InspectAPedia ® Home

ENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY

ACOUSTICAL SEALANT CHOICES
AGE of a BUILDING - how to determine
AIR BYPASS LEAKS
AIR LEAK DETECTION TOOLS
AIR LEAK MINIMIZATION
AIR LEAK SEALING PROCEDURE
AIR POLLUTANTS, COMMON INDOOR
ALLERGENS in BUILDINGS, RECOGNIZING
ANIMAL ALLERGENS / PET DANDER
APPLIANCE EFFICIENCY RATINGS
ARCHITECTURE & BUILDING COMPONENT ID
ASBESTOS CEILING TILES, Asbestos-Containing
ASBESTOS CEMENT ROOFING
ASBESTOS CEMENT SIDING
ASBESTOS DUCTS, HVAC
ASBESTOS FLOORING HAZARD REDUCTION
ASBESTOS-FREE INSULATION MATERIALS
ASBESTOS IDENTIFICATION IN buildings
ASBESTOS FLOORING REMOVAL GUIDE
ASBESTOS LIST of PRODUCTS
ASBESTOS MATERIAL REGULATIONS
ASBESTOS MATERIAL REGULATIONS Update
ASBESTOS MATERIAL REGULATIONS, OSHA
ASBESTOS PHOTO GUIDE to Materials
ASBESTOS REMOVAL, Amateur, Incomplete
Asbestos Removal, Certification
ASBESTOS REMOVAL, Wetting Guidelines
ASBESTOS RISK ASSESSMENT
Asbestos Under the Microscope
ATTIC LEAKS, CONDENSATION & MOLD
ATTIC VENTILATION

BASEMENT CEILING VAPOR BARRIER
BASEMENT HEAT LOSS
BASEMENT LEAKS, INSPECT FOR
BASEMENT WATERPROOFING
BATH & KITCHEN DESIGN GUIDE
BATHROOM VENTILATION
BEST CONSTRUCTION PRACTICES GUIDE
BLOWER DOORS & AIR INFILTRATION
BLOWER FAN CONTINUOUS OPERATION
BLOWER FAN OPERATION & TESTING
BLOWN-IN INSULATION
BRICK LINED WALLS
BRICK VENEER WALL AIR LEAKS
BRICK VENEER WALL Loose, Bulged
BRICK WALL DRAINAGE WEEP HOLES
BUCKLED FOUNDATIONS due to INSULATION?
BUILDING NOISE DIAGNOSIS & CURE
BUILDING SAFETY HAZARDS GUIDE

CATHEDRAL CEILING INSULATION
CATHEDRAL CEILING VENTILATION
CEILING FINISHES INTERIOR
CEILINGS, DROP or SUSPENDED PANEL
CEILINGS, PLASTER TYPES
CERAMIC TILE FLOOR, WALL
CERAMIC TILE, ASBESTOS in?
CHIMNEY INSPECTION DIAGNOSIS & REPAIR
CHINESE DRYWALL HAZARDS
COMBUSTION AIR for TIGHT buildings
CONDENSING BOILERS/FURNACES DAMAGE
CRAWL SPACES
CONDENSATION or SWEATING PIPES, TANKS
COOLING LOAD REDUCTION by ROOF VENTS

DEHUMIDIFICATION PROBLEMS
DEW POINT CALCULATION for WALLS
DEW POINT TABLE - CONDENSATION POINT GUIDE

EARTHQUAKE DAMAGED FOUNDATIONS
EFFLORESCENCE, Salts & White / Brown Deposits
ELDERLY & VETERANS HOME SAFETY
ELECTRICAL INSPECTION, DIAGNOSIS, REPAIR
ENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY
EXTERIOR WALL SIDING TRIM & FINISHES

FIBERGLASS INSULATION
FIBERGLASS HAZARDS
FIBERGLASS INSULATION MOLD
FLASHING MEMBRANES PEEL & STICK
FLASHING for METAL ROOFS
FLASHING ROOF WALL DETAILS
FLASHING ROOF-WALL SNAFU
FLASHING SIDING DETAILS
FLASHING WALL DETAILS
FLASHING WINDOW DETAILS
FLASHING WOOD ROOF DETAILS
FLAT ROOF MOISTURE & CONDENSATION
FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
FLOOD DAMAGED FOUNDATIONS
FLOOD VENTS & FLOOD PORTS
FLOODS IN buildings-mold
FLOOR & SUBFLOOR MOLD, HIDDEN
FLOOR TILE HISTORY & INGREDIENTS
FLOOR TYPES & DEFECTS
FOUNDATION WATERPROOFING
FRENCH DRAINS
FREEZE-PROOF A BUILDING
FROST HEAVES, FOUNDATION, SLAB

GREENHOUSE DESIGN for SOLAR HEATING

HEAT LOSS in BUILDINGS
HEAT LOSS DETECTION TOOLS
HEAT LOSS INDICATORS
HEAT LOSS PREVENTION PRIORITIES
HEAT LOSS R U & K VALUE CALCULATION
HEAT TAPES & CABLES on Roofs for Ice Dams
HEATING COST SAVINGS METHODS
HOT ROOF DESIGNS: Un-Vented Roof Solutions
HOUSEWRAP AIR & VAPOR BARRIERS
HOUSE DOCTOR, how-to be
HUMIDITY LEVEL TARGET

ICE DAM PREVENTION
Ice Dams: Comparing Two Houses
INDOOR AIR QUALITY & HOUSE TIGHTNESS
INDOOR AIR QUALITY IMPROVEMENT GUIDE
INSULATION CHOICES
INSULATION FACT SHEET- DOE
INSULATION for GREENHOUSE or SOLARIUM
INSULATION IDENTIFICATION GUIDE
INSULATION INSPECTION & IMPROVEMENT
INSULATION LOCATION - WHERE TO PUT IT
INSULATION MOLD
INSULATION R-Values & Properties

LOG HOME GUIDE

MOBILE HOME INSPECTIONS
MOISTURE CONTROL in BUILDINGS
MOLD INFORMATION CENTER

Nanomaterials Hazards
NOISE / SOUND DIAGNOSIS & CURE
NOISE, AIR CONDITIONER COMPRESSOR
NOISE, DUCT VIBRATION DAMPENERS
NOISE CONTROL for HEATING SYSTEMS
NOISE CONTROL for FLOORS
NOISE CONTROL for PLUMBING
NOISE CONTROL for ROOFS
NOISES COMING FROM WATER HEATER

ODORS & SMELLS DIAGNOSIS & CURE

PAINT FALURE, DIAGNOSIS, CURE, PREVENTION
PASCAL CALCULATIONS
PLASTER & BEAVERBOARD & DRYWALL
PLASTER BULGES & PILLOWS
PLASTER LATH, METAL
PLASTER, LOOSE FALL HAZARDS
PLASTER TYPE IDENTIFICATION
PLASTER VENEER Best Practices

RADIANT BARRIERS
RADIANT HEAT
RADIANT HEAT Floor Mistakes to Avoid
RADIANT HEAT TEMPERATURES
RADIANT SLAB FLOORING CHOICES
RADIANT SLAB TUBING & FLUID CHOICES
ROOF VENTILATION SPECIFICATIONS
ROT RESISTANT LUMBER
ROT, TIMBER FRAME
ROT, TIMBER ASSESSMENT

SAFETY HAZARDS & INSPECTIONS
SEARS KIT HOUSES
SINKHOLES, WARNING SIGNS
SINKING BUILDINGS
SLAB CRACK EVALUATION
SOUND CONTROL in buildings
Splits in Structural Wood Beams
STAIN & BIODETERIORATION AGENT CATALOG
STAINS on & in BUILDINGS, CAUSES & CURES
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIN DIAGNOSIS on BUILDING INTERIORS
STAIN DIAGNOSIS on ROOFS
STAIN DIAGNOSIS on STONE
STAINS on INDOOR SURFACES: PHOTO GUIDE
STAIRS, RAILINGS, LANDINGS, RAMPS
STONE CLEANING METHODS
STONE VENEER WALLS
STRAW BALE CONSTRUCTION
STUCCO WAll FAILURES DUE TO WEATHER
STUCCO WALL METHODS & INSTALLATION
STUCCO OVER FOAM INSULATION
STUCCO PAINT FAILURES
STRUCTURAL DAMAGE PROBING
STRUCTURAL WOOD ASSESSMENT
SUMP PUMPS GUIDE
SWEATING (CONDENSATION) on PIPES, TANKS

Thermal Expansion Cracking of Brick
THERMAL EXPANSION of HOT WATER
THERMAL EXPANSION of MATERIALS
THERMAL IMAGING, THERMOGRAPHY
THERMAL IMAGING MOLD SCANS
THERMAL MASS in BUILDINGS
THERMAL TRACKING Indicates Heat Loss

VAPOR BARRIERS & CONDENSATION in BUILDINGS
VENTILATION in BUILDINGS
VINYL CHLORIDE HEALTH INFO
VINYL SIDING
VINYL Siding or PLASTIC Window ODORS
Volatile Organic Compounds VOCs

WALL CONSTRUCTION BARRIER vs CAVITY
WATER ENTRY in buildings
WINDOWS & DOORS
WINTERIZE A BUILDING
WOOD, COAL STOVES & FIREPLACES
WOOD STOVE SAFETY

ZONE DAMPERS
ZONE VALVES

More Information

Congoleum sheet flooring, Life Magazine 1955 Congoleum Nairn Vinyl-Asbestos Floor Tiles & Sheet Flooring Identification Photo Guide
     

  • How to recognize Congoleum Nairn floor tiles & linoleum or resilient sheet flooring that may contain asbestos fibers
    • Old or discontinued Congoleum Nairn floor tile identification photographs
    • Congoleum-Nairn floor tile patterns
    • Asphalt asbestos Congoleum Nairn & Congoleum Nairn vinyl-asbestos floor tile identification and advice 1917 - 1986
    • Congoleum Nairn Vinyl asbestos floor tile identification and handling to minimize asbestos fiber risks
    • Photographs of Congoleum Nairn asbestos containing floor tiles, sheet flooring, linoleum, and resilient floor coverings
  • LINOLEUM & Other Sheet Flooring - separate article
  • Vinyl Asbestos Sheet Flooring - separate article
  • Questions & Answers about identifying Congoleum or Congoleum Nairn flooring materials & their asbestos content
  • References

Click to Show or Hide Related Topics

  • ASBESTOS IDENTIFICATION IN buildings - home
  • ASBESTOS-CONTAINING FLOOR TILE DIMENSIONS
  • ASBESTOS FLOOR TILE IDENTIFICATION
  • ASBESTOS FLOOR TILE PHOTO ID GUIDE - photo guide
  • ASBESTOS FLOOR TILE PRODUCT NAMES
  • ASBESTOS FLOORING HAZARD REDUCTION
  • ASBESTOS FLOORING REMOVAL GUIDE
  • ASBESTOS FLOOR TILE LAB PROCEDURES
  • ASBESTOS REMOVAL, Wetting Guidelines
  • ASBESTOS RISK ASSESSMENT
  • CERAMIC TILE, ASBESTOS in?
  • DUST SAMPLING PROCEDURE
  • FLOOR TILE HISTORY & INGREDIENTS - home
  • FLOORING MATERIALS, Age, Types
  • FLOOR TYPES & DEFECTS - home
  • HOW TO IDENTIFY YOUR FLOOR TILE
  • LINOLEUM & Other Sheet Flooring
  • RESILIENT FLOORING Vinyl or Cork
  • Amitco floor tiles
  • Armstrong Floor Tiles
  • 1951 - 1959 Armstrong Floor Tiles
  • 1960 - 1969 Armstrong Excelon Floor Tiles
  • 1970 - 1972 Armstrong Excelon Floor Tiles,
  • 1973 - Armstrong Asbestos Floor Tiles, Complete
  • 1974 - 1979 Armstrong Floor Tiles, Complete
  • 1980 - 1988 Armstrong Vinyl Asbestos Floor Tile
  • 1989 & Later Armstrong Accoflex Series Flooring Tiles
  • Congoleum-Nairn Floor Tiles, Linoleum
  • Cork Flooring Tiles
  • Ever-Wear Floor Tiles
  • Kentile KenFlex Floor Tiles
  • Manning Mills Flooring
  • MASTIC, CUTBACK ADHESIVE, FLASHING CEMENT ASBESTOS
  • Montgomery Ward Floor Tiles
  • Sears Roebuck Vinyl Asbestos Floor Tiles
  • SELF-ADHESIVE Peel & Stick-on Tiles, Asbestos
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

Congoleum asbestos flooring identification: this article provides a guide to identifying Congoleum-Nairn asphalt-asbestos, vinyl asbestos floor tiles, linoleum, and sheet flooring (resilient flooring) materials that are reported to contain asbestos, or that have been confirmed as containing asbestos in asbestos fiber or asbestos powder-filler form.

Green links show where you are. © Copyright 2013 InspectAPedia.com, All Rights Reserved. Author Daniel Friedman.

Styles, & Pictures of Congoleum-Nairn Vinyl-Asbestos Floor Tiles & Congoleum Linoleum Sheet Flooring: Resilient Floors

Asbestos is safe and legal to remain in homes or public buildings as long as the asbestos materials are in good condition and the asbestos can not be released into the air.

Congoleum Gold Seal Linoleum Flooring, Life Mag Ad 1955Congoleum Nairn, was established in 1886, and presently headquartered in Mercerville, NJ, U.S., produced resilient sheet flooring, vinyl asbestos floor tiles in patterns such as their Congoleum-Nairn Romanaire pattern

Details about the history of Congoleum Nairn flooring are at Congoleum Flooring History and at FLOOR TILE HISTORY & INGREDIENTS.

Additional Images of Congoleum linoleum sheet flooring products are at LINOLEUM & Other Sheet Flooring.

Sequin Pattern for Congoleum resilient flooring is shown at left.

Watch out: the backing on some of these vinyl flooring or linoleum products may also contain asbestos.

For a detailed photo guide to all brands of vinyl-asbestos floor tile & resilient flooring patterns, sizes, and years of manufacture, see ASBESTOS FLOOR TILE PHOTO ID GUIDE. Readers should see ASBESTOS FLOORING HAZARD REDUCTION and also see FLOOR TILE HISTORY & INGREDIENTS for a discussion of the ingredients and production of asbestos-containing flooring. And see ASBESTOS FLOOR TILE IDENTIFICATION for detailed advice on handling and identifying vinyl-asbestos floor tiles or flooring products that probably do or don't contain asbestos. For a strategy for collecting building dust samples, when, where, how many samples to collect, see DUST SAMPLING PROCEDURE.


Congloeum linoleum Sequin pattern (C) D Friedman M Barnicle

Congoleum Vinylbest vinyl asbestos floor tiles were produced in the 1950s along with Congoleum Gold Seal inlaid linoleum flooring shown at above left from a Life magazine advertisement, and the Congoleum sheet linoleum shown in a Florida Home (left) provided a scattershot or color fleck pattern.

The Congoleum linoleum photograph (left) of Congoleum sheet flooring installed in a 1949 Tampa Florida home is provided courtesy of M.B.

M.B. placed a U.S. quarter on the flooring to provide a pattern size scale reference. [Click image for a larger view]. [We think the flooring itself may date from the 1960's.]

Other Congoleum products included Vinylfloor, Vinyltop (countertops), Congoleum, CongoWall, Ranchtile, Cork tile, Linoleum tile, Vinyl tile, Rubber tile, and Asphalt tile marketed under the Congoleum Gold Seal trademark.

Congoleum Nairn tile flooring and resilient flooring or linoleum flooring photos wanted - CONTACT US to contribute to InspectAPedia.com

Below we show three more interesting Congoleum Narin sheet flooring designs from the mid 1950's (excerpted from Life Magazine advertisements).

Don't Mix Up Congoleum Nairn Resilient Flooring with Armstrong Floors

Armstrong sheet flooring (C) InspectAPedia.com

This photograph of sheet flooring was identified by a reader in a 1964 home. She found remnants in the bottom of a kitchen cabinet on which was imprinted "Armstrong".

While the reader referred to this as "Armstrong Congoleum sheet flooring", Armstrong and Congoleum are separate individual companies.

This is identified as an Armstrong resilient flooring product.

Congoleum Sheet Flooring Products Resembling Individual Floor Tiles

Congoleum sheet flooring, Life Magazine 1955 (C) D Friedman D Grudzinski Congoleum sheet flooring, Life Magazine 1955

At above left is a continuous resilient Congoleum Nairn sheet flooring product that was colored to resemble individual floor tiles in red, black,and white The Congoleum-Nairn company advertised that this approach was less costly and quicker to install than tiles, and permitted better control over tile color consistency.

Above right our photograph excerpted from another 1950's flooring advertisement shows a Congoleum sheet floor used in a kitchen and dining area.

Congoleum Gold Seal Rugs and Nairn Linoleum

Congoleum sheet flooring, Life Magazine 1955 (C) D Friedman D Grudzinski

 

This Congoleum flooring advertisement, also from the 1950's, demonstrated use of sheet flooring to provide a border and carpet image in a bedroom.

Congoleum Gold Seal Rugs along with Nairn Linoleum were marketed from the 1920's into the 1950's when Congoleum-Nairn was producing 12-foot wide sheet vinyl-based flooring.

We discuss the history and manufacture of asphalt-asbestos floor tiles in our Age of House articles at Flooring Materials.

We discuss the inspection, diagnosis, and repair of various flooring products at FLOOR TYPES & DEFECTS.Also see ASBESTOS DUCTS, HVAC a field identification guide to visual detection of asbestos in and on heating and cooling system ducts and flue vents

Also see Micro-Photographs of Dust from the World Trade Center collapse following the 9/11/01 attack. Links to U.S. government and other authoritative research and advice are included.


Frequently Asked Questions (FAQs) about how to identify vinyl asbestos floor tiles, linoleum, or sheet flooring made by Congoleum

...

Ask a Question or Search InspectApedia

Questions & answers or comments about asbestos hazards in older Congoleum - Nairn flooring & sheet flooring products. .

Ask a Question or Enter Search Terms in the InspectApedia search box just below.

Technical Reviewers & References

Related Topics, found near the top of this page suggest articles closely related to this one.

  • Armstrong ® Residential Flooring - Website 05/15/2010 http://www.armstrong.com/ lists current flooring products provided by the Armstrong Corporation, including Armstrong's current vinyl floor tile products at http://www.armstrong.com/flooring/products/vinyl-floors
  • Armstrong Corporation, Corporate History - http://www.armstrong.com/corporate/corporate-history.html - Web Search 05/19/2010
  • Armstrong vinyl asbestos floor tiles: photos of asbestos-vinyl floor tiles as catalog pages (PDF form) are at www.asbestosresource.com/asbestos/tile.html
  • Accoflex 2005 series semi-flexible vinyl tile Wonder flooring product description; Armstrong's Accoflex is a vinyl composition floor tile. WonderFlooring, Private Bag X02, Fordsburg 2033, Telephone: 011 298 8100, Fax: 011 836 4450, National Call Centere: 0860-29-80-80, Email: info@wonderflooring.com & marketing@wonfloor.com/ [2nd is a defective email address]
    Web search 01/29/2011, original source: http://www.wonderflooring.com/accoflex/accoflextech2.pdf
    Reference: Armstrong Flooring: Accotile, Accoflex & Coke Tile. Publication 333, Armstrong Flooring.
    Note on use of the "Accoflex" name:
    In addition to Accoflex flooring produced by Armstrong, Accoflex® is also a U.S. registered trademark used for Insulation Jackets For Industrial Pipes, Tanks and Conduits Including Flexible and Rigid Insulation In the Form of Foamed Synthetic Material Sheeting, owned by Armacell Enterprise Gmbh, Armstrong World Industries, Inc, also distributed in the U.K., Australia, & New Zealand, also in Indonesia. Armacell Australia Pty Ltd, a producer of engineered foams, (http://www.armacell.com/) was founded officially in August 2000 when the then Armstrong Insulation Products (Australia) became a separate legal entity from Armstrong World Industries group.
  • "Asbestos in your home or at work," Forsyth County Environmental Affairs Department, Winston-Salem NC 12/08
  • "Asbestos Floor Tile Removal", the University of Minnesota's advice on removing VAT (vinyl asbestos or asphalt asbestos floor tile) can be read in detail at www.health.state.mn.us/divs/eh/asbestos/floortile/index.html
  • Copy on file as - /hazmat/Asbestos_in_Your_Home_US_EPA.pdf - Asbestos in Your Home - U.S. EPA, Exposure Evaluation Division, Office of Toxic Substances, Office of Pesticides and Toxic Substances, U.S. Environmental Protection Agency, Washington,D.C. 20460
  • Resilient Floor Covering Institute, 1030 15th St. NW, suite 350, Washington D.C.
  • Book Recommendations for Asphalt & Vinyl-Asbestos Floor Tile Identification:
    • Inspiring Interiors from Armstrong 1950s from Armstrong, [Paperback], Schiffer Publishing (March 1998), ISBN-10: 0764304585, ISBN-13: 978-0764304583 (Available from Amazon)
    • Interior Solutions from Armstrong the 1960s from Armstrong, [Paperback], Schiffer Publishing (March 1999), ISBN-10: 0764307002, ISBN-13: 978-0764307003 (Available from Amazon)
    • Mechanix Illustrated How-to-do-it Encyclopedia Vol 2. -1961
  • Asbestos products and their history and use in various building materials such as asphalt and vinyl flooring includes discussion which draws on Asbestos, Its Industrial Applications, D.V. Rosato, engineering consultant, Newton, MA, Reinhold Publishing, 1959 Library of Congress Catalog Card No.: 59-12535 (out of print).
  • Congoleum Corporation, "Company History", Congoleum Corporation, Department C, P.O. Box 3127, Mercerville, NJ 08619-0127 1-609-584-3601, web-search 03/14/2011, original source: http://www.congoleum.com/history.html
  • David Grudzinski, Advantage Home Inspections, is a professional home inspector in Cranston, RI. 02910. He can be reached at 401-935-6547, fax- 401-490-0607 or by email to contact/us@advantagehomeinspections.us 04/26/2009
  • EPA Guidance for Controlling Asbestos-Containing Materials in buildings, NIAST, National Institute on Abatement Sciences & Technology, [republishing EPA public documents] 1985 ed., Exposure Evaluation Division, Office of Toxic Substances, Office of Pesticides and Toxic Substances, U.S. Environmental Protection Agency, Washington,D.C. 20460
  • EVER WEAR TILE CO is currently (2009) in the Terrazzo, Tile, Marble, and Mosaic Work industry in Fallon, NV. 775) 423-6221. [We do not know the company history nor whether there is an association with EverWear vinyl asbestos floor tiles discussed in this article.]
  • Kentile KenFlex flooring photographs: Flickr web search 5/15/2010 - see original material and other asbestos product photos
  • "Plastic Flooring Spreads Through the House", Jackson Hand, Guide to Home-Improvement Materials, Popular Science, April 1969, p. 154-158
  • Thomas Hauswirth, Managing Member of Beacon Fine Home Inspections, LLC and (in 2007) Vice President, Connecticut Association of Home Inspectors Ph. 860-526-3355 Fax 860-526-2942 beaconinspections@sbcglobal.net 06/07: thanks for photographs of transite asbestos heating ducts
  • Gary Randolph, Ounce of Prevention Home Inspection, LLC Buffalo, NY, for attentive reading and editing suggestions. Mr. Randolph can be reached in Buffalo, NY, at (716) 636-3865 or email: gary@ouncehome.com 3/07
  • Thanks to reader Matt Abel, Design Services Department, Strongwood Log Home Company, 711 Shadow Road, Waupaca WI 54981, Office (715) 258-4818, Toll Free (866) 258-4818, www.gostrongwood.com "Begin your journey home.." for vinyl asbestos floor photos, October 2010.
  • Thanks to reader Meryl Silvers for hexagonal floor tile photos showing a possible Kentile product that contained asbestos. October 2010.
  • Thanks to reader N.H. for providing a photo of 1970's era vinyl asbestos floor tile that we identify as most likely Armstrong Solarian Devonport white.
  • M.B. provided photographs of Congoleum linoleum flooring from a 1960's Tampa Florida home.
  • June 1997 - Window Putty - OSHA case cites contractor for asbestos exposure during removal of window putty http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=NEWS_RELEASES&p_id=1091
  • Asbestos Identification and Testing References
    • Asbestos Identification, Walter C.McCrone, McCrone Research Institute, Chicago, IL.1987 ISBN 0-904962-11-3. Dr. McCrone literally "wrote the book" on asbestos identification procedures which formed the basis for current work by asbestos identification laboratories.
    • Stanton, .F., et al., National Bureau of Standards Special Publication 506: 143-151
    • Pott, F., Staub-Reinhalf Luft 38, 486-490 (1978) cited by McCrone
  • Asbestos in Your Home U.S. EPA, Exposure Evaluation Division, Office of Toxic Substances, Office of Pesticides and Toxic Substances, U.S. Environmental Protection Agency, Washington,D.C. 20460
  • Asbestos products and their history and use in various building materials such as asphalt and vinyl flooring includes discussion which draws on Asbestos, Its Industrial Applications, D.V. Rosato, engineering consultant, Newton, MA, Reinhold Publishing, 1959 Library of Congress Catalog Card No.: 59-12535 (out of print, text and images available at InspectAPedia.com).
  • "Handling Asbestos-Containing roofing material - an update", Carl Good, NRCA Associate Executive Director, Professional Roofing, February 1992, p. 38-43
  • EPA Guidance for Controlling Asbestos-Containing Materials in buildings, NIAST, National Institute on Abatement Sciences & Technology, [republishing EPA public documents] 1985 ed., Exposure Evaluation Division, Office of Toxic Substances, Office of Pesticides and Toxic Substances, U.S. Environmental Protection Agency, Washington,D.C. 20460
  • ...

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson DunlopThe Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.

    Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.

  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
    Building inspection education & report writing systems from Carson, Dunlop & Associates Ltd