InspectAPedia ® Home EXTERIORS of buildings ADHESIVES, EXTERIOR CONSTRUCTION AGE of a BUILDING - how to determine ALGAE, FUNGUS, LICHENS, MOSS ANIMAL ENTRY POINTS in buildings ARCHITECTURE & BUILDING COMPONENT ID BARK SIDE UP on DECKS & STEPS BASEMENT WATERPROOFING BRICK STRUCTURAL WALL Loose Bulged BRICK VENEER WALL Loose, Bulged BRICK WALL DRAINAGE WEEP HOLES BOOKSTORE - EXTERIORS CARPENTER ANTS CARPENTER BEES CATCH BASINS CAULK GUN TYPES, CHOICES CAULKS & SEALANTS, EXTERIOR CHIMNEY INSPECTION DIAGNOSIS REPAIR DECK & PORCH CONSTRUCTION DECK FINISHES COATINGS PRESERVATIVES DRYWELLS, FRENCH DRAINS for FLAT SITES EIFS & STUCCO EXTERIORS EXTERIOR WALL SIDING TRIM & FINISHES EXTRACTIVE BLEEDING STAINS FLASHING ROOF-WALL SNAFU FOUNDATION WATERPROOFING FRENCH DRAINS GALVANIC SCALE & METAL CORROSION GLUES ADHESIVES, EXTERIOR CONSTRUCTION GRADING, DRAINAGE & SITE WORK GUTTERS & DOWNSPOUTS HOUSE PARTS, DEFINITIONS HOUSEWRAP / SHEATHING WRAP HOUSEWRAP INSTALLATION DETAILS HOUSEWRAP PRODUCT CHOICES HOUSEWRAP at SILLS, SOLES, TOP PLATES ICE DAM PREVENTION INSECT INFESTATION / DAMAGE LEAD POISONING HAZARDS GUIDE LOG HOME GUIDE LIGHTNING PROTECTION OIL TANKS PAINT & STAIN GUIDE, EXTERIOR PAINT & STAIN LIFE CHART PAINT & STAIN SELECTION & PROCEDURES PAINT ANALYSIS, DIAGNOSTIC USES PAINT FALURE, DIAGNOSIS, CURE, PREVENTION PAINT FAILURE DICTIONARY PAINT LAB SAMPLE PREPARATION PAINT SURFACE PREPARATION PAINTING MISTAKES PORCHES & Sunrooms PORCH CONSTRUCTION & SCREENING RAILINGS, DECK & PORCH RAILINGS, STAIRWAY RETAINING WALL DESIGNS, TYPES, DAMAGE RETAINING WALL GUARD RAILINGS ROOF CLEANING RECOMMENDATIONS ROT RESISTANT LUMBER SHEATHING, Gypsum board Sheathing Celotex Homasote & Other SHEATHING, OSB SHEATHING, Plywood SHEATHING, FOIL FACED - VENTS SIDING TYPES, INSTALLATION, DEFECTS SINKHOLES, WARNING SIGNS STAIN DIAGNOSIS on BUILDING EXTERIORS STAIN DIAGNOSIS on ROOFS STAIN DIAGNOSIS on STONE STAIRS, RAILINGS, LANDINGS, RAMPS STONE CLEANING METHODS STONE VENEER WALLS STUCCO WAll FAILURES DUE TO WEATHER STUCCO WALL METHODS & INSTALLATION STUCCO OVER FOAM INSULATION STUCCO PAINT FAILURES SURFACE GRADING, SITE DRAINAGE TERMITES Thermal Expansion Cracking of Brick TREES & SHRUBS, TRIM OFF BUILDING TRIM, EXTERIOR CHOICES, INSTALLATION VINYL SIDING VINYL Siding or PLASTIC Window ODORS WATER BARRIERS, EXTERIOR BUILDING WATER ENTRY in buildings WINDOWS & DOORS ![]() ![]() ![]() More Information |
This article lists significant site drainanage and landscaping defects, definitions, and home inspection education topics. This article series, beginning at BUILDING DEFECTS LISTS, provides lists of common building defects and basic defect knowledge that also outline recommended curriculum content for home inspector education. The building defects and inspection points listed in these articles also guide homeowners and home buyers to building areas that merit careful attention and often point areas of safety concern or important maintenance and repair tasks. Readers should see EXTERIORS of buildings and see WATER ENTRY in buildings for our complete list of articles on this topic. Also see HOME & BUILDING INSPECTORS & INSPECTION METHODS. Use the Search Box at the top or bottom of these pages to find in-depth information about building, energy savings, and indoor environment inspection, diagnosis and repair at this website. Watch out: these inspection lists do not list all possible defects for the systems discussed, and not all home or building inspectors will examine all of the items listed here. CONTACT us to suggest corrections or additions to articles at this website. Green links show where you are. © Copyright 2013 InspectAPedia.com, All Rights Reserved. Author Daniel Friedman. Home Inspection Education Curriculum - Sitework, DrainageThese curriculae and building defect lists are based on smilar curriculum documents first prepared by Joe Scaduto, an ASHI member who prepared course material for Northeastern University's Building Inspection Certificate program in 1988, subsequently by DF, InspectApedia's editor, for New York University ca 1988 and later, with others, recommended to ASHI, the American Society of Home Inspectors. ASHI did not adopt this material though currently that association as well as others offer extensive HOME INSPECTOR EDUCATION material. The curriculum and lists of defects are informed by additional analysis of the process of home inspection that was developed beginning Calgary, AB for Canadian and U.S. home inspector education and certification examinations in 1997. Other early contributors to home inspection education in the U.S. and Canada include Dr. Jess Aronstein, Alan Carson, Mike Casey, Mark Cramer, John Cox, Dwight Barnett, Douglas Hansen, Rick Heyl, Larry Hoytt, Bill Merrill, Kevin O'Malley, Dennis Robitalille, Keith Peddie, Pat Porzio, Roger Robinson. Also see GUTTERS & DOWNSPOUTS and see FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP. Also STAIRS, RAILINGS, LANDINGS, RAMPS 7.3 Site Drainage Inspections: Surface Water Control and Landscaping7.3.1 Knowledge Base for Site Drainage Inspections1. Describe the importance of surface water control and how landscaping may affect homes. 2. Describe these types of roof drainage systems: gutters and downspouts, scuppers, interior drains. 3. Describe the materials/components of gutter and downspout systems, window wells, walkways, patios and driveways, retaining walls. 4. Describe the features of adequate installation and repair technique for lot grading, gutters, downspouts, window wells, walkways, driveways and grounds, and retaining walls. 5. Define the following terms: Swale, catchbasin, foundation drainage layer, gutter, trough, eavestrough, downspout, leader, conductor pipe, ice damming, integral gutter, Yankee gutter, splashblock, scupper, ponding, birdcage, retaining wall (gravity, cantilever, tile, shoring, tie-back, deadman, weephole) 6. Identify the codes or standards which apply to surface water control and landscaping systems in your area. 7.3.2 Inspection Skills for Site Drainage Inspections1. Describe the inspection procedure for lot grading, roof drainage, window wells, walks and driveways, grounds, patios, retaining walls. 2. Identify the common defects listed on the next page. 3. Describe the implications of each defect . 4. Identify safety issues for the inspector and occupant of the house (fall hazard, trip hazard, slip hazard). 5. Communicate findings to client verbally and in writing, recommending corrective action where needed. SURFACE WATER CONTROL & LANDSCAPING TYPICAL DEFECTSOTHER EXTERIOR COMPONENTS BASEMENT STAIRWELLS DEFECTS WINDOW WELLS DEFECTS • Cover inoperable • Damaged • Door threshold missing, • Drains – too low, not watertight • Drains missing, clogged or undersized – Missing • Frost damage – Not connected • Guard and handrail problems – Broken • Insect damage – Obstructed • Leaking • Missing • Paint or stain needed • Rot or wood/soil contact • Rot • Rust • Rust • Step and landing problems WALKS AND DRIVEWAYS DEFECTS • Walls cracking, leaning, bowing or spalling • Cracked or damaged surfaces • Improper slope or drainage LOT GRADING DEFECTS • Uneven (trip hazard) • Clogged catch basins GROUNDS DEFECTS • Improper slope • Porous material • Disturbed ground • Soil erosion • Trees or shrubs too close to house GUTTERS DEFECTS PATIOS DEFECTS • Improper slope • Retaining walls – • Leaking or clogged – Cracks • Loose or damaged – Bulging • Missing – Bowing • Rusted – Drainage system missing • Undersized – Leaning – Deteriorated mortar DOWNSPOUTS – Spalling – Settlement or shifting • Clogged – Rot or insect damage • Damaged • Slip hazards • Downspouts discharging onto roofs • Slope towards house • Downspouts discharging onto the ground • Trip hazards • Downspouts discharging below grade • Leaking GUARDRAILS AND HANDRAILS DEFECTS • Missing • Too few • Damage at bottom • Undersized • Missing or ineffective • low slope JDG • Missing
ROOF DRAINS DEFECTS • Rust • Too low • Clogged • Weak • Drains not at low spots • Leaking RETAINING WALLS DEFECTS • Scuppers missing • Too few drains • Bowing • Undersized • Cracking • Drainage system missing COLUMNS DEFECTS • Leaning • Mortar – deteriorated, missing • Cracking • Rot or insect damage • Heaving • Rusting • Leaning • Settling or shifting • Rusting • Spalling • Settling • Spalling
Readers should see EXTERIORS of buildings and see WATER ENTRY in buildings for our complete list of articles on this topic. Also see HOME & BUILDING INSPECTORS & INSPECTION METHODS. Use the Search Box at the top or bottom of these pages to find in-depth information about building, energy savings, and indoor environment inspection, diagnosis and repair at this website. Watch out: these inspection lists do not list all possible defects for the systems discussed, and not all home or building inspectors will examine all of the items listed here. CONTACT us to suggest corrections or additions to articles at this website. Also see GUTTERS & DOWNSPOUTS and see FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP. Also STAIRS, RAILINGS, LANDINGS, RAMPS Frequently Asked Questions (FAQs) about site drainage designs & problems... Ask a Question or Search InspectApediaUse the search box below to ask a question or to search the InspectApedia.com website. Ask a Question or Enter Search Terms in the InspectApedia search box just below. Technical Reviewers & ReferencesRelated Topics, found near the top of this page suggest articles closely related to this one.
Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair
| |||||||