State water heater serial number - age decoder:
Details of how to de-code water heater age for State water heaters & where to find State water heater manuals.
We give contact information for State-brand water heater, geyser, cylinder, calorifier manufacturers and for water heater installation, operation, & troubleshooting manuals.
Page top photo: A State 20 gallon water heater model ES6-20-SOMT-K.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
This page decodes the age of State brand water heaters. If your water heater or water tank is a different brand see
WATER HEATER AGE & MANUALS - home for water heaters, calorifiers, geysers, hot water cylinders
or
WATER PUMP & TANK I&O & REPAIR MANUALS - home for water tank and pump manuals & age decoders
State water heaters, produced by State Industries, encode the age in the first three positions of the State water heater serial number as
MYYnnnn
Where M is a one-letter month code, encoded corresponding to A = January through M = December and the second two digits are the numeric year.
On some State water heaters, age is encoded in the first four positions of the State or Apollo Comfort Products Water Heater serial number as
MMYYnnnnn such as 0910123456 where the heater was made September 2010.
Note that I've seen some guides claiming the opposite encoding, that is YYMMnnnnn
Other water heater brands by State or using the same format include Apollo Comfort Products water heaters.
Ace Water Heaters, Ambassador water heaters, Apollo Comfort Products water heaters, Arco water heaters, Barnett water heaters, Century water heaters, Crosley water heaters,
Energy Stretcher water heaters, Freedom water heaters, Hardware House water heaters, Intertherm water heaters,
Kenmore water heaters,
Master Plumber water heaters, Master Plumber True5 water heaters, Mission water heaters, National line Water heaters, also Nationaline water heaters,
Nordyne water heaters,
Patriot water heaters, Penfield water heaters, President water heaters, Regency water heaters, Reliance water heaters,
Sears water heaters, State Industries, State water heaters, The Plumbery water heaters, Thermo-king water heaters, Top Line water heaters
Other State water heater manuals including heat pumps, elecronic display &c are listed at
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
@Daniel Snyder,
The State Scout brand water heaters are compact models - you can read a product description and model numbers in this document
STATE SCOUT COMPACT WATER HEATER SPECIFICATIONS [PDF] (2011) State Water Heaters, 500 Tennessee Waltz Parkway, Ashland City, TN 37015 USA
800 365-0024 Toll-free USA Web: www.statewaterheaters.com
On 2022-12-30 by Daniel Snyder
I’m trying to research a WH that appears to have called it quits. It’s a State Scout. Mdl#SHN50DORTE5
On 2022-08-24 by InspectApedia (mod)
@Ty,
The State water heater serial number decoding information above on this page would indicate that your date would be January of 2000.
On 2022-08-24 by Ty
Trying to confirm the age of my water heater. The s/n doesn’t follow any provided so my inspection report indicates it is 22 years old (based on 00 in s/n of A00114092). It looks brand new so trying to confirm if it could be newer for insurance company. Plate image attached.
@GARY,
Knowing the serial number of your water heater as you do, you can use the decoding age information that is specifically described above on this page. Please do take a look.
On 2022-02-07 by GARY
Need to know the year/age of this water heater -model# p6401ortgw - serial# j00151635 - state select heater - thanks
On 2021-11-23 by Inspectapedia Com Moderator
@state select 40 gal ,
The State water heater age decoding information is exactly described above on this page. Please do take a look, after first noting the actual serial number of your heater.
On 2021-11-23 by state select 40 gal
where does it show the age of the water heater
On 2021-08-03 by inspectapedia.com.moderator (mod)
@BarbaraBecker,
That Statecwster heater serial number exactly fits the age decoding scheme that's given at the top of this page. Please take a look.
On 2021-08-02 by BarbaraBecker
How to find out age of electrical hot water heater made by State Industrial #K98224552?
On 2021-05-06 by Harold Sakayan
What is the age of this State Select water heater - ES650DORSG
@GIO,
To determine the "year" (of manufacture) and thus the age of your water heater
1. look at the water heater to identify the manufacturer or brand
2. find the data tag on the water heater: that will contain a lot of information including the water heater serial number and model name
3. At InspectApedia.com find the water heater age decoder for your brand of water heater by using the on-page search box - for example search for
STATE WATER HEATER AGE
(which would bring you to this page)
Now on this page read the page top about how to de-code or find the "age" encoded in the serial number for your water heater.
On 2021-03-16 by GIO
How do I determine the year of the hotwater tank
Don
Let's hop over to NOISE, WATER HEATER - where we describe different noises and offer some diagnostics;
Could be a burner issue (unsafe)
or
scale deposits
or of course
something else
On 2020-10-19 by dons@shotbe.com
Water heater is making a lot of noise when the gas kicked on again after taking a bath. No lealage from tank. I shut off the gas and the noise quit. Serial number G83652665. Model CV 40 NRT2 State Courier Mfg. Sounded like it came from the burner area.
On 2020-07-13 by mc guire plumbing
need age of a state water heater j07m005818
On 2020-04-18 - by (mod) -
Anon
To find out if your State water heater is still covered by its warranty you need
- to find the age of your water heater (it's encoded in the serial number as we explain above on this page)
- to find the specific warranty terms that State provided with your water heater to read the warranty period
This link gives access to State Water Heater Warranties for the company's broad line of heaters.
https://www.statewaterheaters.com/support/warranty-information/
Here is a representative STATE RESIDENTIAL WATER HEATER WARRANTY [PDF] https://inspectapedia.com/plumbing/State-Water-Heater-Residential-Warranty.pdf
On 2020-04-18 by Anonymous
How do I find out if my State water heater is still under warranty?
On 2020-01-04 - by (mod) -
Not sure
Perhaps Nov 1991?
On 2019-12-29 by William Johnson
What year is this number serial # k91119364
On 2019-05-20 - by (mod) -
Cecil,
at WATER HEATER AGE DECODING GUIDES
where we list age decoders for just about every water heater made,
you will find the age decoder JETGLAS WATER HEATERS
On 2019-05-20 by cecil lockyer
I have a jet glass h2o heater serial # lf3337645 built at amber pa..
how old is it?
On 2019-05-14 - by (mod) -
Serial #C07JO57511
quite possibly C = month and 07 = year
where C = March
On 2019-05-14 by Dianne Hilburn
Trying to find out age of water. Serial #C07JO57511, MODEL #ECT-52-200
On 2019-03-02 by hardee
what is the mfg. date for state water heater model # enc -40 -dors -!10 ser # 1836111818661
On 2016-07-01 by (mod) re: water heater tank liner affects heater life
Alan, Certainly the quality of liner of a water heater is an important factor in heater life; other factors include volume of water usage, water chemistry, and water temperature, installation details, and maintenance.
On 2016-07-01 by Alan Evans
Bought a house with 33 year old State water heater. I have been told State made a ceramic lined water heater, can this be why my 33 year old heater is still working fine? Model CV40NRT4
Serial # F86149261
...
Continue reading at WATER HEATER LIFE or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
STATE WATER HEATER AGE & MANUALS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Questions & answers or comments about how to find out the age of a heating appliance: water heater, heating boiler, heating furnace.
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.