  (C) Daniel Friedman Insulation Air Leaks on Brick Veneer Walls

Brick veneer wall building insulation specifications & advice:

Tthis article discusses the installation of foam board insulation behind brick veneer walls, and the question of air leaks at the brick ties to the wall.

Our page top photo shows a brick veneer building undergoing demolition - the brick veneer wall ties are visible if you click to enlarge the photograph. No exterior insulation had been installed on this 1950's building at Stewart Air Force Base in Newburgh, NY.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

How Insulate Brick Veneer Walls

The question-and-answer article about insulating a brick veneer wall using foam board, quotes-from, updates, and comments an original article from Solar Age Magazine and written by Steven Bliss.

How do You Keep Brick Veneer Construction Airtight?

Question:

How do you keep brick veneer construction airtight and well insulated when the ties from the brick to the wall studs puncture the rigid foam insulation board and the building's vapor barrier? -- Harold Murray, Bowie MD

Answer:

Foam board insulation (C) Arlene Puentes Daniel FriedmanWith a high-density rigid foam board insulation such as extruded polystyrene
(see POLYSTYRENE FOAM INSULATION),

or foil faced polyisocyanurate insulating board
(see POLYISOCYANURATE FOAM and IAQ), the brick veneer wall ties can be placed on the surface of the foam sheathing and nailed through to the wall studs.

Our photo (left) of foam insulating sheating board was provided courtesy of Arlene Puentes.

This is in accordance with FHA Bulletin 71 for single- and two-family residences.

In especially windy conditions, it may be advisable to increase the number of brick veneer wall ties or use higher-density insulation.

Another option is to nail the ties directly to the studs between each 24-inch course of rigid insulation board.

In any case, the vapor barrier on the warm side of the building wall will not be affected.

Here we include solar energy, solar heating, solar hot water, and related building energy efficiency improvement articles reprinted/adapted/excerpted with permission from Solar Age Magazine - editor Steven Bliss.

The link to the original Q&A article in PDF form immediately below is preceded by an expanded/updated online version of this article.

 




ADVERTISEMENT





Reader Comments, Questions & Answers About The Article Above

Below you will find questions and answers previously posted on this page at its page bottom reader comment box.

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs

On 2017-02-08 by M. Liota

What is the best insulation and vapor barrier for a brick veneer wood framed house that has Blackboard behind the brick?
Thank you


...

Continue reading at BLOCK WALL INSULATION RETROFIT or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Recommended Articles

Suggested citation for this web page

BRICK VENEER WALL AIR LEAKS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.


Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to BUILDING INSULATION

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.

Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification
when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca

Comment Form is loading comments...

Citations & References

In addition to any citations in the article above, a full list is available on request.



ADVERTISEMENT