InspectAPedia.com InspectAPedia®

Question? Just ask us!

Google
InspectAPedia

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

  • HOME
  • AIR CONDITIONING
  • DAMAGE ASSESSMENT
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US



InspectAPedia ® Home

OIL STORAGE TANKS

ABANDONING OIL TANKS
AGE of OIL TANK
ANODES & DIP TUBES on WATER HEATERS

BOILERS, HEATING
BURIED OIL TANK ADVICE
BURIED OIL TANKS, FINDING

COMBUSTION PRODUCTS & IAQ

DEFINITION of Heating & Cooling Terms
DIAGNOSE & FIX HEATING PROBLEMS-BOILER
DIAGNOSE & FIX HEATING PROBLEMS-FURNACE
DIRECTORY of OIL TANK EXPERTS

FILTERS, OIL on HEATING EQUIPMENT
FIRE SAFETY CONTROLS
FLOATING UP OIL STORAGE or SEPTIC TANKS
FLOODED HEATING EQUIPMENT REPAIR
FLOODED WATER HEATER REPAIR
FUEL OIL TYPES & CHARACTERISTICS
FUEL UNIT, HEATING OIL PUMPS

GALVANIC SCALE & METAL CORROSION
GAUGES ON HEATING EQUIPMENT

HEAT TAPES, Heat, Insulation prevent Freeze-Up
HEATING COST FUEL & BTU Cost Table
HEATING COST SAVINGS METHODS
HEATING OIL CLOUD WAX GEL POINT
HEATING OIL EXPOSURE HAZARDS, LIMITS
HEATING OIL - OLD, USEABLE?
HEATING OIL PIPING TROUBLES
HEATING OIL SHELF LIFE
HEATING OIL SLUDGE
HEATING OIL TANKS
HEATING OIL TYPES & PROPERTIES
HEATING OIL USAGE RATE
HEATING SYSTEM NOISES
HOME BUYERS GUIDE TO OIL TANKS

NOISE CONTROL for HEATING SYSTEMS
NOISES COMING FROM WATER HEATER

ODORS & SMELLS DIAGNOSIS & CURE
ODORS FROM HEATING SYSTEMS
OIL BURNERS
OIL FILTERS on HEATING EQUIPMENT
OIL FUEL TYPES & CHARACTERISTICS
OIL ODORS, LEAKY OIL TANK PIPING
OIL SPILL CLEANUP / PREVENTION
OIL TANKS

SOOT on OIL FIRED HEATING EQUIPMENT
STAIN DIAGNOSIS on BUILDING INTERIORS

THERMAL TRACKING & HEAT LOSS

VIDEO GUIDES: Heating System Videos
VIDEO GUIDES - InspectAPedia.com

WATER HEATERS
WINTERIZE A BUILDING

More Information

Heating Oil Underground & Above ground Oil Storage Tank Home Buyer's / Home Owner's Guide
Oil Storage Tank Leak Testing Options and Test Companies
     

  • What types of oil storage tank leak tests are available
    • What are the pros and cons of alterative methods of testing for oil tank leaks?
  • Questions & Answers about choosing among oil tank leak testing methods
  • References

Click to Show or Hide Related Topics

  • OIL TANKS - home
  • OIL FUEL TYPES & CHARACTERISTICS
  • OIL LINE CLOGGING FIX
  • OIL LINE QUICK STOP VALVES
  • OIL LINE SAFETY VALVES
  • OIL ODORS, LEAKY OIL TANK PIPING
  • OIL SPILL CLEANUP / PREVENTION
  • OIL TANK ABANDONING PROCEDURE
  • OIL TANK AGE
  • OIL TANK, BURIED, ADVICE
  • OIL TANK, BURIED, FINDING
  • OIL TANK FAILURE CAUSES
  • OIL TANK FAILURE RATES
  • OIL TANK FLOATING UP
  • OIL TANK GAUGES
  • OIL TANK INSPECTION, ABOVE GROUND
  • OIL TANK INSPECTION REPORTS
  • OIL TANK LEAKS & SMELLS - home
    • OIL TANK LEAK ENVIRONMENTAL ISSUES
    • FREQUENCY of OIL TANK LEAKS
    • HOME INSPECTOR OIL TANK REPORT
    • OIL LINE LEAKS & OIL TANK FILL PIPE LEAKS
    • OIL TANK LEAK IMPACTS
    • OIL TANK LEAK CAUSES
    • OIL TANK LEAK CLEANUP GUIDE
    • OIL TANK LEAK REPORTING REGULATIONS - ALL
    • OIL TANK REGULATIONS - CANADA
    • OIL TANK LEAK REPORTING in NEW JERSEY
    • OIL TANK LEAK & SIZE REPORTING
    • OIL TANK LEAK TESTING
  • OIL TANK LIFE
  • OIL TANK PIPING & PIPING DEFECTS - home
  • OIL TANK PRESSURE
  • OIL TANK REGULATIONS
  • OIL TANK REMOVAL COs
  • OIL TANK REMOVAL FINANCIAL AID
  • OIL TANK SAFETY
  • OIL TANK SLUDGE
  • OIL TANK SPILL CLEANUP / PREVENTION
  • OIL TANK STANDARDS
  • OIL TANK SUPPORT
  • OIL TANK TESTING COMPANIES
  • OIL TANK TESTING METHODS
  • OIL TANK WATER CONTAMINATION
  • OIL TANK WATER REMOVAL
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

Guide to types of oil storage tank leak tests available: this article discusses the types of oil storage tank tests that may be performed on buried oil tanks and above ground oil storage tanks to check for leaks or imminent leaks. Not all storage tank tests are equal in accuracy nor cost, and some are more appropriate than others, depending on other factors. We include a listing of oil and fuel storage tank testing companies and services, and invite (no-fee) listings from other companies providing that service. Many storage tank testing companies also offer storage tank removal and site cleanup services as well.

Green links show where you are. © Copyright 2013 InspectAPedia.com, All Rights Reserved. Author Daniel Friedman.

Guide to Oil Storage Tank Testing: Oil Tank Inspection and Oil Leak Testing Choices

This is a chapter of our "Heating Oil Underground & Above ground Oil Storage Tank Leaks, Testing, Problems & Solutions, Home Buyer's / Home Owner's Guide" which offers extensive free un-biased oil storage tank inspection and testing advice for property buyers and owners. Qualified service providers may be listed at this website at no fee.

Home buyers should be sure to review OIL TANK TESTING - Leaky Heating Oil Tanks - How Oil Tanks are Tested for Evidence Leaks, of Current or Previous Oil Spills and OIL TANK LEGAL ISSUES - Home Buyers and Home Owners Guide to Leaky Heating Oil Tanks - What to Do About & When to Report Oil Tank Leaks. Leaky Heating Oil Tanks.

Home owners who have old oil tanks above ground or any age oil tank below ground should also be sure to review OIL TANK ABANDONING PROCEDURE - Abandoning Commercial vs. Residential Underground Oil Storage Tanks (UST) - Procedures & Regulations A separate website addresses Septic Tanks.

Look for yourself: Before deciding to hire a tank testing company for professional inspection and testing, some basic information such as the age (property and tank), tank location, and type of oil tank, and for above-ground tanks, a simple visual inspection of the tank and its piping, can give you and idea of the risks involved. Look for obvious leaks such as oil stains on the ground or floor under or around the tank and around the oil fired equipment. Remember to look under the oil tank at its bottom, as most leaks occur in the lower portion of the tank.

Hire an expert: Specialty companies and some oil companies have equipment to test buried tanks for leaks. Soil testing, simple low-psi pressure-testing and sophisticated electronic testing are commonly used. I advise home buyers to have a soil test performed rather than a pressure test of an existing oil tank, since even if the tank is not currently leaking we would prefer an assurance that it didn't leak before, say from a plumbing connection that was repaired.

In addition to oil tank inspection, oil piping inspection, and oil tank testing to "pass" or "fail" an oil storage tank, more sophisticated tests are available to assess the chances that an existing heating oil storage tank has leaked or is likely to have a serious leak soon. These include a oil tank corrosion analysis which adds to the basic tank inspection and tests an assessment of the level of corrosion of the tank walls and thus the chances of its leaking or failure, and soil corrosion or soil corrosivity evaluation which includes an evaluation of soil samples collected from around the tank in order to assess the degree to which the soil in which the oil tank has been buried will contribute to the process of corrosion of the (presumably steel) buried oil tank.

Testing for water in an oil tank (above ground or buried) is simple and can be done by any service person. Tank testing methods vary in risk to the tank, cost, invasiveness, length of time to complete, and more.

From a previous use, a buried oil tank may be present or may have been present at a property now served by an indoor, above ground oil tank or even by LP or natural gas. So don't assume that because you don't see a tank that none was ever used or present at a property.

OIL TANK LEAK TESTING COs / OIL TANK REMOVAL COs - Oil Tank Testing, Removal, Consulting Environmental Service Companies

  • CT: Enviro Tech of Fairfield County oil tank testing and locating services, Connecticut
  • CO: Tank Specialists, Far West Assoc, Colorado, Wyoming, S. Nevada, S., Baja CA
  • NY: Dorson Environmental Management, Inc., 45 Knollwood Rd., 3rd Fl., Elmsford NY 10523: 914-592-3117
  • OH: CTL Engineering, Inc., Columbus OH (HQ) - UST Management, Testing, Inspection, Analysis: 614-276-8123 614-276-6377 FAX.
    ctl@ctleng.com Offices in NC, OH, WV, VA [Thanks for website support]
  • Jay Hodgens,P.E., Hodgens Engineering Service, Rapid City, SD 57702. Email: james@hodgens.net, for assistance with links and references to regulations regarding underground storage tanks as well as comments on other topics. Mr. Hodgens has been licensed as a professional engineer in eight states and has developed over 450 SPCC plans in compliance with reguilations in twelve states. Mr. Hodgens can be reached at 845-496-0494 or in South Dakota at 605-350-4367. His proposed amendments to US EPA 40 CFR part 112 can be read at http://www.hodgens.net/hes/10-07comments.pdf. 4/1/2013. Mr. Hodgens is a frequent contributor to InspectAPedia.com.
  • VA: Virginia Geotechnical Services, P.C. Email: W. Jerrold Samford, P.G.
  • Mediation, Environmental Dispute - KMG
  • Disposal, Hazardous Waste, SET Home Pg
  • Sound Pictures of Stored Waste
  • Tank / other Env Services Braun-Intertec (C)trap
  • Tank / other Env Services ENSCI Southeast US (C)trap
  • Listing submissions welcome, there is no listing fee. InspectAPedia.com - Directory Listing & Link Exchange Instructions. Add your listing & support InspectAPedia.com by exchanging links - no listing fee & no conflicts of interest.

Frequently Asked Questions (FAQs)

...

Ask a Question or Search InspectApedia

Questions & answers or comments about choosing among oil tank leak testing methods

Ask a Question or Enter Search Terms in the InspectApedia search box just below.

Technical Reviewers & References

Related Topics, found near the top of this page suggest articles closely related to this one.

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • TANK FAILURE CAUSES discusses the causes of oil storage tank leaks in more detail.
  • The rate or frequency of oil tank leaks or oil storage tank failures, focused on underground storage tanks or USTs, is discussed in detail at TANK FAILURE RATES provides Oil Tank Failure Data - Oil Tank Failure Rates - Oil Tank Leak Probability as a Function of Tank Age, Location, Condition, Soil Conditions and Other Factors
  • Listing submissions welcome, there is no listing fee. InspectAPedia.com - Directory Listing & Link Exchange Instructions. Add your listing & support InspectAPedia.com by exchanging links - no listing fee & no conflicts of interest.

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson DunlopThe Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.

    Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.
  • ...
HOME ABOUT CONTACT COPYING DESCRIPTION POLICIES PRINTING PRIVACY © 2013 Copyright InspectAPedia.com