InspectAPedia.com InspectAPedia®
Google
InspectAPedia
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • DAMAGE ASSESSMENT
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US



InspectAPedia ® Home

EXTERIORS of buildings

ADHESIVES, EXTERIOR CONSTRUCTION
AGE of a BUILDING - how to determine
ALGAE, FUNGUS, LICHENS, MOSS
ANIMAL ENTRY POINTS in buildings
ANIMAL ODORS IN buildings
ARCHITECTURE & BUILDING COMPONENT ID
ASBESTOS IDENTIFICATION IN buildings
ATTIC CONDENSATION CAUSE & CURE

BARK SIDE UP on DECKS & STEPS
BASEMENT WATERPROOFING
BEST CONSTRUCTION PRACTICES GUIDE
BRICK VENEER WALL Loose, Bulged
BRICK WALL DRAINAGE WEEP HOLES
BOOKSTORE - EXTERIORS

CARPENTER ANTS
CARPENTER BEES
CATCH BASINS
CAULK GUN TYPES, CHOICES
CAULKS & SEALANTS, EXTERIOR
CHIMNEY INSPECTION DIAGNOSIS REPAIR
COLUMNS & POSTS, DEFECTS
CONTAINER HOUSING
CONCRETE FOUNDATIONS
CONNECTORS, FASTENERS, TIES
CRAWL SPACES

DECK & PORCH CONSTRUCTION
DECK COLLAPSE Case Study
DECK FINISHES COATINGS PRESERVATIVES
DECK FLASHING LEAKS, ROT Case Study
DEFINITIONS of ENGINEERED WOOD OSB LVL etc
DRYWELLS, FRENCH DRAINS for FLAT SITES

EARTHQUAKE DAMAGED FOUNDATIONS
EIFS & STUCCO EXTERIORS
EXTERIOR WALL SIDING TRIM & FINISHES

FLASHING MEMBRANES PEEL & STICK
FLASHING for METAL ROOFS
FLASHING ROOF WALL DETAILS
FLASHING ROOF-WALL SNAFU
FLASHING SIDING DETAILS
FLASHING WALL DETAILS
FLASHING WINDOW DETAILS
FLASHING WOOD ROOF DETAILS
FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
FROST HEAVES, FOUNDATION, SLAB
FOOTING & FOUNDATION DRAINS
FOUNDATION WATERPROOFING
FRENCH DRAINS

GALVANIC SCALE & METAL CORROSION
GLUES ADHESIVES, EXTERIOR CONSTRUCTION
GRADING, DRAINAGE & SITE WORK
GUTTERS & DOWNSPOUTS

HEAT TAPES & CABLES on Roofs for Ice Dams
HOUSE PARTS, DEFINITIONS
HOUSEWRAP / SHEATHING WRAP
HOUSEWRAP INSTALLATION DETAILS
HOUSEWRAP PRODUCT CHOICES
HOUSEWRAP at SILLS, SOLES, TOP PLATES
HUMIDITY LEVEL TARGET

ICE DAM PREVENTION
INDOOR AIR QUALITY & HOUSE TIGHTNESS
INSECT INFESTATION / DAMAGE

KIT HOMES, Aladdin, Sears, Wards, Others

LEAD POISONING HAZARDS GUIDE
LEAD TEST KIT for HOME USE
LEED GREEN BUILDING CERTIFICATION
LOG HOME GUIDE
LIGHTNING PROTECTION

MOLD DETECTION & INSPECTION GUIDE

ODORS & SMELLS DIAGNOSIS & CURE

PAINT & STAIN GUIDE, EXTERIOR
PAINT FALURE, DIAGNOSIS, CURE, PREVENTION
PAINT FAILURE DICTIONARY
PAINT SURFACE PREPARATION
PAINTING MISTAKES
PORCHES & Sunrooms
PORCH CONSTRUCTION & SCREENING

RAILINGS, DECK & PORCH
RAILINGS, STAIRWAY
RETAINING WALL DESIGNS, TYPES, DAMAGE
RETAINING WALL GUARD RAILINGS

ROOF ARCHITECTURAL STYLES - PHOTO GUIDE
ROOF CLEANING RECOMMENDATIONS
ROOF DORMER TYPES - PHOTO GUIDE
ROOFING DIAGNOSIS INSPECTION & REPAIR
ROOF VENTILATION SPECIFICATIONS

SEPTIC SYSTEM INSPECT DIAGNOSE REPAIR

SHEATHING, Gypsum board
Sheathing Celotex Homasote & Other
SHEATHING, OSB
SHEATHING, Plywood
SHEATHING, FOIL FACED - VENTS

SIDING TYPES, INSTALLATION, DEFECTS
SINKHOLES, WARNING SIGNS
SOUND CONTROL in buildings
STAIN & BIODETERIORATION AGENT CATALOG
STAINS on & in BUILDINGS, CAUSES & CURES
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIN DIAGNOSIS on ROOFS
STAIN DIAGNOSIS on STONE
STAINS on INDOOR SURFACES: PHOTO GUIDE
STAIRS, RAILINGS, LANDINGS, RAMPS
STONE CLEANING METHODS
STONE VENEER WALLS
STRAW BALE CONSTRUCTION
STUCCO WAll FAILURES DUE TO WEATHER
STUCCO WALL METHODS & INSTALLATION
STUCCO OVER FOAM INSULATION
STUCCO PAINT FAILURES
SURFACE GRADING, SITE DRAINAGE

TERMITES
TEST KITS for DUST, MOLD, PARTICLE TESTS
Thermal Expansion Cracking of Brick
THERMAL EXPANSION of MATERIALS
THERMAL IMAGING, THERMOGRAPHY
THERMAL IMAGING MOLD SCANS
THERMAL MASS in BUILDINGS
TREES & SHRUBS, TRIM OFF BUILDING
TRIM, EXTERIOR CHOICES, INSTALLATION

VAPOR BARRIERS & CONDENSATION in buildings
VENTILATION in BUILDINGS

WALL CONSTRUCTION BARRIER vs CAVITY
WATER BARRIERS, EXTERIOR BUILDING
WATER ENTRY in buildings
WIND ENERGY SYSTEMS
WIND TURBINES & LIGHTNING
WINTERIZE A BUILDING

More Information

Photograph of badly deteriorated hardboard siding Boise Cascade Hardboard Siding Failures Information
     

  • Boise Cascade siding damage explanation, inspection, & failure diagnosis guide
    • Boise Cascade Siding Failures & class action lawsuit contact information.
  • SIDING HARDBOARD - separate article, all brands: Abatibi, ABTCO, Boise Cascade, Georgia Pacific, James Hardi HardiePlank, Louisiana Pacific, Masonite, Shakertown, Weyerhaeuser, Wolverine
    • ABATIBI Siding Claims - separate article Abatibi hardboard siding failure information
    • ABTCO hardboard siding failures
    • BOISE CASCADE Siding Claims
    • JAMES HARDIE HardiePlank Siding
    • MASONITE Siding Claims - Masonite & other brands of hardboard siding failures and information; Colorlok siding paint
  • SIDING, FIBER CEMENT - separate article
  • Questions & Answers about hardboard siding failures, claims, replacement, repair, painting, maintenance, Boise Cascade
  • Questions & Answers about hardboard siding failures, claims, replacement, repair, painting, maintenance
  • References

Click to Show or Hide Related Topics

  • SIDING TYPES, INSTALLATION, DEFECTS - home
  • ALGAE, FUNGUS, LICHENS, MOSS
  • BRICK VENEER WALL Loose, Bulged
  • BRICK WALL DRAINAGE WEEP HOLES
  • CAULKS & SEALANTS, EXTERIOR
  • DECK FINISHES COATINGS PRESERVATIVES
  • EIFS & STUCCO EXTERIORS
  • FLASHING SIDING DETAILS
  • FLASHING WALL DETAILS
  • FLASHING WINDOW DETAILS
  • HOUSEWRAP / SHEATHING WRAP
  • HOUSEWRAP INSTALLATION
  • METAL LATH, PLASTER & STUCCO
  • MOISTURE CONTROL in BUILDINGS - home
  • PAINT & STAIN GUIDE, EXTERIOR
  • PAINT FALURE, DIAGNOSIS
  • SIDING, ALUMINUM
  • SIDING, ASBESTOS FIBER CEMENT
  • SIDING ASPHALT ROOF SHINGLES on WALLS
  • SIDING ASPHALT SHINGLE or SHEET
  • SIDING DAMAGE by SPLASHBACK
  • SIDING EIFS & STUCCO
  • SIDING, FIBER CEMENT
  • SIDING GAPS & CAULKING
  • SIDING HARDBOARD, ABATIBI, BOISE, MASONITE
  • SIDING HARDIEPLANK
  • SIDING, LOG
  • SIDING STEEL
  • SIDING VINYL
  • SIDING VINYL INSTALLATION
  • SIDING, WOOD PRODUCT CHOICES
  • SIDING, WOOD INSTALLATION
  • SIDING WOOD, FAILURES OVER FOAM BOARD
  • SIDING WOOD, FLASHING DETAILS
  • SIDING WOOD SHINGLE INSTALLATION
  • STAIN DIAGNOSIS on BUILDING EXTERIORS
  • STRUCTURAL DAMAGE PROBING
  • STUCCO WALL METHODS & INSTALLATION
  • STUCCO WAll FAILURES DUE TO WEATHER
  • STUCCO WALL METHODS & INSTALLATION
  • STUCCO OVER FOAM INSULATION
  • STUCCO PAINT FAILURES
  • TREES & SHRUBS, TRIM OFF BUILDING
  • TRIM, EXTERIOR CHOICES, INSTALLATION
  • VAPOR BARRIERS & CONDENSATION
  • WALL SIDING TRIM & FINISHES
  • WATER BARRIERS, EXTERIOR BUILDING
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

Boise Cascade™ hardboard siding is similar to products sold by Masonite Corp., Abatibi-Price, and Georgia Pacific Corp, both of which experience failures of delamination, swelling, softening, and general deterioration when exposed to water and weather.

Green links show where you are. © Copyright 2013 InspectAPedia.com, All Rights Reserved. Author Daniel Friedman.

Common Causes of Boise Cascade™ and other Hardboard Building Siding Failures

Our own field observations show that the siding material deteriorates fastest and most severely where:

  • The Boise Cascade™ hardboard siding (and similar products) has not been kept perfectly sealed and coated against water intrusion
  • The Boise Cascade™ hardboard siding has been damaged by cuts, nicks, or by counter-sunk siding nails that penetrated its top skin and were not kept perfectly sealed
  • The Boise Cascade™ hardboard siding has been exposed to high amounts of rain (weather side of buildings), or where it is exposed to roof spillage splash-up against siding, for example where building gutters and leaders are not installed or are not properly maintained
  • The end butt-joints of the Boise Cascade™ siding were not kept sealed where exposed to weather
  • Water penetrates the Boise Cascade™ siding and building wall at poorly-flashed or poorly-installed windows, doors, or other wall penetrations

We have photographs and material samples on-hand and solicit field reports and photographs to add to Abatibi siding identification, maintenance, repair, replacement, and class action information at this website.

If you have additional product failure examples you are welcome to contact the author to provide additional field photos or information that may assist others in identifying and repairing siding failures.


Frequently Asked Questions (FAQs)

...

Ask a Question or Search InspectApedia

Use the search box below to ask a question or to search the InspectApedia.com website.

Ask a Question or Enter Search Terms in the InspectApedia search box just below.

Technical Reviewers & References

Related Topics, found near the top of this page suggest articles closely related to this one.

  • ...

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson DunlopThe Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.

    Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.

  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
    Building inspection education & report writing systems from Carson, Dunlop & Associates Ltd
  • Analysis of Modern Paints, Thomas J.S. Learner, Research in Conservation, 2004 ISBN 0-89236-779-2 [Chemistry of modern paints, overview of analytical methods, pyrolysis-gas chromatography signatures of basic modern paints and their constituents, Fourier transform infrared spectroscopy for paint analysis, direct temperature-resolved mass spectrometry, and analysis in practice - technical reference useful for forensic paint science, focused on art works -DF]
  • Art, Biology, and Conservation: Biodeterioration in Works of Art, Robert J. Koestler et als. Eds., Metropolitan Museum of Art, 2003, ISBN 1-58839-107-8
  • Building Pathology, Deterioration, Diagnostics, and Intervention, Samuel Y. Harris, P.E., AIA, Esq., ISBN 0-471-33172-4, John Wiley & Sons, 2001 [General building science-DF - ** Particularly useful text **
  • Understanding Ventilation, John Bower, The Healthy House Institute, ISBN 0-9637156-5-8, 1995 [General building science-DF - ** Particularly useful text. Mr. Bower has retired from the field but his book continues to be important]
  • Dampness in buildings, Diagnosis, Treatment, Instruments, T.A. Oxley & E.G. Gobert, ISBN 0-408-01463-6, Butterworths, 1983-1987 [General building science-DF]
  • Home Reference Book - Carson DunlopThe Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.

    Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.

  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
    Building inspection education & report writing systems from Carson, Dunlop & Associates Ltd
  • Certainteed Weatherboard fiber cement siding and trim products - see certainteed.com/ or see certainteed.com/resources/sidingandtrimspecsheet.pdf
  • "Moisture Control in buildings: Putting Building Science in Green Building," Alex Wilson, Environmental Building News, Vol. 12. No. 5. [Good tutorial, "Moisture 101" outlining the physics of moisture movement in buildings and a good but incomplete list of general suggestions for moisture control - inadequate attention given to exterior conditions such as roof and surface drainage defects which are among the most-common sources of building moisture and water entry.--DJF]
  • Masonite Woodruf® Roofing or Masonite OmniWood® Siding Lawsuit Settlement Notice - PDF file
  • Paint Handbook: testing, selection, application, troubleshooting, surface preparation, etc., Guy E. Weismantel, Ed., McGraw Hill Book Company, 1981, ISBN-10: 0070690618, ISBN-13: 978-0070690615, [Excellent but a bit obsolete paint theory and practice, also a bit light on field investigation methods, out of print, available used-DF]
    How to select and apply the right paint or coating for any surface. The first major reference to help you choose the correct paint or other finish to do the job best on a particular surface exposed to a particular environment. Experts in the field give full advice on testing surface preparation, application, corrosion prevention, and troubleshooting. The handbook covers wood, metal, composites, and masonry, as well as marine applications and roof coatings. A ``must'' working tool for contractors, architects, engineers, specification writers, and paint dealers.
  • Paint and Surface Coatings, Theory and Practice, R. Lambourne & T.A. Strivens, Ed., Woodhead Publishing Ltd., William Andrew Publishing, 1999 ISBN 1-85573-348 X & 1-884207-73-1 [This is perhaps the leading reference on modern paints and coatings, but is a difficult text to obtain, and is a bit short on field investigation methods - DF]
    Provides a comprehensive reference source for all those in the paint industry, paint manufacturers and raw materials suppliers, undergraduate and postgraduate students, and industrial paint users. R. Lambourne was in the Research Department at ICI Paints Division and the Industrial Colloid Advisory Group, Birstol University, UK.
  • Seeing Through Paintings, Physical Examination in Art Historical Studies, Andrea Kirsh, Rustin S. Levenson, Materials in Fine Arts, 2000 ISBN 99-051835 [ forensic science, technical reference, focused on art works - DF]
  • Sealants, Durability of Building Sealants (RILEM Proceedings), J.C. Beech, A.T. Wolf, Spon Press; illustrated edition (1995), ISBN-10: 0419210709, ISBN-13: 978-0419210702
    This book presents the papers given at the RILEM Seminar held at the Building Research Establishment, Garston, UK in October 1994. The book provides an opportunity for researchers to review up-to-date progress towards the achievement of the objectives of the standardisation of laboratory techniques of sealants in the variety of service conditions to which they are exposed.
  • Soiling and Cleaning of Building Facades (RILEM Report), L.G.W. Verhoef (Editor), Routledge; 1 edition (November 3, 1988), ISBN-10: 0412306700, USBN-13: 978-0412306709
    The report of a comprehensive investigation by RILEM which examines all aspects of the cleaning of facades, subject to soiling by both biological and non-biological agencies. The contributors are international authorities working in this field giving essential advice to all those who need to know how to approach the problems connected with the soiling and cleaning of building facades.
  • Staining, Prevention of Premature Staining in New buildings, Phil Parnham, Taylor & Francis; 1996, ISBN-10: 0419171304, ISBN-13: 978-0419171300
    The appearance of ugly staining early in a buildings life, ruins an otherwise pleasing appearance, tarnishes the image of the owners and gives rise to costly refurbishment works. In this book Phil Parnham raises a number of questions that should be considered whenever a new building is being designed or built. These are: * why has staining become so prominent; * what causes premature staining; which parts of new buildings are likely to be affected; * how can it be avoided? By using a number of highly illustrated case studies, the author answers these questions and ends by suggesting measures that should be taken by all design and construction professionals to prevent premature staining.
  • "Weather-Resistive Barriers [copy on file as /interiors/Weather_Resistant_Barriers_DOE.pdf ] - ", how to select and install housewrap and other types of weather resistive barriers, U.S. DOE
  • ...