 08/28/2010, original source: http://www.fs.fed.us/t-d/pubs/pdfimage/82711302.pdf.
  • How Big Should the Leach Field Be? - table of soil percolation rate vs. field size
  • Septic System Drainfield Absorption System Biomat Formation - what leads to drain field clogging and expensive drainfield repairs
  • Table of Required Septic & Well Clearances: Distances Between Septic System & Wells, Streams, Trees, etc.
  • Ten Steps to Keeping a Septic System Working, suggestions from the U.S. EPA, edits and additions by DJF
  • Pennsylvania State Fact Sheets relating to domestic wastewater treatment systems include
    • Pennsylvania State Wastewater Treatment Fact Sheet SW-161, Septic System Failure: Diagnosis and Treatment
    • Pennsylvania State Wastewater Treatment Fact Sheet SW-162, The Soil Media and the Percolation Test
    • Pennsylvania State Wastewater Treatment Fact Sheet SW-l64, Mound Systems for Wastewater Treatment
    • Pennsylvania State Wastewater Treatment Fact Sheet SW-165, Septic Tank-Soil Absorption Systems
    • Document Sources used for this web page include but are not limited to: Agricultural Fact Sheet #SW-161 "Septic Tank Pumping," by Paul D. Robillard and Kelli S. Martin. Penn State College of Agriculture - Cooperative Extension, edited and annotated by Dan Friedman (Thanks: to Bob Mackey for proofreading the original source material.)
  • ...

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Inspecting Septic Systems: Online Book, Inspection, Test, Diagnosis, Repair, & Maintenance: our Online Septic Book: Septic Testing, Loading & Dye Tests, Septic Tank Pumping, Clearances, details of onsite waste disposal system inspection, testing, repair procedures.

  • Advanced Onsite Wastewater Systems Technologies, Anish R. Jantrania, Mark A. Gross. Anish Jantrania, Ph.D., P.E., M.B.A., is a Consulting Engineer, in Mechanicsville VA, 804-550-0389 (2006). Outstanding technical reference especially on alternative septic system design alternatives. Written for designers and engineers, this book is not at all easy going for homeowners but is a text I recommend for professionals--DF.
  • Builder's Guide to Wells and Septic Systems, Woodson, R. Dodge: $ 24.95; MCGRAW HILL B; TP; Quoting from Amazon's description: For the homebuilder, one mistake in estimating or installing wells and septic systems can cost thousands of dollars. This comprehensive guide filled with case studies can prevent that. Master plumber R. Dodge Woodson packs this reader-friendly guide with guidance and information, including details on new techniques and materials that can economize and expedite jobs and advice on how to avoid mistakes in both estimating and construction. Chapters cover virtually every aspect of wells and septic systems, including on-site evaluations; site limitations; bidding; soil studies, septic designs, and code-related issues; drilled and dug wells, gravel and pipe, chamber-type, and gravity septic systems; pump stations; common problems with well installation; and remedies for poor septic situations. Woodson also discusses ways to increase profits by avoiding cost overruns.
  • Country Plumbing: Living with a Septic System, Hartigan, Gerry: $ 9.95; ALAN C HOOD & TP; Quoting an Amazon reviewer's comment, with which we agree--DF:This book is informative as far as it goes and might be most useful for someone with an older system. But it was written in the early 1980s. A lot has changed since then. In particular, the book doesn't cover any of the newer systems that are used more and more nowadays in some parts of the country -- sand mounds, aeration systems, lagoons, etc.

Design Manuals for Septic Systems

  • US EPA Onsite Wastewater Treatment Systems Manual [online copy, free] Top Reference: US EPA's Design Manual for Onsite Wastewater Treatment and Disposal, 1980, available from the US EPA, the US GPO Superintendent of Documents (Pueblo CO), and from the National Small Flows Clearinghouse. Original source http://www.epa.gov/ORD/NRMRL/Pubs/625R00008/625R00008.htm Onsite wastewater treatment and disposal systems, Richard J Otis, published by the US EPA. Although it's more than 20 years old, this book remains a useful reference for septic system designers. U.S. Environmental Protection Agency, Office of Water Program Operations; Office of Research and Development, Municipal Environmental Research Laboratory; (1980)
  • Eco John® Innovative Toilet Solutions, Global Inventive Industries, Fountain Valley CA, PDF, product brochure
  • "International Private Sewage Disposal Code," 1995, BOCA-708-799-2300, ICBO-310-699-0541, SBCCI 205-591-1853, available from those code associations.
  • "Manual of Policy, Procedures, and Guidelines for Onsite Sewage Systems," Ontario Reg. 374/81, Part VII of the Environmental Protection Act (Canada), ISBN 0-7743-7303-2, Ministry of the Environment,135 St. Clair Ave. West, Toronto Ontario M4V 1P5 Canada $24. CDN.
  • Manual of Septic Tank Practice, US Public Health Service's 1959.

Onsite Wastewater Disposal Books

  • Onsite Wastewater Disposal, R. J. Perkins; Quoting from Amazon: This practical book, co-published with the National Environmental Health Association, describes the step-by-step procedures needed to avoid common pitfalls in septic system technology. Valuable in matching the septic system to the site-specific conditions, this useful book will help you install a reliable system in both suitable and difficult environments. Septic tank installers, planners, state and local regulators, civil and sanitary engineers, consulting engineers, architects, homeowners, academics, and land developers will find this publication valuable.
  • Onsite Wastewater Treatment Systems, Bennette D. Burks, Mary Margaret Minnis, Hogarth House 1994 - one of the best septic system books around, suffering a bit from small fonts and a weak index. While it contains some material more technical than needed by homeowners, Burks/Minnis book on onsite wastewater treatment systems a very useful reference for both property owners and septic system designers.
  • Septic Tank/Soil-Absorption Systems: How to Operate & Maintain [ copy on file as /septic/Septic_Operation_USDA.pdf ] - , Equipment Tips, U.S. Department of Agriculture, 8271 1302, 7100 Engineering, 2300 Recreation, September 1982, web search 08/28/2010, original source: http://www.fs.fed.us/t-d/pubs/pdfimage/82711302.pdf
  • Soil Percolation Tests soil perc testing guide and instructions
  • Percolation Testing Manual, CNMI Division of Environmental Quality, PO Box 501304, Saipan, MP 96950
  • Planting Over Septic System Component", Daniel Friedman (author/editor, InspectAPedia.com), The Innovator, Winter/Spring 2008, BCOSSA, British Columbia OnSite Sewage Association, 201-3542 Blansard St., Victoria BC V8X 1W3 Canada
  • Save the Septic System - Do Not Flush These Items Down the Toilet, Daniel Friedman, InspectAPedia.com - PDF document, printable
  • SEPTIC STANDARDS
  • SEPTIC MAGAZINES
  • Septic System Owner's Manual, Lloyd Kahn, Blair Allen, Julie Jones, Shelter Publications, 2000 $14.95 U.S. - easy to understand, well illustrated, one of the best practical references around on septic design basics including some advanced systems; a little short on safety and maintenance. Both new and used (low priced copies are available, and we think the authors are working on an updated edition--DF. Quoting from one of several Amazon reviews: The basics of septic systems, from underground systems and failures to what the owner can do to promote and maintain a healthy system, is revealed in an excellent guide essential for any who reside on a septic system. Rural residents receive a primer on not only the basics; but how to conduct period inspections and what to do when things go wrong. History also figures into the fine coverage.
  • Test Pit Preparation for Onsite Sewage Evaluations, State of Oregon Department of Environmental Quality, Portland OR, 800 452-4011. PDF document. We recommend this excellent document that offers detail about soil perc tests, deep hole tests, safety, and septic design. Readers should also see Soil Percolation Tests and for testing an existing septic system, also see Dye Tests
  • Grass is Always Greener Over the Septic Tank, Bombeck, Erma: $ 5.99; FAWCETT; MM; This septic system classic whose title helps avoid intimidating readers new to septic systems, is available new or used at very low prices. It's more entertainment than a serious "how to" book on septic systems design, maintenance, or repair. Not recommended -- DF.
  • US EPA Onsite Wastewater Treatment Systems Manual Top Reference: US EPA's Design Manual for Onsite Wastewater Treatment and Disposal, 1980, available from the US EPA, the US GPO Superintendent of Documents (Pueblo CO), and from the National Small Flows Clearinghouse. Original source http://www.epa.gov/ORD/NRMRL/Pubs/625R00008/625R00008.htm
  • Water Wells and Septic Systems Handbook, R. Dodge Woodson. This book is in the upper price range, but is worth the cost for serious septic installers and designers. Quoting Amazon: Each year, thousands upon thousands of Americans install water wells and septic systems on their properties. But with a maze of codes governing their use along with a host of design requirements that ensure their functionality where can someone turn for comprehensive, one-stop guidance? Enter the Water Wells and Septic Systems Handbook from McGraw-Hill.
    Written in language any property owner can understand yet detailed enough for professionals and technical students this easy-to-use volume delivers the latest techniques and code requirements for designing, building, rehabilitating, and maintaining private water wells and septic systems. Bolstered by a wealth of informative charts, tables, and illustrations, this book delivers:
    * Current construction, maintenance, and repair methods
    * New International Private Sewage Disposal Code
    * Up-to-date standards from the American Water Works Association
  • Wells and Septic Systems, Alth, Max and Charlet, Rev. by S. Blackwell Duncan, $ 18.95; Tab Books 1992. We have found this text very useful for conventional well and septic systems design and maintenance --DF. Quoting an Amazon description:Here's all the information you need to build a well or septic system yourself - and save a lot of time, money, and frustration. S. Blackwell Duncan has thoroughly revised and updated this second edition of Wells and Septic Systems to conform to current codes and requirements. He also has expanded this national bestseller to include new material on well and septic installation, water storage and distribution, water treatment, ecological considerations, and septic systems for problem building sites.
  • The NSFC Products List has an excellent list of design manuals/modules available from their website or by telephone 800-624-8301
  • Submissions welcome. send us a suggested document link or request an exchange of website links
  • ...

Home About Us Accuracy Contact Us Content Use Policy Printing Tips Privacy Website Description © 2012 Copyright InspectAPedia.com