InspectAPedia.com InspectAPedia®
Google
InspectAPedia
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • DAMAGE ASSESSMENT
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US



InspectAPedia ® Home

WATER PUMPS, TANKS, TESTS, WELLS, REPAIRS

FILTERS, WATER
GREYWATER SYSTEMS

WATER CONTAMINANT LEVELS
WATER FILTERS
WATER HAMMER NOISE DIAGNOSE & CURE
WATER HEATERS
WATER ODORS, CAUSE CURE
WATER PUMP REPAIR GUIDE
WATER PRESSURE LOSS DIAGNOSIS & REPAIR
WATER PUMP SHORT CYCLING
WATER PURIFIERS
WATER SOFTENERS & CONDITIONERS
WATER TANK REPAIR PROCEDURES
WATER TANK: USES, TROUBLESHOOTING
WATER TESTS, CONTAMINANTS, TREATMENT
WATER TREATMENT EQUIPMENT CHOICES
WELLS CISTERNS & SPRINGS
WELL FLOW RATE
WELL WATER PRESSURE DIAGNOSIS
WELL YIELD IMPROVEMENT
WINTERIZE A BUILDING

More Information

Distiller (C) Daniel FriedmanMunicipal Water Test Parameters
     

  • Municipal Water Test Parameters
    • Should you order private testing for municipal water in your home
    • Water test choices & alternatives
    • Costs & of various water tests
  • Questions & Answers about both public & private testing of city or community water supplies
  • References

Click to Show or Hide Related Topics

  • WATER TESTS, CONTAMINANTS, TREATMENT - home
  • CHEATING ON WATER TESTS
  • CHLORINE SOURCES in DRINKING WATER
  • CHLORINATION WELL SHOCKING PROCEDURE
  • CORRECTING BAD WATER
  • DEBRIS in WATER SUPPLY, Water Heater
  • WELL WATER CONTAMINATION: CAUSES, CURES - home
  • FAILED WATER TESTS - WHAT TO DO
  • FAILED WATER TESTS - WHEN to RE-TEST
  • LEAD POISONING HAZARDS GUIDE - home
  • ODORS IN WATER
  • SEWAGE CONTAMINATION
  • WATER CONTAMINANT LEVELS
  • WATER FILTERS
  • WATER PRESSURE LOSS DIAGNOSIS & REPAIR - home
  • WATER PUMPS, TANKS, TESTS, WELLS, REPAIRS - home
  • WATER PURIFIERS
  • WATER QUALITY TESTS, CONTAMINANTS
  • WATER QUANTITY TEST: WELL FLOW TEST
  • WATER TEST CHOICES & WATER TEST FEES
    • ARSENIC in WATER
    • BACTERIA TEST GUIDE
    • BOD WASTEWATER TEST
    • BPA, Bisphenol-A
    • CHEMICAL CONTAMINANTS in WATER
    • CHLORAMINE / CHLORINE Tests
    • COMPREHENSIVE WATER TEST
    • COMPREHENSIVE + PESTICIDES
    • CONTAMINANT CLASSES, in WATER
    • CORROSIVITY or ACIDITY of WATER
    • COST of Water Tests - Lab Fees
    • FHA WATER TESTS REQUIRED
    • GENERAL WATER TEST PARAMETERS
    • HARDNESS of WATER
    • HERBICIDE CONTAMINATION
    • HPC Heterotrophic Plate Count Bacteria
    • INDIVIDUAL WATER TEST PARAMETERS
    • LEAD CONTAMINATION in WATER, TEST
    • MINERAL CONTENT of WATER
    • MUNICIPAL Water Test Parameters
    • PESTICIDE CONTAMINATION
    • PESTICIDE TESTS
    • STANDARD VA FHA, PESTICIDES
    • TITLE 5 WATER TEST PARAMETERS
    • TOTAL COLIFORM TESTING
  • WATER TEST FEES
  • WATER TESTING ADVICE
    • SHOULD YOU TEST YOUR WATER?
    • PUBLIC vs PRIVATE WATER
    • WHEN TO TEST
    • WATER TEST COSTS
    • SPECIAL SITUATION TESTS
  • WATER TESTING GUIDE
  • WATER TEST INTERPRETATION
    • COMMON BACTERIA TESTS
    • PA - Coliform Bacteria Test
    • M.F.T. - Coliform Bacteria Test
    • MPN - Coliform Bacteria Test
    • INTERPRET Other Water Test Results
  • WATER TREATMENT EQUIPMENT CHOICES - home
  • WELL WATER CONTAMINATION: CAUSES, CURES - home
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

What drinking water contamination tests should you order? This article explains the water contaminants covered in a municipal water supply testing.

Readers should also see our longer article Water Quality Testing, and advice for home buyers and building owners: water contaminants, water test procedures, well shock procedures, preventing drinking water contamination, and Cheating on water tests in that document.

Green links show where you are. © Copyright 2013 InspectAPedia.com, All Rights Reserved. Author Daniel Friedman.

Municipal- water test parameters - how to check for pesticide contaminants in drinking water

Normally we would not test water in a property served by a municipal supply, as federal, state, or other regulations require thorough and frequent testing that is more extensive than a private individual is likely to employ.

However for small water systems such as those serving a limited number of homes, and particularly where the water supply system is being privately managed by a local firm or by a local property manager, some screening tests may be appropriate. This would be particularly true if a review of the history of local testing and water sanitation by the local provider raises questions about the accuracy and thoroughness of the water management company.

The water test parameters listed below are typical state testing requirements for municipal water supply testing. Be sure to review actual parameters with your home inspector or laboratory: parameters and costs vary. More in-depth, un-biased, expert information on these topics and on building defect inspection, diagnosis, & repair can be found at "More Information" below. © 2010 Daniel Friedman, All Rights Reserved

Testing Municipal for Contaminants - Water Test Parameters

Water Analysis

 
 

Total Coliform

Fecal/E. Coli

Calcium

Copper

Iron

Magnesium

Manganese

Potassium

Sodium

Alkalinity

Chloride

Chlorine

Color

Conductivity

Hardness

Nitrate

Odor

pH

Sediment

Total Dissolved Solids

Sulfate

Turbidity

Lead

also see

  • CHLORINE IN DRINKING WATER - Does Chlorine in Drinking Water Harm the Septic Tank? - Septic Tank Cleaning Advice
  • CHLORINE IN SEPTIC WASTEWATER - Septic Tank Maintenance: Chlorine in Septic Systems - Septic Tank Maintenance Advice

...


Frequently Asked Questions (FAQs)

...

Ask a Question or Search InspectApedia

Questions & answers or comments about both public & private testing of city or community water supplies.

Ask a Question or Enter Search Terms in the InspectApedia search box just below.

Technical Reviewers & References

Related Topics, found near the top of this page suggest articles closely related to this one.

  • 1-Bromo-3-chloro-5,5-dimethylhydantoin (C5H6BrClN2O2) is produced world-wide and is also used in cleaners and bathroom disinfectants and deodorizers. Here is an example MSDS for this product, provided by Leisure Time
  • "Bacteria in Drinking Water" - "Chlorine," Karen Mancl, water quality specialist, Agricultural Engineering, Ohio State University Extension. Mancl explains factors affecting the effectiveness of chlorine in water as a means to destroy bacteria and other microorganisms. OSU reports as follows:
    • Chlorine kills bacteria, including disease-causing organisms and the nuisance organism, iron bacteria. However, low levels of chlorine, normally used to disinfect water, are not an effective treatment for giardia cysts. A chlorine level of over 10 mg/1 must be maintained for at least 30 minutes to kill giardia cysts. -- http://ohioline.osu.edu/b795/index.html is the front page of this bulletin
  • "Chemicals and Our Health", Nicholas D. Kristof, New York Times, 16 July 2009, p. 27. This outstanding editorial calls for improvements in public health policy to address phthalates and other environmental contaminants from common chemicals and products in everyday use. - DJ Friedman
  • Crystal Clear Supply provides portable ceramic water filter purifiers and portable reverse osmosis water treatment equipment - see http://www.crystalclearsupply.com/category_s/7.htm
  • CHLORINE IN DRINKING WATER - Does Chlorine in Drinking Water Harm the Septic Tank? - Septic Tank Cleaning Advice
  • CHLORINE IN SEPTIC WASTEWATER - Septic Tank Maintenance: Chlorine in Septic Systems - Septic Tank Maintenance Advice
  • Cheating on water tests: Testing Water for Real Estate Transactions - make sure your water test is valid
  • Chlorinate or Shock a Well, When, How-to - Procedure for Shocking a Well to (temporarily or maybe longer) "Correct" Bacterial Contamination
  • Choices of Water Tests & Fees: A Summary of Types of Water Tests, Degrees of Comprehensive Water Testing, Details of Water Test Parameters
  • Correcting Unsatisfactory Water what to do, when to do it, treatment alternatives, equipment, filters, etc.
  • Disinfectants in water: www.epa.gov/ogwdw/mdbp/pdf/alter/chapt_2.pdf provides an article on use of disinfectants for water treatment
  • Drinking Water Contaminant Levels - Maximum Allowed
  • Drinking Water Contamination and Pollution How to Detect, Test, Correct, and Prevent Well Water Contamination - US EPA - Groundwater
  • "Drinking Water Safety in Emergencies", University of Minnesota extension, extension.umn.edu/info-u/nutrition/BJ646.html
  • Drinking Water testing, contamination, correction - all topics
  • Drinking Water Testing Advice for home buyers home owners home inspectors
  • Endocrine Disruptor Exchange, Dr. theo Colborn (also see Our Stolen Future). From that website: The Endocrine Disruption Exchange, Inc. is the only organization that focuses primarily on the human health and environmental problems caused by low-dose and/or ambient exposure to chemicals that interfere with development and function, called endocrine disruptors. ... TEDX's work focuses on the endocrine system, which is the exquisitely balanced system of glands and hormones that regulates such vital functions as body growth, response to stress, sexual development and behavior, production and utilization of insulin, rate of metabolism, intelligence and behavior. Hormones are chemicals such as insulin, thyroxin, estrogen, and testosterone that interact with specific target cells. The interactions occur through a number of mechanisms, the easiest of which to conceptualize is through a lock and key arrangement.
  • Giardia exposure limits for drinking water: see www.mass.gov/dep/water/drinking/standards/giardia.htm is the current regulatory exposure limit (your minimum target for sterilization)
  • Health Effects of Chemical Contaminants in Drinking Water, US Environmental Protection Agency,
  • How to Reduce Lead Contamination in Drinking Water: how to test & correction lead in drinking water
  • Hydrogen peroxide: Wikipedia on history of use of hydrogen peroxide: Information on Hydrogen peroxide as a sterilant is in Wikipedia at en.wikipedia.org/wiki/Sterilization_(microbiology) HO2 has been used for a long time, including by vaporization for sterilizing freeze dryers.
  • Hydrogen Peroxide warning: US FDA Warning about drinking hydrogen peroxide: www.truthorfiction.com/rumors/h/hydrogen-peroxide.htm This article cites a 2003 entry in Journal of Food and Science on using Hy.Perox to sterilize vegetables, referring to E.coli - NOT to Giardia.
  • Iodine: "Do Iodine Water Purification Tablets Provide an Effective Barrier against Cryptosporidium parvum?", Starke, Jeffrey A., Bowman, Dwight D., Labare, Michael, Fogarty, Elizabeth A., and others, Military Medicine, 25 October 2001 [possibly a later version of this article appeared in 2005 -DF] http://www.amsus.org/military medicine/milmed.htm
  • Interpreting Drinking Water Test Results what the results mean and what to do about them
  • Lead Contamination from Water Supply Lines/Entry Mains, Lead Testing & Correcting Contamination from - Lead Pipe Problems/Advice
  • Lead Poisoning: Extreme Lead Poisoning Symptoms Suggested by Feb 2006 NY Times Article on Kosovo Roma Camps
  • National Primary Drinking Water Regulations- The complete regulations regarding these contaminants available from the Code of Federal Regulations Website -(United States)
  • Ohio State University article on the concentration of chlorine necessary to act as an effective disinfectant, and the effects of the water's pH and temperature: See http://ohioline.osu.edu/b795/b795_7.html for details.
  • Our Stolen Future: Are We Threatening Our Fertility, Intelligence, and Survival?--A Scientific Detective Story, Theo Colborn, Dianne Dumanoski, John Peter Meyers. Plume-Penguin Publishing, 1997, ISBN 0-452-27414-1., ISBN13: 9780452274143. This book is a seminal work on endocrine disruptors (chemical contaminants having impact at extremely low levels in the environment).
    Recommended by Daniel Friedman, this book is a critical update to the landmark Silent Spring by Rachel Carson and discusses the effects of minute trace amounts of chemical contaminants in the environment. The text "Identifies the various ways in which chemical pollutants in the environment are disrupting human reproductive patterns and causing such problems as birth defects, sexual abnormalities, and reproductive failure. Reprint. Tour. NYT."
    Amazon.com Review: By O T (Ontario, BC) - 'Our Stolen Future' is a great introduction to one of the most important scientific discoveries in our time. Having recently completed a thesis project at university on Endocrine Disruptors, I have reviewed hundreds of papers on the subject. This book is a good clear overview of the scientific literature on EDs. The authors are experts - Theo Colborn is largely responsible for creating the field by bringing together diverse researchers so they could see the big picture of their work. Many of the principle investigators are interviewed and quoted at length on the way chemicals participate in and interfere with delicate hormonal systems in animals (including humans). The major accomplishment of the book is to make an easy-to-follow story out of complex research. Many resources are available to help you assess the reliability of this story, and the best thing to do if you have any doubts is read review articles in scientific journals (which are easier to understand than technical papers). The Physicians for Social Responsibility (PSR) have a guidebook for health-care professionals on Endocrine Disruptors, and the US EPA has many reports on the matter. Beware of people or websites who try to 'debunk' this book (or the science behind it) by simply declaring it false, flawed or disproven. There is far too much supporting research for so simple a refutation.
    OPINION: Significant and discussed in this book is the observation that at certain critical points in the development of animals, presumably including humans, exposure to extremely low levels of endocrine disruptor chemicals (EDC's) (such as BPA - Bisphenol-A or BPA, Diethylstilbestrol - DES, dioxins, PCBs, and chemicals used in the production of certain cleansers, dyes, flame retardants, plastics, pesticides, white papers ) perhaps just a few molecules, or in the parts per trillion, is sufficient to cause disruption of the animal's development, including proper sex differentiation, or the lack of it that produced androgynous ducks unable to reproduce under such conditions.
    A endocrine disruptor is a synthetic chemical compound that mimics natural hormones when it is taken into the body of a human or other animal. It "disrupts" the endocrine system by turning on or off normal chemical signals that in turn can affect normal hormone levels, bodily functions, and significantly, the development of embryos. Further, unlike naturally occurring hormones ingested, for example from plants (phytoestrogens), synthetically-generated hormones accumulate in the body and can have a half-life of decades or longer.
    One significance of this finding includes the observation that an important medical effect that occurs with exposure to chemicals in extremely low concentrations means that experiments to test for correlations between chemical exposure and subsequent serious medical problems will be deeply flawed if, for example, the experimental design does not include testing for the presence of the chemical at extremely low levels. A related concern is that even if harmful effects from exposure to extremely low concentrations of an endocrine disruptor are occurring, teasing out and proving that relationship can be also extremely difficult.
  • Silent Spring, Rachael Carson, Mariner Books; Anv edition (October 22, 2002), ISBN-13: 978-061824906.
    Amazon.com Review: Silent Spring, released in 1962, offered the first shattering look at widespread ecological degradation and touched off an environmental awareness that still exists. Rachel Carson's book focused on the poisons from insecticides, weed killers, and other common products as well as the use of sprays in agriculture, a practice that led to dangerous chemicals to the food source. Carson argued that those chemicals were more dangerous than radiation and that for the first time in history, humans were exposed to chemicals that stayed in their systems from birth to death. Presented with thorough documentation, the book opened more than a few eyes about the dangers of the modern world and stands today as a landmark work.
  • Shock or Chlorinate a Well, When, How-to - Procedure for Shocking a Well to (temporarily or maybe longer) "Correct" Bacterial Contamination
  • US EPA: list of drinking water contaminants: see http://www.epa.gov/safewater/contaminants/index.html
  • UV light: This patent application for UV light sterilization www.patentstorm.us/patents/6565803.html Lists good references on water purification for Giardia et als
  • Water Requirements, Home & Outdoor Living - how much water do people use, how much water do people need?
  • Water Tests & Fees example water test fee schedule
  • Water Testing: background comments on classes of water contaminants, & links to home buyer advice about water testing, drinking
  • Water Treatment for Contamination, Hardness, Odors, Sediment, Etc: choices of systems, recommendations

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson DunlopThe Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.

    Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.
  • ...

HOME ABOUT CONTACT COPYING DESCRIPTION POLICIES PRINTING PRIVACY © 2013 Copyright InspectAPedia.com