|
|
Sources for Roofing Slate, Slate Roof Tools, Slate Roof Suppliers
|
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
Where to buy roofing slate or slate roofing tools: this article describes slate sources and where to buy slate roofing materials and slate roofing tools and products. This is a detailed article describing procedures for evaluating the condition of slate roofing. How to inspect, identify defects, and estimate remaining life of slate roofs are addressed. The article also references slate repair procedures, repair slate sources, and slate quarries.
Green links show where you are. © Copyright 2013 InspectAPedia.com, All Rights Reserved. Author Daniel Friedman.
Slate Roof Replacement & Repair Sources
If less than 25% of the slates on a roof are damaged or sliding down from worn out nails,
slate repairs are in order. Luckily replacement slates are available from a variety of
slate quarries, slate suppliers, and slate roofing companies.
Slate "look alike" products
are also available using cementious materials. If the building owner cannot afford to
repair a slate roof where most slates are intact, holding action slate roof repairs should be
followed, such as simply sliding metal flashing up under broken or missing slates on the roof.
We purchased this slate removing tool (also useful for removing other types of roof shingles where careful work is needed) at Davies Hardware, on Main Street in Poughkeepsie, NY.
Roofing & Slating Tool Suppliers
- John Stortz & Son Inc, 210 Vine St., Philadelphia, PA 19106. Website: www.stortz.com, Tel: 888-847-3456 or 215-627-3855. Stortz has been producing and selling hand tools since 1953. The company's slate roofing tools include slate cutters, hammers,slate rippers (similar to our blue ripper shown above), slaters stakes, slate hooks (see our article on SLATE ROOF REPAIRS), a power slate cutter, and other tools.
Roofing Slate Suppliers
- Buckingham Slate Co., 4110 Fitzhugh Ave., Richmond, VA
23230; 805/355-4351 (VA Buckingham Grey)
- Evergreen Slate Co., 68 Potter Ave., Granville, NY 12832;
518/642-2530. Vermont slates in 10 colors.
- Hilltop Slate Co., Middle Granville, NY 12849; 518/642-2270
(all VT colors plus imported Spanish Black)
- Rising & Nelson Slate Co., West Pawlet, VT 05775; 802/645-0150
(all VT colors plus Buckingham Gray from VA and blacks from PA
- Structural Slate Co., Pen Argyl, PA 18072; 215/863-4145
(PA black)
- Vermont Structural Slate Co., PO Box 98 Fair Haven, VT
05743 802/265-4933 802/265-3865 FAX (Green, purple, unfading red,
and Spanish imported black.)
In addition to these slate sources there are several slate look-alike
substitutes. While the application techniques, flashing and nailing
concerns are similar, the wear characteristics of these materials
may be quite different and were not evaluated for this paper. This
paper is not an endorsement, nor a critique of any of these materials.
- Eternit, Inc., rigid fiber reinforced cement roofing slates
(and board products. Village Center Drive, Reading, PA 19607 800/233-3155
- BritSlateTM are made from 100% quarried slate particles
combined with an adhesive (epoxy?) and no fillers with no questionable
side effects according to the manufacturer. According to the manufacturer,
they can be cut, drilled, etc. and come with a 50-year guarantee.
They're less prone to breakage than slate, fireproof, and do not absorb
water (like natural slate), and do not encourage organic growth (moss
and lichens) because they are not porous. BritSlate North America,
Inc., 647 West Boylston St., Worcester, MA 01606 508/852-4888 508/852-7224
FAX 2/90.
- Reinforced-cement shingles which "look like slate but are
lighter and one-third the cost" are available from Atlas International
Building Products, 5600 Hochelaga St., Montreal, Quebec, Canada H1N
1W1. [$180/square loose or $400./sq. installed, 30-year guarantee.]
- Supra-Slate "looks like slate and is manufactured in colors
of real quarry slate." Tegusol is a double interlocking clay roof
tile. Available from: Supradur Manufacturing Corporation, PO Box 908,
Rye, NY 10580 800/223-1948 or 914/967-8230. or 122 East 42nd St.,
NY, NY 10168 212/697-1160
- Lifetile(R) Boral Concrete Products, Inc., produces high
density extruded concrete roofing tiles meeting Class "A" requirements.
Dallas, TX 214/544-2227
- Listing submissions are welcome from websites whose content, services, or products are appropriate for our readers. To provide your link exchange information and our link exchange policy see InspectAPedia.com - Directory Listing & Link Exchange Instructions There are no listing fees & no conflicts of interest. We reserve the right to list or not list individuals or companies and to provide notice of consumer compliments or complaints. The design and content found at InspectAPedia.com® are © Copyright protected, All Rights Reserved. Contents of this website may not be copied in any form. our main website topics listed at page top or at Related Topics provide in-depth, un-biased, expert information on building defect inspection,
diagnosis, & repair.
...
Frequently Asked Questions (FAQs) about where to buy slate roofing tools, supplies, repair devices, slate hooks, slate rippers, slate hammers
...
Ask a Question or Search InspectApedia
Questions & answers or comments about buying roofing slate & slate roofintgools.
Ask a Question or Enter Search Terms in the InspectApedia search box just below.
Technical Reviewers & References
Related Topics, found near the top of this page suggest articles closely related to this one.
- [1] Alan Carson and Dan Friedman are ASHI Members, home inspectors, educators and writers in Toronto and Poughkeepsie respectively. Information
in this article is taken from the references shown below, from inspection experience, from opinions shared at ASHI and other education seminars,
from the authors' personal, limited experience repairing and rebuilding of slate roofs, and from very helpful Bill Markcrow and Doug Sheldon
at Vermont Structural Slate Co.
We also paraphrased from a presentation to NY Metro ASHI Members by Mr. Steven Trapasso in October, 1990.
Mr. Trapasso has 40 years experience in working with slate, and has a clear love affair with the material, particularly when it comes
from Vermont.
- [2] Slate Roofs, National Slate Association, 1926, reprinted 1977
by Vermont Structural Slate Co., Inc., Fair Haven, VT 05743, 802-265-4933/34. (We recommend this book if you can find it. It
has gone in and out of print on occasion.)
- [3] The Slate Roof Bible, Joseph Jenkins, www.jenkinsslate.com,
143 Forest Lane, PO Box 607, Grove City, PA 16127 - 866-641-7141 (We recommend this book).
- [4] Slate Roofs , Steven Trapasso, presentation to NY Metro
ASHI, Inc. chapter seminar, November 1990.
- [5] John Stortz & Son Inc, 210 Vine St., Philadelphia, PA 19106. Website: www.stortz.com, Tel: 888-847-3456 or 215-627-3855. Stortz has been producing and selling hand tools since 1953. The company's slate roofing tools include slate cutters, hammers,slate rippers, slaters stakes, slate hooks (see our article on SLATE ROOF REPAIRS), a power slate cutter, and other tools.
- [6] The Old-House Journal , Special Roof Issue , April
1983, The Old-House Journal, PO Box 50214, Boulder, CO 80321-0214
- [7] National Slate Technology Center courses for architects, builders, etc.
- [8] Handbook of Building Crafts in Conservation, Jack Bower, Ed.,
Van Nostrand Reinhold Company, NY 1981 ISBN 0-442-2135-3 Library of
Congress Catalog Card Nr. 81-50643.
- [9] Slate Roofing Contractors Association of North America
- [10] National Slate Association includes list of slate testing laboratorie
Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. (416) 964-9415 1-800-268-7070 info@carsondunlop.com. The firm provides professional home inspection services & home inspection education & publications. Alan Carson is a past president of ASHI, the American Society of Home Inspectors. Thanks to Alan Carson and Bob Dunlop, for permission for InspectAPedia to use text excerpts from The Home Reference Book & illustrations from The Illustrated Home. Carson Dunlop Associates' provides:
- Commercial Building Inspection Courses - protocol ASTM Standard E 2018-08 for Property Condition Assessments
- Home Inspection Education Courses including home study & live classes at eleven colleges & universities.
- Home Inspection Education Home Study Courses - ASHI@Home Training 10-course program.
Special Offer: Carson Dunlop Associates offers InspectAPedia readers in the U.S.A. a 5% discount on these courses: Enter INSPECTAHITP in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.
- The Home Reference Book, a reference & inspection report product for building owners & inspectors.
Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.
- The Home Reference eBook, an electronic version for PCs, the iPad, iPhone, & Android smart phones.
Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter inspectaehrb in the order payment page "Promo/Redemption" space.
- The Illustrated Home illustrates construction details and building components, a reference for owners & inspectors.
Special Offer: For a 5% discount on any number of copies of the Illustrated Home purchased as a single order Enter INSPECTAILL in the order payment page "Promo/Redemption" space.
- The Horizon Software System manages business operations,scheduling, & inspection report writing using Carson Dunlop's knowledge base & color images. The Horizon system runs on always-available cloud-based software for office computers, laptops, tablets, iPad, Android, & other smartphones.
- [11] How to Inspect & Repair Slate Roofs a detailed article about evaluating the condition of slate roofing and repairing worn or damaged slate roofs.
- [12] Slate Roof Photo Library photographs of colors, types, patterns of slate roofs, slate roof wear, slate roof conditions.
- [13] Slate References page from the ASHI Technical Journal
- [14] Slate Sources, Repairs page from the ASHI Technical Journal
- [15] Roofing: Defect Recognition, Repair, Prevention for Roofing & Flashing main web page
- [16] Inspecting and Evaluating Slate Roofs Hudson Valley ASHI seminar content
- [17] Choosing a Roofing Contractor How to find and select a roofing contractor - (thanks to Jessie Schrader)
- [18] Slate Roofs, National Slate Association, 1926, reprinted 1977
by Vermont Structural Slate Co., Inc., Fair Haven, VT 05743, 802-265-4933/34. (We recommend this book if you can find it. It
has gone in and out of print on occasion.)
- [19] The Slate Roof Bible, Joseph Jenkins, www.jenkinsslate.com,
143 Forest Lane, PO Box 607, Grove City, PA 16127 - 866-641-7141 (We recommend this book).
- [20] Slate Roofs , Steven Trapasso, presentation to NY Metro
ASHI, Inc. chapter seminar, November 1990.
- [21] The Old-House Journal , Special Roof Issue , April
1983, The Old-House Journal, PO Box 50214, Boulder, CO 80321-0214
- [22] National Slate Technology Center courses for architects, builders, etc.
- [23] Slate Roofing Contractors Association of North America
- [24] National Slate Association includes list of slate testing laboratories
- [25] Historic Slate Roofs : With How-to Info and Specifications, Tina Skinner (Ed), Schiffer Publishing, 2008, ISBN-10: 0764330012
, ISBN-13: 978-0764330018
- [26] Problems in Roofing Design, B. Harrison McCampbell, Butterworth Heineman, 1991 ISBN 0-7506-9162-X (available used)
- [27] Roofing The Right Way, Steven Bolt, McGraw-Hill Professional; 3rd Ed (1996), ISBN-10: 0070066507, ISBN-13: 978-0070066502
- [28] Slate Roofs, National Slate Association, 1926, reprinted 1977
by Vermont Structural Slate Co., Inc., Fair Haven, VT 05743, 802-265-4933/34. (We recommend this book if you can find it. It
has gone in and out of print on occasion.)
- [29] Roof Tiling & Slating, a Practical Guide, Kevin Taylor, Crowood Press (2008), ISBN 978-1847970237,
If you have never fixed a roof tile or slate before but have wondered how to go about repairing or replacing them, then this is the book for you. Many of the technical books about roof tiling and slating are rather vague and conveniently ignore some of the trickier problems and how they can be resolved. In Roof Tiling and Slating, the author rejects this cautious approach. Kevin Taylor uses both his extensive knowledge of the trade and his ability to explain the subject in easily understandable terms, to demonstrate how to carry out the work safely to a high standard, using tried and tested methods.
This clay roof tile guide considers the various types of tiles, slates, and roofing materials on the market as well as their uses, how to estimate the required quantities, and where to buy them. It also discusses how to check and assess a roof and how to identify and rectify problems; describes how to efficiently "set out" roofs from small, simple jobs to larger and more complicated projects, thus making the work quicker, simpler, and neater; examines the correct and the incorrect ways of installing background materials such as underlay, battens, and valley liners; explains how to install interlocking tiles, plain tiles, and artificial and natural slates; covers both modern and traditional methods and skills, including cutting materials by hand without the assistance of power tools; and provides invaluable guidance on repairs and maintenance issues, and highlights common mistakes and how they can be avoided.
The author, Kevin Taylor, works for the National Federation of Roofing Contractors as a technical manager presenting technical advice and providing education and training for young roofers.
- [30] The Slate Roof Bible, Joseph Jenkins, www.jenkinsslate.com,
143 Forest Lane, PO Box 607, Grove City, PA 16127 - 866-641-7141 (We recommend this book).
- [31] Slate Roofing in Canada (Studi4es in archaeology, architecture, and history),
- [32] Smart Guide: Roofing: Step-by-Step Projects, Creative Homeowner (Ed), 2004, ISBN-10: 1580111491, ISBN-13: 978-1580111492
- [33] Solar heating, radiative cooling and thermal movement: Their effects on built-up roofing (United States. National Bureau of Standards. Technical note), William C Cullen, Superintendent of Documents, U.S. Govt. Print. Off (1963), ASIN: B0007FTV2Q
Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair
The Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.
Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.
|
- Building Pathology, Deterioration, Diagnostics, and Intervention, Samuel Y. Harris, P.E., AIA, Esq., ISBN 0-471-33172-4, John Wiley & Sons, 2001 [General building science-DF] ISBN-10: 0471331724
ISBN-13: 978-0471331728
- Building Pathology: Principles and Practice, David Watt, Wiley-Blackwell; 2 edition (March 7, 2008)
ISBN-10: 1405161035
ISBN-13: 978-1405161039
- Handbook of Building Crafts in Conservation, Jack Bower, Ed.,
Van Nostrand Reinhold Company, NY 1981 ISBN 0-442-2135-3 Library of
Congress Catalog Card Nr. 81-50643.
- Historic Preservation Technology: A Primer, Robert A. Young, Wiley (March 21, 2008)
ISBN-10: 0471788368
ISBN-13: 978-0471788362
- ...
|