How Frequently to Add Air to a Water Pressure Tank
How often should I need to add air to my water tank?

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

Water tank air addition schedule:

This article explains how often to add air to a building water pressure tank, and how to detect and correct air and water leaks in a building water supply system where a private well is the water source.



Green links show where you are. © Copyright 2017 InspectApedia.com, All Rights Reserved.

HOW OFTEN TO ADD AIR - How often is the addition of air needed in a water tank?

Frequency of Adding Air to Bladderless Steel or Fiberglass Water Tanks

When your water tank is a conventional older style that does NOT use a "captive-air" type bladder, unless there's a leak at the water tank you shouldn't have to add air again for months or maybe even a year.

The frequency with which you'll need to add air depends mostly on how much water is used.

Eventually air in this older type of tank gets absorbed into the water, losing the cushion effect and generating a need for more air.

Frequency of Adding Air to Captive-air Bladder-type Water Tanks of Steel, Plastic, or Fiberglass

Captive-air or bladder type tanks should never need air added. If you keep having toadd air to a bladder-type tank something is wrong with the system, perhaps a torn or leaky water bladder in the tank or a leak in the steel tank body that is losing air.

The pressure tank's internal rubber bladder contains water, the steel tank body contains the air charge.

Key Water Tank Air Charge or Waterlogged Water Tank Diagnosis & Repair Articles

There are fancier methods than those described below but here are three simple methods, of which the second two work well for easy replacement of air lost from a bladderless or glass-lined steel water storage or pressure tank.

Bladder type or "captive air" water tanks do not normally need to have makeup air added but if you are finding short cycling on a bladder-type water tank system, if the problem is not in the pump control or water piping, the problem may be traced to a failure of the internal bladder itself - a component that may be replaceable. In that case adding air to the bladder type water tank won't correct the problem.

Readers of this document should also see WATER PUMP REPAIR GUIDE an specific case which offers an example of diagnosis of loss of water pressure, loss of water, and analyzes the actual repair cost. The illustration at page top is courtesy of Carson Dunlop, Inc. in Toronto.

...


Continue reading at WATER TANK AIR INLET VALVE or select a topic from closely-related articles below, or see our complete INDEX to RELATED ARTICLES below.

Suggested citation for this web page

WATER TANK AIR HOW OFTEN TO ADD at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

INDEX to RELATED ARTICLES: ARTICLE INDEX to WATER SUPPLY, PUMPS TANKS WELLS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia


...

Frequently Asked Questions (FAQs)

Click to Show or Hide FAQs

Ask a Question or Search InspectApedia

Questions & answers on how often you should add air to a water pressure tank

Use the "Click to Show or Hide FAQs" link just above to see recently-posted questions, comments, replies, try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Comment Box is loading comments...

Technical Reviewers & References

Click to Show or Hide Citations & References

Publisher's Google+ Page by Daniel Friedman