Water supply piping connection: copper to galvanize (C) Daniel FriedmanBrass Water Supply Piping Inspection, Diagnosis, Repair, Replacement, Life Expectancy

  • BRASS WATER PIPES - CONTENTS: Inspecting, Installing, Repairing, & Diagnosing Brass Water Pipe Problems. Brass water supply piping inspection, diagnosis, repair. Life expectancy of Brass water supply pipes. Types of pipe fittings & connections used with brass water pipes in buildings
  • POST a QUESTION or READ FAQs about brass plumbing pipes & fittings
  • REFERENCES
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

Brass pipes:

This page lists our in-depth articles on inspecting, testing, and repairing problems with brass water supply plumbing. Our page top photograph shows a great place to look for brass piping: in the plumbing access behind the tub wall of an older home.

This photograph was taken in a home built in Poughkeepsie, NY in 1935. We found brass water supply pipes, brass drain piping, lead drain pipes, and asbestos pipe insulation all in this opening.

The articles at this website will answer most questions about water supply & drain piping, wells, & water tanks as well as many other building plumbing system inspection or defect topics. Reproduction of this web page electronically at other websites is prohibited.



Green links show where you are. © Copyright 2017 InspectApedia.com, All Rights Reserved.

Brass Building Water Supply: how to identify, inspect, repair, replace

Brass water piping (C) Daniel Friedman

Distinguishing Brass Water Pipes from Copper Piping

Watch out: on older buildings brass water supply piping may have been used, and may be at or near the end of its useful life.

It can be tricky to tell the difference between brass water supply piping and copper water supply piping if you are not experienced with these materials, as their colors are similar, especially when both types of piping have become an oxidized brownish color with age.

Both brass and copper are non-magnetic, so they won't respond to a "magnet" test to look for iron or steel.

Brass water supply piping, unlike copper, is a thicker material that is usually joined by threaded fittings of the same size and pipe thread specifications (NPT) as iron and galvanized iron piping.

Usually, brass piping is also so rigid that it is not bendable. Or not very bendable anyway. So in our photograph (left) of water supply piping at a bath tub in an older home, the larger-diameter left-hand pipe is surely brass, connected to a galvanized iron fitting at its bottom end.

The right-hand vertical pipe may be copper tubing as is the darker copper pipe at left behind our brass one.

Don't worry about that odd little machine in bottom center of the photo - we were collecting an air sample in this wall cavity.

More Photographs of Brass Water Supply Piping

Brass water pipe (C) Daniel Friedman Brass water pipe (C) Daniel Friedman

Our brass pipe photograph at above left helps identify brass water supply piping: the combination of shiny gold-colored metal (scratch it to see), and threaded pipe fittings confirms that the material is brass, not copper. A brass union and brass water pipe fittings in our photo at above right also show the threaded connections characteristic of this material.

Brass water pipe (C) Daniel Friedman

We discuss the lead drain line shown in our above-left photo, at LEAD PIPES in BUILDINGS.

Here we show vintage brass water supply piping rising to a third floor bath tub in an older home.

The water shutoff valve is probably chromed brass, and you can also observe a larger diameter brass tub drain pipe just behind the brass water pipe and valve shown in the foreground.

At the right edge of the photo is a second brass water supply pipe riser, and in the floor we noticed a brass cap over a floor-access plumbing drain access.

Incidentally, from its age, location, and retrofit status, this tub drain did not work very well - it was un-vented.

More recently a plumber had installed a vacuum breaker on this drain line, found in a nearby attic knee wall crawl space.

Life Expectancy of Brass Water Supply Piping

Unlike it's look-alike cousin galvanized iron piping, brass water pipes are less likely to become clogged internally by rust build-up. However if the building water supply is heavy in minerals, mineral deposits, particularly in hot water pipes, can over time clog brass water piping just as it may cause clogs in galvanized iron or copper water pipes.

We often find brass water supply piping working well after more than 50 years and we have inspected and found in good condition brass water supply pipes in buildings more than 75 years old, including some of the photos shown in this article that were obtained in a home built in 1935.

We suspect that the life expectancy of brass water pipes may depend on part on the corrosivity or aggressiveness of the building water supply.

Photos of Brass Drain Piping in Buildings

Brass water pipe (C) Daniel Friedman

Brass drain pipes and on occasion chrome-plated brass drain piping may be more commonly found in buildings than you realize. Lots of plumbing traps and some tub drain parts were made of brass or chrome-plated brass.

This photograph shows brass drain connections at a bath tub. We scratched the horizontal drain connector to better-show its characteristic brass color.

Watch out: even though the brass drain line in this photo appeared to be in good condition with no signs of leaks despite its age, there could be perforations developing on the non-visible underside of the brass pipe.

Worse, in this same location the brass tub drains connected to a lead plumbing drain that will be costly to replace when it leaks.

Supply Piping Articles

...


Continue reading at COMPRESSION FITTINGS or select a topic from closely-related articles below, or see our complete INDEX to RELATED ARTICLES below.

Or see PEX BRASS CONNECTOR LEAKS

Also see Water Supply/Drain Pipe Leak Types

Suggested citation for this web page

BRASS WATER PIPES at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

INDEX to RELATED ARTICLES: ARTICLE INDEX to PLUMBING SYSTEMS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia


...

Frequently Asked Questions (FAQs)

Click to Show or Hide FAQs