Mold concentration bursts impact on airborne mold count results:

Here we explain what Mold Concentration Bursts are and how mold concentration bursts cause Error in Mold Tests when Air Sampling. This document is a brief tutorial which provides information about the accuracy of and sources of errors in tests for the level of allergenic and toxic mold in residential buildings:

Are spore counts valid? Are mold culture tests and mold swab tests valid? These critical questions are discussed in this article series.

We also provide a MASTER INDEX to this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need.

Concentration Bursts of Mold Spores Cause Variation in Indoor or Outdoor Mold Level Counts

ACGIH Bioaerosols: Assessment and Remediation states [section 1.2.3]:

Some organisms and sources release aerosols as 'concentration bursts' which may only rarely be detected by limited grab sampling and may be masked in measurements of long-term average concentrations. Nevertheless, such episodic bioaerosol releases may produce significant health effects. -- thanks to S. Flappan for suggesting this citation.

Spores are not always airborne during sampling: Mold spores may not be in interior air at the time of the sample but may be present in high levels at other times. Particle level in air varies very continuously as a function of temperature, humidity, size, mechanical disturbance, HVAC operation, use of fans and vacuum cleaners, and other factors as simple as foot traffic through a building.

Concentration bursts of mold spores: An example of a concentration burst of Aspergillus sp. spores occurred during our inspection and monitoring of a college library with many moldy books in its basement. Initially, though there was a large area of visible green mold (Aspergillus sp.) on many books on shelves in the library basement, while conditions there were still quite damp (humidity 65-75% RH) the airborne Aspergillus sp. spore levels were rather low.

But when the college brought in an "expert" who installed commercial dehumidifiers (without cleaning or removing the mold) the airborne Aspergillus sp. skyrocketed. As the humidity dropped the fungus responded by releasing spores.

...


Continue reading at ACCURACY OF VARIOUS MOLD TEST METHODS or select a topic from closely-related articles below, or see our complete INDEX to RELATED ARTICLES below.

Or see AIR TEST FOR MOLD: ACCURACY

Suggested citation for this web page

CONCENTRATION BURSTS of MOLD SPORES at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

INDEX to RELATED ARTICLES: ARTICLE INDEX to MOLD CONTAMINATION & REMEDIATION

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia


...

Frequently Asked Questions (FAQs)

Click to Show or Hide FAQs

Ask a Question or Search InspectApedia

Use the "Click to Show or Hide FAQs" link just above to see recently-posted questions, comments, replies, try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

HTML Comment Box is loading comments...

Technical Reviewers & References

Click to Show or Hide Citations & References

Publisher's Google+ Page by Daniel Friedman