POST a QUESTION or COMMENT about tracking down other water odors such as chlorine, bleach, musty smell, moldy smell, soapy smell, etc.
Other water odors & smells, diagnosis & remedy:
How to Identify & Cure Other Smells & Tastes in Drinking Water. Here we describe other, less common sources of water odors or smells.
This article series, beginning at WATER ODORS discusses how to identify, diagnose, and cure common as well as unusual odors that may be present in drinking water.
We also
discuss which of these odors may warn of unsanitary conditions.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
Other Common Water Smells or Odors
Let's take a closer look at some other reasons why drinking water may be smelly be and what you should do.
Chlorine odors in drinking water:
While we can't cover all of the possibilities here, we can talk about some different odors and their causes. If your water smells
like chlorine, you're most likely on a municipal system and it is chlorine that you smell.
Chlorine is quite volatile and doesn't stick around in water - if you run water from a tap into a pitcher and let it sit, the
chlorine will dissipate pretty quickly. People who want to avoid chlorine in their water can install a treatment system
such as charcoal filtering to remove it.
If your home water smells like chlorine and you have a chlorinator installed for water disinfection, make sure the equipment is properly adjusted.
If you have just shocked your water well to try to sanitize the wellit is possible that you have not run enough water to flush out all of that chlorine (bleach).
If you have just followed the procedures
at SANITIZE the WATER SOFTENER it is possible that you have not run enough water to flush out all of that chlorine (bleach).
A musty, dank, or brackish odor in water is often
times attributed to chloride in your water, but it could also be 2-methyl-isoborneal (MIB).
A sweet, organic smell in water might indicate
m-xylene, and styrene in your water will make you think of model airplane glue.
A "greenish -chlorophyll-like" odor in water might be grass
in your well, but is probably an algae growth.
Soap or rubber odors in water:
Some things are just what they smell like, for example soap will smell like soap, and
rubber hose will smell like rubber hose!
Other sources of odors in water are discussed in our edited EPA article on water pollution: see WATER POLLUTANT SOURCES for those details.
Before Buying Water Treatment Equipment
A water treatment company will often be willing to test your water and will recommend just what equipment you need.
Just be sure first that the odor source is a problem in your water source and not in the building piping or equipment.
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed:if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted. Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.
Scott Bradley, author. Scott Bradley is Laboratory Director for Aquacheck Laboratory, Inc. PO Box 87 05151 1-800-263-9596.
A more brief version of this article appeared in Aquacheck Laboratory's Water Wisdom Tips and Newsletter, Issue # 6, 2007. www.Aquacheck-VT.com offers other water supply tips in its Water Wisdom section.
The laboratory also provides water test kits and offers a free newsletter.
Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested
Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. Tel: (416) 964-9415 1-800-268-7070 Email: info@carsondunlop.com. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
Carson Dunlop Associates provides extensive home inspection education and report writing material. In gratitude we provide links to tsome Carson Dunlop Associates products and services.