Mobile ViewELECTRICAL INSPECTION, DIAGNOSIS, REPAIR AFCIs ARC FAULT CIRCUIT INTERRUPTERS ALUMINUM SECs & WIRING ALUMINUM WIRING HAZARDS AMPS & VOLTS DETERMINATION AMPACITY - the LIMITING FACTOR APPLIANCE EFFICIENCY RATINGS BACKUP ELECTRICAL GENERATORS Cadet & Encore Heater Recall CIRCUIT BREAKER FAILURE CIRCUIT BREAKER SIZE for A/C or HEAT PUMP CIRCUIT BREAKER SIZE for A/C or HEAT PUMP Classified CIRCUIT BREAKER WARNING CUTLER HAMMER PANEL FIRE CONDUIT, ELECTRICAL CORROSION in ELECTRICAL PANELS CORROSION & MOISTURE SOURCES in PANELS DEFINITIONS of ELECTRICAL TERMS DIRECTORY OF ELECTRICIANS DIRECTORY OF ELECTRICIANS - Aluminum Wiring DIRECTORY OF ELECTRICIANS - FPE Zinsco ELECTRIC HEAT ELECTRIC METERS & METER BASES ELECTRIC MOTOR DIAGNOSTIC GUIDE ELECTRIC MOTOR OVERLOAD RESET SWITCH ELECTRIC PANEL AMPACITY ELECTRIC PANEL INSPECTION ELECTRIC PANEL MOISTURE Electric Power Frequency Table ELECTRICAL BASICS EMF RF FIELD & FREQUENCY DEFINITIONS ENERGY SAVINGS in buildings ELECTRICAL GENERATORS ELECTRICAL GROUND SYSTEM INSPECTION FEDERAL PACIFIC FPE HAZARDS FEDERAL PACIFIC FPE HAZARD SUMMARY FPE FAILURE REPORTS FPE FIRE & FAILURE PHOTOS FPE FAILURE FIELD REPORTS FPE HAZARD ARTICLES, STUDIES Summary of the FPE Stab-Lok Hazard FPE Fraud - Press Release FPE Fraud Stab-Lok SEC report FPE Exxon Scandal Article How to Repair FPE Stab-Lok FPE- Fires Waiting to Happen, Debate Waiting to End FPE Technical Report - Independent Research 2007 FPE Technical Report - Independent Research 2011 New Jersey FPE Class Action 2005 FPE St Louis Seminar 2004 Federal Pioneer Recall 1997 EXXON Buys a Scandal 1980 FPE HISTORIC DATES 1950-Present FPE Pre-1970 STAB-LOKS OK? FPE HISTORY FPE & FP IDENTIFICATION, HOW TO FPE STAB-LOK PANEL COVERS FEDERAL NOARK PANELS FEDERAL ELECTRIC PANELS FEDERAL PIONEER PANELS FPE PANEL DOOR LABELS FPE TOGGLE SWITCH FPE BREAKER ID PHOTOS FPE BREAKER LABELS HOW TO ID FPE IF NO LABELS FPE PANEL BUS DESIGNS FPE PANEL AGE MATTERS? OTHER FPE DEFECTS FPE INCIDENTS, HOW TO REPORT FPE INVESTIGATION CPSC Revised FPE INVESTIGATION CPSC 1982 FPE INVESTIGATION CPSC 1983 FPE IAEI LETTER INACCURATE FPE INVESTIGATION CPSC Revised FPE INVESTIGATION CPSC 1982 FPE INVESTIGATION CPSC 1983 FPE HAZARD IAEI LETTER INACCURATE FPE PANEL ADVICE for HOME BUYERS FPE PANEL INSPECTION REPORTS FP FEDERAL PIONEER in CANADA What Are Federal Pioneer Panel Concerns? Federal Pioneer Warranty Alert Federal Pioneer Electrical Circuit Breaker Recall Field Reports of Federal Pioneer Problems Other Federal Pioneer Concerns Are Recent Federal Pioneer Stab-Loks Safe? FEDERAL PIONEER PANELS FPE REPAIR ELECTRICIANS FPE REPLACEMENT BREAKERS FPE REPLACEMENT PANELS FPE REPLACEMENT PANEL COSTS CAN'T AFFORD A NEW ELECTRIC PANEL? FPE Stab-Lok Panel Test Report FPE PANEL Test Performed FPE PANEL Test Results Photos of FPE Stab-Lok Panel FPE SUB PANELS, RISK ASSESSMENT FPE STAB-LOK: FIRES WAITING TO HAPPEN How Many Stab-Loks Stab-Lok Failure Rate Proper Repair Proving the Hazard Multiwire Circuits Single Pole Breakers Latent Safety Hazard Failure Reports Technical Reports FPE Stab-Lok TECHNICAL REPORT FPE Stab-Lok Circuit Breaker Test Results CPSC Tests FPE Test Results Southwest Research Incorporated Underwriters Laboratories Inc. Recent Testing of Field Samples FPE Stab-Lok Combination Breaker/GFI Non-FPE Stab-Lok Breakers FPE Main Breakers FPE Stab-Lok Panels FPE Stab-Lok Panels with "Rule of Six" Configuration Hazardous Failure - an Example History of the FPE Problem Should FPE Panels be Replaced? FPE Stab-Lok TECHNICAL REPORT-2004 FPE Stab-Lok Panel Test Report FPE PANEL Test Performed FPE PANEL Test Results Photos of FPE Stab-Lok Panel FPE Stab-Lok Hazard Summary Page for Public Use GENERATORS, ELECTRICAL GFCI PROTECTION,Testing GFCIs AFCIs HEATING COST FUEL & BTU Cost Table HEAT, ELECTRIC HEAT TAPE USAGE GUIDE Hertz - Definitions of KHz MHz GHz THz KNOB & TUBE WIRING LIGHTING, EXTERIOR GUIDE LIGHTING, INTERIOR GUIDE LIGHTNING PROTECTION SYSTEMS LOW VOLTAGE BUILDING WIRING MAIN DISCONNECT MAIN DISCONNECT AMPACITY MOISTURE SOURCES in PANELS MULTI-WIRE CIRCUITS MURRAY SIEMENS Recall PHOTOVOLTAIC POWER SYSTEMS PUSHMATIC - BULLDOG PANELS REMOTE ELECTRIC POWER, PHOTOVOLTAIC RUST in ELECTRICAL PANELS SAFETY for ELECTRICAL INSPECTORS SE CABLE SIZES vs AMPS SIEMENS MURRAY Recall SQUARE-D RECALLS UNDERGROUND SERVICE LATERALS VOLTAGE MEASUREMENT EQUIPMENT WIND ENERGY SYSTEMS WIND TURBINES & LIGHTNING ZINSCO / SYLVANIA HAZARDS More Information |
This document discusses the typical costs to replace an electrical panel. This information on electrical panel replacement costs suipports our articles describing hazards leading to the need to replace Federal Pacific Stab-Lok Electric Panels or Zinsco / Zinsco-Sylvania Electric Panels in buildings. Replacement FPE Stab-Lok circuit breakers are unlikely to reduce the failure risk of this equipment. We recommend that residential FPE Stab-Lok electrical panels be replaced entirely or the entire panel bus assembly be replaced, regardless of FPE model number or FPE year of manufacture. We do not sell circuit breakers nor any other products. InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers nor with topics or services discussed at this website.© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website. Electrical Panel REPLACEMENT COST Typical cost of the traditional FPE Electrical Panel ReplacementQuotes From Electrical Contractors on Electric Panel ReplacementQuotes from electrical contractors on panel replacement by installing a complete, new, electrical panel, can be expected to vary by area of the country, hardware needed, replacement panel size in ampacity and number of circuits, accessibility to perform the work, and other factors that affect labor or materials. That said, we've heard panel replacement costs ranging from $1,200. to $4,000 (April 2007, Northwestern United States). If you are surprised by the quotation you receive from your electrician, ask for the supporting details of the bid or ask for a bid from a competitor too. Shop expertise and workmanship not just price. Northeastern U.S.: Typically the installation of a new 100-Amp electrical pane in the Northeastern U.S. is around $1,200 to $1,500. (June 2006, Northeastern U.S.). This figure does not include the additional cost for a service panel (150A or 200A), extra labor, or materials for demolition and repair of a wall needed to address an electric panel which is already installed. Southwestern U.S.: (Such as Dallas Fort Worth) Typically the installation of a new 100-Amp electrical pane in the Southwestern U.S. is around $1,200 to $2,100. (February 2008 Dallas Electrical Costs). A 150A or 200A electrical panel may cost up to $2400. from some installers. Additional costs for replacement electrical panel installations: may be expected where there is difficulty of access, where demolition and wall repair are needed, where the electrical service is being upgraded to a larger ampacity than that of the panel being replaced, or where there are other special requirements. Typical factors affecting the cost of electrical repair and retrofit work are discussed in more detail just below. The "Short Wire" problem and the Eaton Renovation Load Center: Electrical panel, FPE, Zinsco, or any other brand can be extra difficult when replacing the entire panel if only short lengths of wire are available in the old electrical box. Especially if the new electric panel is physically larger than the one being replaced, the original wires may not reach the circuit breakers in the new panel. A product which might help when the entire loadcenter (what normal people call the "electric panel") is going to be replaced. is E-CH's "Renovation Loadcenters". The unique feature is that UL listed terminal blocks are provided in the enclosure as a means to terminate existing wires too short to reach the new panel's branch circuit breakers or neutral bus. A new wire can then be wired from the terminal block to the breaker or neutral. This is a safer method than the twist-on connectors commonly used, or a separate terminal box, which takes up extra space. I do not discuss this approach further here but more information is available from Eaton Corp., Cutler Hammer Products or through your electrician and electrical supplier. "RETROFIT COST - Cost of Replacing an FPE Panel using the E-CH Adjustable Retrofit Kit" discusses the costs of FPE panel replacement using Cutler Hammer's retrofit electrical panel kit. This money-saving option is sometimes suitable, depending on the physical dimensions of the original electrical panel and the ampacity of the new service to be installed. Factors Affecting the Cost of an Electrical Panel Replacement
Questions & Answers regarding this articleQuestions & answers about how much it costs to replace an electrical panel and how costs may vary by hardware options, wiring complexity and number of circuits, ease of access, as well as geographic area. Ask a Question or Search InspectAPediaHTML Comment Box is loading comments...
Recommend / Share this Article
... Technical Reviewers & References
Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website. FPE Stab-Lok HAZARDS & REPAIRS WEBSITE - See detailed links at page left
Information Source Citations & Feedback RequestInformation Source Notice: portions of the text of this document are from email exchanged between the web author and the Eaton Corp., Cutler Hammer Products Lead Design Engineer and Eaton Product Manager involved with the products discussed in this document. The illustration at page top is from the Eaton Electrical PDF which describes their product line. The author has no financial nor any other connection with Eaton Corp., Cutler Hammer Products, nor any other company whose products are discussed at this website. Corrections of errors or omissions, product user feedback, or other critique are invited. Our editorial policies are at Accuracy & Bias Pledge We solicit photos and description of field experience from installing electricians and from consumers. Contact Us to report field experience with this equipment. Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair
|