INSULATION INSPECTION & IMPROVEMENT

ACOUSTICAL SEALANT CHOICES
AIR LEAK MINIMIZATION
ASBESTOS IDENTIFICATION IN BUILDINGS
ATTIC VENTILATION

BASEMENT CEILING VAPOR BARRIER
BASEMENT HEAT LOSS
BUCKLED FOUNDATIONS due to INSULATION?

CATHEDRAL CEILING INSULATION
CATHEDRAL CEILING VENTILATION
CEILINGS, DROP or SUSPENDED PANEL
CRAWL SPACES

DEHUMIDIFICATION PROBLEMS
DEW POINT TABLE - CONDENSATION POINT
DUCT INSULATION, ASBESTOS PAPER

FIBERGLASS PARTICLE CONTAMINATION
Fiberboard Insulation Sheathing Mold
FIBERGLASS INSULATION MOLD
Fireproofing containing Asbestos
FRAMING DETAILS for BETTER INSULATION
FRAMING DETAILS for DOUBLE WALL HOUSES
FRAMING METAL STUD PERFORMANCE
FREEZE-PROOF A BUILDING

HEAT LOSS in BUILDINGS
HEAT LOSS PREVENTION PRIORITIES
HEAT LOSS R U & K VALUE CALCULATION
HOUSEWRAP AIR & VAPOR BARRIERS
HOUSE DOCTOR, how-to be
HUMIDITY LEVEL TARGET

ICE DAM PREVENTION
INSULATION AIR & HEAT LEAKS
INDOOR AIR QUALITY & HOUSE TIGHTNESS
INSULATION CHOICES
INSULATION FACT SHEET- DOE
INSULATION INSPECTION & IMPROVEMENT
INSULATION MOLD
INSULATION R-Values & Properties

LEED GREEN BUILDING CERTIFICATION
LOG HOME ENERGY EFFICIENCY

MOLD in FOAM INSULATION, RESISTANCE
MOISTURE CONTROL in BUILDINGS

NOISE / SOUND DIAGNOSIS & CURE

PASCAL CALCULATIONS

RADIANT BARRIERS
REFLECTIVE INSULATION
RIGID FOAM USE INDOORS

SHEATHING, FOIL FACED - VENTS
SLAB INSULATION, PASSIVE SOLAR
STAINS on & in BUILDINGS, CAUSES & CURES
STRAW BALE CONSTRUCTION
STUCCO WALL METHODS & INSTALLATION
STUCCO OVER FOAM INSULATION
SWEATING (CONDENSATION) on PIPES, TANKS

Thermal Expansion Cracking of Brick
THERMAL IMAGING, THERMOGRAPHY
THERMAL MASS in BUILDINGS
THERMAL TRACKING Indicates Heat Loss
TRUSS UPLIFT, ROOF

VAPOR BARRIERS & CONDENSATION in BUILDINGS
VENTILATION in BUILDINGS

WALL CONSTRUCTION BARRIER vs CAVITY
WIND WASHING INSULATION At EAVES
WINTERIZE A BUILDING

GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.

More Information

Attic insulation (C) Daniel Friedman Building Insulation Defects List & Home Inspection Education
     

  • DEFECTS LIST - INSULATION - Building insulation & ventilation system defects, definitions, and home inspection education topics
    • Lists of important building insulation defects for residential buildings
    • What does a home inspector need to know about building insulation? Home inspection training and education curriculum recommendations for insulation systems
  • BUILDING DEFECTS LISTS - separate article
  • Questions & Answers about home & building inspection courses, standards, & defect checklists for building insulation
  • References

Click to Show or Hide Related Topics

  • AIR LEAK SEALING PROCEDURE
  • ASBESTOS IDENTIFICATION IN BUILDINGS
  • BASEMENT HEAT LOSS
  • BRICK VENEER WALL AIR LEAKS
  • BUCKLED FOUNDATIONS due to INSULATION?
  • CATHEDRAL CEILING INSULATION
  • CRAWL SPACE INSULATION RETROFIT
  • DEFECTS LIST - INSULATION
  • DEFINITION of R-VALUE
  • DEW POINT CALCULATION for WALLS
  • FIBERGLASS HAZARDS
  • FIBERGLASS INSULATION
  • FIBERGLASS INSULATION MOLD
  • FIBERGLASS PARTICLE CONTAMINATION TEST
  • FRAMING DETAILS for BETTER INSULATION
  • FREEZE-PROOF A BUILDING
  • FORMALDEHYDE HAZARDS
  • HEAT LOSS in BUILDINGS - home
  • HEAT LOSS DETECTION TOOLS
  • HEAT LOSS INDICATORS
  • HEAT LOSS PREVENTION PRIORITIES
  • HOUSEWRAP & VAPOR BARRIERS
  • ICE DAM PREVENTION
  • INSULATION CHOICES - home
  • INSULATION IDENTIFICATION GUIDE - home
  • INSULATION INSPECTION & IMPROVEMENT - home
  • INSULATION LOCATION - WHERE TO PUT IT - home
  • INSULATION MOLD
  • INSULATION R-Values & Properties
  • LOG HOME WALL INSULATION VALUES
  • NOISE / SOUND DIAGNOSIS & CURE
  • RADIANT BARRIERS & REFLECTIVE INSULATION
  • SLAB INSULATION, PASSIVE SOLAR
  • THERMAL IMAGING, THERMOGRAPHY
  • THERMAL TRACKING Indicates Heat Loss
  • VAPOR BARRIERS & CONDENSATION in BUILDINGS
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

This article lists significant building insulation & ventilation system defects, definitions, and home inspection education topics. This article series, beginning at BUILDING DEFECTS LISTS, provides lists of common building defects and basic defect knowledge that also outline recommended curriculum content for home inspector education. The building defects and inspection points listed in these articles also guide homeowners and home buyers to building areas that merit careful attention and often point areas of safety concern or important maintenance and repair tasks.

Green links show where you are. © Copyright 2013 InspectAPedia.com, All Rights Reserved. Author Daniel Friedman.

Home Inspection Education Curriculum - Insulation & Ventilatation Systems

8.0   INSULATION AND VENTILATION Inspection Requirements & Defects List


8.1   Building Insulation Inspection Requirements & Common Defects

8.1.1 Knowledge Base for Building Insulation System Inspections


1.    Describe the function of insulation and roof and underfloor space ventilation systems in homes including controlling heat and moisture flow in the building envelope.

2.    Describe the function of air barriers and vapor barriers (vapor retarder, vapor diffusion retarder)

3.    Describe these common forms of insulation - loose fill, batts or blankets rigid boards, foamed-in-place

4.    Describe the properties of these common insulation materials – fiberglass, cellulose, mineral wool, vermiculite and perlite, expanded polystyrene, extruded polystyrene, polyisocyanurate, polyurethane (how about urea-formaldehyde?)

5.    List two common air/vapor barrier materials.

6.    Describe the features of  adequate installation and repair technique with respect to insulation, air vapor barrier and ventilation in floors, walls and roof systems.  Distinguish between attics and cathedral ceilings or flat roofs.

7.    Define the following terms:

      degree-days, ventilation-unconditioned spaces, ventilation-fresh air for occupants, heat vs. temperature, british thermal unit (BTU), sensible heat, latent heat of vaporization, latent heat of fusion, conduction, radiation, convection, evaporation, thermal conductivity, thermal conductance, thermal conductor, thermal insulator, thermal resistance, air leakage, wind washing, condensation, absolute humidity, relative humidity, stack effect, neutral pressure plane, dew point temperature, vapor diffusion, drying potential, sheathing, housewrap, building paper, direct vent appliance, indoor air quality (IAQ), depressurization, heat transfer, thermal bridge, convective loop, radiant barrier, R value, perm, insulating sheathing, cold wall effect, cold floor effect.

8,    Identify the codes or standards which apply to insulation and ventilation systems in your area.


8.1.2 Inspection Skills for Building Insulation Systems

1.    Describe the inspection procedure for insulation in attics, other roof spaces, walls, floors, basements and crawl spaces.

2. Identify the following common defects listed on the next page.

3.    Describe the implications of each defect

4.    Identify safety issues for the inspector and occupant of the house (injury due to falling through the attic, electric shock).

5.    Communicate findings to client verbally and in writing, recommending corrective action when needed.

Building Insulation, Typical Defects List

FOUNDATION  INSULATION Defects List

      • Exterior insulation not protected at top   

      • Exterior insulation not suitable for use below grade


FLOORS OVER UNHEATED AREAS, Insulation Defects List

      • Evidence insulation has been added

      • Too little insulation (usually difficult to tell)

WALLS, Insulation Defects List

      • Evidence insulation has been added

      • Evidence of no insulation (visual inspection from basement or crawl

gives view into some wall bottom cavities, outside moisture or paint clues,

fishing for insulation at available wall openings such as at receptacles,

thermography or similar surveys (not usually part of a home inspection))

PULL-DOWN STAIRS, Insulation Defects List

      • Dangerous to lower or raise

      • Not insulated

      • Not weatherstripped

      • Unsafe to climb

 

ATTIC ACCESS HATCH, Insulation Defects List

      • Inaccessible        

      • Missing  

      • Not weatherstripped

      • Not insulated      


ATTIC STAIRCASES, Insulation Defects List

      • Excessive rise on steps

      • Handrails or guardrails missing or unsafe

      • Headroom inadequate

      • Inadequate insulation

      • Inadequate run and tread width

      • Inadequate weatherstripping

      • Lighting missing or ineffective

      • Treads sloped or not uniform

      • Treads loose or broken

      • Properly secured/installed pull-down staircases.  JDG


INSULATION & Vapor Barriers, General, Insulation Defects List       

      • Air/vapor barrier wrong location   

      • Air leakage excessive

      • Air/vapor barrier incomplete     

      • Air/vapor barrier missing  

      • Combustible insulation too close to masonry chimney

      • Compressed                  

      • Covering recessed lights

      • Foam insulation exposed in occupied space - fire hazards

      • Gaps or voids                             

      • Inadequate in knee wall areas

      • Inadequate at skylights and light wells

      • Insulation too close to metal chimney

      • Missing at dropped ceilings

      • Mold or mold-suspect (has been wet)

      • Rodent or insect or other pest contamination (disturbed, feces, odors)

      • Too little amount of insulation

      • Wet insulation


ROOF VENTING, Insulation Defects List       

    • Inadequate

    • Missing

    • Obstructed

    • Snow or wet spots below roof vents

TURBINE VENTS, Insulation Defects List       

    • Noisy

    • Seized

 

POWER VENTS, Insulation Defects List       

    • Inoperative in summer (winter or other conditions may preclude testing)

    • Operating in winter

    • Poor wiring

PARTY WALLS (Fire Partitions), Insulation Defects List    

     • Ice dams

     • Not continuous – incomplete, penetrated

EXHAUST FANS, Insulation Defects List       

      • Cover missing       

      • Damaged   

      • Disconnected

      • Ducts leaky

      • Inadequate air movement

      • Inoperative

      • Missing

      • Noisy

      • Not insulated in unconditioned space

      • Poor termination location

      • Termination point not found

      • Wiring unsafe


INSULATION IN BASEMENTS & CRAWL SPACES, Insulation Defects List       

      • Air/vapor barrier missing, incomplete or in wrong location

      • Exposed combustible insulation

      • Incomplete

      • Missing at rim joists

      • No moisture barrier on basement walls

      • No moisture barrier on earth floor

      • Sagging, loose or voids

      • Too little

    

Readers should see INSULATION INSPECTION & IMPROVEMENT for our complete list of articles on this topic. Also see HOME & BUILDING INSPECTORS & INSPECTION METHODS. Use the Search Box at the top or bottom of these pages to find in-depth information about building, energy savings, and indoor environment inspection, diagnosis and repair at this website. Watch out: these inspection lists do not list all possible defects for the systems discussed, and not all home or building inspectors will examine all of the items listed here. CONTACT us to suggest corrections or additions to articles at this website.

Also see INTERIORS DEFECTS LIST, and VAPOR BARRIERS & CONDENSATION in buildings and VENTILATION in BUILDINGS as well as Readers should see INSULATION INSPECTION & IMPROVEMENT for our complete list of articles on this topic. Also see HOME & BUILDING INSPECTORS & INSPECTION METHODS. Use the Search Box at the top or bottom of these pages to find in-depth information about building, energy savings, and indoor environment inspection, diagnosis and repair at this website. Watch out: these inspection lists do not list all possible defects for the systems discussed, and not all home or building inspectors will examine all of the items listed here. CONTACT us to suggest corrections or additions to articles at this website.

Also see INTERIORS DEFECTS LIST, and VAPOR BARRIERS & CONDENSATION in buildings and VENTILATION in BUILDINGS as well as ENERGY SAVINGS in buildings

These curriculae and building defect lists are based on smilar curriculum documents first prepared by Joe Scaduto, an ASHI member who prepared course material for Northeastern University's Building Inspection Certificate program in 1988, subsequently by DF, InspectApedia's editor, for New York University ca 1988 and later, with others, recommended to ASHI, the American Society of Home Inspectors. ASHI did not adopt this material though currently that association as well as others offer extensive HOME INSPECTOR EDUCATION material. The curriculum and lists of defects are informed by additional analysis of the process of home inspection that was developed beginning Calgary, AB for Canadian and U.S. home inspector education and certification examinations in 1997. Other early contributors to home inspection education in the U.S. and Canada include Dr. Jess Aronstein, Alan Carson, Mike Casey, Mark Cramer, John Cox, Dwight Barnett, Douglas Hansen, Rick Heyl, Larry Hoytt, Bill Merrill, Kevin O'Malley, Dennis Robitalille, Keith Peddie, Pat Porzio, Roger Robinson.

...


Frequently Asked Questions (FAQs)

...

Ask a Question or Search InspectApedia

Use the search box below to ask a question or to search the InspectApedia.com website.

Ask a Question or Enter Search Terms in the InspectApedia search box just below.

Technical Reviewers & References

Related Topics, found near the top of this page suggest articles closely related to this one.

  • Mark Cramer Inspection Services Mark Cramer, Tampa Florida, Mr. Cramer is a past president of ASHI, the American Society of Home Inspectors and is a Florida home inspector and home inspection educator. Mr. Cramer serves on the ASHI Home Inspection Standards. Contact Mark Cramer at: 727-595-4211 mark@BestTampaInspector.com
  • John Cranor is an ASHI member and a home inspector (The House Whisperer) is located in Glen Allen, VA 23060. He is also a contributor to InspectApedia.com in several technical areas such as plumbing and appliances (dryer vents). Contact Mr. Cranor at 804-747-7747 or by Email: johncranor@verizon.net
  • Carson, Dunlop &
Associates Ltd., TorontoCarson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. (416) 964-9415 1-800-268-7070 info@carsondunlop.com. The firm provides professional home inspection services & home inspection education & publications. Alan Carson is a past president of ASHI, the American Society of Home Inspectors. Thanks to Alan Carson and Bob Dunlop, for permission for InspectAPedia to use text excerpts from The Home Reference Book & illustrations from The Illustrated Home. Carson Dunlop Associates' provides:
    • Commercial Building Inspection Courses - protocol ASTM Standard E 2018-08 for Property Condition Assessments
    • Home Inspection Education Courses including home study & live classes at eleven colleges & universities.
    • Home Inspection Education Home Study Courses - ASHI@Home Training 10-course program.
      Special Offer: Carson Dunlop Associates offers InspectAPedia readers in the U.S.A. a 5% discount on these courses: Enter INSPECTAHITP in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.
    • The Home Reference Book, a reference & inspection report product for building owners & inspectors.
      Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.
    • The Home Reference eBook, an electronic version for PCs, the iPad, iPhone, & Android smart phones.
      Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter inspectaehrb in the order payment page "Promo/Redemption" space.
    • The Illustrated Home illustrates construction details and building components, a reference for owners & inspectors.
      Special Offer: For a 5% discount on any number of copies of the Illustrated Home purchased as a single order Enter INSPECTAILL in the order payment page "Promo/Redemption" space.
    • The Horizon Software System manages business operations,scheduling, & inspection report writing using Carson Dunlop's knowledge base & color images. The Horizon system runs on always-available cloud-based software for office computers, laptops, tablets, iPad, Android, & other smartphones.
  • Mark Cramer Inspection Services Mark Cramer, Tampa Florida, Mr. Cramer is a past president of ASHI, the American Society of Home Inspectors and is a Florida home inspector and home inspection educator. Contact Mark Cramer at: 727-595-4211 mark@BestTampaInspector.com 11/06
  • Roger Hankey is principal of Hankey and Brown home inspectors, Eden Prairie, MN. Mr. Hankey is a past chairman of the ASHI Standards Committee. Mr. Hankey has served in other ASHI professional and leadership roles. Contact Roger Hankey at: 952 829-0044 - rhankey@hankeyandbrown.com. Mr. Hankey is a frequent contributor to InspectAPedia.com.
  • Arlene Puentes, an ASHI member and a licensed home inspector in Kingston, NY, and has served on ASHI national committees as well as HVASHI Chapter President. Ms. Puentes can be contacted at ap@octoberhome.com
  • Wikipedia provided background information about some topics discussed at this website provided this citation is also found in the same article along with a " retrieved on" date. NOTE: because Wikipedia entries are fluid and can be amended in real time, we cite the retrieval date of Wikipedia citations and we do not assert that the information found there is necessarily authoritative.

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson DunlopThe Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.

    Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.
  • ASHI Certification Links
  • Home Inspection Reports - a Critique narrative vs. checklist type home inspection reports
  • ASHI Standards of Practice - Jan 2000 and ASHI Standards History - links to older and alternative versions of Home Inspection Standards
  • ASHI Code of Ethics 1993, and ASHI Ethics History - links to older versions; Note: newer may be found at ASHI
  • ASHI in 1996 ASHI History - association description from 1996
  • American Society of Home Inspectors (ASHI) Official Website
  • Basement Moisture Control, U.S. Department of Energy
  • Building Pathology, Deterioration, Diagnostics, and Intervention, Samuel Y. Harris, P.E., AIA, Esq., ISBN 0-471-33172-4, John Wiley & Sons, 2001 [General building science-DF] ISBN-10: 0471331724 ISBN-13: 978-0471331728
  • Building Pathology: Principles and Practice, David Watt, Wiley-Blackwell; 2 edition (March 7, 2008) ISBN-10: 1405161035 ISBN-13: 978-1405161039
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
    Building inspection education & report writing systems from Carson, Dunlop & Associates Ltd
  • Crawl Space Moisture Control, U.S. Department of Energy
  • Historic Preservation Technology: A Primer, Robert A. Young, Wiley (March 21, 2008) ISBN-10: 0471788368 ISBN-13: 978-0471788362
  • ...

HOME ABOUT CONTACT COPYING DESCRIPTION POLICIES PRINTING PRIVACY © 2013 Copyright InspectAPedia.com