Construction Dictionary Section 11 Equipment Construction Dictionary Home Page: https://inspectapedia.com/Design/Construction-Dictionary.php SECTION 11170 AUTOMATIC SENSOR: Devices (electric eye, sonic or others) used to actuate canpact— or when m terial is dumped into charging (NSWMA) chamber. BREAKER BAR: Structural component of s ta— tionary compactor that spans width of charging chamber and serves to break bulky items passing frm the charging chamber into the compactor container . Clearance is provided between the bottom of breaker bar and the top of the ram. (NSWMA) CART DUMPER: A mechanism designed to dump the contents of E ste carts into the charg— ing chamber or hopper of the compactor. Dumper may be at dock level, ground level and/or from end or side. (NSWMA) CHARGING CHAMBER: The loading enclosures of a stationary compactor that m Ids Nterials to be compressed into the compactor con— (NSWMA) tainer. CHARGING HOPPER: An enclosure mounted on top of the compactor charging chamber tha t serves to direct the flow of 11Eteria1s into the charging chamber and reduce spillage (NSWMA) during loading . CHUTE: Structural enclosure over compactor used to guide nzterial into charging com— (NSWMA) pactor. COMPACTOR CONTAINER mlLS: Two longitudin- ax, structural support members, located on the bottom of a compactor container. These rails guide and align the container with the tilt—hoist frame during loading and unloading. Centainer rails also align the container with the compactor. through the container guides. (NSWMA) COMPACTOR FRAE.IE: The structural assembly of a stationary compactor. Encloses the charging chamber, ram and ram actuator The power unit may also be contained with— (NSWMA) in the compactor frame . COMPACTOR LOCKS: Mechanical connectors at— tached to the compactor that couple and secure the container to the compactor (NSWMA) frame . CONTAINER ATTACHING DEVICE: connecting de- vice from tilt—frame to container. May be a cable attachment actuated by a hydraulic winch, hydraulic cylinders or a mechanical bail actuated by a hydraulic cylinder. (NSWMA) CONTAINER-COMPACTOR INTERLOCK SWI TCH: Device used to prevent opera tion of compactor when container is not attached. • (NSWMA) CONTAINER GUIDE: A structure, external to the stat ionary compactor, that properly al igns the container with the cunpactor dur ing the rznoval and replacernent of the con ta iner. (NSWMÄ) 11170 mSTE COMPACTORS Dev ice on container CONTAINER HOLD DOWN: understructure used to mate with hold down locks on tilt—hoist frame. (NSWMA) CONTAINER HOLD DOWN LOCKS: Devices on tilt- frame to mate with locks on container that secure container to tilt—frame for trans— (NSWMA) port. CONTAINER HOIST HOOK: Point on the container for connecting with tilt—hoist lifting mech— anism. (NSWM.A) CONTAINER LOCK: Connecting points on the con— tainer for the compactor locking devices . (NSWMA) CONTAINER OPENING: An opening in the container tai Igate that couples with the discharge (NSWMA) flange of the compactor. CONTAINER ROLLERS: Rollers attached to the bottom of the container to facilitate its movernent dur ing loading and unloading opera— Skids may be used in lieu of rollers. tions . (NSWMA) CONTAINER TAILGATE: Hinged door on the dis- charge end of the container that opens to facilitate the dumping of materials. (NSWMA) CONTROL STATION: An enclosure that contains the controls for operation of the stationary compactor and power unit Control stations can be mounted on the compactor unit or (NSWMA) remotely located. Structure used to CYLINDER SUPPORT HANGERS: connect and support tilt—cylinders to truck frame. (NSWMA) DEODORIZER: Automatic device for releasing odor masking agent into charging chamber . (NSWMA) FLANGE: A frame around the discharge opening of a stationary compactor that serves as an alignment and coupling surface for attaching a compactor container. (NSWMA) Structural platform providing DOCK uMP: access for loading compactor charging cham— ber or hopper. (NSWMA) INSIDE TILT-FRAME HOIST: container support and guide systern whereby the container rails rest on top of the tilt—frame. Container understructure (rails) tracks on inside of container guide. (NSWMA) OUTSIDE TILT-FRAME HOIST; container support and guide system whereby the conta iner under structure (rails) straddles the tilt— (NSWMA) frame and rests on rollers. POWER UNIT : The component of a stationary compactor that furnishes power to actuate the ram. In hydraulically driven stationary compactors, the basic unit would consist of an oil reservoir, electric motor, hy— draulic pump and other necessary hydraulic and electr ical components. (NSWMA) ****** Result for Image/Page 2 ****** SECTION 11170 RAM;. A hydraulic or mechanically actuated com— ponent of a stationary compactor that moves and compresses materials into the compactor con— (NSW>IA) tainer . ACTUATOR: Hydraulic cylinder (s) or mechanical dr ive that moves the ram and provides compaction (NSWMA) forces to the ram face. Integral part of the compactor frame RAM GUIDES: that aligns and/or supports the ram. (NSWMA) Devices (steel bars, cables, canvas RETAINERS : and others) used to block wastes from falling through container opening during transport. (NSWMA) SHEAR BAR: Structural component of stationary compactor that spans width of charging chamber and serves to shear or cut items passing from the charging charnber into the compactor con— tainer. The shear bar is adjacent to the top of the ram. (NSWMA) STABILIZING JACKS: Device used to stabilize truck chassis during pick—up and dump opera— t ions. May be roller attached to tilt—frame or a separate assembly, or hydraulic cylin— (NSWMA) ders with foot plates. STATIONARY COMPACTOR: Power-driven machine de- si gned to compact waste mat erials into a de— tachable container Volume reduction of waste materials is achieved through mechani— cal or hydraulic compression forces. (NSWMA) STATIONARY COMPACTOR SYSTEM: An integrated sys- tem designed to collect, compact, store, trans— port and discharge materials. A basic system consists of waste carts, stationary compactor , tilt—hoist compaction container, and tilt—hoist Figure I illustrates the basic com— frame. ponents Of a tilt—hoist stationary compactor (NSWMA) sys tem . TILT-HOIST FRAME CHARGINa HOPPER WASTE COMPACTORS Structure that supports anq TILT-FRAME: aligns compactor container and elevates for loading, unloading and dumping . (NSWMA) TILT-FRAME PIV0T: Point located at the rear of truck chassis about which the (NSWMA) tilt—frame rotates. TILT-HOIST COMPACTOR CONTAINER: A specially designed container compatible with stationary compactors and tilt— hoist vehicles used to receive, store, and transport compacted materials. The tilt—hoist compactor container is fully enclosed and designed with an opening in the rear discharge door to connect with the stationary compactor . Dis— charge is by gravity or ejection system. (NSWMA) TILT-HOIST FRAME: A tilting frame in- stalled on a standard truck chassis de— signed to pick up, haul, dump and un— (NSWMA) load a tilt—hoist container . WASTE CART: Movable wa ste storage contain— er capable Of dumping into stationary (NSWMA) compa ctor charging chamber. WASTE CART DOCK RAMP PER TILT-HOIST COMPACTOR CONTAINER POWER UNIT FUNCTIONAL COMPONENTS TAILGATE LATCH: Device (NSWb1A) closed. CAR STATIONARY COMPACTOR' CONTROL PANEL møume 1 OF TILT-HOIST STATIONARY COMPACTOR SYSTEM used to lock tai I gate TILT-CYLINDER: Hydraulic cylinders used to elevate til t—frame. (NSWMA) 11170 ****** Result for Image/Page 3 ****** SECTION 11400 AU GRATIN OVEN: Enclosure with hinged door mounted on top of a broi ler. Also cal led (FFCS) finishing oven . Sink—like depression in a PIARIE: table top with a water bath by steam, gas or electr icity into which con— tainers of food are placed to keep foods heated. Often used by chefs as a double boiler. Also called sandwich unit when used for refrigerated foods in sandwich (FFCS) pr epar ati on . (FFCS) See Oven . BAKE OVEN: (FFCS) mKER'S STOVE: see Pot Stove. BAKER'S TABLE: Table whose top has 4 in- ches to 6 inches high curbing along rear and sides to minimize spillage of flour onto floor during preparation. Of— ten furnished with mobile or tilt—out in- (FFCS) gredient bins under the top . Insulated or nonin ted mo— BANQUET CART: bile cabinet with a series of interior shelves and/or racks to hold plates and/or platters of food. usually equipped with an electric heating unit or refrigeration (FFCS) device. BAR WORKBOARD: Equipment below the top of a bar containing sinks, drainboards, cock— tail mix stations, ice storage chests, beverage coolers, glass wa shers, etc. Also called sink workboard. BARBECUE GRILL: A live charcoal or gas- fired, open hearth, horizontal grill having spits set across the top of the unit wi th rotisserie—type drive meckznism along the front working side. (FFCS) BARBECUE MACHINE; see Rotisserie. (FFCS) BEEF CART: Mobile unit, with or withut bottled gas, alcohol or electric reating unit. Used for di splay and slicing of roast beef in the dining rocxn. (FFCS) BEER COOLER: Cooler in which kegs, cans or bottles of beer are refrigerated . The direct draw cooler is a low counter type with sel f—contained tapping equipment and dispensing head (s) • (FFCS) BEER DISPENSER or TAPPING CABINET: Refrigera- ted or ice—cooled insulated cabinet with beer, soda and/or water dispensing heads, drainer plate and pan recessed flush with the bar top and a drain trough under. Usu— ally built into a liquor bar top, between kbo a rd s. BEER SYSTEM: A method for tapping beer from remotely located refrigerated kegs and transporting it through pressurized, re— frigerated and insulated lines to dispens— ing heads located at one or rore stations in the bar and/or backbar . (FFCS) 11400 •BEVERAGE CARRIER: FOOD SERVICE EQUIPMENT (FFCS) . See Carrier . BIN: Sa•ni —enclosed, rectangular or round container , open on top, with or without lift—off, sliding or hinged cover. F 1 oor type bins are usually mobile, of height to roll under a table top. Bins under a baker's table may be mobile or built—in to tilt out. An ingredient bin may be used for flour, sugar, salt, beans, dry peas, etc. A vegetable storage bin has a per forated or screened body. An ice storage bin is fully enclosed and insulated with hinged or slid— ing insulated door (s) at the front; it is normally stationary, and set under an ice— ITEking machine (head) . A silverware (flat— ware) or cutlery bin is snail and mounted in a I-older set on or under counter top with other bins . (FFCS) BLENDER: vertical mixing machine wi th able cup or jar, having mixing and stirring blades in the bottom and mounted on a base with a drive motor. Normally set on a table or counter top. Used in preparing special diets in hospitals, mixing cocktails in bars, as well as to whip or puree food generally at rorte. (FFCS) BLOWER (EVAPORATOR) COIL: see Unit Cooler . (FFCS) BLOWER—DRYER: Motor—driven attachment with a blower and electric— or steamhea ted coil, mounted on top of a dishwa sher for quick drying of ware at the end of the final rinse cyc le . (FFCS) BOARD: A rectangular or round board, small for easy handling, set on a hard surface or count— er top, to prevent dulling the knife blade when cutting food It can be made of lamina— ted or solid hard rock maple, or composition of rubber or thermal plastic material . Usu— ally furnished with a handle or grip. Sand— vich and steam table boards are rectangular and narrow; they are mounted on a sandwich unit or the corresponding section of a counter top . Also cal led Work Board in preparation areas of a kitchen. (FFCS) BOIL—IN—BAG: A clear plastic waterproof pouch containing foods which are heated by immer— sing the package in boiling water. (FFCS) BONE SAW: see Meat and Bone saw. (FFCS) BOOSTER: see Hot water Booster. (PFCS ) BOTTLE BREAKER: Motor—driven device wi th re— volving, horizontal, open top pan, in which enpty glass bottles are safely flogged with steel bars. (FFCS ) BOTTLE CHUTE; Flexible cylindrical tubing to convey enpty bottles from bar to bottle storage bin, or breaking or crushing device. load end is usually located at the cocktail mix station. (FFCS) ****** Result for Image/Page 4 ****** SECTION 11400 BOTTLE CRUSHER: Motor—driven device with rollers or reciprocating plate (s) to crush bottles, The unit is mounted plastic conta iners and cans. on a stand with a waste receptacle beneath to receive crushed ana broken articles. The load— ing chute is provided with a springloaded or (FFC$) gravity—hinged door . System consi sting of bottle SOTTLE DISPOSER: chute and storage bin, bottle breaker or bottle (FFCS) crusher. BOTTLE TROUGH: Trough suspended along the front of a bar workboard, usually at the cocktail mix station, to hold various bottles of liquor or mixer used often. Also cal led Speed Rail. (PFCS) BOWL : A round bottom conta iner open at top for mixing food. The salad bowl is a shallow type for mixing and displaying leafy vegetables. A coffee boul is the lower of a tvo—piece, siphon—type coffee maker, used as a decanter. (FFCS) See Fry Pan, Tilting. BRAISING PAN, TILTING: (FFCS) BREAD MOLDER: Machine with a ser i es Of rollers and conveyor belts to shape the Of dough to pan bread, hearth bread or long rolls of (FFCS) varied length (I) Motor—dr iven machine with a BREAD SLICER: multiple set Of rec iprocating knives in a single frame through which bread is pushed, (2) Motor—driven or nd— or vice versa opera ted machine with a single revolving knife to slice single slices while a bread Ioa f is moved along in a chute by a gear—driven Slice thickness may be varied. (FFCS) plate. BREADING MACHINE; Horizontal rotating cylind er , set on a base with a drive motor and filled with breading mix. Food is placed in one end, carried through the cylinder by an in— ternally mounted auger, and dischar ged at the other end. Food is tumbled in breading mix. (FFCS) BREATH GUARD: see Display case Sneeze Guard. (FFcs) BRIQUETTE: one of the coal-size pieces of permanent refractory material used in open hearth, gas—fired grilles to provide radiant (FFCS ) broiling heat. BROILER, BACKSHELF: Broi ler with gas-Yeated ceramic radiants or electric heating eleænts. Having an adjustable sliding grill. The unit is normally mounted on a panel and brackets above the rear of the range. Also cal led (FFCS) Salamander Broi ler . (1) Hor i zontal BROILER, CHAR or OPEN æÄRTH: type with gas—heated briquettes under a grill at the top. (2) Horizontal type with non— g lowing electric strip heaters at the top May also be equipped with an adj useable elec— tric grill above the top grill to broil both (FFCS) sides at once. 11400 FOOD SERVICE EQUIPMENT BROILER, CHARCOAL: Horizontal type with. removable bottom pan conta ining glowing charcoals to radiate high heat into the bottom of foods set on a grill above. Mounted on stand or enclosed cabinet or (FFCS) masonry base. (1) horizontal type BROILER, CONVEYOR; unit with openings at both ends using a motor—dr iven grill—type conveyor to trans— port food between or under gas—fired ceramics or electric heaters. (2) Hori— zon tal type unit, open at both ends, using a motor—driven, revolving, heated griddle to transport food under gasfired (FFCS ) ceramics or electric heaters. BROILER, POP-UP: Enclosed horizontal type unit with a slotted opening in the top and gas—heated radiants on both sides of the cavity. Food is placed in an elevating mechan ism and broiled on both Similar to a sides at the same ti.me . (FFCS) pop—up toaster. BROILER, PORK AND SPARE RIB, CHINESE: counter— or stand—mounted, narrow depth broiler With 2 or 3 decks, each having gas burners and radiants, for cooking pork sl ices and spare ribs in metal (FFCS ) pla Eter s. BROILER, UPRIGHT: vertical type with an opening at the front, and gas—heated rad i ant ceramics or electric heating Food elements at the top of the cavity . is placed on a sliding adjustable grill set under the radiant s. May be mounted on counter top, oven or cabinet base, or stand. Often aligns with ranges. May be equipped with removable char coal pan . (FFCS) (1) Unit BROILER-GRIDDLE, COMBINATION: with front open ing with griddle plate set into top, equipped with gas—heated radiant s under the griddle. Radiants heat food and griddle simultaneously. (2) Unit with front opening door (s) having gas—heated radiant s at the top of the cavity and food placed on a sl id— ing or swinging type griddle plate set (FFCS) bel ow. BUFFET UNIT : One or more mobile or sta— tionary counters having flat surfaces, with cold pans or heated wells at the top, on which chafing dishes, canape trays or other food displays can be (FFCS ) placed for self—service. BUN DIVIDER: see Roll Divider. (FFCS) BUTCHER BLOCK: Rectangular or round shape——6 inches, 10 inches, 14 inches or 16 inches thick——consisting of hard rock maple strips, kiln—dried, hydra u— lically pressed together, glued and steel doweled through. Work surface of block is surface Of end s Block—mounted on open type of strips. (FFCS) wood or steel legs . ****** Result for Image/Page 5 ****** SECTION 11400 BUTTER CHIP DISPENSER: Enc losed in sulated unit with æchanical refrigeration or ice to hold tiers of butter pats placed on chips, and di spensed one at a time. Nor— mall y set on a counter top. Also called (FFCS) Butter Chip Cooler. CAFETERIA COUNTER, SERVING COUNTER: In a cafeteria, top which is usually provided with recessed cold pans, recessed pans for hot foods section, display and protector cases, and drain troughs for beverages; set on legs or masonry base with enclosure panels, seni— or fully—enc losed cabinets with refrigeration or warming units be— neath; all as required to accormod ate foods Unit may be equ ipped with to be served . (FFCS) tray slide. CAN CRUSHER: Motor—driven machine with rol— lers or reciprocating plates or arms to Unit mounts crush cans and break bottles. on stand with space under for refuse recep— tacle to receive crushed articles. Also (FFCS) called can and bottle crusher. (I) Hand —operated or motor— OPENER : driven device fastened to the top of a table, wall, cabinet, etc., to open in— (2) Portable motor —driven dividual cans. device capable of opening cans while still (FFCS) in case. (I) Enclosed cabinet with spray CAN heads for wa shing the interior and exterior (2) Round of a can, mounted on open legs. platform with a rotating spray head at its center for washing the interior of a can, mounted on a stand with foot—operated water (3) Rinse nozzle built into a floor valves. drain and connected to a hand—operated quick—opening mix ing valve . (FFCS) CAN WASHER AND STERILIZER: Enclosed cabinet with spray heads for washing the inter iors and exteriors of cans, mounted on open legs, provided with detergent dispenser and IBO degrees Fahrenheit hot water rinse or steam mixing valve for final rinse . See Pot and pan Washer . (FFCS) CARBONATED BEVERAGE SYSTEM: see Soda Systzn (rrcs) CARBONATOR: Motor—driven ter pump, wi th tank and control valves, to combine cold water and C02 gas in a storage tank, producing soda Used for soda fountains, car bonated water. beverage di spensers and dispensing systems. (FFCS) CARRIER: A unit for carrying food, beverages and ware by hand for short distances, fur— nished with grip (s) or handle Could be an enclosed cabinet, insulated, heated or refrigerated; or a wire basket or rack. (FFCS) 11400 FOOD SERVICE EQUIPPENT CART : Mobile unit of varying structure; as an open shelf or shelves; a semi—or fGIIy enclosed cabinet with single or mul tiple compartments which may be insulated. Used for transporting food or ware, and for (FFCS) cleaning and storage. CASH DRAWER: Shallow drawer located under a counter top at the cashier end. Often pro— vided with removable compartmented insert for currency and coins. (FFCS) CASHIER COUNTER: see Check-out counter. (FFCS) CASHIER STAND: Mobile or stationary stand with solid top set on four legs, or semi— enclosed body open at bottom. May be pro— vided with foot rest, cash drawer, and tray (FFCS) rest on one or both sides. CEREAL COOKER: Rectangular shaped unit wi th heated water bath, having one or more open— ings in top with lug holders, into which pots with lugs are fitted to prevent the pot from floating. cooker may be gas, electric or Unit may be floor— or wall— steam heated. mounted, and equipped with water filler and (FFCS ) ga uge CHECK-OUT COUNTER: counter located between a cafeteria serving area or kitchen and a din— ing room, for use by checker and/or cashier . (FFCS) Also cal led "Cashier Counter . CHINESE RANGE: Range with one or more large diameter gas burners on an inclined top, and a ra ised edge around each burner opening . Food is cooked in shallow bowls called Woks. Range top is cooled by water flowing from a front rranifold to a rear trough, with strain— er basket at one end. A swing spout faucet mounted on high splashguard at rear fills the bowl when the spout is turned 90 degrees. (FFCS) CHOPPING or CUTTING BLOCK: (FRCS ) See Butcher Block. Device with hand —operated, hinged CAM OPENER: knife and fixed, vee—shaped block attached to a table top. (FFCS) CLEANING CART: Mobile unit with one or more compartments for soiled linen, waste and (FFCS) water for mops and wringer. COFFEE FILTER: Perforated metal container, or disposa ble paper or muslin bag in coffee maker or urn to hold bed of coffee grounds. (FFCS) (I) Bench—mounted, hand or COFFEE GRINDER: motor—dr i ven machine with bean hopper at the top, grinding mechanism, and discharge chute with holder for container or filter beneath. (2) Coffee grinding attachment for a food machi ne . (FFCS) ****** Result for Image/Page 6 ****** SECTION 11400 (I) Hand or automatically operat— COFFäE rmKER: ed, electric—heated unit in which a measure of hot water at the proper temperature is poured over a measured bed of coffee grounds contained The extracted is in a filtering unit. discharged into a container and/or serving unit. (2) Hand or automatically operated, electric— heateä unit in which a measure of hot water at the proper temperature is combined with a mea— sure of anstant coffee mix and discharged into (3) Unit consist ing of one or a container more sets of upper and lower bowls set on gas— or electr ic—heated range. The IIEasure of water boiled in the lower bowl is forced by pressure into the upper bowl containing measured coffee Ehen the set is removed from the heat grounds. source, the cooling lower bowl creates a vacuum, causing the liquid to flow back dom through a filter in the bottom of the upper bowl. The upper is then removed to permit use of the (FFCS) lower bowl as a server or decanter . (FFCS ) COFFEE MILL: see Coffee Grinder. COFFEE PERCOLATOR: covered cyl indrical container with up to 120 cups capacity, electric or gas— Percolat ing device in center causes heated . heated water to flow over measured bed Of coffee grounds contained in a filtering basket Heating Unit is normally hand—filled. at top. Bottom has unit keeps coffee warm for serving. (FFCS) draw—off faucet. coun unit consi sting of one to COFFEE RANGE: four low—rated gas or electric burners for making coffee with siphon—type coffee makers. (FFCS) COFFEE URN: Enclosed container of wa ter with Urn water is hea ted jar (liner) set into top. by gas, electric or s team. A measure Of hot water at proper temperature is poured over measured bed of coffee grounds contained in a Beverage collects in jar and filtering unit. is discharged through bottom connection to draw—off faucet. Urn water is not used for coffee making. Equipped with water inlet valve to fill urn body. (I) Coffee urn wi th COFFEE URN, water inlet valve and additional draw—off fau— cet for hot water to make tea and instant bev— (2) Pressure siphon—type has sealed era ges. water and hot air chambers with piping control (3) Twin type between water jacket and jar. has two coffee jars set into top of single Urn body is usually rectangular conta iner. (4) Automatic type has electrically in shape . opera ted dev ice to pump and mea sure hot water at thermostatically controlled temperature . (FFCS) Counter top range with one or COFFEE WARIER: more gas, electric or canned heaters to main— tain coffee at serving temperature; each with coffee bowl or decanter. Also called (prcsy Coffee Server . Section of bar work— COCKTAIL MIX STATION: board where drinks are poured or mixed. Usu— ally includes open top ice storage bin and veils for mixer bottles and condiments. (FFCS) 11400 FOOD SERVICE EQUIPMENT COLD BEVERAGE DISPENSER OR URN: see Iceg (FFCS) cof fee/Tea Urn. Insulated depressed pan set COLD PAN : into a table or counter top; provided with waste outlet; may be refrigerated with crushed ice, refrigeration coil fastened to the underside of the lining or a cold plate. A perforated false bottom is provided when ice is used. (FFCS) COMBINATION STEAM COOKER and KETTLE: see (FFCS) Cooker and Kettle, Combination. see Condensing COMPRESSOR, REFRIGERATION : (FFCS) Unit, Refr igeration . CONDENSATE EVAPORATOR: Finned coil through which compressed refrigerant flows, ab— sorbing the heat inside refrigerator or (FFCS) freezer . CONDENSING UNIT, REFRIGERATION: Assembly consisting of mechanical compressor dri— ven by electric—powered motor with either (1) Open air or water cooling device. type unit has major components separate (2) Hermetic but mounted on same base. type unit has major components enclosed in same sealer housing, with no external shaft, and motor operating in refrigerant (3) Semi—hermetic type unit atmo sphere. with hermetically sealed compressor whose housing is sealed and has means of access for servicing internal parts in field. (FFCS) CONDIMENT CABINET: semi- or fully enclosed cabinet, mobile or stationary, having several removable or intermediate shelves to store cook' s or baker's condiments and spices in the cooking and preparation (FFCS) areas. CONDIMENT SHELF or RACK: Shelf or rack rounted above or under a table top to hold several condiment items for use by (FFCS) the cook or baker. Standard height mobile or CONDIMENT STAND: stationary stand having a solid top with receptacle for holding condiment contain— ers, and tray rest on one or both sides. May be open type with legs, enclosed type with cabinet base and shelves, or may have insulated cold pan and refrigerated (FFCS) se . see Pot stove. (FFCS) CONFECTIONER'S STOVE: CONVECTION OVEN: Gas- or electric-heated. Heat is circulated through the oven in— terior with fan or blower system. In— ter ior may be equipped with racks and/or shelves. Ovens may be stacked oz set on stand. Oven bottom may be constructed as part of the platform of a mobile bas— (FFCS ) ket rack cart. ****** Result for Image/Page 7 ****** SECTION 11400 CONVENIENCE FOOD: Any food item that has been processed by any method from the raw state, packaged for resale and/or further processing or use at a later date. (FFCS) COOK • S TABLE: Table located in the cooking (FFCS) area of kitchen for cook's use. COOKER and }CTTLE, COMBINATION: one or more steam—jacketed kettles with one or rore steam cookers rounted in top of single cabinet base or top of adjoin ing cabinet May be for direct steam operation, or provided with steam coil, gas or elec— tric heated steam generator in the base (FFCS) under the steam cooker (s) . COOKER/MIXER: Direct steam, gas or elec— tric steam jacketed kettle, with hinges or removable agitator mounted to support— (FFCS ing frame or brackets. COOKIE DROPPER: Motor or hand driven rachine used to portion and shape drops of cookie dough using dies. cookies are dropped onto baking sheet pans or conveyor belt. Also called Cookie Machine. (FFCS) COR.N POPPER: Enclosed unit with transparent front and ends, transparent doors on the side, electrically heated popcorn popper suspended fron the top, and warming heaters for Storage of finished popcorn. May be mounted on counter or enclosed base. (FFCS) COTTON CANDY MACHINE: Machine with round tub and spinning unit, and electric heating unit for converting sugar into cotton can— dy. May be set on counter top or stand. (FFCS) CREAMER: (l) Insulated container for cream, having ice or mechanical refrigeration, and provided with adjustable draw—off fau- cet for each cream measure. Often anchored to counter or Also called Cream (2) Soda fountain unit with Dispen ser . self—contained ice cream cabinet. (FFCS) CREAMER mCK: Rectangular ba sket of wire or plastic construction with compartments to fit glass creamers. Used to wash, fill (FFCS) and store creamers. CRUSHER : See Bottle Crusher, Can Crusher , (FFCS) Compactor, and Ice Crusher. (FFCS) CRYOGENIC FREEZER: see Freezer. CUBING MACHINE: see Dicing Machine. (FPCS) CUTLERY BOX: Unit consisting of one or more compartments for storage and dispensing of flatware (knives, forks, spoons) . Often set on a counter or table top, and some— times built into the front Of a cabinet under the top, or as a drawer. (FFCS) (FFCS) CUTTING BOARD: see Board. 11400 FOOD SERVICE EQUIPMENT (FFCS ) DEEP FAT FRYER: See Fryer. DEFROST SYSTEM: Refrigeration system for a freezer consisting of a blower evaporator Electric— coil, heating unit and controls. type employs heat ing elements; hot gas type uses heat exchanger to remove frost from the coil and allow condensate to flow to the drain pan under the coil. (FFCS) DESSERT CART: Cart with several shelves for display and serving of desserts. May be equipped with mechanical or ice—refrigerated cold pan or plate, and with transparent (FFCS) domed cover. DETERGENT DISPENSER: Device mounted on a dishwasher or sink for storage and dispens— ing of liquid detergent, or mixture of pow— dered detergent and water, into the wash tank of the unit through the pump manifold Some units are or incoming water line. equipped with control device, electrically operated, to detect detergent strength in (FFCS) tank. Bench—mounted hand or motor DICING LACHINE: driven two—operation machine that first for— ces food through a grid network of knives in a square pattern and then slices the food the same length as the side of the square. May be attached to food mixing or cutting ITEchine. Also called Dicing Attachment or Cubing Machine . (FFCS) DISH BOX: see carrier. (FFCS) Cart for storage and dispensing of DISH CART: clean or soiled dishes. Usually of height (FFCS) to roll under counter or table top. DISH TABLE; Work surface with raised sides and end (s) having its surface pitched to a built—in waste outlet, adjoining a sink or Erewashing machine. There may be a soiled table used for receiving, sorting and rack— ing ware, located at load end of the sink or eshing machine; and a clean table at unload for draining of rinse water, drying and stacking ware. (FFCS) DISPENSER: Unit for storage and dispensing of condiments, food and ware. May be insulated and refrigerated or heated. May be provided with self—leveling device. May be counter— or floor-mounted, stationary, or mbile type . (FFCS) DISPLAY CASE: A semi— or fully enclosed case of one or more shelves, mounted on counter semi— top or wall, for display of desserts. enclosed type have transparent end panels and sneeze guards along customers' side to pro— tect uncovered foods. Refrigerated type has insulated transparent panels and doors. Heated type usually provided with sliding doors and electric heating unit, with or without humidifier. (FFCS) ****** Result for Image/Page 8 ****** -1 DOLLY : 11400 Solid platform or open framewrk mounted on a set of casters, for storage and tran spor— tation of heavy items. May be equipped wi th (FFCS) handle or push bar . DOUGH DIVIDER: Motor—driven f ioor—type machine to divide dough (usually for bread) into equal— ly scaled pieces. Pieces are ra•noved from w) rk surface by conveyor to next operation. Normally used for bread dough. Also called Break Divi— (FFCS) der. DOUGH MIXER: (I) Motor—driven machine with ver— tical spindle to which various whips ard beat— ers are attached. BOWI is raised to the agi— tator. Mixers of 5 to 20 quart capacity are bench—mounted. Mixers of 20 to 140 quart ca— (2) motor—dr iven, floor— pacity are floor—type. type morizontal machine with tilting type and horizontal agitator (s) for a large dough batch. Also called Kneading Machine or Mixer. (rrcs) (FFCS) DOUGH MOLDER: see Bread Molder . DOUGH PROOFER: see Proofer, proofing Box or (FFCS ) Cabin et . DOUGH RETARDER; May be upright reach-in, low counter bench—type, or Ik—in refrigerator with series of racks or tray sl ides and/or shelves, in which dough is kept cool, to re— (FFCS) tard rising. DOUGH ROUNDER: Motor—driven, floor —mounted ma— chine into which a piece of dough is dropped and rounded to ball shape, by means of a ro— tat ing cone and fixed spiral racevay running from top to bottom. See Roll Div ider and (FFCS) Rounder. DOUGH SEETER: Motor- or hand-driven machine with a ser ies of adjustable rollers to roll dough to sheets of even thickness. Also called Pie C rust Roller . (FFCS) DOüGE TROUGH; Large tub with tapered sides, usually mounted on casters, for storing and transporting large batches of dough. Some troughs have gates at the ends for pouring dough when the trough is lifted above a divider (FFCS ) and tilted. (FFCS) DOUGHNUT FRYER: see Fryer. DOUGHNUT rüCHINE: Unit consisting of hand— or motor—driven batter dropper and shal low fryer . Doughnuts are conveyed through heated cooking fat or Oil bath, turned over, and discharged (FFCS) out of bath into drain pan . See Drain Trough, Kettle Drainer . (FFCS) DRAINER ; DRINK MIXER: Vertical counter type unit with one or more spindles with motor at top. Switch is activated by drink cup when placed in correct (FFCS) position. Also Malted Mixer. 11400 DROP—IN UNIT: Any warming, cooling, cook— ing or storage unit that is dropped into an opening in a counter or table top and is fitted with accompanying mounting (FFCS) brackets and sized flange. DUNNAGE RACK: Mobile or stationary, solid or louvered platform used to stack cased or bagged goods in a store room or walk— (FFCS) in refrigerator or freezer . EGG BOILER: Electric, steam or gas—heated unit with removable timed elevating de— vice (s) to raise basket (s) or bucket (s) out of bo i ling water bath. Containers Ferris wheel type are lowered by hand. unit will automatically lower and raise baskets through water bath. Also called (FFCS) Egg Timer . (FFCS) See Egg Boiler EGG TIMER: See Microwave Oven. (FFCS) ELECTRONIC OVEN: See Short order Stand . EQUIPMENT STAND: (FFCS) EVAPORATOR: see condensate Evaporator , (FFCS) Unit Cooler. (I) See Juice Extractor . EXTRACTOR : (2 ) See (3) See water Extractor . Grease Filter. (FFCS) (FFCS) See French Pry Cutter . EXTRUDER: (I) Gravity—type has dispos— FAT FILTER: able paper or muslin bag strainer set in Unit is holder on top of fat container. placed under drain valve of fat fryer. (2) Siphon type uses disposable paper or muslin bag strainer over fat container, at— tached to rigid siphon tube mounted on fat fryer, with other end of tube in fat (3) Motor—driven pump—type, port— ta nk . able or mobile, uses disposable paper Has flexible hose from fat stra i ner . Strainer set on fat tank to strainer . (FFCS) container . (1) See coffee Filter. (2) see Fl LTER : (FFCS) (3) See Grease Filter . Fat Filter. FINISHING OVEN: see Au Gratin oven. (FFCS) Hand —operated , sealed FIRE EXTINGUISHER: with chemical inside, most commonly wallmounted and provided with control and directional hose, or horn. (FFCS) (I) Ice—refrigerated, insula ted FISH BOX: cabinet with counter—balanced hinged or sliding door (s) at the top, and drawer (s) (2) Ice or mechani— at the bottom front. call y refrigerated cabinet with tier (s) of self—closing drawers with insulated fronts. Also cal led Fish File. (FFCS ) FISH FILE: see Fish Box. FISH CHIP FRYER; see Fryer. (FFCS) (FFCS) ****** Result for Image/Page 9 ****** SECTION 11400 FLATWARE: Term for knife, spoon and fork (FFCS) used by diner. (I) Unit fixed in a pit, its FLOOR SCALE: platform flush with finished floor. May have dial or beam mounted on top of the housing at the rear of plat fom framing , plus tare beam. Used for weighing heavy (2) Mobile obj ects on mobile carriers. (FFCS) type — See Platform Scale. (FFCS) See Carrier . FOOD CARRIER: (l) Motor—driven bench— or FOOD CUTTER: f I oor—mounted machine with a rotating shal— low bowl to carry food through a set Of ro— tat ing horizontal knives whose axis is per— pen dicular to the radii of the bowl. Knives (2) Motor— are set under hinged—up cover. dr i ven, floor —mounted high speed machine with vertical tilting bowl having a verti— cal shaft with rotating knife. Also called vertical cutter/ mixer or sold under var ious (FFCS) brand names. FOOD FRESHENER. Electrically operated unit to introduce live steam to the exterior or in— terior of food, heating it to serving tuapera— ture without loss of mo isture. Cabinet type has a hinged cover or drawer for warming the HOI low pin—type hea ts exterior of foods. food interior through injection . (FFCS) FOOD MERCHANDISER: Refrigerated, heated or noninsulated case or cabinet with transpa— rent doors, and possibly transparent ends. Used for display and sometimes self—service (FFCS) of foods. FOOD SHAPER: (i) Motor—driven unit with load— ing hopper, bench— or fl oor —mounted. Shape s food into rectangular or round of varying thickness. May be equipped with pa— per interleaving, removing and conveying (2) Attachment to meat chopper devices. to shape ground food into rectangles of varied thickness. Also cal led Food Former. (EFCS) (1) Insulated mobile or station— FOOD WARMER: ary cabinet with shelves, racks or tray slides, having insulated doors or drawers. May be electric, steam or gas heated, and provided with humid i ty control. (2) Infra— red larap or electric radiant reating ele— ment with or without a glass enclosure, mounted above the serving unit in a hot food section. (FFCS) FRENCH FRY BAGGER: Motor-driven machine to convey, measure and insert french fried po— tatoes into paper bag blown open to re— ceive product. (FFCS) FRENCH FRY CUTTER: Hand-operated or rtÜtor- driven machine, or attachment to food ma— chine, that pushes potato through grid Of knives set in square in frame FOOD SERVICE EQUIPMENT FRY PAN, TILTING: Rectangular pan with gas or electric heated flat bottom, pouring lip and hinged cover. Floor—mounted on a tubular stand or wall—mounted on brackets with in —k II steel carriers. A small elec— tric pan may table—mounted on legs. Also called Braising Pan, Tilting Griddle or (FFCS) Tilting Skillet. (1) Floor— or bench—rnounted, unit FRYER: heated by gas or electricity with tank of oil or fat into which foods are irtu:ersed. Corranon type has deep tank. Special types røve shallow tanks for fish, chicken, dough— and a basket conveyor type has nuts, etc., a shallow tank for draining with baskets, arms, resh type belt, or rotating auger to move foods through the bath. pressure type has a lift or hinged cover to seal the top of the fryer tank. (FFCS) FUDGE WARMER: counter-mounted electrically heated insulated pot with hinged or lift— (FFCS) off cover and ladle. GLASS WASHER: (I) Multi—tank horizontal chine with land activated rinse nozzle in one tank, revolving brushes in a second tank, and final rinse nozzles in a third. (2) Single or double tank doortype or rack— (FFCS) conveyor—type dishwasher. GRATER: (1) Bench—mounted hand— or rotor— driven machine in which food is forced against the face of a revolving grater plate by a pusher or Yopper plate. (2) Part of vegetable slicing attachment to food ma— chin e. (FFCS) GREASE FILTER or EXTmCTOR: (1) Removable rectangular or round frame having several layers of wire mesh o: baffles and mounted in the exhaust equipment above or behind cooking units. (2) A ser ies of baf fles mounted in exhaust equipment, from whose surfaces grease deposits are flushed with wash water into a waste outlet. (3) Mani— fold mounted Eter nozzles in exhaust equip— rent producing a fine spray mist which collects grease from laden air and drains through a k ste outlet. (FFCS) GRIDDIE: Extra thick steel plate with a ground and polished top surface, heated by gas or electricity. Sur face edges are raised or provided with gutters and drain roles leading to catch trough or pan. May be set on counter top with legs r stand or oven base . (PFCS ) GRIDDLE STAND; see Short order stand. (FFCS ) GRILL: Bench—mounted unit with fixed lower and hinged upper electrically heated plates. Pla tes have a waffle pattern for waffles, grooves for steaks and are smooth for znd— wiches . (FFCS ) See Broiler, Charcoal. (FFCS) GRILL, CHARCOAL: (FFCS) FæNCH FRYER: see Fryer. (FFCS) 11400 ****** Result for Image/Page 10 ****** SECTIOÄ 11400 (2) (1) See Meat Chopper. (FFCS) Gr i nder . (FFCS) FA•iFER: See Linen haraper See cof f ee ICE ICE ICE FOOD SERVICE EQUIPMENT (FFCS) BREAKER: see Ice Crusher. see ice storage Bin. (FFCS) CHEST : (I) Mechanically re— CREAM CABINET: HEAT EXCHANGER, STEAM: Boi ler with coils to gen- erate clean steam with possibly contaminated house steam. Used for steam cooking units. (FFCS) EIGE SPEED COOKER: BORS a 'OEUVRE CART: (FFCS) see Steam cooker . Cart with platforms on ferris wheel having several food containers on each platform. Used for d i splay and service. (FFCS) (1) counter— NOT CHOCOLATE DISPENSER or MAKER: mousnted electrically heated glass bowl with agitator, or insulated tank with agitator for dispensing premixed hot chocolate. (2) counter— mounted electrically heated unit that com— bi nes mea sure of heated vater with measure of chocolate mix, and dispenses mixture at touch (FFCS ) of button. HOT DOG and HAMBURGER BROILER: semi- or fully enclosed cabinet with glass doors and panels for display. An electric heater under the top r a— diates onto hot dogs in baskets or on pins on wheel, or onto hamburgers laid on platforms mounted on motor—driven ferris wheel. tates while cooking . (FFCS) Food ro— HOT DOG STEZ'ÆR•. counter—mounted cabinet with transparent display panels and hinged covers for doors. The unit is electrically I-pated with a water bath and inner sion device to gener ate steam for hea ting hot dogs, and dry for warming rolls. HOT FOOD CABINET: (FRCS ) See Food Warmer, Carrier HOT FOOD TABLE or SECTION: (Frcs ) See Steam Table. Count er—top and floor—mounted unit HOT PLATE: with one or more open gas or tubular electric burners arranged left to right and/or front French hot plates are round or square to rear. solid steel plates, gas or electrica Ily heated. (FFCS) HOT WATER BOOSTER: Electric, steam-, or gas- heated insulated tank or coil used to rai se the incoming hot water from house tan pera Cure to sanitizing tempera as required by code. Booster may be mounted in side housing or at end of ware washing machine, under ware washing table, or may be remotely located. (FFCS) Cart with one or more semi— HOUSEKEEPING CART; or fully enclosed compartments for clean linen, a compartmented tray at the top for supplies, a cloth hamper for soi led linen, and a waste receptacle . (FFCS) EU}IIDIFIER: Electric, steam or gas heated unit used to evaporate and distribute water inside proof ing equipment and hot food warmers. May (rrcs) be fixed or removable at tachrnent . 11400 frigerated low—type chest with remov— able, hinged, flip—flop covers, used for storage and dispensing of ice cream. (2) Mechanically refrigerated upright cabinet with hinged door (s), for stor— age Of ice cream. (FFCS) ICE CREAM DISPLAY CABINET: Ice cream cabinet with sliding or hinged trans— doors or covers. Mostly used in (FFCS) self—service stores. ICE CREAM FREEZER: Floor- or counter- mounted machine with mechanically re— frigerated cylinder, having a dasher to mix and refrigerate an air—and—ice crean-t mix to flowing ice cream. The product is then placed inside a harden— (FFCS ) ing cabinet ICE CREAM HARDENING CABINET: Low cabinet with a lid (s) or upright cabihet With hinged door (s), insulated and refriger— ated at a very low tempera ture to set (FFCS) ice cream hard. (I) Motor—dr iven or. hand— ICE CRUSHER: operated floor— or counter—mounted ma— chine with spiked rollers, to crush large pieces of ice or ice cubes. (2) Attachment mounted between an ice cube rtEking machine and an ice storage bin, having a damper for directing cubed ice to motor—driven rollers with spikes to crush ice as required. (FFCS) (FFCS) ICE CUBER: see Ice Maker . counter— or wall— ICE DISPENSER: A floor-, mounted stationary ice storage bin with motor driven agitator and conveyor mechanism, or gravity feed, that dis— penses a measure of ice (cubed or crushed) through a discharge chute into a container at working level . (FFCS) counter— or wall— ICE LAXER: Floor - , mounted unit containing refr igeration machinery for making cubed, flaked, and crushed ice. Maker may have integral ice storage b in. Larger capacity ma— chines generally have a separate bin in which ice is received via a connecting Capacity is rated in pounds of ch ute. (FFCS) ice per 24—hour day . ICE MAKER and DISPENSER: Floor-, counter— or wall—mounted ice maker w Storage bin and dispensing mechanism. See Ice (FFCS) Maker, Ice Dispenser . See Cold Pan. ICE PAN, DISPLAY: (FFCS ) ****** Result for Image/Page 11 ****** SECTION 11400 (I) An assembly consisting of a . ICE PLANT: large capacity ice maker that anpties into a walk—in freezer or ice storage bin (s) on the floor below via directional chute (s) . (2) large cepacity, floor—mounted ice rraker, having a small capacity bin connect— ed to vertical and horizontal conveyors with insulated sleeves for transporting ice (FFCS) to large capacity bin (s) . ICE SHAVER: Hand—operated or motor—driven f loor— or bench—mounted machine whose ro— ta ting plate or wheel has a sharp knife which produces ice like snow when forced against the face of a cake of ice. Also (FFCS) called Snow Cone Machine. Insulated mobile or sta— STORAGE ti onary cabinet of one or more compart— ments with hinged or sliding door (s), or It is coramonly mounted under cover (s) . an ice making machine, with opening (s) in the top to receive product (s) and is fitted with a wa ste outlet in the bottom. Ice is normally scooped out of bin. Unit may (FFCS) be built into counter . ICE VENDOR: Floor—mounted, mechanically re— frigerated freezer with a coin—operated mechanism to release a measure of loose or bag of ice cubes at working level. (FFCS) ICED COFFEE/TZA URN: urn with stainless steel or transparent glass jar and draw— Stainless steel type may be off faucet. Glass jar may be equ ipped with insu ice compartment suspended from cover. Also (FFCS) called Iced Tea/ Coffee Dispenser. INFRA-RED HEATER or WARMER: Unit consisting of one or more lamps or electric strip heat— ers, with or without protective covering or reflector, mounted in a bracket or hous— Usually set over hot food serving and ing . display areas, or in side enclosed displays. Unit produces infra—red heat to keep food warm. (FFCS) INFRA—RED OVEN: Oven ha v ing heat generated and radiated from electric infra —red heating elements encased in a glass tube, or from an exposed quartz infra—red plate, See Rinse Injector. INJECTOR, RINSE : INJECTOR, STEN.I: see steam Injector. (FFCS) (FFCS) (FFCS) INSERT: Rectangular pan or round pot se t in — to the top of a steam or hot food table (FFCS) JUICE EXTRACTOR: (1 ) Counter—mounted motor— driven ribbed cone having base with drain hole for juice. Half of fruit is pressed (2) Bench— or by hand, down onto cone . floor —mounted notor driven that slices fruit in half, and squeezes halves (3) Hand operated between nesting cones. bench type machine that squeezes fruit halves between inverted cones. Also called Juicer . (FFCS) 11400 FOOD SERVICE KETTLE DRAINER; Mobile sink with screen. or strainer basket, waste outlet with adjust— (FFCS) able tailpiece, and push handle . (I) Stationary or KETTLE, ELECTRIC HEATED: tilting two—thirds steam jacketed, or sea— tionary full steam jacketed kettle with electric imrnersion heater in water between Kettle is floor—mounted inside housing or attached to housing with tilting mechanism. Tilting device may be hand or Stationary unit is pro— —opera t ed. vided with water filler, hinged cover and draw—off valve. Tilting—type has pouring lip and may have draw—off valve, hinged (2) Sta tionary or cover and water filler. tilting two—thirds steam jacketed kettle set into top of cabinet base with remote electric heated steam generator adjoining kettle. Kettle provided wi th hinged cover , (FFCS ) water filler and draw—off valve. KETTLE, FLAT BOTTOM: Rectangular pan with flat bottom having inner and outer shells. Live steam is introduced bewteen shells, heating inner shell for cooking . Kettle is tilting type, floor—mounted on tubular stand, or wall mounted with brackets and in—wall steel chair carriers. Kettle front has pouring lip. Top has hinged cover. (FFCS) (1) Stationary full or KETTLE, GAS HEATED: On—thirds steam jacketed kettle with a gas burner under the bottom of its outer shell to heat water between shells. The kettle is floor—mounted inside housing and provided (2) with a water filler and hinged cover. Stationary or tilting two—thirds steam jack— eted kettle set into the top of a cabinet base with remote gas heated stearu generator ad— joining the kettle. The kettle provided with hinged cover, water filler and draw-off (3) Stationary floor—type direct— va Ive . fired kettle with e. single shell, mounted inside insulated housing, with a gas burner under bottom of shell, draw—off valve and hinged cover. (FFCS) KETTLE, STEAM JACKETED: Kettle having live steam introduced between the inner and outer shell to heat the inner shell for cooking. Deep type kettle generally is two—thirds Shal low—type kettle generally is jacketed. fully jacketed. May be mounted to the floor with tubular legs or pedestal base, or mounted to the with brackets and in—wall steel chair carriers. Tilting— or trunnion— type may be floor— or wall—mounted, having a worm gear device for hand operation. The stationary kettle has a draw—off valve. The tilting kettle has a pour ing lip and may have a draw—off va Ive. The ke t t Ie may be equipped with lift—off or hinged cover, fill— ing faucet, water cooling system, thermostat, (FFCS) etc. KETTLE, TABLE TOP: Tw—thirds steam jacketed kettle, tilting type, with operating lever up to 20 qt. capacity, or tilting worm gear device for 40 qt. capacity; all direct steam, electric heated. All kettles have ****** Result for Image/Page 12 ****** SECTION 11400 a pouring I ip. Tilting type have 20 and 40 qt. capacity with a lever handle. oyster stewing (FFCS) kettle is shallow tilting type kettle. Steam KETTLE, TILTING OR TRUNNION: Jacketed; Kettle, Flat Bot tom. (FFCS) KNEADING MACHINE or MIXER: see Dough Mixer. (FFCS) Slotted wod or stainless steel KNIFE RACK: bar set away and attached to edge of table top or butcher block. This forms a slot into wh ich cutlery blades are inserted and held up by handles of same while the handles protrude at (FFCS) the top. (l) Bench—mounted, motor— KNIFE SHARPENER: driven machine with rotating stones forming a vee to grind edges on both sides of a blade. (2) Attac?unent to slicing machine. (3) Grind— ing wheel attachment to food machine luving (FFCS) an attachment hub. LINEN CART: Cart wi th several compartments for storage of clean linen. May be semi— or (FFCS) fully enclosed. (1) Stationary or mobile metal LINEN HAFEER: cabinet with hinged metal cover. (2) Sta t ion— ary or mobile framewrk with round cl 0th bag or cloth sides, ends and bottom. (FFCS) LOBSTER TANK: Transparent tank open at the top , and with a water wheel at one end. Tank bot— tom is lined with special sa It. Mounted on a stationary or mobile enclosed base with a filtering and mechanical refrigeration system for tank water. Also called Trout Tank, wi th (FFCS ) salt omitted MACHINE STAND: Mobile or stationary stand with solid or open frame top, mounted on open legs or cabinet base, with adjustable dimensions to suit a specific machine or device. (FFCS) (FFCS) MALTED MIX DISPENSER: Counter- or wall-mounted MIXER, DOUGH: unit with a transparent, covered hopper, hav— ing a lever for dispensing a measure of malt— MIXER, DRINK: (FFCS) ed mix powder. MIXER, FOOD: MEAT and BONE SAW: Floor—mounted, motor driven band saw with upper and loser pulleys, sta— tionary cutting table with gauge plate and (FFCS) movable carriage. IGAT CHOPPER: Table— or floor—mounted, hand or motor driven hor izontal machine. Food placed in top mounted hopper is fed by a stomper into cylinder with tight—fitting auger to drive food against rotating knife and perforated plate. Also cal led Meat Grind er . (FFCS) (FFCS) MEAT GRINDER: see meat Chopper. hEAT HOOK RACK; One or more or metal bars mounted on a wall or floor stand, with fixed or removable sharp pointed retal hooks. Also called Meat Rail, (FFCS) — 10 11400 FOOD SERVICE EQUIPMENT Shallow MEAT ROASTER, STEAM JACKETED: steam jacketed kettle with cover and (FFCS ) draw—off valve. BEAT TENDERIZER: counter-mounted machine having two sets of round knives with spaced cutting edges, set apart on slow speed rollers. Meats are inserted into a slot in the top, pass through the rollers and are discharged at the bottom front through which the meats to be ten— (FFCS) der i zed pass. HENU BOARD: Sign with f ixed or change— able letters or removable lines listing (FFCS the food items and prices. (FFCS) See Water Meter. METER, MEXICAN FOOD MACHINE: Device used to a vee—shaped tortilla when filling (FFCS) it to make a taco. MICROVAVE OVEN: Stand- or counter-mounted oven in which foods are heated and/or cooked when they absorb microwave ener— gy (short electromagnetic waves) genera t— ed by rngnetron (s) . (FFCS) MILK COOLER: (1) Low insulated chest with mechanical or ice refrigeration, for stor— ing and dispensing half—pint to two—quart (2) Counter— or containers of milk. stand— mounted refrigerator with one or more 2— to 10—gaIIon containers equipped with sanitary tube connections which extend through flow control handles for (FFCS) di spensing loose or bulk milk. See Drink Mixer , MILKSHAKE MACHINE: Shake Mixer. (FFCS) MIX CABINET : Low counter—type or upright reach—in refrigerator in which the mix for frozen shakes or ice cream is stored. See Dough Mixer . See Drink Mixer . (FFCS) (FFCS) Motor—driven machine with vertical spindle having several speeds on which various whips and beaters are mounted. Bowl is raised up to agita— tor. Mixers Of 5 to 20 quart capacity are bench—type. mixers of 20 to 140 (FFCS) guar t capacity are floor —type. MIXER STAND: law height stationary or mobile stand with four legs and a solid top to support a mixer up to 20 quart size. May be pr ovided with under shelf and vertical rack for mixer parts. (FFCS) MIXER, VERTICAL CUTTER: see Vertical Cut ter/Mixer . (FFCS) ****** Result for Image/Page 13 ****** SECTION 11400 MIXING TANK: Vertical type has center, bot— tom or side—mounted agitator assembly. Horizontal type has end agitator assembly. All are floor—mounted and provided with re— movable or hinged cover and draw—off valve. Tank may be provided with recirculating pump and filtering system. (FFCS) (FFCS) see Food Slzper. MOLDER, FOOD: MODULAR STAND: Low he ight, open, stationary stand with four or more legs, Izving an open framework top, to support heavy—duty (FFCS) mdular cooking equipment. NAPKIN DJSPENSER: Counter top unit for storage and dispensing of folded paper napkins. Napkins forced to head plate by (FFCS) spr ing. ORDER metal or wood-spoked wheel with clips or hooks on its perimeter, lo— cated between cooks' and servers' areas, on which order sl ips are placed to main— tain rotation and visibility. (FFCS) OVEN: Fully enclosed in sulated chamber with gas, electric or oil—fired heat, provided with thermostatic control. Deck type units have chambers or sections stacked one above the other . Bake type decks are approxima— tely 7 inches high in side. Roast type decks are 12 inches to 14 inches high in— side. (FFCS) (FFCS) OYSTER OPENER: see Clam opener. (I) One or more bars PAN AND UTENSIL RACK : and braces suspended from a ceiling, or mounted on posts or a wall, housing fixed or ranovable hooks for hanging pots, pans (2) Upright mobile or sta— and utensils. tionary unit, open or serni —enclosed, with tiers of angle— or channel—shaped slides (3) Heavy—duty rectangu— to support pans . lar wire basket to hold pans and utensils (FFCS) upright in a pot washer. PAN WASHER: see pot and Utensil washer. (FFCS) PASS-THRU WINDOW or OPENING: Trimmed open- ing between kitchen and serv ing areas hav— May be equi pped ing a shelf for a sill. with hinged or sliding door or shutter. (FFCS) PEANUT ROASTER: Electrically hea ted enclosed display case with hinged cover at the top. (FFCS) PEELER: Floor— or bench—mounted machine hav— ing vertical, stationary, abrasive—lined cylinder open at the top, a motor—dr iven agi— tator bottom plate, and an over—the—rim water supply. Product discharged through door in cylinder side. Waste water is d is— charged at bottom and •may be equipped with a peel trap basket that can be hung on a pipe over sink, or set inside a cabinet base under the pe eler. May also be equipped with garbage disposal unit (FFCS) 11400 - FOOD SERVICE EQUIPMENT (1) Special height mobile. PEELER STAND: stand, open—tne, with four legs (2) Spe— cia1 height enclosed cabinet with adjust— able legs, a door designed to house a trap (FFCS) basket, and a waste outlet. PELLET HEATER: counter-mounted, electric hea ted, insulated cabinet having one or more vertical cylinders in which metallic discs, inserted at the top, are heated. Discs are dispensed at the bottom through drawer type (FFCS) device . see Display case. (FFCS) PIE AND PASTRY CASE: PIZZA OVEN: Bak ing—type oven of one or more or oil—fired, decks, gas— or electric— having ternperature range from 350 to 700 degrees Fahrenheit. Deck (s) are of heat- (FFCS) retaining masonry Iibterial . (FFCS) PIZZA SHEETER: see Dough Sheeter. PLATFORM SCALE: Mobile unit with a dial or beam, for weights up to 1500 pounds. May (FFCS) be floor— or stand—mounted. (FFCS) POPCORN MACHINE: see corn popper. POT AND UTENSIL mSHER, or POT WASHING MACHINE; Machine of one or more tanks with hood or wash chamber above, ins ide which large ware is washed, using very big, high pressure Water is pumped from tanks and spray- pumps . ed over ware placed in racks or set on a con— veyor or platforrn. one or more final fresh water rinses sanitizes ware. Machine has a 34 inch to 36 inch working height. (I) Door— type, single—tank machine has power wash and final rinse only. (2) Door—type, tw— tank Ituchine has power wash and power rinse tanks, and final rinse. (3) Belt conveyor machine is straight—through type machine having one to three tanks plus final rinse . Ware is set directly on a belt. (4) Revolv— ing tray table type has two to three tanks plus final rinse. Ware is set directly on tur ntable platform. (FFCS) POT FILLER: Faucet or valve wi th a hose— mounted at a range, pot stove or kettle to fill a vessel direct. (FFCS ) POT STOVE: LOW, floor—mounted single burner stove with high BTU or KW rating for use with large stock pots. (FFCS ) PREFABRICATED COOLER: Walk-in type refrigera- tor or freezer having insulated walls, ceil— ing and floor fabr icated in a shop and as ser.— bled on the job site. The insulated floor and base of the walls may be constructed as part of the build ing . (FFCS ) Unit located in PREPARATION TABLE or COUNTER: the preparation area of a kitchen, for cutting slicing, peeling and other preparation of foods. (FFCS) ****** Result for Image/Page 14 ****** FOOD SERVICE EQUIPMENT SECTION 11400 RANGE: Unit with heated top surface or Sink constructed or PRE-UASH SINK: burners which heat utensils in which as an integral part of a soiled dish table, foods are cooked, or cook foods direct. located near a dishwashing machine, and fur— Sane ranges are equipped with an insu— nished with removab2e perforated scrap bas— Hot or even heat lated oven base. (FFCS) ket (s) and spray hose. tops, and fry or griddle tops, are gas— or oil—fired, or electrically heated. (FFCS ) See Steam Cooker. PRESSURE COOKER: Open or hot plate tops have electric or gas burners . Fry or griddle tops are (FFCS) see Fryer . PRESSURE FRYER: gas— or oil—fired, or electrically (FFCS) hea ted . Separate machine or built—in section PRE-WASH: of a warewashing machine with tank pump REF.L OVEN: see Revolving Tray oven. (FFCS) or fresh ter supply. Pump recirculates water over fresh water type sprays over REFRIGERATED TABLE: Table top mounted on ware; before pumped wash section of machine . (FFCS) counter type refrigerated base . (FFCS) REPRICERATOR SHELVES: Shelves of wire, PROOF BOX or CABINET: Fully enclosed cabinet solid, embossed or slotted material with gas, steam or electric heater and hu— with reinforced hemrned edges, mounted Sometimes unit may be insulated midifiez . on tubular posts with adjustable sani— type with thermostatic and humidity controls. tar y brackets. May be in stationary or Trave ling type proofer BOX may be mobile. (FFCS) mobile sections. has a conveying mechanism inside the overhead cabinet, as in large cortmercial bread baker. REVOLVING TRAY OVEN: Gas, electric or (FFCS) oil heated oven with a motor—driven ferris wheel device inside having four PROTECTOR CASE: A single shelf mounted on posts or rrore balanced trays. Bake or roast with transparent shield at the front, or pans are loaded and unloaded from a front and ends Mounted over a counter top single opening with a hinged down door . at hot food of sandwich sections to protect Steam may be added for humidity require— (FFCS) uncovered food. (FFCS) men ts of products. PULPER: Floor—mounted garbage and ste d is— RINSE INJECTOR: Device mounted to top or posal machine with a vertical cylinder , side of washing machine for storage and grinder plate and knives, and sump compart— automatic dispensing of liquid water ment for nongrindable matter. Waste rater i al softener into the final rinse manifold. is ground in a deep water bath to forrn a (FFCS) slurry which is piped to a water extractor. Water from the extractor is recirculated to ROAST OVEI*: See Oven; Convection Oven; the pulper . (FRCS) (FFCS) Revolving Tray Oven . QUARTZ OVEN: Oven which employs an electrical Iy P.OÄSTER, MEAT, STEAN JACKETED; see Meat heated quartz plate or infra—red quartz ele— (FFCS) Roaster, Steam Jacketed . ment inside a glass tube to generate heat. (FFCS ) Also called Infra —Red Oven ROLL DIVIDER: Hand or motor operated machine that divides a ball of dough RACK: CUP, DISH, GLASS, PATE or TRAY: Hand operated unit (1) Rectangular or round shaped basket Of into equal pieces. wire or plastic construction, with or with— is stand— or table—mounted. Motor— dr i ven unit is floor—mounted with a out compartments or intermediate later al cabinet base and may be combi ned with supports, used for washing and/or storage a rounding device. Also called Bun of small ware. Racks are self—stacking Divid er. (2) see Tray (FFCS) type for cups and glassware. (FFCS) Rack for upright unit. ROLL WARMER: (1) Enclosed cabinet with a telescoping cover, heated by pellet PAN: see Pan and Utensil Rack. (FFCS) or glowing charcoal under a false bottom. (2) Enclosed insulated cabinet MCK WASHER: Machine Of one or tanks with with electric heating elements and hood or wash chamber over, with one or humidity controls. The unit is provided doors, using large size high pressure pumps, with one or more drawers in a tier at and final sanitizing rinse. Steam or elec— the front; it sets on a counter top, tric heated water is pumped from tanks and legs or a stand, or is built into a sprayed over racks wheeled onto tracks ins ide counter. Also called Bun Warmer. (FFCS) Machine is made to recess in f I oor washer . to have tracks set flush with finished floor. (1) Upright. enclosed cabinet (PFCS) ROTISSERIE: with a vertical grill having gas—f ired ceramics or electric heating elements. A side—mounted motor drives revolving spits set in a tier in front of the 11400 - 12 ****** Result for Image/Page 15 ****** SECTION 11400 heaters. The unit has hinged or sliding (2) Upright enclosed cabinet glass doors. containing a motor—driven ferris wheel provided with food cradles or baskets pass— ing under gas—fired ceramics or electric (3) Enclosed, square, up— heating elements. right cabinet with meat suspended from top in center revolving motor-driven cradle, heated by four infra—red laraps radiating (2) Also see Hot Dog f the corners . (FFCS) and Hamburger Broiler. SALAD CASE: Unit consisting of a refrigerated counter with refrigerated food pans set into the top, and a refrigerated or nonrefrigerat— ed display case mounted on the counter top . (FFCS) SALAMANDER: A backsheif or cabinet mounted over the rear of a range or steara table and absorbing the heat therefrom to keep - 13 foods on it warm. (FFCS) SALAMANDER BROILER: see Broiler, (FFCS) See Meat and SAW, LEAR AND BONE: (FFCS ) SCALE: see Floor Scale; Platform (FFCS) Backshelf . Bone Saw. Scale. SELF-LEVELING DISPENSER: see Dispenser. (FFCS) SERVICE STAND: A stationary cabinet with a solid top at a working height used in a restaurant; may have shelves, bins, drawers and refrigerated section for storage of linen, flatware, glassware, china, condi— (FFCS) ments, water and ice. SETTEE BENCH: Bench with upholstered seat and upholstered back . (FFCS ) SHAKE MAKER: Floor— or counter—mounted ma— chine with one or two mechanically refri— gerated cylinders, having dashers to mix and refrigerate an air—and—milk mixture to a flowing frozen dessert beverage. Unit may be equippeä with syrup tanks and pumps and mixing spindle to blend various f la— vors in shakes. (FFCS) SHRIMP PEELER AND DEVEIIER: Bench-mounted, motor—driven machine that removes vein and shell from shrimp and prawn. (FFCS) SILVER BURNISHER, HOLLOWARE FLATWARE: Ma- chine with a tumbling barrel or vibrating open top tub filled with steel balls and compound, in whcih silver—plated utensils are placed. Tumbling or vibrating action causes steel balls to roll down plating onto base metal. Units may be bench— or floor—mounted, or made mobile to roll under a table top. (FFCS) 11400 FOOD SERVICE EQUIPMENT SILVER WASHER AND DRIER: Floor-mounted Jia- chine with a fixed or removable tumbling drum set inside a wash chamber with a hing— ed cover for washing, sterilizing and elec— trically drying f Iatware. The removable drum has a perforated bottom and top cover . The fixed drum has a hinged cover and per— Machine has wash, rinse and fora ted ends. Electri— final sterilization rinse cycles . call y hea ted air is blown through wash cham— (FFCS) ber and drum to dry flatware . (I) Preparation, Cook's or Utility: SINK: one or two—compartment type with drainboard on one or both sides, each compartment aver— (2) Pot and Pan or aging 24 inches square. Scullery: two, three or four—compartment type with drainboard on one or both sides, and possibly between compartments. Each compartment should be minmum 27 inches left to right, and average 24 inches front to (FFCS) rear. SLAW CUTTER: Floor— or bench—mounted machine with revolving slicer plate and hopper. Cored and quartered cabbage heads inserted in hopper are forced against slicer plate and product discharges through chute below. (FFCS) SLICER: Bench— or stand—mounted machine with a stationary motor—driven round knife and slice thickness gauge plate, and reciprocat— ing feed trough or carriage. Flat trough may have hand and/or spring pressure type feed plate. Gravity trough may have hand or auto— Trough may be hand —operated ætic feed plate. Slicer can be equipped with or motor—driven . automatic stacking and conveying device. (FFCS) SLICER, BREAD: see Bread Slicer. (FFCS) SLICER, VEGETABLE: see Vegetable Slicer. (FFCS) SLUSH MAKER: Floor (counter—mounted machine with one or two mechanically refrigerated cylinders having dashers to mix and refri— gerate a water mixture to a flowing frozen dessert beverage. (FFCS) SMOKEHOUSE, CHINESE : Floor—mounted, enclosed , insulated roasting cabinet with gas burners and baffle plates, hinged door (s) , duct connection and flue at top, and removable grease pan inside the bottom. Meat and f ish and poultry are mounted on skewers ins ide. Interior walls and door have deflector plates to direct drippings into the grease pan . (FFCS) SNEEZE GUARD: See Display Case. (FFCS ) (FFCS) SNOW CONE MACHINE: See Ice Shaver. ****** Result for Image/Page 16 ****** SECTION 11400 (1) Part of soda making and re— SODA DISPENSER: fr{geration system: dispensing head attachment for mounting on a soda fountain, bar, counter or at a waiter station, complete with drainer . (FFCS) fr igez ator . (2) Enclosed cabinet, ice or mechanically re— frigerated, to dispense prenuixed soda or com— STOCK POT STOVE: see Pot Stove. bine soda water with syrup stored in a cabinet (3) Floor— or counter—mounted or remote tanks. cabinet with a self—contained soda and refri— geration system having remote or self—contained (FFCS ) syrup tanks . SODA 24KER: Unit consisting of mechanical refri— geration system, carbonator and soda storage (FFCS) tank . SODA SYSTEM: Assembly consisting of soda maker , syrup tanks, syrup, soda and refrigeration tub— ing, and soda dispensing head (s) and/or cabin— et (s). Also known as Carbonated Beverage system. (FFCS) SOFT ICE CREAM MAKER: Floor- or counter-mounted machine with one or two mechanically refrigerat— ed cylinders having dashers to mix and refri— gerate air and ice cream mix to a flowing fro— zen dessert. Unit is equipped with hand or foot—operated dispensing head or control (FFCS) SOILED DISH PASS WINDOW: Trimmed opening in a par- tition between dishwa shing and serving areas having the soiled dish table as a sill. The opening may be equipped with hinged or sliding (FFCS) door or shutter. SOUP STATION: Section Of cook's table or cafe— teria counter with a hot food receptacle, rec— tangular or round, set into the top. (FFCS) (FFCS) SPEED RAIL: see Bottle Trough. SPICE BFNCH: Table with stationary cabinet above rear or below top, or mobile cabinet (s) under the top. Cabinet (s) have two or more sp ice (FFCS ) drawers or bins. SQUEEZER, JUICE: see juice Extractor. (FFCS) STEAM COOKER: Enclosed cabinet with one or more sealed compartments having individual controls into which (chemically clean) steam is introauced for cooking or hea ting. Cooker may be direct—connected or equipped with gas— fired, electric or steam coil generator in the (2) A cooker with compartments in tiers cooks with low pressure steam. ' Each compartment has a hinged door with a floa ting inner panel anä a sealing gasket made tight with a wheel screw. Unit is floor—mounted, or if direct— (2) Cooker with connected, may be wall—mounted. high pressure has self—sealing door (s) with a gasket made tight by interior steam pressure. May be floor—, counter— or 11—mounted. Also (FFCS) called High Speed Cooker. - 14 FOOD SERVICE EQUIPMENT STEAMER, HOT DOG: see Kot Dog Steamer, . Steam cooker. (FFCS) STEP-IN COOLER/FREEZER: see Walk-in Re- (FFCS) STEAM JACKETED ETTLE: (FFCS) ed . See FOOd STEAMER, DRY: See . Kettle , Freshener. Steam Jacket— (FFCS) 11400 STORAGE üCK: Unit consisting Of one or more shelves mounted on angle, channel or tubular posts, for storage of goods (FFCS) or war e. STOVE: Floor— or counter—mounted unit with one or more open gas or electric (FFCS) burners. Also called Hot Plate. (1) Depression in dish table SWILL TROUGH : approximately 6 to 9 inches wide and 2 to 6 inches deep, equipped with waste outlet, strainer basket, and perforated cover . (2) Extra sink compartment of shallow depth located between compartments of pot washing sink, equipped with strainer (FFCS) basket. TABLE: Top with solid flat surface, mounted on floor with legs, on wall with brackets and legs, or on semi— or fully enclosed cabinet. May be stationary or mobile. May have shelves under, shelves over (FFCS) and tool drawer (s) . TEA or DISPENSER: (1) see Coffee Urn. Same as coffee urn with tea laid in strain— (2) Counter—mounted unit to combine er . instant tea mix with heated water for hot (FFCS) tea or cold water for ice tea. (FFCS) TENDERIZER: see Meat Tenderizer. (FFCS) TIMER, EGG: see Egg Timer. (I) Counter—mounted pop—up type TOASTER: having two or four slice capacity. Elec— (2) Counter—mounted conveyor tric only. type with a motor—driven conveyor carrying the product between electric or gas—fired (3) Sandwich—type: See Grill. radiants. (FFCS ) TRAY MAKE-UP or ASSEMBLY CONVEYOR: Motor- driven or gravity type horizontal con— veyor to transport trays between var ious food loading stations. (FFCS) TRAY RACK: Upright mobile or stationary unit, open or semi—enclosed, having angle, channel or tubular posts and one or more tiers of angle or channel—shaped sliäes to support trays or pans. Rack may be built—in to cabinets or suspended from under table tops . (FFCS) TRAY SLIDE or RAIL: Horizontal surface to accortunodate the width of a tray, extended out from, and running the length of , cafeteria counter top. May be constructed of solid material with or without raised edges and vee beads; or of several tubular or solid rails or bars. Mounted on ****** Result for Image/Page 17 ****** SECTION 11400 and fastened to brackets secured to counter top and/or counter body. Also cal led Tray (FFCS) Rest. TRAY STAND: LOW height mobile or stationary four—legged stand with solid top. Top may have raised back and sides to prevent tray (FFCS) stacks from falling over. (PFCS) TROUGH, swill: see Swill Trough. (F?CS) TROUT TANK: see Lobster Tank. TRUCK: see cart. (FFCS) see Bar Work— UNDERCOONTER SINK WORKBOARD: (FFCS) board. UNIT COOLER: Semi—enclosed cabinet open at front and rear or top and bottom, depend— ing on air flow, with a motor—driven fan blowing air through a mechanically refri— gerated finned coil. Device is normally suspended inside a refrigerator or freez— er. Also called blower (evaporator) coil. (FFCS) URN, COFFEE/TEA: see Coffee urn. (FFCS) URN STAND: Stationary stand with a solid top having raised edges all around, re— cessed drain trough (s) with waste out— let and a drainer plate flush with the top. Raised, die—stamped openings are used to connect lines to an urn. Top set on open base with shelf, semi—enclosed cabinet with bottom (and intermediate) shelf, or enclosed cabinet with bottom (and intermediate) shelf and door (s) . May also be equipped with fold—down step . (FFCS) WORXBOARD : (FFCS) VEGETABLE PEELER: see peeler . WORK TABLE: (l) Hand or VEGETABLE SLICER or CUTTER: motor dr iven counter—mounted machine having rotating renovable plates with Product is forced again St varied knives. plates and knives for slicing, dicing , grating, shredding, etc. (2) Similar attachment to a food machine with rotat— ing removable plates and knife arrange— (FFCS ) men ts. VEGETABLE STEAMER: see Steam cooker. (FFCS) VERTICAL CUTTER/MIXER: Floor-type machine with a vertical tilting mixing bowl hav— ing a 25 to 8 0 quart capacity. The bowl is equipped with a two—speed motor and a high speed agitator shaft at bowl bottom with cutting/mixing knife. A hand or motor—driven stirring and mixing shaft is fixed to the bowl s cover. A strainer bask— ket 11B y be inc luded. (FFCS) WAFFLE BAKER, GRILL OR IRON: see Grill. (FFCS) 11400 - 15 FOOD SERVICE FOUIPMENT WATER BOILER: (l) one or more urns of qoffee urn battery, heated by gas, steam or elec— tricity, to bring water to boil for making beverages. Usually connected to other urns Can be used with water piping and controls. electric—. Steam or separately. oil—fired unit to heat water for use in (FFCS) kitchen . WATER EXTRACTOR: Floor-mounted machine located at the terminal of a waste pulping system. The device augers pulp in a slurry out of the tank to a pressure head at the top, extract— ing water which is then recirculated into the system. The pulp is discharged into a (FFCS) chute to a waste receptacle. 9mTER EATER: Counter—mounted instant elec— tric heating device with faucet for making (FFCS) tea and hot chocolate drinks . Section of a counter or stand WATER STATION : with a glass and/or pitcher filling faucet (FFCS) and drain trough. See Soiled Dish WINDOW, SOILED DISH PASS: Pass Window. (FFCS ) WINE RACK: Fixed or portable folding type unit with alternating stacked compartrents open at front and rear to support wine bottles in a horizontal position for storage and (FFCS) d i splay. (FFCS) WOK: see Chinese Range. WOOD TOP: Table top constructed of kiln—dried, hard rock larainated maple strips, hydrau— lica11y pr essed together, glued and steel (FFCS) doweled through. (FFCS) See Bar Workboard. See Preparation Table. (FFCS)