Brick or block masonry wall insulation retrofit:
This article describes procedures and materials for the insulation retrofit for a brick or block masonry wall cavity.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
The accompanying text is reprinted/adapted/excerpted with permission from Solar Age Magazine - editor Steven Bliss. Our page top photo shows the Sheffield Stable in Saugerties, NY when we inspected it in 2005. This structural brick building was uninsulated and under consideration for restoration.
The question-and-answer article about insulating a masonry wall using foam, quotes-from, updates, and comments an original article from Solar Age Magazine and written by Steven Bliss.
What foam insulation would be appropriate for retrofitting the cavity in a brick and block masonry wall?
How about a 1980's product called Dacotherm, which I heard about a couple of years ago?
- Blair Pollock, Integrated Energy Systems, Chapel Hill NC
Answer:
According to Jerry Carrier, an engineer at the Brick Institute of America in McLean VA, the 1-inch cavity between the brick and the blocks should not be filled with any type of insulation. That space is there to let any moisture that gets into the wall drain out.
If you fill the air space between brick wythes or between a brick veneer and a structural block wall, moisture may be trapped within the wall.
In a freezing climate moisture trapped in a masonry wall can lead to serious structural damage from frost.
Mike Ondra, a designer with the Shelter Design Group, Stoney Run PA, said that although he had heard of some retrofits where the 1-inch cavity in the masonry wall was foamed full of urethane insulation (in the 1970's or 1980's), he had never tried it himself.
Ondra preferred (in a 1985 interview) to stud up an interior 2x3 wall and fill that cavity with foam insulation. The stud wall is build one-inch out from the masonry wall to ensure that the foam forms an uninterrupted thermal break with the outdoor-exposed masonry wall.
Another option is to nail the ties directly to the studs between each 24-inch course of rigid insulation board glued to the interior surface of the masonry wall [discussed at BRICK VENEER WALL AIR LEAKS].
Keep in mind however that insulating inside of a masonry building loses the potentially beneficial effect (in some climates) of the thermal mass of the building.
See THERMAL MASS in BUILDINGS and
see THERMAL MASS WALL DESIGN as
well as THERMAL MASS in HOMES - STUDY.
Solar Age also contacted Diamond Shamrock (Irving TX), the manufacturers of Dacotherm, a loose-fill inert silicate material. They do not recommend the use of Dacotherm in block walls. Dacotherm is biodegradable. If it gets wet it breaks down. It is suitable for dry locations.
Our foam insulation photograph (above) shows testing for air leaks at voids in a spray-applied icynene foam insulation retrofit project.
Here we include solar energy, solar heating, solar hot water, and related building energy efficiency improvement articles reprinted/adapted/excerpted with permission from Solar Age Magazine - editor Steven Bliss.
The link to the original Q&A article in PDF form immediately below is preceded by an expanded/updated online version of this article.
Q & A: How to add Insulation in a Brick or Block Wall: Insulating a Brick Cavity - PDF version, use your browser's back button to return to this page
...
Continue reading at BRICK VENEER WALL AIR LEAKS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
BLOCK WALL INSULATION RETROFIT at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Questions & answers or comments about retrofit insulation for brick or concrete block building walls
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.