InspectAPedia®   -   Search InspectApedia

Bradford White water heater data tag (C) Daniel Friedman InspectApedia.com TucsonBradford White Water Heater Age or Manuals
Bradford White & Superstor & Jetglas Water Heater, Geyser, Cylinder, Calorifier Contacts & Water Heater Manuals

Bradford-White brand Water heater age decoding guide & water heater manual downloads.

We give contact information for Bradford-White water heater, geyser, cylinder, calorifier manufacturing company and for links to manuals for Bradford White water heater installation, operation, & troubleshooting manuals.

This water heater guide works with these brands: Bradford White, JetGlas, and some Superstor.

Our photo at page top shows a data tag on a Bradford-White water heater.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

How to Determine the Age of a Bradford White Water Heater

Bradford White water heater data tag (C) Daniel Friedman InspectApedia.com TucsonPhoto: Data tag details on a Bradford White water heater installed in Tucson, Arizona.

Serial No. DH9477405 decodes to D-2007 and H-August

[Click to enlarge any image]

Bradford White water heater age is encloded as two letters in water heater's serial number as follows:

Current Bradford White water heater date code format: YM234567...

First letter = year of manufacture

Beginning with A = 1964 or A = 1984o r for newer water heaters made after 2003, A = 2004

Ending with Z = 2003 or, for example, M = 2016 etc.

Notes to the Bradford White Water Heater age decoder table above:

Note that the letters I, O, Q, R, U are not used

Second letter = month of manufacture

Later model water heaters may replace letters with an actual year and month encoding as numeric digits.

Beginning with A = January and ending with M = December

Example: Bradford White water heater serial number ZJnnnnnnn = 2003, September

Note: in the month code the company encodes the month in A - M and does not make use of letters I, O, Q, R, U or V)

Jetglas water heaters made by Bradford White use the following date enoding:

YM1234567 encoding the year and month alphabetically using A-M for month (skipping the letter I) and a series of year-series for alphabetic letters.

Table of Bradford White Water Heater Year Codes

Year Code Year of Manuacture
A 1984 or 2004 or [future] 2024
B 1985 or 2005
C 1986 or 2006
D 1987 or 2007
E 1988 or 2008
F 1989 or 2009
G 1990 or 2010
H 1991 or 2011
J 1992 or 2012
I 1993 or 2013
K 1994 or 2014
L 1995 or 2015
M 1996 or 2016
O not used
P 1997 or 2017
Q, R not used
S 1998 or 2018
T 1999 or [future] 2019
U, V not used
W 2000 or [future] 2020
X 2001 or [future] 2021
Y 2002 or [future] 2022
Z 2003 or [future] 2023

...

Table of Bradford White Water Heater Month Codes

Month Code Month of Manuacture
A January
B February
C March
D April
E May
F June
G July
H August
J Septmber
K October
L November
M December

Notes to the table above

Note that to avoid confusion the letter I is not used.

Bradford White Water Heater Brands

Bradford White water heater installed in Port Angeles WA (C) Daniel Friedman at InspectApedia.comBradford White water heaters; also sold as Jetglas water heaters.

The Bradford White water heatr shown in our photo was installed in Port Angeles, Washington in 2011.

Contact Information& Manuals for Bradford White Water Heaters

Bradford White Electric Water Heater Manuals

Bradford White Gas Water Heater Manuals

Bradford White Defender Gas fired water heater with ample combustion air supply in a Poughkeepsie Basement (C) Daniel Friedman -  SmithPhoto: A Bradford White Defender Hydrojet gas water heater with ample combustion air supply, located in a basement utility closet, Poughkeepsie, NY.

Bradford White Indirect Water Heater Manuals

Bradford White Oil Water Heater Manuals


...

Continue reading  at WATER HEATER LIFE or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Recommended Articles

For water pressure tank age or water storage tank age, see WATER TANK AGE DECODER

Suggested citation for this web page

BRADFORD WHITE WATER HEATER AGE & MANUALS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.


Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to WATER HEATERS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Questions & answers or comments about how to find out the age of a heating appliance: water heater, heating boiler, heating furnace.

Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.

Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification
when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca

Comment Form is loading comments...

Citations & References

In addition to any citations in the article above, a full list is available on request.



ADVERTISEMENT