Mobile ViewSEPTIC SYSTEM INSPECT DIAGNOSE REPAIR SEPTIC SYSTEM ARTICLES Septic Guide for Home Buyers or Owners Septic or Sewer Connection? Septic System Design Septic System Designs Master List Septic Inspection Testing Septic Maintenance Repair ALTERNATING BED SEPTIC SYSTEMS BACKUP PREVENTION, SEPTIC BACKUP PREVENTION, SEWER LINE BACKWATER VALVES, SEWER LINE BIOLOGICAL POLLUTANTS BOOKS, RECOMMENDED SEPTIC BOOKSTORE, SEPTIC SYSTEMS CESSPOOLS CESSPOOL SAFETY WARNINGS CHECK VALVES, WATER SUPPLY CHEMICALS & TREATMENTS for SEPTICS CHLORAMINE / CHLORINE Tests CHLORINE IN DRINKING WATER CHLORINE IN SEPTIC WASTEWATER CISTERNS D BOX TROUBLESHOOTING DEFINITIONS OF SEPTIC SYSTEM TERMS DIFFICULT SEPTIC SITES DISTRIBUTION-BOX INSPECTION, SEPTIC DRAINFIELD FAILURE DIAGNOSIS DRIVING or PARKING OVER SEPTIC DRYWELL DESIGN & USES EFFLUENT RETENTION TIME FILTERS SEPTIC & GREYWATER FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP FLOODED SEPTIC SYSTEMS, REPAIR GARBAGE DISPOSAL vs SEPTICS GRAVELLESS SEPTIC SYSTEMS GRAVITY/SIPHON DOSING SYSTEMS GREYWATER SYSTEMS HOME BUYERSGUIDE to SEPTIC SYSTEMS 1-INTRODUCTION 2-YOU NEED TO KNOW AND DO 3-SEPTIC SYSTEM COMPONENTS 4-WHAT GOES WRONG 5-HOW TO INSPECT & TEST 6-FINAL OVERVIEW SEPTIC FAILURE LAWSUIT HOME SELLERS GUIDE TO SEPTIC INSPECTION The Basics of Buying a Home with a Septic Tank Document Purpose Components of a Septic System How to Inspect and Test Testing Step-by-Step Leachfields Signs of Septic Trouble Sources of Septic Info Info from Owner Visual Inspection Town Health Dept Outside Sources Final Overview LAGOON SEPTIC SYSTEMS LEACHFIELD FAILURE DIAGNOSIS MEDIA FILTER SEPTIC SYSTEMS MOUND SEPTIC SYSTEMS NOISE / SOUND DIAGNOSIS & CURE ODORS & SMELLS DIAGNOSIS & CURE ODOR DIAGNOSIS CHECKLIST ODORLESS CHEMICALS / GASES: CHECK FOR? ODORS, PLUMBING SYSTEM ODORS, SEPTIC or SEWER ODORS, SULPHUR SMELL SOURCES OUTHOUSES & LATRINES PLANTS & TREES OVER SEPTIC SYSTEMS PRESSURE DOSING SEPTIC SYSTEMS RAISED BED SEPTIC SYSTEMS SAND BED SEPTIC SYSTEMS SEEPAGE PITS SEPTIC & CESSPOOL SAFETY SEPTIC SYSTEM, HOME BUYERS GUIDE 1-INTRODUCTION 2-YOU NEED TO KNOW AND DO 3-SEPTIC SYSTEM COMPONENTS 4-WHAT GOES WRONG 4-1 TANK FAILURES 4-2 PIPING FAILURES 4-3 LEACH FIELD FAILURES 4-4 OTHER SEPTIC TROUBLE SIGNS 5-HOW TO INSPECT & TEST 6-FINAL OVERVIEW SEPTIC FAILURE LAWSUIT SEPTIC SYSTEM PUMPS SEPTIC PUMPING REPAIR SEPTIC SYSTEM ODORS SEPTIC SYSTEM PUMPS SEPTIC SYSTEM SAFETY WARNINGS SEPTIC SYSTEM TYPES, MASTER LIST SEPTIC TANKS SEPTIC TANK, HOW TO FIND SEPTIC TANK INSPECTION PROCEDURE SEPTIC TANK PUMPING SCHEDULE SEPTIC TESTS: DYE & LOADING TESTS SEPTIC TEST VOLUMES & DYE AMOUNTS SEPTIC TREATMENTS & CHEMICALS SEPTIC SYSTEM DESIGN ALTERNATIVES SEPTIC SYSTEM DESIGN BASICS SEWAGE & SEPTIC CONTAMINANTS SEWAGE BACKUP, WHAT TO DO SEWAGE BACKUP TEST & CLEANUP SEWAGE BACKUP PREVENTION SEWAGE PUMPS SEWAGE PUMP CLOG DAMAGE SEWER BACKUP PREVENTION SEWER GAS ODORS TOILET REPAIR GUIDE TOILETS, DON'T FLUSH LIST WATER, WELLS, WATER TANKS: TESTING GUIDE WATER SOFTENERS & CONDITIONERS WATER SUPPLY & DRAIN PIPING More Information |
Here we offer some advice for home owners who are selling a property with a septic system, including useful information that you can prepare and provide to a home buyer, septic system testing, and making septic system safety repairs before even listing a property for sale. InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers nor with topics or services discussed at this website.No one wants to see a condition like the failing septic system shown just above, but isn't it just the rotten luck that sometimes problems like this show up right when you're trying to sell a home?. © Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website. Advice When Selling a Home With A Septic SystemQuestion from a reader who is selling a home with a septic system: My brother and I are helping sell my parents house in Massachusetts, and we were told we had to have this inspection done. We don't know what kinds of questions to ask when interviewing potential inspectors - can you give us some insight into how to best research this? We want the best possible chance of having a positive, no issues inspection, so again we would appreciate your advice. Tips for Sellers of Homes With Septic SystemsAvoid a Conflict of Interest about Reporting Septic System ConditionTo avoid a conflict of interest all parties to a real estate sale should prefer to see a Title5-type septic inspection and any other condition of property inspection ordered by the buyer not by the seller. Otherwise, later if a problem is found by the new owner the seller could be charged with providing self serving, inaccurate information. Use a Qualified Septic System InspectorAll Title 5 inspectors working in MA are licensed and must be trained. Septic system inspectors in other states and provinces may also be required to be licensed or registered, though many excellent septic system inspections are also offered by some home inspectors as well as some septic contractors. Do not hire an inspector for septic or other inspections if s/he has a conflict of interest such as one who also offers repair services for the property to be inspected, nor an inspector who has a relationship with the home buyer, seller, or real estate agent. Ask about the septic system inspector's experience. Ask to see an example septic inspection report and compare its contents with the requirements specified by law in Title5 and with the septic inspection reports described at this website. Prepare and Provide Basic Homeowner Information About the Septic SystemProvide the most accurate information possible about the septic system age, location of components, type of components, service and repair history you can. You may not know all of these things but the more you know an provide the more accurate will be the septic report and the less pure speculation will be involved. Speculation by a septic system inspector, in the absence of actual information, can lead to worst-case guesses or warnings to a buyer, issued not so much to protect the buyer as to protect the septic inspector - to reduce risk of a buyer's later complaint about the inspector's diligence. But such a septic system condition report, in which the inspector spends your money to reduce his/her risk, can result in premature, inappropriate, or excessive septic system repair repair costs. What if the Septic System Needs Repairs Right When We're Selling Our Home?If you already know of a septic system failure or unsafe condition or of a problem that is easily corrected, such as a flimsy septic tank cover or surface runoff invading the drainfield fix these right away - we don't want a prospective buyer falling into the septic tank, and drying out a wet leach field caused by invading ground water will improve its function. If there is already evidence of a septic system problem, such as odors, wet areas, or sewage backups, obtain several repair estimates, including a reliable diagnosis of just what the problem is. Repair costs range from trivial (unclogging a pipe) to significant (replacing a septic system). Do not try to "hide" a problem by pumping the septic tank. Such a step is very short-term (hours or a day or so), and may constitute a fraudulent or illegal act. Of course if you have to pump a failed septic system tank so as to have emergency ability to flush toilets, go ahead, but inform the parties concerned of this condition. If the septic inspection indicate a costly problem, get further, accurate diagnosis and repair cost estimates from one or more septic repair companies - more than one approach and cost may be feasible. Repair work bids should be from a septic repair company having no relationship with the septic inspector. Since high costs and even life-safety issues could be involved in some septic system problems, responsible accurate septic reports, not just a septic report whose results make us happy, are of paramount concern. Since some lenders will not write a mortgage on a property unless the septic system is working, you may have to go ahead and perform the necessary repair work. Generally, unless immediate functional or safety repairs are needed, we prefer to obtain estimates and then to negotiate with the buyer on that amount, perhaps offering the repair cost as an allowance against the purchase price of the property. Why? Because the new owner - buyer will be more confident that the repairs were done properly if s/he is in control of that work, and the seller will be free of any future liability concerning the septic system. What if the Septic System Inspection and Report are Faulty?If the septic system inspection yields a result that seems unclear, inaccurate, or just plain wrong, or if its confusing, ask for clarification from the inspector, and also pass that information and question along to me by email- I may have a suggestion Frequently Asked Questions (FAQs) about selling a home with a septic tankQuestion: Our first septic system test failed, the second one that was less thorough passed. The buyers want a whole new septic system. What should we do?I am curious what you would say about my current situation. I'm in the middle of an inspection w/ buyers. The first septic inspection failed a flow test. We have had no issues [with our septic system] in the 13 years we've been in the house. The system is old [built probably in ] 1965. We've found no map of the field and no one has found the field. We had a second opinion inspection without a flow test [septic loading test]. The septic system passed [this second procedure]. Tank was emptied and inspected. He said he found no high water marks. No damage found to tank. Buyers wanted another opinion so our agents hired a company- this company failed the system. Used a camera in the out pipe which was holding water and followed it down to a place on the lawn just staring to green up and found the soil there saturated. They said the system was about to fail, but couldn't located any leaching system. No break out or odor. They also claim to have found a hairline crack in the septic tank. Now the buyers want us to replace the whole system, septic tank included and to use the company that last inspected! What do you think? I think it stinks, but my lawn doesn't. Reply: Avoid a future dispute, find out what repairs are really needed, fix or escrowA septic loading and dye test cannot find all possible septic problems but it can find enough to be worth doing, and if the septic loading and dye test was properly performed, it can protect both buyer and seller from a later dispute. The legal question of what you should do in the case of a failed septic system is one to take to your lawyer. That said, my OPINION is that these are some points to consider:
- DJF - editor. Questions & Answers regarding this articleQuestions & Answers about selling a home with a septic tank or septic system or soakaway bed system Ask a Question or Search InspectAPediaHTML Comment Box is loading comments...
Recommend / Share this Article
... Technical Reviewers & References
Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website. HOME BUYERSGUIDE to SEPTIC SYSTEMS Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair
Design Manuals for Septic Systems
Onsite Wastewater Disposal Books
|