Basement well (C) Daniel FriedmanComprehensive Water Test Parameters

Parameters included in a comprehensive water potability test:

This article explains the general classes of water contaminants covered in a comprehensive water test. This website describes the types of water testing available, outlines common water test fees, describes the details of what parameters are included in various water test options, and gives advice to assist you in deciding what tests to order.

Our page top photo illustrates a water well found in the basement of an older home. Basement water entry flooded and contaminated this water source.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

Comprehensive Water Test Detailed Parameter List

Comprehensive water testing covering the groups listed below may be appropriate when purchasing a new property, when local environmental conditions are unknown but suspect, or when building occupants have unusual health vulnerability or compromised immune systems.

This article lists the specific parameters of comprehensive water testing that one would consider when attempting to perform comprehensive water testing for a broad range of contaminants.

We advise also that you speak with the local health department and neighbors to ask if there are any known specific issues or contaminants nearby, as we have by this means discovered very unusual local water contaminants which otherwise no one would have thought to test.

Be sure to review actual parameters with your home inspector or laboratory: parameters and costs vary.

List of Parameters in a 

Comprehensive Water Test for Contamination

Water Analysis
Total Coliform

 

Fecal/E. Coli

Benzene

Calcium

Bromobenzene

Copper

Bromochloromethane

Iron

Bromodichloromethane

Magnesium

Bromoform

Manganese

Bromomethane

Potassium

n-Butylbenzene

Sodium

sec-Butylbenzene

Alkalinity

tert-Butylbenzene

Chloride

Carbon-Tetrachloride

Chlorine

Chlorodibromomethane

Color

Chloroethane

Conductivity

Chloroform

Hardness

Chloromethane

Nitrate

o-Chlorotoluene

Odor

p-Chlorotoluene

pH

1,2-Dibromo-3-Chloropropane

Sediment

Dibromomethane

Total Dissolved Solids

1,2-Dibromoethane

Sulfate

m-Dichlorobenzene

Turbidity

o-Dichlorobenzene

Lead

para-Dichlorobenzene

Arsenic

Dichloromethane

Ammonia

Dichlorodifluoromethane

Nitrite

1,1-Dichloroethane

Radon

1,2-Dichloroethane

 

1,1-Dichloroethylene

 

cis-1,2-Dichloroethylene

 

trans-1,2-Dichloroethylene

 

1,2-Dichloropropane

 

1,3-Dichloropropane

 

2,2-Dichloropropane

 

1,1-Dichloropropene

 

1,3-Dichloropropene

 

trans-1,3-Dichloropropene

 

Ethylbenzene

 

Fluorotrichloromethane

 

Hexachlorobutadiene

 

Isopropylbenzene

 

p-Isopropyltoluene

 

Monochlorobenzene

 

Napthalene

 

n-Propylbenzene

 

Styrene

 

1,1,1,2-Tetrachloroethane

 

1,1,2,2-Tetrachloroethane

 

Tetrachloroethylene

 

Toluene

 

1,2,3-Trichlorobenzene

 

1,2,4-Trichlorobenzene

 

1,1,1-Trichloroethane

 

1,1,2-Trichloroethane

 

Trichloroethylene

 

1,2,3-Trichloropropane

 

1,2,4-Trimethylbenzene

 

1,2,5-Trimethylbenzene

 

Vinyl Chloride

 

o-Xylene

 

m-Xylene

 

p-Xylene


...

Continue reading at COMPREHENSIVE + PESTICIDES or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Recommended Articles

Suggested citation for this web page

COMPREHENSIVE WATER TEST at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.


Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to WATER TESTING

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.

Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification
when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca

Comment Form is loading comments...

Citations & References

In addition to any citations in the article above, a full list is available on request.



ADVERTISEMENT