InspectAPedia.com InspectAPedia®
Google
InspectAPedia
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US



Mobile Phone/PDA website viewMobile View
SEPTIC SYSTEM INSPECT DIAGNOSE REPAIR

SEPTIC AUTHORITIES, DESIGN REGS
SEPTIC BACKUP REPAIR
SEPTIC BOOK, FREE ONLINE
SEPTIC BOOKSTORE
SEPTIC INFO ARTICLES
  Septic Guide for Home Buyers or Owners
  Septic or Sewer Connection?
  Septic System Design
  Septic System Designs Master List
  Septic Inspection Testing
  Septic Maintenance Repair
  Septic Component & Product Suppliers
  Septic Videos
SEPTIC SYSTEM, HOME BUYERS GUIDE
SEPTIC SYSTEMS - INTRODUCTION
SEPTIC SYSTEM SAFETY WARNINGS
SEPTIC SYSTEM DESIGN BASICS
  DRYWELL DESIGN & USES
  FILTERS SEPTIC & GREYWATER
  SEEPAGE PITS
  SEPTIC CLEARANCES
  SEPTIC SOIL & PERC TESTS
  SEPTIC TANK SIZE
  SEPTIC DRAINFIELD SIZE
  SEPTIC DRAINFIELD SHAPE
  SEPTIC TANK PUMPING FREQUENCY
  SEPTIC TANK PUMPING PROCEDURE
  SEPTIC SYSTEM PUMPS
  SEPTIC TREATMENTS & CHEMICALS

SEPTIC SYSTEM DESIGN ALTERNATIVES
  ALTERNATIVE SEPTIC DESIGNERS
  ALTERNATIVE SEPTIC PRODUCTS
    AEROBIC Septic System ATU SUPPLIERS
    Alternative Septic System Product Suppliers
    BIOGAS PRODUCTION & USE
    Septic System Filters
    Gravelless Leach Field Systems
    Septic Effluent Distribution Products
    Toilets & Alternative Toilet Types
    Other Septic Wastewater Treatment Products
    Directory of Septic Suppliers
  AEROBIC SEPTIC SYSTEMS
  ALTERNATING BED SEPTIC SYSTEMS
  BIOGAS PRODUCTION & USE
  CESSPOOLS
  DISINFECTION SYSTEMS, SEPTIC EFFLUENT
  DRYWELL DESIGN & USES
  EVAPORATION-TRANSPIRATION SEPTIC SYSTEMS
  FILTERS SEPTIC & GREYWATER
  FIXED-FILM PROCESS SEPTIC SYSTEMS
  GRAVELLESS SEPTIC SYSTEMS
  GRAVITY/SIPHON DOSING SYSTEMS
  GREYWATER SYSTEMS
  MEDIA FILTER SEPTIC SYSTEMS
  MOUND SEPTIC SYSTEMS
  OUTHOUSES & LATRINES
  PEAT FILTER SEPTICS
  PRESSURE DOSING SEPTIC SYSTEMS
  RAISED BED SEPTIC SYSTEMS
  SAND BED SEPTIC SYSTEMS
  SEEPAGE PITS
  SEPTIC SYSTEM PUMPS
  SEQUENCING BATCH SEPTIC SYSTEMS
  SEWAGE TREATMENT SYSTEMS
  STEEP SLOPE SEPTIC DESIGNS
  TOILET ALTERNATIVES
  TOILET TYPES
  Toilet Types, Flush Methods
  TOILETS, DON'T FLUSH LIST
  TRAPS on PLUMBING FIXTURES
  VEGETATED SUBMERGED SEPTIC BEDS
  Wastewater Treatment Levels
  Wastewater Dispersal Methods
  WETLAND SEPTIC SYSTEMS
Also see
    Plumbers & Septic Repairs
    Septic Tank Suppliers

SEPTIC INSPECTION & TEST GUIDE
SEPTIC SYSTEM INSPECTION LEVELS

SEPTIC SYSTEM DEFINITIONS
SEPTIC FAILURE LAWSUIT
SEPTIC REFERENCES
SEPTIC AUTHORITIES, DESIGN REGS
SEPTIC BOOKSTORE
SEPTIC BIOMATS
SEPTIC CARE INSTRUCTIONS
SEPTIC CLEARANCE DISTANCES
SEPTIC CODES & REFERENCES
SEPTIC CONSULTANTS
SEPTIC DYE TEST PROCEDURE

SEPTIC INSPECTION & TEST GUIDE
SEPTIC SYSTEM INSPECTION LEVELS

SEPTIC SYSTEM DEFINITIONS
SEPTIC SYSTEM DESIGN MANUAL - Online

SEPTIC SYSTEM DESIGN ALTERNATIVES

SEWAGE & SEPTIC CONTAMINANTS
SEWAGE BACKUP, WHAT TO DO
SEWAGE BACKUP TEST & CLEANUP
SEWAGE BACKUP PREVENTION
SEWAGE CONTAMINATION in buildings
SEWAGE CONTAMINANTS in FRUIT / VEGETABLES
SEWAGE EJECTOR / GRINDER PUMPS
SEWAGE LEVELS in SEPTIC TANKS
SEWAGE NITROGEN CONTAMINANTS
SEWAGE PATHOGENS in SEPTIC SLUDGE
SEWAGE PUMPS
SEWER BACKUP PREVENTION
SEWER GAS ODORS
SEWER LINE REPLACEMENT

SINKHOLES, WARNING SIGNS
SMELL PATCH TEST to Track Down Odors
SOAKAWAY BED FAILURE DIAGNOSIS
SULPHUR & SEWER GAS SMELL SOURCES
SUMP PUMPS

TOILETS, INSPECT, INSTALL, REPAIR
TOILET ALTERNATIVES
TOILET FLUSHOMETER VALVES
TOILET INSTALLATION PROCEDURE
TOILET OVERFLOW EMERGENCY
TOILET PLUGS, SEWER BACKUP
TOILET REPAIR GUIDE
TOILET TISSUE CHOICES
TOILET TYPES
Toilet Types, Flush Methods
TOILETS, DON'T FLUSH LIST
TRAPS on PLUMBING FIXTURES
TREATMENTS & CHEMICALS, SEPTIC

VIDEO GUIDES: Septic Videos

WASHING MACHINES & SEPTIC SYSTEMS
WATER SOFTENERS & CONDITIONERS
WATER SUPPLY & DRAIN PIPING
  CLOGGED DRAIN DIAGNOSIS & REPAIR
WASTEWATER TREATMENT BASICS
WATER, WELLS, WATER TANKS: TESTING GUIDE
WATER PURIFIERS
WATER QUALITY TESTS, CONTAMINANTS, TREATMENT
WATER QUANTITY IMPROVEMENT
WATER QUANTITY USAGE GUIDE
WATER, WELLS, WATER TANKS: TESTING GUIDE
WETLAND SEPTIC SYSTEMS
WINTERIZE A BUILDING

More Information

SKETCH of a typical aerobic treatment unit tank, aerator, chamberDirectory of Alternative Design Septic Product Suppliers
InspectAPedia®  -      

  • Aerobic Septic System Products Directory List
  • Alternative Septic System Product Suppliers List
  • Filters, Septic Filters & Wastewater Treatment Systems Using Filtration Methods Products Directory
  • Gravelless Leach Field Septic Systems Products Directory List
  • Septic Effluent Distribution Products Directory List
  • Toilets, Composting Toilets, Biological Toilets, No-water/Low water toilets, Waterless toilets, Chemical Toilets, Incinerating Toilets and related products list
  • Other Septic Wastewater Treatment Products List
  • Plumbers & Septic Repair Companies List
  • Septic Tanks - sources and types of septic tanks for new or replacement use
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers nor with topics or services discussed at this website.

Here is our Directory List of Alternative Septic System Products, for wet sites, steep sites, rocky sites, limited space, and other difficult site conditions. Readers should also see our Septic Component & Product Suppliers for basic septic system compnents like septic tanks and pumps. This chapter provides information about alternative septic system products such as aerobic septic systems, septic filters, gravelless septic systems and other products for onsite, wastewater management. Alternative onsite wastewater disposal system products can reduce the soil absorption area or leach field size requirement substantially and can in fact in some cases reduce the needed area to zero.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

ALTERNATIVE SEPTIC PRODUCTS - Alternative Onsite Waste Disposal (Septic System) Materials & Products

Some of these alternative septic system products can produce effluent which is more sanitary than the groundwater in the area where the effluent is being discharged. For problem sites where space or soil conditions make it difficult to install a conventional leach field these designs are very important alternatives. Qualified product or service providers may be listed at this website at no fee.

AEROBIC Septic System ATU SUPPLIERS

A list of suppliers of aerobic septic system equipment is maintained at Aerobic Treatment Unit Suppliers for a list of aerobic septic system treatment unit suppliers. Aerobic Septic Systems - Aerobic Treatment Units or ATUs are discussed in detail at AEROBIC SEPTIC SYSTEMS A Design Alternative for Difficult Sites

Alternative Septic System Product Suppliers

  • ALTERNATIVE SEPTIC PRODUCTS provides at Directory of Alternative Design Septic Product Suppliers
  • Advanced Septic Treatment Systems, Inc, Sedro Woolley, WA Tel: 360-856-0550 , email: SalesTeam-at-trd1000.com - TRD-1000 aerobic treatment system unit. Quoting:
    The TRD-1000 revolutionized the concept of a Sequencing Batch Reactor (SBR) for small flow wastewater treatment installations.
    The drop-in packaged treatment plant is easily installed in less than a day and produces a quality effulent that exceeds NSF Treatment Standard 40.Certified in 1998 by NSF International to meet all requirements of the Standard 40 testing protocol, ten years later (2008) the TRD-1000 was retested and certified to Standard 40. The system continues to surpass NSF Standard 40 and all other ATU's in it's effulent quality.
  • American Wastewater Systems aerobic treatment units
  • BioNest biological filtration for wastewater treatment using a microbial culture fixed to a non-biodegradable media. Underground system.
  • Bord Na Mona Environmental peat bio-filtration systems
  • Cajunaire Wastewater Treatment Systems, 500 gpd to 1000 gpd ATU systems, aerobic sprinkler systems, wastewater pumps, wastewater disinfection systems including chlorination and UV light: from H. E. McGrew, Louisiana
  • Clivus Multrum wastewater treatment/disposal systems include their composting toilet and greywater irrigation systems
  • Consolidated Treatment Systems including suspended media treatment systems, aerobic wastewater treatment systems, and reactor vessel wastewater treatment systems.
  • Delta Environmental low pressure sewer systems (for example to pump and treat wastewater up and away from lakefront properties) offers grinder pump systems and related products
  • Ecological Tanks manufactures four-chamber (Pretreatment, Aeration, Clarifier, Pumping) Aqua Aire Aerobic Wastewater Treatment Units and Aqua Safe Aerobic Treatment Plants in both fiberglass and concrete to NSF 40 Standards
  • Environment One grinder pump sewer systems for difficult sites and capable of pumping against high head pressures.
  • Hoot Aerobic Systems including ATUs, blowers, controls, disinfection systems, and wastewater treatment monitoring systems. Louisiana.
  • Malibu Water Resources provides the Koenders Aerobic Aerator along with a diffuser.
  • MicroSepTec offers the "EnviroServer" which, depending on the system size, treats 600 to 2500 gpd. of sewage. This is a a packaged wastewater treatment system comprised of a "hybrid fixed film-suspended growth extended aeration wastewater treatment system with a two stage biological process to optimize denitrification"
    Check out their animated explanation of how this system works.
  • Norweco: Singulair aerobic systems, Modulair packaged wastewater treatment systems, total nitrogen treatment systems, wastewater treatment controls, wastewater and graywater filter systems,effluent pumps, pumping stations, dechlorination tablets, disinfection systems, other products
  • Orenco Systems: effluent pumps, advanced treatment units, sand filters, recirculating sand filters, shallow gravelless systems, wastewater treatment monitoring systems
  • Piranha septic systems use an aerobic bacterial generator placed directly into the septic tank and a patented bacterial culture. [I question the claim by this company that septic tank pumping is eliminated.]
  • Pro Flo Areobic septic systems says that their system is "capable of turning regular household sewage into a clear odorless liquid within 24 hours"
  • South Texas Environmental sells various types of septic pumps including aerobic air pumps for aerobic septic systems, other pumps, aerators, diffusers, control panels, and compressors.
  • Pond Expo Alita brand aeration pumps for ponds and other aeration systems
  • NSF International, The Public Health and Safety Company, a not-for-profit, non-governmental organization, maintains a list of wastewater treatment unit manufacturers and may offer other products and advice for ATU's and other onsite wastewater treatment methods.
  • Tafgard soil based wastewater treatment systems - developed in Japan by Taisei Kogyo Co., Ltd., this system uses a combination of a five-chamber waste treating septic tank designed by Taisei, effluent disposed-of by an evaporation-transpiration system through aerated soil (effluent spread horizontally and upwards from distribution piping).
  • Listing submissions welcome, there is no listing fee. InspectAPedia.com - Directory Listing & Link Exchange Instructions. Add your listing & support InspectAPedia.com by exchanging links - no listing fee & no conflicts of interest.

Septic Effluent Distribution Products

  • Geoflow subsurface drip systems offer uniform effluent distribution and piping clog resistance for placing clarified effluent into an absorption system.
  • Tafgard soil based wastewater treatment systems - developed in Japan by Taisei Kogyo Co., Ltd., this system uses a combination of a five-chamber waste treating septic tank designed by Taisei, effluent disposed-of by an evaporation-transpiration system through aerated soil (effluent spread horizontally and upwards from distribution piping).

RV Holding Tank & Toilet Deodorants, Treatments, Cleaners

  • Coleman Corporation, provides a wide range of camping equipment including Coleman Holding Tank Deodorant Products & Coleman Portable Flush Toilets [Instruction Manual] - web search 08/27/2010, original source: http://www.coleman.com/coleman/images/pdf/2000001533.pdf
  • Elsan Limited, Bellbrook Park, Uckfield, East Sussex TN22 1QF, England. Telephone: +44 (0) 1825 748200. The company produces chemical toilet sanitation and hygiene products for caravanning, camping and boating. Quoting from the company's website: web search 08/27/2010, original source http://www.elsan.co.uk/about-elsan.html
    While Elsan Blue toilet fluid exceeds British and European Standards BS:EN 2893:2005, no other brand even claims to comply with them.
    ... because it is biodegradable and free from harsh chemicals, [Elsan organic toilet fluid] can be safely emptied into a septic tank.
    Technical data requested by email to Elsan: 8/27/2010 - DF
  • Marykate Heads Up holding tank deodorant [MSDS], web search 08/27/2010, original source for the Marykate Heads Up deodorant MSDS
    http://www.crcindustries.com/marine/content/prod_detail_print.aspx?PN=MK4532
    Marykate products appear to be produced by CRC Industries,
  • Thetford Corporation, 7101 Jackson Road, Ann Arbor, MI 48103, Tel: 1-800-543-1219, Mailing Address: P.O. Box 1285, Ann Arbor, MI 48106 web search 08/27/2010, original source: http://www.thetford.com/Home/Products/ChemicalsCleanersHome
    /AquaKemLiquidTossInsandDri/tabid/122/Default.aspx Quoting from the company's website:
    [Aqua-Kem Products are] 100% biodegradable liquid and environmentally safe when disposed of properly
  • Also see Septic & Holding/RV Tank/Toilet Chemicals MSDS

Questions & Answers regarding this article

.

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Recommend / Share this Article            

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also include a list of recommended books for the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

  ALTERNATIVE SEPTIC PRODUCTS
    AEROBIC Septic System ATU SUPPLIERS
    Alternative Septic System Product Suppliers
    Septic System Filters
    Gravelless Leach Field Systems

  • Septic Treatments Additives discusses the objections to septic chemicals and additives for septic tank "maintenance", drain field un-clogging, etc.
  • Septic Tanks - Polyurethane plastic FRALO "makes the world's strongest poly septic tank with a 50 year guarantee!" www.fralo.net
  • MicroSepTec offers engineered alternative onsite waste disposal systemsMicroSepTec advanced residential/light-commercial onsite wastewater treatment, pre-engineered, cost effective, environmentally friendly. Meets requirements of owners, designers, health departments. Replacement for failed septic systems. Free consult. 949-855-3500 949-855-3515 fax. E-mail: dvana@microseptec.com
  • Septic Tank Heaters In some places it may be necessary to keep a septic tank warm to work properly. HST has a new low voltage heater that is attached to the outside of the tank. [Thanks to Neil Grosz for this tip.]
  • Tafgard soil based wastewater evaporation / transpiration system by Taisei Kogyo Co., Ltd., Japan. Contact Shuichi Sato, Manager of Taisei Kogyo Co., Ltd., 15-36 Yonehara 6-chome, Yonago, Tottori, 683-0804 Japan Tel. +81-859-32-1135 Fax. +81-859-34-0933, info@taisei-wastewater.jp
  • Tipton Environmental International developed a high efficient wastewater treatment system that will produce the quality of effluent our environment requires. This effluent can then be used for garden water, irrigation, gray water systems or many other applications.

  • Listing submissions welcome, there is no listing fee. InspectAPedia.com - Directory Listing & Link Exchange Instructions. Add your listing & support InspectAPedia.com by exchanging links - no listing fee & no conflicts of interest.

Directory Lists of Septic System Parts & Supplies

  • Aerobic Septic System Products Directory List
  • Alternative Septic System Product Suppliers List
  • Filters, Septic Filters & Wastewater Treatment Systems Using Filtration Methods Products Directory
  • Gravelless Leach Field Septic Systems Products Directory List
  • Septic Effluent Distribution Products Directory List
  • Toilets, Composting Toilets, Biological Toilets, No-water/Low water toilets, Waterless toilets, Chemical Toilets, Inicnerating Toilets and related products list
  • Other Septic Wastewater Treatment Products List
  • Plumbers & Septic Repair Companies List
  • Septic Tanks septic tank suppliers

Listing submissions welcome, there is no listing fee. InspectAPedia.com - Directory Listing & Link Exchange Instructions. Add your listing & support InspectAPedia.com by exchanging links - no listing fee & no conflicts of interest.

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Inspecting Septic Systems: Online Book, Inspection, Test, Diagnosis, Repair, & Maintenance: our Online Septic Book: Septic Testing, Loading & Dye Tests, Septic Tank Pumping, Clearances, details of onsite waste disposal system inspection, testing, repair procedures.

  • Advanced Onsite Wastewater Systems Technologies, Anish R. Jantrania, Mark A. Gross. Anish Jantrania, Ph.D., P.E., M.B.A., is a Consulting Engineer, in Mechanicsville VA, 804-550-0389 (2006). Outstanding technical reference especially on alternative septic system design alternatives. Written for designers and engineers, this book is not at all easy going for homeowners but is a text I recommend for professionals--DF.
  • Builder's Guide to Wells and Septic Systems, Woodson, R. Dodge: $ 24.95; MCGRAW HILL B; TP; Quoting from Amazon's description: For the homebuilder, one mistake in estimating or installing wells and septic systems can cost thousands of dollars. This comprehensive guide filled with case studies can prevent that. Master plumber R. Dodge Woodson packs this reader-friendly guide with guidance and information, including details on new techniques and materials that can economize and expedite jobs and advice on how to avoid mistakes in both estimating and construction. Chapters cover virtually every aspect of wells and septic systems, including on-site evaluations; site limitations; bidding; soil studies, septic designs, and code-related issues; drilled and dug wells, gravel and pipe, chamber-type, and gravity septic systems; pump stations; common problems with well installation; and remedies for poor septic situations. Woodson also discusses ways to increase profits by avoiding cost overruns.
  • Country Plumbing: Living with a Septic System, Hartigan, Gerry: $ 9.95; ALAN C HOOD & TP; Quoting an Amazon reviewer's comment, with which we agree--DF:This book is informative as far as it goes and might be most useful for someone with an older system. But it was written in the early 1980s. A lot has changed since then. In particular, the book doesn't cover any of the newer systems that are used more and more nowadays in some parts of the country -- sand mounds, aeration systems, lagoons, etc.

Design Manuals for Septic Systems

  • US EPA Onsite Wastewater Treatment Systems Manual [online copy, free] Top Reference: US EPA's Design Manual for Onsite Wastewater Treatment and Disposal, 1980, available from the US EPA, the US GPO Superintendent of Documents (Pueblo CO), and from the National Small Flows Clearinghouse. Original source http://www.epa.gov/ORD/NRMRL/Pubs/625R00008/625R00008.htm Onsite wastewater treatment and disposal systems, Richard J Otis, published by the US EPA. Although it's more than 20 years old, this book remains a useful reference for septic system designers. U.S. Environmental Protection Agency, Office of Water Program Operations; Office of Research and Development, Municipal Environmental Research Laboratory; (1980)
  • Eco John® Innovative Toilet Solutions, Global Inventive Industries, Fountain Valley CA, PDF, product brochure
  • "International Private Sewage Disposal Code," 1995, BOCA-708-799-2300, ICBO-310-699-0541, SBCCI 205-591-1853, available from those code associations.
  • "Manual of Policy, Procedures, and Guidelines for Onsite Sewage Systems," Ontario Reg. 374/81, Part VII of the Environmental Protection Act (Canada), ISBN 0-7743-7303-2, Ministry of the Environment,135 St. Clair Ave. West, Toronto Ontario M4V 1P5 Canada $24. CDN.
  • Manual of Septic Tank Practice, US Public Health Service's 1959.

Onsite Wastewater Disposal Books

  • Onsite Wastewater Disposal, R. J. Perkins; Quoting from Amazon: This practical book, co-published with the National Environmental Health Association, describes the step-by-step procedures needed to avoid common pitfalls in septic system technology. Valuable in matching the septic system to the site-specific conditions, this useful book will help you install a reliable system in both suitable and difficult environments. Septic tank installers, planners, state and local regulators, civil and sanitary engineers, consulting engineers, architects, homeowners, academics, and land developers will find this publication valuable.
  • Onsite Wastewater Treatment Systems, Bennette D. Burks, Mary Margaret Minnis, Hogarth House 1994 - one of the best septic system books around, suffering a bit from small fonts and a weak index. While it contains some material more technical than needed by homeowners, Burks/Minnis book on onsite wastewater treatment systems a very useful reference for both property owners and septic system designers.
  • Septic Tank/Soil-Absorption Systems: How to Operate & Maintain [ copy on file as /septic/Septic_Operation_USDA.pdf ] - , Equipment Tips, U.S. Department of Agriculture, 8271 1302, 7100 Engineering, 2300 Recreation, September 1982, web search 08/28/2010, original source: http://www.fs.fed.us/t-d/pubs/pdfimage/82711302.pdf
  • Soil Percolation Tests soil perc testing guide and instructions
  • Percolation Testing Manual, CNMI Division of Environmental Quality, PO Box 501304, Saipan, MP 96950
  • Planting Over Septic System Component", Daniel Friedman (author/editor, InspectAPedia.com), The Innovator, Winter/Spring 2008, BCOSSA, British Columbia OnSite Sewage Association, 201-3542 Blansard St., Victoria BC V8X 1W3 Canada
  • Save the Septic System - Do Not Flush These Items Down the Toilet, Daniel Friedman, InspectAPedia.com - PDF document, printable
  • SEPTIC STANDARDS
  • SEPTIC MAGAZINES
  • Septic System Owner's Manual, Lloyd Kahn, Blair Allen, Julie Jones, Shelter Publications, 2000 $14.95 U.S. - easy to understand, well illustrated, one of the best practical references around on septic design basics including some advanced systems; a little short on safety and maintenance. Both new and used (low priced copies are available, and we think the authors are working on an updated edition--DF. Quoting from one of several Amazon reviews: The basics of septic systems, from underground systems and failures to what the owner can do to promote and maintain a healthy system, is revealed in an excellent guide essential for any who reside on a septic system. Rural residents receive a primer on not only the basics; but how to conduct period inspections and what to do when things go wrong. History also figures into the fine coverage.
  • Test Pit Preparation for Onsite Sewage Evaluations, State of Oregon Department of Environmental Quality, Portland OR, 800 452-4011. PDF document. We recommend this excellent document that offers detail about soil perc tests, deep hole tests, safety, and septic design. Readers should also see Soil Percolation Tests and for testing an existing septic system, also see Dye Tests
  • Grass is Always Greener Over the Septic Tank, Bombeck, Erma: $ 5.99; FAWCETT; MM; This septic system classic whose title helps avoid intimidating readers new to septic systems, is available new or used at very low prices. It's more entertainment than a serious "how to" book on septic systems design, maintenance, or repair. Not recommended -- DF.
  • US EPA Onsite Wastewater Treatment Systems Manual Top Reference: US EPA's Design Manual for Onsite Wastewater Treatment and Disposal, 1980, available from the US EPA, the US GPO Superintendent of Documents (Pueblo CO), and from the National Small Flows Clearinghouse. Original source http://www.epa.gov/ORD/NRMRL/Pubs/625R00008/625R00008.htm
  • Water Wells and Septic Systems Handbook, R. Dodge Woodson. This book is in the upper price range, but is worth the cost for serious septic installers and designers. Quoting Amazon: Each year, thousands upon thousands of Americans install water wells and septic systems on their properties. But with a maze of codes governing their use along with a host of design requirements that ensure their functionality where can someone turn for comprehensive, one-stop guidance? Enter the Water Wells and Septic Systems Handbook from McGraw-Hill.
    Written in language any property owner can understand yet detailed enough for professionals and technical students this easy-to-use volume delivers the latest techniques and code requirements for designing, building, rehabilitating, and maintaining private water wells and septic systems. Bolstered by a wealth of informative charts, tables, and illustrations, this book delivers:
    * Current construction, maintenance, and repair methods
    * New International Private Sewage Disposal Code
    * Up-to-date standards from the American Water Works Association
  • Wells and Septic Systems, Alth, Max and Charlet, Rev. by S. Blackwell Duncan, $ 18.95; Tab Books 1992. We have found this text very useful for conventional well and septic systems design and maintenance --DF. Quoting an Amazon description:Here's all the information you need to build a well or septic system yourself - and save a lot of time, money, and frustration. S. Blackwell Duncan has thoroughly revised and updated this second edition of Wells and Septic Systems to conform to current codes and requirements. He also has expanded this national bestseller to include new material on well and septic installation, water storage and distribution, water treatment, ecological considerations, and septic systems for problem building sites.
  • The NSFC Products List has an excellent list of design manuals/modules available from their website or by telephone 800-624-8301
  • Submissions welcome. send us a suggested document link or request an exchange of website links
  • ...

Home About Us Accuracy Contact Us Content Use Policy Printing Tips Privacy Website Description © 2012 Copyright InspectAPedia.com