Slantfin Equipment Age, Contact, Manuals, Parts
Manuals, parts lists, wiring diagrams & contact information for SlantFin heating equipment:
We include immediate downloads of example installation & repair manuals and wiring diagrams for air conditioners, heat pumps, and heating equipment from a variety of manufacturers as well as contact information to obtain the exact manual or wiring diagram for your unit.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
Below we provide SlantFin HVAC manufacturer contact information and direct links to free downloadable installation, service, and users manuals, focusing on hard-to-find manuals for older models or discontinued equipment. We also provide links to the manufacturer's current model lists and literature.
Slantfin Boiler Age Encoding |
|
| Serial Number | Manufacture date / year |
| 07041 | 1971 |
| 110033 | October 1982 |
| 14185 | 1992 |
| 111276 | November 2002 |
| 253376 | November 2004 |
| 600574 | March 2008 |
Source:
Carson Dunlop, Associates, Toronto, have provided us with (and we recommend) Carson Dunlop Weldon & Associates'Technical Reference Guide to manufacturer's model and serial number information for heating and cooling equipment
Special Offer: Carson Dunlop Associates offers InspectAPedia readers in the U.S.A. a 5% discount on any number of copies of the Technical Reference Guide purchased as a single order. Just enter INSPECTATRG in the order payment page "Promo/Redemption" space.
...
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
I'm trying to figure out the age of my Slant Fin boiler S/N #540429 2018/05/08 Rob
Reply:
Rob on a Slant Fin boiler serial numbers encode the age in a sequential pattern that is not obvious. But compare your SlantFin boiler serial number with the examples we give in the table above.
Given that
253376 is a boiler made in November 2004
and600574 is a boiler made in March 2008,
Your boiler was probably manufactured somewhere between those years.
Contact the SlantFin company directly for a more precise age readout
Slantfin also manufactures Galaxy water heaters
Then post a photo of your boiler's data tag for us to research the question further.
60,000 btu electric domestic slant fin using spring water, installed 2008. What is the likely life expectancy? Is it already on borrowed time? On 2019-04-03 by Stanley Avery
Moderator reply:
Apologies if this sounds like I'm ducking, Stanley, but having worked for quite a few years installing and servicing heating boilers my opinion is ... it depends.
Moreso when we don't know the model and condition of your specific heating boiler.
I've seen 80 year boilers going strong and in some cases even boilers closer to 100 years old in commercial use as I illustrate in
this article: STEAM BOILERS GENERATORS CONTROLS, PRATT
So if your boiler has been properly maintained and isn't rust damaged, you could keep using it.
Ask your heating service technician to tell you of any visible damage and also to give you the boiler's efficiency rating after it has been cleaned and tuned.
These 4 TIPS to EXTEND THE LIFE OF A BOILER [PDF] from Oatey may also help you out.
...
Continue reading at MANUALS for HEATING & A/C SYSTEM CONTROLS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
SLANTFIN AGE, MANUALS, CONTACT INFO at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Or see
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
If you posted comments here and no longer see what you wrote, please check for your comment in the Reader Q&A found above on this page.
In addition to any citations in the article above, a full list is available on request.