Large Capacity Water Storage Tanks, Selection & Usage Guide

  • WATER STORAGE TANKS, LARGE - CONTENTS: Large water storage tanks: how to provide extra water storage for a building. Using large water storage tanks to handle low-flow wells or a limited water-supply source. Large water storage tanks, extra water storage cisterns
  • POST a QUESTION or READ FAQs about when, why, & how large water storage tanks are used
  • REFERENCES
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

Large water storage tanks: why & when should you install extra water storage capacity at your building? What does the presence of a large water storage tank tell us about the flow rate or yield of a private well?

This article describes the use of extra or large water tanks to store additional water at properties with intermittent or limited water supply from a low-flow-rate well or intermittent municipal water supply.



Green links show where you are. © Copyright 2017 InspectApedia.com, All Rights Reserved.

Large Water Storage Tanks, Why They Are Used, What They Imply about Well Recovery Rate or Well Yield

Apple juice storage tanks, Ductchess County, New York (C) Daniel FriedmanThe large indoor water storage tank shown at page top was contributed by reader Craig Revill and was found in a home that was 80-100 years old. We calculated the water tank volume at about 450 gallons.

What does it mean if you see a huge water storage tank at a property?

Can we use additional water storage tanks to overcome a well that has a very slow recovery rate or a poor well flow rate? Yes we can, with some warnings.

[Click to enlarge any image]

At left we illustrate a huge liquid storage tank observed in Dutchess County, New York. This tank was used for apple juice storage: New York's Hudson Vall

Very large water storage tanks, such as the one whose end is visible in the two photographs below are from two different properties, and are likely to indicate that the flow rate of the well serving the property is very slow, even inadequate by contemporary standards.

Photograph of a storage type steel water tank Photograph of a storage type steel water tank

We've found these old steel tanks at older properties in the Northeastern U.S. in situations where the well flow rate, the rate in gallons per minute at which the well can give water over a sustained period, to be very low, perhaps around one gallon per minute or less.

Very low well flow or well water delivery rates in the 2.5 gpm range or below, simply can't keep up with the rate of water usage in a building during normal occupancy.

Large water tanks may indicate that the well flow rate can't keep up with demand

Worse, if we have only a typical water tank installed, say a 30 or 40-gallon unit, that tank is designed to smooth the flow of delivery of water to the building as the pump is turned on and off.

A small water tank is not sized to actually store a reservoir of water for the building. So if our well flow rate is very low, the building will simply run out of water and occupants will have to wait, perhaps hours, for the pump to re-fill the water tank.

Multiple smaller water tanks may also mean that the well flow rate is poor

Multiple water tanks (C) Daniel FriedmanA more modern solution to poor well flow rate is to install a cascade of two or more individual water pressure tanks in order to provide a larger volume of water stored at a property.

A low flow rate well and pump may rely on "recovery" overnight or over many hours

So a common solution for a low-flow-rate well is the installation of a very large water reservoir. At older properties the single water tank may have been 1000 gallons or even more.

With a large water tank or multiple water tanks installed to provide this water storage reservoir, the well flow rate can be terrible but the building occupants won't see its effect since they're working off of the water storage tank.

At a low-flow-rate well installation the pump will be designed to run at a slow pumping rate so that the well water flow-rate can keep up with the pump as the pump sends water to the water storage tank.

The building occupants use water out of the tank and the tank and well and pump recover their water slowly, perhaps overnight.

Low flow rate wells or slow recovery rate wells at modern properties use a cascade of water tanks

At newer properties this same approach may be taken to "solve" a low-flow well but instead of a single huge steel tank such as the one in this photograph, the plumber will install a series or cascade of from two to perhaps four or five smaller water storage tanks of perhaps 50 gallons each. If you are looking at a property and see that it has five new shiny blue and pretty big water tanks lined up in the basement you can guess that the well is marginal in its delivery capacity.

Low flow rate slow recovery rate wells have a questionable future life expectancy

A final warning about low-flow rate wells: because in many areas water is flowing into the well through cracks in rock below the surface, and because we're starting with an already low recovery rate well, the future ability of the well to give water at all must be questioned. If local water is heavy in minerals, for example, the minerals tend to clog up those rock cracks over time, gradually reducing the water flow-rate into the well still further, until eventually it just stops working.

So a very large water storage capacity at a property is an indicator of both a low-flow-rate well (poor well recovery rate means the same thing), and an indicator that the future usability of the well at all must be questioned. We explain how people determine the necessary water tank size and volume
at WATER TANK SIZE & VOLUME .

OPEN WATER TANKS - gravity fed water systems or pump-up rooftop systems with and without pressure-boosting pumps and water tanks

Sketch of open top water storage tank and well design used both on rooftops and in rural areas.Still More Water Storage Capacity: Rooftop Water Tanks or Free-standing Water Storage Tanks at Ground Level offer increased water storage to mask the effects of an intermittent or slow-recovery water source.

Rooftop water tanks in urban areas such as New York City may be used to supply water at high pressure to the building below.

Water is pumped to the rooftop tank from its municipal source, then redistributed at good pressure to the points of use in the building below.

When passing through New York City, look at rooftops and you'll often see these tanks still in use. This sketch shows how a rooftop tank might be constructed, though this particular sketch has the tank next to a well.

Details about rooftop & tower - mounted water tanks are at ROOFTOP WATER TANKS

Also see related details at CISTERNS.

...


Continue reading at WELL YIELD IMPROVEMENT or select a topic from closely-related articles below, or see our complete INDEX to RELATED ARTICLES below.

Or see ROOFTOP WATER TANKS

Or see PLASTIC CONTAINERS, TANKS, TYPES where we describe health and other concerns involving plastic tanks and other containers used for water storage.

Or see WATER QUANTITY IMPROVEMENT

Suggested citation for this web page

LARGE CAPACITY WATER STORAGE TANKS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

INDEX to RELATED ARTICLES: ARTICLE INDEX to WATER SUPPLY, PUMPS TANKS WELLS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia


...

Frequently Asked Questions (FAQs)

Click to Show or Hide FAQs

Ask a Question or Search InspectApedia

Questions & answers or comments about when, why, & how large water storage tanks are used.

Use the "Click to Show or Hide FAQs" link just above to see recently-posted questions, comments, replies, try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Comment Box is loading comments...

Technical Reviewers & References

Click to Show or Hide Citations & References

Publisher's Google+ Page by Daniel Friedman