Stair slip trip & fall hazards guide:
Stair tread & step construction or maintenance mistakes can create a wide range of serious stair fall hazards.
Using illustrations from around the world, we illustrate many common causes of stair falls and injuries such as uneven or damaged steps and stairs, missing or unsafe railings, loose, crooked treads, or lack of visual cues that tell a walker that she is approaching a step.
In this article we include the classic mistake: a loose throw rug at the top of a stairway. Page top photo: severely damaged stair treads, rotted stair stringers and treads, rotted loose newel post and an open sided stairway to the basement of this home lake these stairs treacherous.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
Photographs of all kinds of stair and step & walk defects illustrate a wide range of causes of falling down the stairs - stair trip and fall hazards and injury sources.
Here we discuss and illustrate worn, loose, damaged steps & stair fall hazards. narrow tall stair steps, slippery stair tread surfaces. curved, angled, & winder stair trip hazards. discontinuous, awkward, stairs & steps.
Curved, tapered steps & stair hazards. Lack of visual clues to indicate presence of a step or stair. Is it a step or a passage?
A loose rug at the top of the stairs is a fall hazard.
SLIP TRIP & FALL HAZARD LIST, STAIRS, FLOORS, WALKS
Photo: this photo of lovers standing on stairs at Palenque in Chiapas, Mexico demonstrates that there are various possible distractions along a stairway and that people using the stairs are often not paying attention to the steps, their walking surface, handrailing security, nor step consistency in surface, height, slope, width.
Angled or Curved stair treads are a particular trip hazard, especially because of the lack of uniformity and because the tread width at the inside of the curve can be too small for safe walking.
Our photo above illustrates a stair fall hazard more common than the severely worn steps at page top. The safety tread on these stairs in a New York City gallery have broken away at the tread nose.
Even more serious a fall hazard are sections of stair tread nosing that are still in place but that have become split, cracked, loose or fragile.
This stair nose falling hazard is discussed
at STAIR TREAD NOSE BROKEN-FALLS
Above: a loose rug at the top of stairs is a very dangerous fall hazard.
Wyatt (1999) points out that carpeting on stairs may actually reduce the severity of injury to people who fall down stairs. Nevertheless carpeting on steps and stairs is a also potential source of slip and fall hazards that have been extensively researched (Rosen 2013).
Some carpeted stair hazards that we most-frequently observe are listed below.
Below: carpeting and walking surfaces all of the identical material lack a color change and invite fall hazards, especially among the elderly or vision-impaired users.
Below: Loose carpet held on steps in this Oxford U.K. hotel tends to creep and form loose folds or wrinkles at the step outer nose - a fall hazard.
Photo: a combination of carpeted landing (orange arrow) and a raised wood lip forming a nice trip hazard (red arrow) at the top of a stairway in a retail shop upstairs floor in Genoa, Italy.
I speculate that someone decided to repair the stairway by adding a cap-tread on each step, but on reaching the upper floor it was observed that the shorter rise created by the capped step below formed a trip hazard.
So the builder moved the trip hazard around the corner, beveled the stair top platform, and carpeted it.
Other trip hazards on this floor include loose and gapped parquet flooring (light green circle) and loose throw-rugs on a slippery wooden floor (blue arrow).
Research has found that women, more-often than others, have only one-hand free when negotiating stairs - placing them at an increased risk of stair fall injuries.
Above: tourists ascending a steep stairway, the mom is carrying the baby, having no hands free.
Below, descending stairs and carrying shopping bags.
Well this collapsing stair in northern Maine in the U.S. is pretty obvious. But there are more subtle stair collapse hazards including stair carriages not properly secured to the structure, stair tread cleats not properly secured to the stair carriage or stringer, and under-sized, over-cut stair stringers as you'll see in other photos in this series.
Stair treads not properly secured to the stair carriage or stair stringer are a particularly odious collapse hazard.
The stairs shown above are discussed in more detail
at SLIPS, TRIPS & FALLS, EXTERIOR STAIRS
As we illustrate below, even solid masonry stairs may, left exposed to weather, slip, tilt, or collapse.
Above: to complete one of the worst stairways we've encountered in Mexico, check out the combination of a rounded step with one that tapers to a point, giving the walker almost nowhere to step comfortably nor safely.
Do not expect an elderly or disabled person to consider using stairs by Machete Ken, the builder of these interesting climbers.
Below: these curved steps in Tucson, Arizona, are awkward enough that this stair user was hesitating before taking the plunge.
Our photos below show two different sorts of difficult-to-use stairs. At below left the steps are familiar to locals and visitors to San Miguel de Allende, the side steps to the Parroquia. Construction on the Parroquia, began in the 1600s, and its current facade was completed by a master mason whose sketches, drawn in the dirt in the 1860's resulted in a unique and widely loved neo-gothic facade.
The steps shown appear to date from that epoch. At below right we begin illustrating scarier stairs in the same city.
At above right the stair, located in a private home in San Miguel de Allende, is used to access a tiny rooftop patio.
The climbs a narrow metal stair, then from a tiny platform, leap onto a step where you can see my left foot, then ascend to the patio. The builder included an overhead "grab rail" (below left) to give users a small chance at surviving access to the up
A curtain hung from the grab rail interferes with grasping it, and finally, even getting on or off of the metal stairway includes another discontinuous "partial" step near the stair bottom, as our friend Rebecca demonstrated during our visit in 2005.
Walking down a set of stairs entered by having to open a door that swings out over the steps is likely to result in a fall.
That's in part because holding onto the door knob to open the door tends to direct where the walker is going to step - out into space (expecting a landing) rather than with great care down onto the first stair tread.
More about problems with a door that swings out over steps is at STAIR PLATFORMS & LANDINGS FAQs .
Definition & history of false-step stairs: The trip and fall hazard caused by stairs whose steps are uneven in height (rise) has been known probably for thousands of years as one discovers it promptly when using uneven-rise stairs without paying close attention to the step height.
More than 3/8 of an inch in variation of the height of steps from one step to another is a tripping hazard.
Our photo illustrates uneven-rise as well as out of level stair treads at a New Zealand hotel property. Owners warn stair users about the dodgy steps.
While most false-step stair hazards are constructed in error, in some structures stair builders deliberately created a so-called false-step. False step stairs feature in both reality and historical fiction.
So what’s different about this particular stair, located at the 36th Street station in Sunset Park? And why is everyone tripping? It turns out that one of the steps is half an inch higher than the others — which is just high enough to send even the most coordinated climbers reeling.
Filmmaker Dean Peterson, who frequents the station daily, noticed this engineering glitch and decided to document it, filming instance after instance of climbers stumbling — some steadying themselves and others falling straight down. ...
After this video of a problematic Brooklyn [New York] subway staircase went viral, the MTA stepped in to fix the problem. (Grossman 2012).
In the process of renovation, he devoted considerable attention to one small design detail of the stairway -- the so-called false step. The riser of the false step was one inch higher than the other steps so that it would trip up anybody unfamiliar with it and serve as a primitive burglar alarm.
This was a device used in many old houses [in Savannah, Georgia in the U.S.], but it proved to be a hazard for Driggers, since he generally arrived home in no shape to deal with normal stairs, let alone trick ones. (Berendt 1994).
Below: a dramatic false-step stair in Tucson.
The first step is much shorter in rise than the remaining ones, none of the step risers are uniform in height, four of the five risers are too tall, and heaven knows how users step securely onto that topmost tread in front of the door itself.
See STAIR RISER SPECIFICATIONS for details about proper step riser height and riser uniformity requirements.
At left we indicate a stair railing mistake that you may encounter in a home where a narrow stairwell has made it difficult to move furniture in or out of a room.
Someone removes the railing to move large items up or down the stairs - and doesn't bother to replace it.
There are so many ways to foul up a handrail on steps and stairs that we have collected railing specifications and examples of mistakes in a separate article -
see HANDRAILS & HANDRAILINGS .
More deceptive than a handrailing that is totally missing is a handrail that is not graspable: a non-graspable handrail denies the stair user the chance to prevent or arrest a fall.
The handrailing shown below is also the top of the stair guard: it's much too wide to grasp securely.
Handrailings that are not-graspable, too low, too high, or that are not securely fastened are in some respects more dangerous than no handrailing at all, since the stair user thinks there she can grasp the handrail to prevent a fall.
In fact, if a handrailing comes away from its mounting, breaks, is too big to grasp securely, or is simply too loose, the stair user is more likely to be badly hurt during a fall, and worse, if the railing comes away and tangles with the stair user, injuries may become compounded. [We investigated just such a case - the person who fell was badly hurt as he and the railing fell together into a stairwell - Ed.]
Details are at GRASPABILITY of HANDRAILINGS
In the photograph above, also griped-about
at GUARDRAILS DEFECTIVE or MISSING
the handrail and stair guard (presumably balusters) were both removed.
Below we show a safe guardrailing along a stairway at the Castle Point Veterans Administration Facility in Dutchess County, New York.
While Handrailings are placed along stairs to provide a gripping surface to help stair users prevent or arrest a fall down the stairs, stair guards or guardrailings have a different purpose and may be higher than handrailings:
the purpose of stair guards or stair guardrailings is to prevent someone from falling off or through the open side(s) of a stairway.
As you see in our photo below, where the top of the stair guard would be too high to serve also as a handrailing, a railing must be provided and securely attached.
Above my hand is grasping the handrailing along the same stairway. As you see, the handrailing is at a lower height above the walking surface of the treads than is the top of the stair guardrail.
The next photograph illustrates the opposite condition. At New Zealand's University of Canterbury the stair builders added a handrailing along the top of the stair guard.
The following is excerpted
from STAIR RAILS, STAIR GUARDS
1926.1052(c)(5) Handrails and the top rails of stair rails shall be capable of withstanding, without failure, a force of at least 200 pounds (890 n) applied within 2 inches (5 cm) of the top edge, in any downward or outward direction, at any point along the top edge.
1926.1052(c)(6) The height of handrails shall be not less than 34 inches nor more than 38 inches from the upper surface of the handrail to the surface of the tread, in line with the face of the riser at the forward edge of the tread.
Now found at LIGHTING OVER STAIRS & AT EXITS
Loose bricks in theses steps are a sneaky trip hazard: step onto the outer end of the brick and it flips up as you flip down the steps. The Poughkeepsie homeowner has since re-built these brick stairs.
A loose or inadequately-connected newel post at the top or bottom of a stairway or access ramp is a serious fall hazard as it risks failure to adequately support the handrail or stair or ramp guard sufficiently to arrest a fall.
Clearly nothing is safe about this basement stairway.
Shown below the stair treads are too narrow - a single 2x6 was used, making these treads only 5 1/2" deep.
The stair stringers were placed "upside down" in order to achieve the total height or rise that this stair-dope was constructing, but he failed to appreciate just how puny is the remaining structural part of the stair carriage.
These stairs may collapse if we don't fall down them first.
There are other troubles with these stairs too, discussed
Above: a tread depth that is inadequate. Tread depth is the distance from the stair tread nose to the face of the stair step riser.
The toe of my ugly shoe is against the step riser and you can see that the heel of my shoe doesn't fit onto the step. The only way to climb these attic stairs is on tip-toe or by placing your foot sideways along each stair tread.
Details are at STAIR TREAD DIMENSIONS
Obstructions or stuff left stored along stairs are a serious trip and fall hazard, more likely to cause an accident at the worst time: during an emergency evacuation of a building when people are trying to run up or down the stairway.
Also see ATTIC STAIR CODES & HAZARDS
Shown below: a "stair guard" that is too open: a child could easily fall through the opening along these stairs and ramps. In this case the child would fall into hot boiling mud at this New Zealand facility on South Island.
See GUARDRAILS on STAIRS for details.
Is it against building code that electrical boxes mounted inches above top step at roof hatch on commercial building before entering roof? - Jimmy Johnson, 8 June 2012
Jimmy: the question is unclear, but if the electrical boxes are an obstruction, trip hazard, or are going to be used as a walking surface, any of those would be an objectionable hazard.
I'd need to see some photos to have a more accurate opinion, but in general, if the boxes are a trip hazard in the walking path or if they are going to be stepped on I'm sure it'd be a bad practice.
This question was originally posted at BUILDING CODES for STAIRS
Here are some photos, trying to find out these boxes are mounted is a building code. Thanks - Jimmy
Standard stairway safety requirements are for stairs intended for normal occupancy-use while access to lofts, roofs, and mechanicals areas are usually held to a different standard as they are not in normal, daily, public use. OSHA standards and rules may apply, however.
Nonetheless the trip and fall hazards in your stairway photos are in my opinion obvious and are unsafe.
Photo 1 - above, shows a steep roof access stair with a handrailing that ends well below the final step out over a hatch and onto the roof surface.
We can also see two electrical boxes protruding into the walking path at the top riser, and a very large opening between the topmost tread and the vertical riser formed by the roof access hatch wall.
Mr. Johnson's second photo (immediately at left) shows the opening between the last stair tread and the open riser space, as well as two electrical boxes installed on the face of the roof framing above the last step.
This photo (left) also suggests that there is a considerable variation in riser height from the top tread to step over the access hatch and onto the roof.
The third stair-injury photo (below left) gives additional view of the height of the roof access hatch. It appears again that this is a high step from the last or uppermost stair tread.
We can also see that there is no grab rail, nor handle for use by someone climbing up out of or down into the stairwell. Naturally the requirement for a closable roof access hatch cover precludes a permanent railing extending the standard height above the stair walking surface.
These steps were most likely designed only for use by building maintenance personnel.
As such, while there are OSHA rules governing workplace stairways, the requirements governing stairway pitch and tread design and handrails are different from those expressed in building codes pertaining to stairs intended for general or public use.
Jimmy in my OPINION, regardless of a possible third party interpretation of OSHA regulations or building codes, the stairway in your photos is unsafe for several reasons including
Also in my OPINION, even if a local code official OK's the stair, if, heaven forbid, someone should be injured, you should not count on the code department to come to your defense, and an expert may agree with me that the stairs were a hazard, independent of any approvals.
Thanks for your help, I did fall, my pants leg got caught on the electrical box. [I have ] already had surgery on both shoulders and had not even started on my back problems, Thanks again an I'll let you know what I find out
Jimmy I am so sorry to read of your injuries, though not surprised. While I don't like being asked questions in any mysterious way, in this case, by astutely avoiding telling me anything about what happened to you when you asked my opinion, my answers form an unbiased and unimpeachable opinion that the stairs were a hazard.
And if they have not been amended, the are still a hazard to others.
Particularly because of other details at that stairwell, the hazard is above average: there is no handrailing that one might grab onto at the point of entry to or exit from the stair - I alluded to that earlier, and also the stairs look to be steeper than those used for normal stairways (steeper stairs, even ladders are permitted by some codes for accessing certain areas not normally used by normal building occupants).
Unless you ask me to keep this information offline, I'd like to add the photos and comments to our stair fall articles, keeping your identity and such details totally private of course.
Showing the hazard to others may help prevent other injuries. However if you are in the midst of legal actions I imagine that your attorney might prefer that we wait.
... as for the photos you can use them in any way cause I don't want anyone else to go through that I'm going through it's not worth it and I will let you know the outcome.
Since the doctors told me that I wouldn't be able to continue to work in my field, I was needing help to find something? Thanks again.
Wearing loose sandals, bedroom slippers, socks, and some other shoes increase the risk of slip and fall injuries on stairs
Do not place slippery items such as a rug or towel on a smooth floor at the top of steps or stairways such as the steps shown in our photo (left).
Above, these steps down to the shore of Lake Superior near Two Harbors MN are, at times, made treacherous by weather and wave conditions.
Do not permit stair treads to remain coated or covered with materials that make the steps slippery.
Various industry, ANSI, ASTM, OSHA, ADA standards recommend a static coefficient of friction (SCOF) of 0.5 or higher (ADA 0.6 or above) and define surfaces with SCOF of 0.4 or lower as "low traction", i.e. "slippery".
at SLIPPERY STAIRS, WALKS, ROOFS we give detailed technical data on slippery surfaces. Indoor stair tread slip hazards include high gloss polyurethane coated wood treads, polished stair treads, wet stair treads.
Outdoor stair trip hazards include algae, especially wet algae, ice, snow, water, loose dirt or sand.
See ALGAE ICE FUNGUS WET SURFACES & OTHER STAIR SLIP TRIP & FALL HAZARD for details.
Also see EXTERIOR STAIR FALLS for a catalog of causes of falls on stairs that includes surface conditions and other defects.
Below are wooden steps in a 1790 home restored by the author (DF) in the 1970's.
Coating the antique, hand-sanded pine stair treads left a beautiful deep red-brown surface. But use of high gloss varnish or (in this case) polyurethane on wooden steps leaves a hard, durable, but slippery surface.
Stair tread surfaces of glass, tile, or painted wood surfaces are slippery, especially when wet, and more-so on outdoor steps that are not protected from rain, snow, ice, or algae growth.
More information on slippery stair treads and landings due to moss, ice, water or algae is found
at EXTERIOR STAIR CONSTRUCTION & CODES
and at STAIR PLATFORMS & LANDINGS, ENTRY.
Snag hazards are any projection or obstruction that can catch clothing or a handbag strap as users pass up or down a staircase.
Below, the open hook ends of the stair guard balusters have been seen catching handbag straps.
Please see SNAG HAZARDS on STAIRWAYS for details.
Above these steps entering a Tucson Arizona home include uneven riser height with step risers that are too tall.
Uneven stair or step riser heights, the height from one stair tread surface to the next, is a common and serious trip and fall hazard.
At TALL STEP RISER HEIGHT we have already warned:
The trip and fall hazard caused by stairs whose steps are uneven in height (rise) has been known probably for thousands of years as one discovers it promptly when using uneven-rise stairs without paying close attention to the step height.
That's because people are generally walking on "auto pilot" when going up or down a stairway. Without thinking about it we expect each step to be about the same distance up or down as its neighbours.
More than 3/8 of an inch in variation of the height of steps from one step to another is a tripping hazard recognized in virtually all model stair codes.
See STAIR RISER SPECIFICATIONS for details about proper step riser height and riser uniformity requirements.
The steps shown at above (Spain) were uneven in surface, had no side railing, were too narrow, a bit steep, and had that interesting little swing-out gate (with no platform) leading up to an upper balcony with not much of a railing, as our friend Nuria was contemplating.
Below the author (DF) considers how to walk around a corner on triangular stone stairs in the historic (and long empty of its original occupants and builders) Jewish quarter of Murcia, Spain.
Below: these ancient and rather uneven stairs in Yaxchilan, Chiapas, Mexico, are a challenge for visitors as they were to the people who used them even before tree roots had taken over some of the walking surface.
The presence or absence of visual cues that can inform a walker that she is approaching a step.
Below: the managers of this tourist site near Yaxchilan added a yellow stripe to the front edge of concrete steps whose otherwise consistent color gave a lack of visual clues to stair tread edges.
Examples of "do's and "don'ts" in visual clues that can help prevent stair falls are detailed
at COLOR / LIGHTING CUES AVOID TRIP HAZARDS.
Examples of some of the most egregious stair trip mistakes due to lack of visual cues are shown just below.
The floor shown below has a 4-inch step up.
The same color tiles were used on the floors at both levels as well as on the step riser, making it harder to see the presence of a step, especially in low light and especially for new visitors to this hotel room in Mexico.
Stairs and steps often try to use a color change or a tile layout change to indicate a change. But tile patterns alone can be confusing.
Is the photo above showing a passage between two rooms whose floors are on the same level, or is there as step up or down?
At SLIPPERY TREAD SURFACE we already discussed the hazard of slippery finishes on stair treads such as hard gloss polyurethane or slippery smooth-surfaced ceramic tile stair treads.
Below we illustrate temporal stair slip trip and fall hazards due to weather or weather-related hazards.
These include wet steps (below), snow or ice covered steps, and algae growth on walking surfaces, a result of the combination of water and shade. Interestingly, algae is one of the slipperiest substances known - it has an extremely low static coefficient of traction.
Above, these antique stone steps at Brinstone Farm in St. Weonards in the U.K. combine water from the wet English climate with a bit of algae on the stair tread surfaces.
Below, the ice running across these steps forms a remarkable fall-hazard at this Northern Minnesota state park facility.
Worse, as weather warmed, a thin coating of water atop the ice made walking up or down this stairway incredibly difficult, even when holding on to the handrailing with both hands.
Minnesotans are undaunted by a little smidgen of ice and snow. Later the park put up warning signs that walkers intending to use this stairway needed to be wearing crampons.
Below: snow on these wooden steps doesn't deter visitors in Poughkeepsie, though the hazards are increased by absence of any handrailing.
See SNOW & ICE REMOVAL on WALKS & STAIRS.
But when snow falls over previously iced stair treads the slip and fall hazard is increased enormously, almost as much as when there is water atop hard ice. Below are the same steps under different weather conditions.
More about slippery steps and walks and about algae's SCOF can be read
at SLIPPERY STAIRS, WALKS, ROOFS
Above we illustrate a weenie step, just about 1.25" tall with little visual clue that the walking surface changes height in a building in Akaroa, New Zealand - inspected in 2014. (Those are not the author's toes. )
Barefoot, as our model illustrates, one can badly stub a toe on weenie steps, or while walking with shoes on, the user is at risk of a nasty fall.
This weenie step hazard is exacerbated by the lack of a visual clue that the walking surface height is changing - the floor tiles are the same colour on both levels.
Our page top photo illustrates a stunningly-worn and unsafe wooden stairway. At below left you can see an occupant stepping out through a door that opens out over an exterior stair where a platform was needed.
Be sure to notice that the stone steps are supported on wobbly, tipping and falling-over clay blocks.
[Click to enlarge any image]
Or see these detailed articles on specifications for proper dimensions for stairs, railings, platforms beginning
at STAIR DIMENSIONS, WIDTH, HEIGHT
and
at HANDRAILS & HANDRAILINGS
CONTACT US to contribute images of other types of unsafe stairs or railings. Contributors who wish to remain anonymous may do so. See our PRIVACY POLICY - InspectApedia.com.
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
On 2022-09-26 by InspectApedia (Editor)
@Ellen,
I agree that that's a trip-fall hazard and that you could end up falling down the stairs.
The best fix would be to move the door over to open onto the hallway floor not onto a step down - as any stair modification is likely to be a lot more trouble and cost.
Short of that you can not FIX the hazard but you can reduce it by making darn sure that there is ALWAYS-ON good lighting at the top of that stairwell as well as, of course, over the whole stair run.
On 2022-09-26 by Ellen
We just moved into a rental with an upstairs master bedroom. The doorway faces the stairs, but there is a single step down to a small landing before the stairs begin. At night we have to navigate this and then a single step up to the right to go down the hall to use the bathroom.
I'm scared one of us is going to be too sleepy someday and mis-step. Is there any way we might mitigate the danger?
On 2022-08-01 by InspectApedia-911 (mod)
@Ren,
Thank you for the photo and stair guard/rail safety. I've seen that same design in Mexico and also in the U.S.
No, the stair is not safe and would not comply with U.S. codes; stair code enforcement in Mexico is uncommon, as, perhaps are lawsuits over stair falls.
1. There is no continuous handrail, so the stair user is denied an opportunity to try to arrest a fall.
2. It looks as if the (roughly) vertical cables are more than 4" apart, so the stairway has no functional guard. As a result a child could easily pass through and fall off the stairway.
In my opinion, though cable guards are allowed by the model code, and though I far prefer vertical to horizontal guard members, I think too often they're flexible enough that they can't meet the 4" baluster spacing safety rule.
I can't say with confidence whether or not this spider-web design (don't call it a handrail, as there is NO handrail present) adds its own hazards such as non-graspable surfaces that might cut a hand or pinch a finger or produce a snag hazard, though such might be be contributed by those crossing cables.
This looks like another of many examples of something built for aesthetics that nevertheless is unsafe.
In sum, your stair photo has no functional handrail.
If the architect argues that a stair user can grasp those near-vertical cables, yeah but as there is no continuity the stair user has no safe, graspable handrail. Period. It's nice-looking, though.
At HANDRAIL CONTINUITY
you'll see this non-handrail in San Miguel de Allende in Guanajuato
On 2022-08-01 by Ren
(re-posted by mod with minor edits)
I'm sharing a pic of a "spider-web handrail" design from a fellow architect in Mexico.
Would you say the web servers as a handrail?
In your expert opinion, would you say the web is safe for preventing a fall and not hurting the hand/fingers in a serious way while trying to hold on to it?
On 2022-03-27 by Inspectapedia Com Moderator
@Diane,
Thank you for the helpful question and the remarkable stairway photo.
What an egregious opportunity to fall down the stairs.
In your photo, though the lighting is unclear, I think I see several hazards:
-- In-swing door opens onto
-- a landing too small, less than 36" in the direction of travel away from the door and less than 36" in the direction of the stairway, in fact it's zero inches in the direction of the stairway
-- a landing that directs the walker not to the first step of the stairway but rather into the stairwell opening, with the actual steps several feet away to the left in the photo
I agree with you that these are very serious fall hazards.
In addition we see what I think are
-- a stairway opening seriously under-sized, so much so that it's possible that there is inadequate headroom for stairway users - increasing the injury risk
-- a threshold across the door bottom that perhaps is itself a trip hazard, or it is a step down to the landing that should have been on the same level of the walking surface on the other side of the doorway -increasing the fall risk.
-- to the right in the photo it appears there is a step down from a hallway walking surface (perhaps un used?) to an under-sized (again less than 36") landing that again directs the walker to the stair opening not to the stair step which is instead on the opposite side of the stairway opening.
-- a guardrail that, from the scale of the photo, may be too short, increasing the risk of a fall injury.
You say that the door can't be moved, and I suspect you'll say that as well the stair can't be moved.
If I accept those dilemmas (which if I were at the site and could see more, I might question) then the only improvement that occurs to me is the construction of a right-side-hinged trap door that covers the stairwell to provide a strong and secure walking surface, so that a user has to cross over the covered stairwell opening, then raise the trap door to provide access to duck and go down these stairs.
With the emphasis that we are missing most of the needed information to be confident in the following, I add that when I see such a very unsafe stair and door and guardrail and platform and hallway, those add up to raise the question of whether or not someone has built a sleeping area or occupied space on the uppermost floor of this home in a location and design that would never have been accepted by a building code compliance inspector and thus that may have been built without a permit.
If that is indeed the case I would be alert for other life-safety hazards.
When the situation is calm it may be that a fit person can, with care, get in and out of this upper attic-level space without event, but in the event of a power loss and the need to exit at night, or in the event of the panic of a building fire, the situation could be dire.
I would find a way to move the entire door to the left of the area shown in the photo, correct the stairway opening, check the guardrail construction, and review the home for other in-expert construction features that are unsafe.
Where is this building, and how old is it?
On 2022-03-27 by Diane
Any ideas how to fix this door that opens onto staircase? Door can't be moved as room on other side has steeply pitched roof lines
...
Continue reading at SLIPS, TRIPS & FALLS, EXTERIOR STAIRS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see SLIP TRIP & FALL HAZARD LIST, STAIRS FAQs -questions & answers posted originally at the end of this article.
Or see these
SLIP TRIP & FALL HAZARD LIST, STAIRS, FLOORS, WALKS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.