Book review of Best Practices Guide to Residential Construction by Steven Bliss

The best practices in residential building construction, tips, tricks, procedures which make the difference between an average or even a problem building and a good building which works well and is a pleasure to occupy, are collected and described in Steve Bliss's book which is reviewed and described here.

This article includes excerpts or adaptations from Best Practices Guide to Residential Construction, by Steven Bliss, courtesy of Wiley & Sons. This article and this website both include excerpts or adaptations from Best Practices Guide to Residential Construction, by Steven Bliss, courtesy of Wiley & Sons.

We also provide a MASTER INDEX to this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need.

Best Practices Guide to Residential Building Construction - Book Review

Book review by Daniel Friedman

Bernie Campbalik used to make a sucking noise through his teeth when he saw one of us do something sloppy on the jobsite or in his carpentry class. Bernie knew a lot about good construction practices, and he regularly pointed out that the foul-ups were often in the details.

Mistakes or omissions led to trouble down the road. We were to avoid such goofs by recognizing them and fixing them on the job. But beyond that sucking noise that we heard a bit more than we wanted to, we remember Bernie's description of his own first days working as a carpenter's assistant.

"The foreman would choose an 18' 2x10, after eying several for straightness, cup, and bow. Then he would disappear around the corner of the building where we were working. He'd return in a few minutes with a pattern rafter and would hand it to me. 'Here, ...' he'd growl as he handed it over, 'dig into that pile over there and cut us 23 more like these.'"

The foreman didn't want Bernie to know how to layout a birds' mouth cut or plumb cut. That little extra knowledge was what he figured was his edge, the data that assured his job as site foreman.

And that has been a problem in construction. While most people who build do so out of a real love of the work, there is a tradition of "not sharing" the how-to details that make the difference between "good enough" and "good work." Unlike his foreman, Bernie actually wanted us to know how to do it right. Not because he particularly liked us, but because he loved the work and wanted that to be right.

Steve Bliss, with a combination of real-world on-the-job construction experience and a long career as a writer and editor for the Journal of Light Construction , Progressive Builder, and Solar Age has written a new book, Best Practices Guide to Residential Construction, Materials, Finishes, and Details, which is full of details and product choices that make the difference between "good enough" and "good work" - the stuff that all of us who build or have built homes wish we'd known sooner.

Best Practices has a simple organization. It’s easy to find details can help the success of your construction project. Here are a few examples:

  1. Exterior finish: a rain screen wall using Cor-A-Vent or folded insect screen at the bottom of a clapboard siding wall can keep out insects and still permit drainage.

    Text is accompanied by a photo suggesting installing siding over furring over the building sheathing. It's a small detail, one of many, that addresses trapped moisture in buildings - a common source of insect damage, rot, or the current enviro-scare topics.

    Beyond concepts, such as "rain screen," Bliss addresses sheathing wraps (house wrap), flashing membranes, wall flashing, and specific details regarding the installation of common exterior sheathings such as wood siding, wood shingles and shakes, vinyl siding, wood and composite trim.

    To go past theory and good ideas, the chapter also lists product suppliers and their websites or contact information. A product resource list is offered at the end of each chapter.
    Courtesy of J. Wiley & Sons & Steven Bliss, adaptations from and expansion on this chapter are available online at

    EXTERIOR WALL SIDING TRIM & FINISHES -
  2. Roofing: Bliss's eaves details for metal roofing, such as remembering to include the rubber closure strip and to cap it with butyl tape address one of many omissions that at our building inspections we find have led to wind-blown rain or wind damage to the roofing. It's a small detail that makes a big difference.

    Bliss includes details for the common roofing materials and systems such as asphalt shingles, clay, concrete, composite tile, metal roofing, low-slope roofing, and of course he addresses the vexsome specialty of roof ventilation. Courtesy of J. Wiley & Sons & Steven Bliss, adaptations from and expansion on this chapter are available online at

    BEST ROOFING PRACTICES -
  3. Windows and Doors: This huge topic is compressed to window types, materials and construction, energy efficiency, skylights, exterior doors.

    Picking an example almost at random, we came across the warning to avoid storing vinyl windows in a container, such as a trailer, or leaning them against a wall, "... as they can permanently deform."

    It was just this condition that we came across recently at a property, and while we saw the defect, we were at a loss to explain how it happened.
    Courtesy of J. Wiley & Sons & Steven Bliss, adaptations from and expansion on this chapter are available online at

    WINDOWS & DOORS -

    BEST PRACTICES GUIDE: WINDOWS & DOORS
  4. Decks and Porches: This chapter takes a look at framing and decking material choices, fasteners, construction details, and the notorious problem of rooftop decks, as well as covered/screened porches and deck finishes.

    After seeing a few terrifying deck collapses, both during and after construction (luckily not at our job sites), we were happy to see Mr. Bliss's details about fastenings and connections, especially at post to beam and post to pier points.

    Bliss also offers some simple details for creation of and sealing at a deck to house-wall gap, one of the most-common leak and rot points we find on buildings where these details are omitted.

    Courtesy of J. Wiley & Sons & Steven Bliss, adaptations from and expansion on this chapter are available online at

    DECK & PORCH CONSTRUCTION

    DECK CONSTRUCTION BEST PRACTICES

    Update - 2010: also see this separate new volume dedicated to best practices in deck and porch construction:

    DECKS and PORCHES , the JLC Guide to, Best Practices for Outdoor Spaces
    , [book for sale at Amazon] Steve Bliss (Editor), The Journal of Light Construction, Williston VT, 2010 ISBN 10: 1-928580-42-4, ISBN 13: 978-1-928580-42-3, available from Amazon.com
  5. Interior Finish: Drywall, various flooring types (wood, vinyl, the currently-popular laminate, carpets), trim, doors, stairs, sound, lighting are surveyed for the Achilles heel and remedy, and Steve includes his recommendations among these choices.

    Environmentally concerned clients will appreciate having some alternatives to vinyl and carpeting and plastic laminates, such as the cork flooring described in this chapter.

    Courtesy of J. Wiley & Sons & Steven Bliss, adaptations from and expansion on this chapter are available online at

    INTERIORS FINISHES, BEST PRACTICES -
  6. Kitchen and Bath: this chapter spends time on design basics - an area that counts for kitchens and baths as anyone who's lived with a thoughtless layout can testify.

    The author offers helpful tables of materials choices (such as flooring) with cost, suitability for radiant heat, pros, cons, and recommendations for each. Courtesy of J. Wiley & Sons & Steven Bliss, adaptations from and expansion on this chapter are available online at

    BATH & KITCHEN DESIGN GUIDE -
  7. Indoor Air quality: It will be interesting to builders to review Bliss's perspective on IAQ, as this topic is much in the public eye, or we should say lung and mind.

    We like that the author stops at a succinct outline of the possible concerns and moves to some clear, basic advice about an overall strategy (about problem particles or gases: "keep it out, vent it out, dilute it, filter it out"), and goes on to offer some opinions about the various methods people are using to improve residential indoor air quality.

    Courtesy of J. Wiley & Sons & Steven Bliss, adaptations from and expansion on this chapter are available online courtesy of J. Wiley & Sons & Steven Bliss.

    This is a rather large topic to tackle in a single chapter, so don't look for an encyclopedic review here. A complete list of indoor air quality topics covered can be seen
    at INDOOR AIR QUALITY IMPROVEMENT GUIDE.

    Of particular use we liked Bliss's
    INDOOR AIR QUALITY IMPROVEMENT, KEY STEPS
    and
    also VENTILATION, WHOLE HOUSE STRATEGIES and his table comparing the pros, cons, controls, cost, and his recommendations for various ventilation methods.

    Also see INDOOR AIR HAZARDS TABLE
    and
    see NDOOR COMBUSTION PRODUCTS & IAQ

    As the author points out, (in our words not his), even the most brilliant and expensive design isn't worth much if it's not used by the building occupants. He suggests "More important than the precise number of cubic feet per minute, however, is a well-designed system that is quite, reliable, and low-maintenance, ensuring it will actually be used."

    Precisely. Combine the real-world philosophy just stated, with a table of the characteristics, appropriateness of use, and cost of venting alternatives, and you have some good design details that can make a difference in the health and quality of life of the occupants of the home.

I like this book and we recommend it. I'm lucky - I didn't have to pay for it. Mr. Bliss sent us a review copy, probably knowing that we hold him in high regard, but probably also slightly worried by knowing that we won't pull any punches on a review.

Summary:

Best Practices Guide to Residential Construction well worth having, and it makes a good dent in the "secret pattern rafter layout" problem we mentioned above, by passing on many "best practice" details for residential construction. This website includes a number of articles and article series using excerpts or adaptations from Best Practices Guide to Residential Construction, by Steven Bliss, courtesy of Wiley & Sons.

To collect and pass on all of them would produce more pages than the Harvard Classics, and more books than Google has indexed (so far). The length of this book, 308 pages including a useful index, gives space for a well-worth-having collection of helpful details beyond the usual arm-waving that pollutes most professions and contaminates ours too.

The book's strengths are the perspective and choice of details selected by a writer who has spent a lifetime of hands-on building, writing about, and finally editing about good construction practices.

Give Best Practices Guide to Residential Construction by Steven Bliss to your builder buddy and if someone doesn't give you a copy, buy your own. ISBN-10: 0-471-64836-1 (cloth) or ISBN-13: 978-0-471-64836-9, John Wiley & Sons,

( http://www.wiley.com/WileyCDA/WileyTitle/productCd-0471648361.html) 2005.

...


Continue reading at Book Reviews - InspectAPedia or select a topic from closely-related articles below, or see our complete INDEX to RELATED ARTICLES below.

Or see InspectAPedia ® BOOKSTORE

Or see these

Book & Article Reviews

Suggested citation for this web page

BEST PRACTICES GUIDE TO RESIDENTIAL CONSTRUCTION at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

INDEX to RELATED ARTICLES: ARTICLE INDEX to BUILDING STRUCTURES

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia


...

Ask a Question or Search InspectApedia

Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

HTML Comment Box is loading comments...

Technical Reviewers & References

Click to Show or Hide Citations & References

Publisher's Google+ Page by Daniel Friedman