Water testing strategy:
What should be our approach to testing well water for contamination? - US EPA advice, annotated. Here we give information about drinking water from home wells (also considered private drinking water sources). It describes types of activities in your area that can create threats to your water supply.
This US EPA material also describes problems to look for and offers maintenance suggestions. Sources for more information and help are also listed. [Editing for clarity by DF are marked by brackets or italics] Initial Source: EPA 816-K-02-003 January 2002. Edits, content addition, & web page design
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
Test your water every year for total coliform bacteria, nitrates, total dissolved solids, and pH levels. If you suspect other contaminants, test for these also. Chemical tests can be expensive. Limit them to possible problems specific to your situation. Again, local experts can tell you about possible impurities in your area.
Often county health departments do tests for bacteria and nitrates. For other substances, health departments, environmental offices, or county governments should have a list of state certified laboratories. Your State Laboratory Certification Officer can also provide one.
Call EPA's Safe Drinking Water Hotline, (800) 426- 4791, for the name and phone number of your state's certification officer.
Before taking a sample, contact the lab that will perform your tests. Ask for instructions and sampling bottles. Follow the instructions carefully so you will get correct results. The first step is getting a good water sample. It is also important to follow advice about storing the samples.
Ask how soon they must be taken to the lab for testing. These instructions can be very different for each substance being tested.
Remember to test your water after replacing or repairing any part of the well system (piping, pump, or the well itself.) Also test if you notice a change in your water's look, taste, or smell.
The chart at Reasons to Test Well Water will help you spot problems. The last five problems listed are not an immediate health concern, but they can make your water taste bad, may indicate problems, and could affect your system long term.
This article series gives you general information about drinking water from home wells (also considered private drinking water sources). It describes types of activities in your area that can create threats to your water supply. This text also describes problems to look for and offers maintenance suggestions.
Sources for more information and help are also listed. [Editing for clarity by DF are marked by brackets or italics] Initial Source: EPA 816-K-02-003 January 2002. Edits, content addition, & web page design
Reasons to Test Well Water: Signs of Possible Water Contamination |
|
Conditions or Nearby Activities: | Test for: contaminants related to the specific activity Also see CHEATING ON WATER TESTS For swimming beaches, lakes, ponds, see |
Recurring gastrointestinal illness | Coliform bacteria - See BACTERIA TEST GUIDE and TOTAL COLIFORM TESTING |
Household plumbing contains lead | pH, lead, copper - LEAD CONTAMINATION in WATER, HOW to TEST |
Radon in indoor air or region is radon rich | Radon |
Corrosion of pipes, plumbing | Corrosion, pH, lead - See LEAD CONTAMINATION in WATER, HOW to TEST |
Nearby areas of intensive agriculture | Nitrate, pesticides, coliform bacteria, also |
Coal or other mining operations nearby | Metals, pH, corrosion |
Gas drilling operations nearby | Chloride, sodium, barium, strontium |
Dump, junkyard, landfill, factory, gas station, or dry-cleaning operation nearby | Volatile organic compounds, total dissolved solids, pH, sulfate, chloride, metals |
Odor of gasoline or fuel oil, and near gas station or buried fuel tanks | Volatile organic compounds -ODORS IN WATER |
Objectionable taste or smell | Hydrogen sulfide, corrosion, metals |
Septic system failures or septic too close to well | Sewage, coliform bacteria, nitrates, nitrites - See SEWAGE CONTAMINATION |
Stained plumbing fixtures, laundry | Iron, copper, manganese |
Salty taste and seawater, or a heavily salted roadway nearby | Chloride, total dissolved solids, sodium |
Scaly residues, soaps don't lather | Hardness |
Rapid wear of water treatment equipment | pH, corrosion |
Water softener needed to treat hardness | Manganese, iron |
Water appears cloudy, frothy, or colored | Color, detergents |
...
Continue reading at INTERPRET WATER TEST RESULTS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
WELL WATER TESTING STRATEGY at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.