SEPTIC SYSTEM INSPECT DIAGNOSE REPAIR

SEPTIC CARE INSTRUCTIONS
SEPTIC CONSULTANTS
SEPTIC D-BOX INSPECTION
SEPTIC DRAINFIELD FAILURE DIAGNOSIS
SEPTIC DRAWINGS
SEPTIC DYE TEST PROCEDURE
SEPTIC FAILURE SIGNS
SEPTIC INSPECTION & TEST GUIDE
SEPTIC LIFE EXPECTANCY
SEPTIC ODORS
SEPTIC PUMPS
SEPTIC SUPPLIES & PARTS
SEPTIC SYSTEM DESIGN ALTERNATIVES
SEPTIC SYSTEM DESIGN BASICS
SEPTIC SYSTEMS, HOME BUYERS GUIDE to
SEPTIC SYSTEM SAFETY WARNINGS
SEPTIC TANKS
SEPTIC TREATMENTS & CHEMICALS
SEWAGE & SEPTIC CONTAMINANTS
SEWAGE BACKUP, WHAT TO DO
SEWAGE BACKUP TEST & CLEANUP
SEWAGE BACKUP PREVENTION
SEWAGE CONTAMINATION in buildings
SEWAGE CONTAMINANTS in FRUIT / VEGETABLES
SEWAGE EJECTOR / GRINDER PUMPS
SEWAGE LEVELS in SEPTIC TANKS
SEWAGE NITROGEN CONTAMINANTS
SEWAGE PATHOGENS in SEPTIC SLUDGE
SEWAGE PUMPS
SEWER BACKUP PREVENTION
SEWER GAS ODORS
SEWER LINE REPLACEMENT
SINKHOLES, WARNING SIGNS
SMELL PATCH TEST to Track Down Odors
SOAKAWAY BED FAILURE DIAGNOSIS
SULPHUR & SEWER GAS SMELL SOURCES
SUMP PUMPS

TOILETS, INSPECT, INSTALL, REPAIR
TOILET ALTERNATIVES
TOILETS, DON'T FLUSH LIST
TRAPS on PLUMBING FIXTURES
TREATMENTS & CHEMICALS, SEPTIC

VIDEO GUIDES: Septic Videos

WASHING MACHINES & SEPTIC SYSTEMS
WATER SOFTENERS & CONDITIONERS
WATER SUPPLY & DRAIN PIPING
WASTEWATER TREATMENT BASICS
WATER, WELLS, WATER TANKS: TESTING GUIDE
WINTERIZE A BUILDING

More Information

Photograph of septic drain line excavation in process.

Sewer Line or Septic Tank Line Replacement Procedure - step by step guide
     

  • Replacing the Sewer Line, Step by Step - Here are details in how a sewer line is replaced; Step by step main drain line replacement, house to septic tank (or sewer)
  • SEWER LINE REPLACEMENT
    • Diagnosing a Blocked Drain
    • When to Call a Plumber
    • How to Locate the Main Building Drain
    • How to Use a Power Snake on Building Drains
    • How to Find Distance to Drain Blockage
    • Determining Need for Replacement
    • Replacing the Sewer Line, Step by Step
    • Making Other Septic Repairs
    • Installing the new sewer line
    • Bedding the sewer line in Sand
    • Final Backfill of the Sewer Line Trench
    • Documenting Buried Components
    • Final seeding and soil restoration
    • Sewer or Septic Line Installation at Steep Sites
  • Questions & Answers about the steps in replacing a leaky or damaged sewer pipe or main building drain between the building and the sewer or septic tank
  • References

Click to Show or Hide Related Topics

  • SEPTIC SYSTEM INSPECT DIAGNOSE REPAIR - home
  • BACKUP PREVENTION, SEPTIC
  • BACKUP PREVENTION, SEWER
  • CHEMICALS & TREATMENTS for SEPTICS
  • CLEARANCE DISTANCES, SEPTIC SYSTEM
  • CLOGGED DRAIN DIAGNOSIS & REPAIR
  • D BOX TROUBLESHOOTING
  • DRAIN CLEANOUTS
  • DRYWELL DESIGN & USES
  • EFFLUENT RETENTION TIME
  • FILTERS SEPTIC & GREYWATER
  • GARBAGE DISPOSAL vs SEPTICS
  • ODORS, PLUMBING SYSTEM
  • ODORS, SEPTIC or SEWER
  • SEPTIC DRAINFIELD INSPECTION & TEST - home
    • DISPOSAL CLOGGING FAILURES
    • ODORS INDICATING DRAINFIELD FAILURE
    • SEPTIC DRAINFIELD FAILURE CAUSES
    • SEPTIC DRAINFIELD FAILURE DIAGNOSIS
  • SEPTIC DRAINFIELD LIFE
  • SEPTIC DRAINFIELD LOCATION
  • SEPTIC DRAINFIELD RESTORERS?
  • SEPTIC DRAINFIELD SIZE
  • SEPTIC DRAINFIELD SHAPE
  • SEPTIC INSPECTION & TEST GUIDE
  • SEPTIC DRAINFIELD INSPECTION & TEST - home
  • SEPTIC LOADING & DYE TEST PROCEDURE - home
  • SEPTIC MAINTENANCE INSTRUCTIONS
  • SEPTIC PUMPS
  • SEPTIC PUMPING REPAIR
  • SEPTIC SYSTEM REPAIR
  • SEPTIC TANK BAFFLES
  • SEPTIC TANK CLEANING
  • SEPTIC TANK, HOW TO FIND
  • SEPTIC TANK INSPECTION PROCEDURE - home
  • SEPTIC TANK LEVELS of SEWAGE
  • SEPTIC TANK PUMPING SCHEDULE
  • SEPTIC TANK TEES
  • SEPTIC SYSTEM DESIGN - home
  • SEPTIC SYSTEM INSPECTION & TEST GUIDE - home
  • SEPTIC TESTS: DYE & LOADING TESTS
  • SEPTIC TREATMENTS & CHEMICALS
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

Sewer or Septic Drain Line Replacement Procedure - complete guide: this series article describes the detailed steps taken when, where, how, and why a sewer pipe or "drain line" is replaced. By sewer line we refer to either the drain connecting the building to a public sewer or the drain pipe connecting the building to a private septic tank.

Green links show where you are. © Copyright 2013 InspectAPedia.com, All Rights Reserved. Author Daniel Friedman.

Replacing the Sewer Line, a Step by Step Photo Guide

Photograph of septic drain line excavation in process.Photograph of septic drain line excavation in process.

The sewer/septic pipeline which was replaced in this photo-illustrated case runs from the building exterior to a septic tank located downhill from the home. Technical reviewers are welcome and are listed at "References." This is a chapter of Inspecting, Testing, & Maintaining Residential Septic Systems an online book on septic systems. Also see Backups and Clogged Drains diagnosing septic backups and septic system failures versus clogged drains.

Because we were working in a tight space with nearby buildings and power lines, a skilled backhoe operator was essential for the work.

The backhoe operator was a master and could probably have moved eggs around without breaking them if he wanted to show off.

The old sewer line was excavated and removed from near the house down to near the septic tank using the backhoe.

The operator moved the concrete sections of sidewalk aside so that if we wanted, they could later simply be replaced and re-used. (Later we elected to have them removed from the site entirely).

Photograph of sewer line excavation by hand.

Final excavation of the drain line near the septic tank and near the house were completed by hand so as to avoid possible damage to a near by deck pier, to the waste line we wanted to connect-to just outside the foundation wall, and to the septic tank.

The details of this sewer line replacement article are divided as shown just below:

SEWER LINE REPLACEMENT
  Diagnosing a Blocked Drain
  When to Call a Plumber
  How to Locate the Main Building Drain
  How to Use a Power Snake on Building Drains
  How to Find Distance to Drain Blockage
  Determining Need for Replacement
  Replacing the Sewer Line, Step by Step
  Making Other Septic Repairs
  Installing the new sewer line
  Bedding the sewer line in Sand
  Final Backfill of the Sewer Line Trench
  Documenting Buried Components
  Final seeding and soil restoration
  Sewer or Septic Line Installation at Steep Sites

...


Frequently Asked Questions (FAQs)

...

Ask a Question or Search InspectApedia

Questions & answers or comments about the steps in replacing a leaky or damaged sewer pipe or main building drain between the building and the sewer or septic tank.

Ask a Question or Enter Search Terms in the InspectApedia search box just below.

Technical Reviewers & References

Related Topics, found near the top of this page suggest articles closely related to this one.

  • Thanks to Thomas Gleason, excavators, Poughkeepsie, NY 845-454-3730, for the excavating work at the project photo documented here in September 2006
  • Thanks to Cleveland Plumbing, the prime plumbing contractor, Staatsburgh, NY 845-485-7700 for the plumbing work and drain clog diagnosis work documented here in September 2006

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson DunlopThe Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.

    Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.

  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
    Building inspection education & report writing systems from Carson, Dunlop & Associates Ltd
  • Inspecting Septic Systems: Online Book, Inspection, Test, Diagnosis, Repair, & Maintenance: our Online Septic Book: Septic Testing, Loading & Dye Tests, Septic Tank Pumping, Clearances, details of onsite waste disposal system inspection, testing, repair procedures.

  • Advanced Onsite Wastewater Systems Technologies, Anish R. Jantrania, Mark A. Gross. Anish Jantrania, Ph.D., P.E., M.B.A., is a Consulting Engineer, in Mechanicsville VA, 804-550-0389 (2006), Advanced Onsite Wastewater Systems Technologies. Outstanding technical reference especially on alternative septic system design alternatives. Written for designers and engineers, this book is not at all easy going for homeowners but is a text we recommend for professionals--DF. I>
  • Builder's Guide to Wells and Septic Systems, Woodson, R. Dodge: $ 24.95; MCGRAW HILL B; TP; Quoting from Amazon's description: For the homebuilder, one mistake in estimating or installing wells and septic systems can cost thousands of dollars. This comprehensive guide filled with case studies can prevent that. Master plumber R. Dodge Woodson packs this reader-friendly guide with guidance and information, including details on new techniques and materials that can economize and expedite jobs and advice on how to avoid mistakes in both estimating and construction. Chapters cover virtually every aspect of wells and septic systems, including on-site evaluations; site limitations; bidding; soil studies, septic designs, and code-related issues; drilled and dug wells, gravel and pipe, chamber-type, and gravity septic systems; pump stations; common problems with well installation; and remedies for poor septic situations. Woodson also discusses ways to increase profits by avoiding cost overruns.
  • Country Plumbing: Living with a Septic System, Hartigan, Gerry: $ 9.95; ALAN C HOOD & TP; Quoting an Amazon reviewer's comment, with which we agree--DF:This book is informative as far as it goes and might be most useful for someone with an older system. But it was written in the early 1980s. A lot has changed since then. In particular, the book doesn't cover any of the newer systems that are used more and more nowadays in some parts of the country -- sand mounds, aeration systems, lagoons, etc.

Design Manuals for Septic Systems

  • US EPA Onsite Wastewater Treatment Systems Manual [online copy, free] Top Reference: US EPA's Design Manual for Onsite Wastewater Treatment and Disposal, 1980, available from the US EPA, the US GPO Superintendent of Documents (Pueblo CO), and from the National Small Flows Clearinghouse. Original source http://www.epa.gov/ORD/NRMRL/Pubs/625R00008/625R00008.htm Onsite wastewater treatment and disposal systems, Richard J Otis, published by the US EPA. Although it's more than 20 years old, this book remains a useful reference for septic system designers. U.S. Environmental Protection Agency, Office of Water Program Operations; Office of Research and Development, Municipal Environmental Research Laboratory; (1980)
  • Eco John® Innovative Toilet Solutions, Global Inventive Industries, Fountain Valley CA, PDF, product brochure
  • "International Private Sewage Disposal Code," 1995, BOCA-708-799-2300, ICBO-310-699-0541, SBCCI 205-591-1853, available from those code associations.
  • "Manual of Policy, Procedures, and Guidelines for Onsite Sewage Systems," Ontario Reg. 374/81, Part VII of the Environmental Protection Act (Canada), ISBN 0-7743-7303-2, Ministry of the Environment,135 St. Clair Ave. West, Toronto Ontario M4V 1P5 Canada $24. CDN.
  • Manual of Septic Tank Practice, US Public Health Service's 1959.