ALUMINUM ROOFING
AMERICAN CEMWOOD ROOFING
ATTIC VENTILATION

BEST ROOFING PRACTICES
BUILT UP ROOFS

CATHEDRAL CEILING VENTILATION
CEMWOOD ROOFING
CERTIFICATIONS for ROOFING CONTRACTORS
CHIMNEY FLASHING Mistakes & Leaks
COLD WEATHER ROOF TROUBLE

DECKS, ROOFTOP CONSTRUCTION

EPDM, RUBBER, PVC ROOFING
EXTRACTIVE BLEEDING on SHINGLES

FIRE RETARDANT PLYWOOD
FLASHING on BUILDINGS
FLASHING, ASPHALT SHINGLE VALLEYS
FLASHING, CHIMNEY Mistakes & Leaks
FLASHING, CLAY TILE ROOFS
FLASHING MEMBRANES PEEL & STICK
FLASHING for METAL ROOFS
FLASHING ROOF WALL DETAILS
FLASHING ROOF-WALL SNAFU
FLASHING SIDING DETAILS
FLASHING WALL DETAILS
FLASHING WINDOW DETAILS
FLASHING WOOD ROOF DETAILS
FLAT ROOF MOISTURE & CONDENSATION

Green House or Solarium Roof Leaks

HEAT TAPES & CABLES on Roofs for Ice Dams

ICE DAM PREVENTION

MASONITE WOODRUF FIBERBOARD ROOFING

NOISE CONTROL for ROOFS

PLASTIC ROOFING TYPES
PVC, EPDM, RUBBER ROOFING

ROOF ARCHITECTURAL STYLES - PHOTO GUIDE
ROOF CLEANING RECOMMENDATIONS
ROOF COLOR RECOMMENDATIONS
ROOF DORMER TYPES - PHOTO GUIDE
ROOF INSPECTION SAFETY & LIMITS
ROOF JOB PROBLEMS, RESOLVING
ROOF LEAK DIAGNOSIS & REPAIR
ROOF NOISE TRANSMISSION
ROOF REPLACEMENT SNAFUs
ROOFING FELT UNDERLAYMENT REQUIREMENTS
ROOFING MATERIALS, Age, Types
ROOFING TILE SHAPES & PROFILES
ROOFING UNDERLAYMENT BEST PRACTICES

SADDLE CONSTRUCTION at CHIMNEYS
SNOW GUARDS & SNOW BRAKES
STANDARDS for ROOFING
STRESS SKIN INSULATED PANELS

TEST LABS - ROOF SHINGLE
TREES & SHRUBS, TRIM OFF BUILDING
TRUSSES, Floor & Roof

UNDERLAYMENT REQUIREMENTS on ROOFS

VENTILATION in BUILDINGS

WALK-ON ROOF SURFACES
WARRANTIES for ROOF SHINGLES
WORKMANSHIP & ROOF DAMAGE

GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.

More Information

Low slope roof inspection (C) Daniel Friedman Low Slope & Flat Roof Defects List & Home Inspection Education
     

  • DEFECTS LIST - ROOF LOW SLOPE - Low slope or flat roofing inspection recommendations
    • Low slope or flat roof defects list
    • Lists of important defects for residential buildings
    • What does a home inspector need to know? Home inspection training and education curriculum recommendations
  • BUILDING DEFECTS LISTS - separate article
  • DEFECTS LIST - STRUCTURE, ROOF - separate article
  • Questions & Answers about home & building inspection courses, standards, & defect checklists for low slope roofing systems
  • References

Click to Show or Hide Related Topics

  • ROOFING INSPECTION & REPAIR - home
  • AGE OF ROOFING
  • ASBESTOS CEMENT & FIBER CEMENT ROOFS
  • ASPHALT ROOF SHINGLES
  • BEST ROOFING PRACTICES
  • BUILT UP ROOFS
  • CHOOSING A ROOFING CONTRACTOR
  • CLAY TILE ROOFING
  • CONCRETE ROOFING
  • CORRUGATED ROOFING
  • COPPER ROOFING
  • DEBRIS STAINING on ROOFS
  • EPDM, RUBBER, PVC ROOFING
  • EXTRACTIVE BLEEDING on SHINGLES
  • FELT UNDERLAYMENT REQUIREMENTS
  • FIBER CEMENT & FIBERBOARD ROOFING
  • FIRE RATINGS for ROOF SURFACES
  • FLASHING on BUILDINGS
  • HAIL DAMAGED SHINGLES
  • HOT ROOF DESIGNS: Un-Vented Roofs
  • ICE DAM PREVENTION
  • LEAKY ROOF DIAGNOSIS & REPAIR
  • LOW SLOPE ROOFING
  • MEMBRANE & SINGLE PLY ROOFS
  • METAL ROOFING
  • MODIFIED BITUMEN ROOFING
  • PLASTIC ROOFING TYPES
  • PVC, EPDM ROOFING
  • ROLL ROOFING, ASPHALT
  • ROOF SLOPE DEFINITIONS
  • ROOF VENTILATION SPECIFICATIONS
  • RUBBER ROOFING
  • SLATE ROOF INSPECTION & REPAIR
  • SOD ROOFING
  • STAIN DIAGNOSIS on ROOFS
  • STONE ROOFING
  • THATCH ROOFING
  • TILE ROOFING
  • UNDERLAYMENT REQUIREMENTS, ROOF
  • WIND DAMAGE to ROOFS
  • WOOD SHAKE & SHINGLE ROOFING
  • ZINC METAL ROOFING
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

This article lists significant low slope roofing defects, definitions, and home inspection education topics. This article series, beginning at BUILDING DEFECTS LISTS, provides lists of common building defects and basic defect knowledge that also outline recommended curriculum content for home inspector education. The building defects and inspection points listed in these articles also guide homeowners and home buyers to building areas that merit careful attention and often point areas of safety concern or important maintenance and repair tasks. Also see ROOF FLASHING DEFECTS LIST

Green links show where you are. © Copyright 2013 InspectAPedia.com, All Rights Reserved. Author Daniel Friedman.

Home Inspection Education Curriculum - Low-Slope Roofing

Readers should see ROOFING INSPECTION & REPAIR for our complete list of articles on this topic. Also see HOME & BUILDING INSPECTORS & INSPECTION METHODS. Use the Search Box at the top or bottom of these pages to find in-depth information about building, energy savings, and indoor environment inspection, diagnosis and repair at this website. Watch out: these inspection lists do not list all possible defects for the systems discussed, and not all home or building inspectors will examine all of the items listed here. CONTACT us to suggest corrections or additions to articles at this website.

These curriculae and building defect lists are based on smilar curriculum documents first prepared by Joe Scaduto, an ASHI member who prepared course material for Northeastern University's Building Inspection Certificate program in 1988, subsequently by DF, InspectApedia's editor, for New York University ca 1988 and later, with others, recommended to ASHI, the American Society of Home Inspectors. ASHI did not adopt this material though currently that association as well as others offer extensive HOME INSPECTOR EDUCATION material. The curriculum and lists of defects are informed by additional analysis of the process of home inspection that was developed beginning Calgary, AB for Canadian and U.S. home inspector education and certification examinations in 1997. Other early contributors to home inspection education in the U.S. and Canada include Dr. Jess Aronstein, Alan Carson, Mike Casey, Mark Cramer, John Cox, Dwight Barnett, Douglas Hansen, Rick Heyl, Larry Hoytt, Bill Merrill, Kevin O'Malley, Dennis Robitalille, Keith Peddie, Pat Porzio, Roger Robinson.

1.3     Low slope roofing Inspection Recommendations & Defects List

1.3.1 Knowledge Base for Low Slope Roof Inspections

1.    Describe the function of  low slope roofing systems, differentiating them from steep roofing systems.

2.    Describe these common types of  roofing material: built up roofing, modified bitumen, synthetic rubber, plastic roofing, metal roofing, roll roofing, single ply, poly foam

3.    Describe the features of good installation and repair techniques for each of the roofing materials described above.

4.    Outline typical life expectancies for each of the  roofing systems.

5.    Define the following terms: IRMA roof, protected membrane roof, blister, alligatoring, wind scouring, fish mouth, ridging, ponding, rubberized asphalt, standing seam, cant strip, base flashing, counter flashing, through-wall flashing, termination bar, stack jack, pitch pan, internal drains, scuppers, overflow drains.

6.    Describe these common base flashing materials on  low slope roof systems: roofing felts, fabric reinforced asphalt products, modified bitumens, synthetic rubbers, plastics, composition materials.

7.    List three common counter flashing materials on  low slope roof systems (steel, copper, aluminum).

8.    Identify the codes or standards which apply to  low slope roofing in your area.


1.3.2 Inspection Skills for Low Slope Roof Inspections

1.    Describe the inspection procedure for  low slope roof systems.

2.    Identify the following common defects listed on the next page.

3. Describe the implication of each defect .

4. Identify the safety issues for inspectors and occupants of the home (fall hazard and shock hazard).

5.    Communicate findings to client verbally and in writing, recommending corrective action where needed.


LOW SLOPE ROOFING TYPICAL DEFECTS

BUILT-UP Roof Defect List

      • Blisters, alligatoring 

      • Damaged, punctures, tears

      • Debris on roof

      • Discoloration

      • Exposed felts

      • Gravel erosion

      • Leaks

      • Membrane movements, slippage 

      • Multiple layers

      • No gravel, paint etc. (UV protection)  

      • Exposed nailing 

      • Leaning parapets, stacks, etc.

      • Old, worn out

      • Openings at seams or flashings

      • Patched 

      • Ponding

      • Ridging, fishmouths

      • Splitting

Modified Bitumen Roofing Defects List

      • Asphalt on PVC or other incompatible sealants/coatings

      • Blisters

      • Brittle

      • Cracking

      • Damaged, punctures, tears

      • Debris on roof

      • Discoloration

      • Fasteners loose, backing out, corroded

      • Leaning parapets, stacks, etc.

      • Loss of granules

      • Multiple layers

      • Old, worn out

      • Openings at seams or flashings

      • Patched, ponding

      • Seam runout missing (cold joints on torch-down product)

      • Seam runout excessive (overheated on torch down application)

      • Taut (due to shrinkage)

ROLL ROOFING Defects List (on low slope roofs)

      • Blisters

      • Brittle

      • Cracking

      • Damage, punctures, tears

      • Debris on roof

      • Fasteners loose, backing out, corroded

      • Leaks

      • Leaning parapets, stacks, etc.

      • Loss of granules

      • Membrane movements, slippage

      • Multiple layers

      • Old, worn out

      • Openings at seams or flashings

      • Openings at seams or flashings

      • Patched, ponding (standing water more than 24 hours after rainfall)

      • Wrinkling, ridges, fishmouths

EPDM  Roof Defects List

      • Asphalt based paint or sealant on EPDM or PVC (incompatible)

      • Damage, punctures, tears

      • Debris on roof, oil on roof

      • Discoloration

      • Fasteners loose, backing out, corroded

      • Leaks

      • Leaning parapets, stacks, etc.

      • Mastic on EPDM      

      • Multiple layers Single Ply plastic

      • No UV protection (paint, granules, etc.)

      • Old, worn out

      • Openings at seams or flashings

      • Patched, ponding

      • Surface cracks, splitting

      • Taut (due to shrinkage), tenting

      • Wrinkles, ridges, fishmouths

METAL Roof Defects, Low Slope

      • Asphalt on metal

      • Damage, punctures, tears, bent metal

      • Old, worn out

      • Debris on roof

      • Failed caulking

      • Fasteners loose, backing out, corroded, missing

      • Polystyrene touching PVC

      • Leaks 

      • Surface cracks, orange peeling

      • Open, loose seams

      • Patched, ponding

      • Rust


Low Slope Roof Flashing Defects

      • Caulking, sealant dried out or  cracked

      • Clamps or termination bars loose

      • Counter flashings not let into masonry

      • Damaged, loose, bent

      • Drain or scuppers missing, clogged,  ineffective

      • Fasteners loose, rust, missing

      • Incompatible materials

      • Leaks

      • Membrane stretched

      • Missing, too short

      • Old, worn out

      • Open at seams or ends

      • Patched

      • Ponding on wall flashings (horizontal parts)

      • Pitch pockets not filled

      • Rust

      • Sagging or slipping (base flashings)

      • Skylight curb missing or too short

      • Skylight not well secured

Readers should see ROOFING INSPECTION & REPAIR for our complete list of articles on this topic. Also see HOME & BUILDING INSPECTORS & INSPECTION METHODS. Use the Search Box at the top or bottom of these pages to find in-depth information about building, energy savings, and indoor environment inspection, diagnosis and repair at this website. Watch out: these inspection lists do not list all possible defects for the systems discussed, and not all home or building inspectors will examine all of the items listed here. CONTACT us to suggest corrections or additions to articles at this website.

Also see ROOF FLASHING DEFECTS LIST


Frequently Asked Questions (FAQs)

...

Ask a Question or Search InspectApedia

Use the search box below to ask a question or to search the InspectApedia.com website.

Ask a Question or Enter Search Terms in the InspectApedia search box just below.

Technical Reviewers & References

Related Topics, found near the top of this page suggest articles closely related to this one.

  • Mark Cramer Inspection Services Mark Cramer, Tampa Florida, Mr. Cramer is a past president of ASHI, the American Society of Home Inspectors and is a Florida home inspector and home inspection educator. Mr. Cramer serves on the ASHI Home Inspection Standards. Contact Mark Cramer at: 727-595-4211 mark@BestTampaInspector.com
  • John Cranor is an ASHI member and a home inspector (The House Whisperer) is located in Glen Allen, VA 23060. He is also a contributor to InspectApedia.com in several technical areas such as plumbing and appliances (dryer vents). Contact Mr. Cranor at 804-747-7747 or by Email: johncranor@verizon.net
  • Carson, Dunlop &
Associates Ltd., TorontoCarson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. (416) 964-9415 1-800-268-7070 info@carsondunlop.com. The firm provides professional home inspection services & home inspection education & publications. Alan Carson is a past president of ASHI, the American Society of Home Inspectors. Thanks to Alan Carson and Bob Dunlop, for permission for InspectAPedia to use text excerpts from The Home Reference Book & illustrations from The Illustrated Home. Carson Dunlop Associates' provides:
    • Commercial Building Inspection Courses - protocol ASTM Standard E 2018-08 for Property Condition Assessments
    • Home Inspection Education Courses including home study & live classes at eleven colleges & universities.
    • Home Inspection Education Home Study Courses - ASHI@Home Training 10-course program.
      Special Offer: Carson Dunlop Associates offers InspectAPedia readers in the U.S.A. a 5% discount on these courses: Enter INSPECTAHITP in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.
    • The Home Reference Book, a reference & inspection report product for building owners & inspectors.
      Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.
    • The Home Reference eBook, an electronic version for PCs, the iPad, iPhone, & Android smart phones.
      Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter inspectaehrb in the order payment page "Promo/Redemption" space.
    • The Illustrated Home illustrates construction details and building components, a reference for owners & inspectors.
      Special Offer: For a 5% discount on any number of copies of the Illustrated Home purchased as a single order Enter INSPECTAILL in the order payment page "Promo/Redemption" space.
    • The Horizon Software System manages business operations,scheduling, & inspection report writing using Carson Dunlop's knowledge base & color images. The Horizon system runs on always-available cloud-based software for office computers, laptops, tablets, iPad, Android, & other smartphones.
  • Mark Cramer Inspection Services Mark Cramer, Tampa Florida, Mr. Cramer is a past president of ASHI, the American Society of Home Inspectors and is a Florida home inspector and home inspection educator. Contact Mark Cramer at: 727-595-4211 mark@BestTampaInspector.com 11/06
  • Roger Hankey is principal of Hankey and Brown home inspectors, Eden Prairie, MN. Mr. Hankey is a past chairman of the ASHI Standards Committee. Mr. Hankey has served in other ASHI professional and leadership roles. Contact Roger Hankey at: 952 829-0044 - rhankey@hankeyandbrown.com. Mr. Hankey is a frequent contributor to InspectAPedia.com.
  • Arlene Puentes, an ASHI member and a licensed home inspector in Kingston, NY, and has served on ASHI national committees as well as HVASHI Chapter President. Ms. Puentes can be contacted at ap@octoberhome.com
  • Wikipedia provided background information about some topics discussed at this website provided this citation is also found in the same article along with a " retrieved on" date. NOTE: because Wikipedia entries are fluid and can be amended in real time, we cite the retrieval date of Wikipedia citations and we do not assert that the information found there is necessarily authoritative.

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson DunlopThe Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.

    Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.
  • ASHI Certification Links
  • Home Inspection Reports - a Critique narrative vs. checklist type home inspection reports
  • ASHI Standards of Practice - Jan 2000 and ASHI Standards History - links to older and alternative versions of Home Inspection Standards
  • ASHI Code of Ethics 1993, and ASHI Ethics History - links to older versions; Note: newer may be found at ASHI
  • ASHI in 1996 ASHI History - association description from 1996
  • American Society of Home Inspectors (ASHI) Official Website
  • Basement Moisture Control, U.S. Department of Energy
  • Building Pathology, Deterioration, Diagnostics, and Intervention, Samuel Y. Harris, P.E., AIA, Esq., ISBN 0-471-33172-4, John Wiley & Sons, 2001 [General building science-DF] ISBN-10: 0471331724 ISBN-13: 978-0471331728
  • Building Pathology: Principles and Practice, David Watt, Wiley-Blackwell; 2 edition (March 7, 2008) ISBN-10: 1405161035 ISBN-13: 978-1405161039
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.