InspectAPedia.com InspectAPedia®

Question? Just ask us!

Google
InspectAPedia

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

  • HOME
  • AIR CONDITIONING
  • DAMAGE ASSESSMENT
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US



InspectAPedia ® Home

EXTERIORS of buildings

ADHESIVES, EXTERIOR CONSTRUCTION
AGE of a BUILDING - how to determine
ALGAE, FUNGUS, LICHENS, MOSS
ANIMAL ENTRY POINTS in buildings
ANIMAL ODORS IN buildings
ARCHITECTURE & BUILDING COMPONENT ID
ASBESTOS IDENTIFICATION IN buildings
ATTIC CONDENSATION CAUSE & CURE

BARK SIDE UP on DECKS & STEPS
BASEMENT WATERPROOFING
BEST CONSTRUCTION PRACTICES GUIDE
BRICK VENEER WALL Loose, Bulged
BRICK WALL DRAINAGE WEEP HOLES
BOOKSTORE - EXTERIORS

CARPENTER ANTS
CARPENTER BEES
CATCH BASINS
CAULK GUN TYPES, CHOICES
CAULKS & SEALANTS, EXTERIOR
CHIMNEY INSPECTION DIAGNOSIS REPAIR
COLUMNS & POSTS, DEFECTS
CONTAINER HOUSING
CONCRETE FOUNDATIONS
CONNECTORS, FASTENERS, TIES
CRAWL SPACES

DECK & PORCH CONSTRUCTION
DECK COLLAPSE Case Study
DECK FINISHES COATINGS PRESERVATIVES
DECK FLASHING LEAKS, ROT Case Study
DEFINITIONS of ENGINEERED WOOD OSB LVL etc
DRYWELLS, FRENCH DRAINS for FLAT SITES

EARTHQUAKE DAMAGED FOUNDATIONS
EIFS & STUCCO EXTERIORS
EXTERIOR WALL SIDING TRIM & FINISHES

FLASHING MEMBRANES PEEL & STICK
FLASHING for METAL ROOFS
FLASHING ROOF WALL DETAILS
FLASHING ROOF-WALL SNAFU
FLASHING SIDING DETAILS
FLASHING WALL DETAILS
FLASHING WINDOW DETAILS
FLASHING WOOD ROOF DETAILS
FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
FROST HEAVES, FOUNDATION, SLAB
FOOTING & FOUNDATION DRAINS
FOUNDATION WATERPROOFING
FRENCH DRAINS

GALVANIC SCALE & METAL CORROSION
GLUES ADHESIVES, EXTERIOR CONSTRUCTION
GRADING, DRAINAGE & SITE WORK
GUTTERS & DOWNSPOUTS

HEAT TAPES & CABLES on Roofs for Ice Dams
HOUSE PARTS, DEFINITIONS
HOUSEWRAP / SHEATHING WRAP
HOUSEWRAP INSTALLATION DETAILS
HOUSEWRAP PRODUCT CHOICES
HOUSEWRAP at SILLS, SOLES, TOP PLATES
HUMIDITY LEVEL TARGET

ICE DAM PREVENTION
INDOOR AIR QUALITY & HOUSE TIGHTNESS
INSECT INFESTATION / DAMAGE

KIT HOMES, Aladdin, Sears, Wards, Others

LEAD POISONING HAZARDS GUIDE
LEAD TEST KIT for HOME USE
LEED GREEN BUILDING CERTIFICATION
LOG HOME GUIDE
LIGHTNING PROTECTION

MOLD DETECTION & INSPECTION GUIDE

ODORS & SMELLS DIAGNOSIS & CURE

PAINT & STAIN GUIDE, EXTERIOR
PAINT FALURE, DIAGNOSIS, CURE, PREVENTION
PAINT FAILURE DICTIONARY
PAINT SURFACE PREPARATION
PAINTING MISTAKES
PORCHES & Sunrooms
PORCH CONSTRUCTION & SCREENING

RAILINGS, DECK & PORCH
RAILINGS, STAIRWAY
RETAINING WALL DESIGNS, TYPES, DAMAGE
RETAINING WALL GUARD RAILINGS
ROOF ARCHITECTURAL STYLES - PHOTO GUIDE
ROOF CLEANING RECOMMENDATIONS
ROOF COLOR RECOMMENDATIONS
ROOF DORMER TYPES - PHOTO GUIDE
ROOF VENTILATION SPECIFICATIONS
ROT RESISTANT LUMBER
ROT, TIMBER FRAME
ROT, TIMBER ASSESSMENT

SEARS KIT HOUSES
SEPTIC & CESSPOOL SAFETY
SHEATHING, Gypsum board
Sheathing Celotex Homasote & Other
SHEATHING, OSB
SHEATHING, Plywood
SHEATHING, FOIL FACED - VENTS

SIDING TYPES, INSTALLATION, DEFECTS
SINKHOLES, WARNING SIGNS
SOUND CONTROL in buildings
STAIN & BIODETERIORATION AGENT CATALOG
STAINS on & in BUILDINGS, CAUSES & CURES
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIN DIAGNOSIS on ROOFS
STAIN DIAGNOSIS on STONE
STAINS on INDOOR SURFACES: PHOTO GUIDE
STAIRS, RAILINGS, LANDINGS, RAMPS
STONE CLEANING METHODS
STONE VENEER WALLS
STRAW BALE CONSTRUCTION
STUCCO WAll FAILURES DUE TO WEATHER
STUCCO WALL METHODS & INSTALLATION
STUCCO OVER FOAM INSULATION
STUCCO PAINT FAILURES
SURFACE GRADING, SITE DRAINAGE

TERMITES
THERMAL EXPANSION of MATERIALS

TREES & SHRUBS, TRIM OFF BUILDING

TRIM, EXTERIOR CHOICES, INSTALLATION

VAPOR BARRIERS & CONDENSATION in BUILDINGS
VENTILATION in BUILDINGS
VINYL CHLORIDE HEALTH INFO
VINYL SIDING
VINYL Siding or PLASTIC Window ODORS
Volatile Organic Compounds VOCs

WALL CONSTRUCTION BARRIER vs CAVITY
WATER BARRIERS, EXTERIOR BUILDING
WATER ENTRY in buildings
WIND TURBINES & LIGHTNING
WINDOWS & DOORS
WINTERIZE A BUILDING

More Information

Photograph of deteriorated hardboard siding. Abitibi Price Hardboard Siding Class Action Contact Information
     

  • Abitibi hardboard siding (Abatibi-Price) class action litigation contact information.
    • ABTCO®/ABITIBI Abiti-Price Hardboard Siding Customer Support Information
  • SIDING HARDBOARD - separate article, all brands: Abatibi, ABTCO, Boise Cascade, Georgia Pacific, James Hardi HardiePlank, Louisiana Pacific, Masonite, Shakertown, Weyerhaeuser, Wolverine
    • ABATIBI Siding Claims - Abatibi hardboard siding failure information
    • BOISE CASCADE Siding Claims - separate article
    • JAMES HARDIE HardiePlank Siding
    • MASONITE Siding Claims - Masonite & other brands of hardboard siding failures and information; Colorlok siding paint
  • SIDING, FIBER CEMENT - separate article
  • Questions & Answers about hardboard siding failures, deterioration, warranties, and class action settlements: Abatibi
  • Questions & Answers about hardboard siding failures, claims, replacement, repair, painting, maintenance
  • References

Click to Show or Hide Related Topics

  • SIDING TYPES, INSTALLATION, DEFECTS - home
  • ALGAE, FUNGUS, LICHENS, MOSS
  • BRICK VENEER WALL Loose, Bulged
  • BRICK WALL DRAINAGE WEEP HOLES
  • CAULKS & SEALANTS, EXTERIOR
  • DECK FINISHES COATINGS PRESERVATIVES
  • EIFS & STUCCO EXTERIORS
  • FLASHING SIDING DETAILS
  • FLASHING WALL DETAILS
  • FLASHING WINDOW DETAILS
  • HOUSEWRAP / SHEATHING WRAP
  • HOUSEWRAP INSTALLATION
  • METAL LATH, PLASTER & STUCCO
  • MOISTURE CONTROL in BUILDINGS - home
  • PAINT & STAIN GUIDE, EXTERIOR
  • PAINT FALURE, DIAGNOSIS
  • SIDING, ALUMINUM
  • SIDING, ASBESTOS FIBER CEMENT
  • SIDING ASPHALT ROOF SHINGLES on WALLS
  • SIDING ASPHALT SHINGLE or SHEET
  • SIDING DAMAGE by SPLASHBACK
  • SIDING EIFS & STUCCO
  • SIDING, FIBER CEMENT
  • SIDING GAPS & CAULKING
  • SIDING HARDBOARD, ABATIBI, BOISE, MASONITE
  • SIDING HARDIEPLANK
  • SIDING, LOG
  • SIDING STEEL
  • SIDING VINYL
  • SIDING VINYL INSTALLATION
  • SIDING, WOOD PRODUCT CHOICES
  • SIDING, WOOD INSTALLATION
  • SIDING WOOD, FAILURES OVER FOAM BOARD
  • SIDING WOOD, FLASHING DETAILS
  • SIDING WOOD SHINGLE INSTALLATION
  • STAIN DIAGNOSIS on BUILDING EXTERIORS
  • STRUCTURAL DAMAGE PROBING
  • STUCCO WALL METHODS & INSTALLATION
  • STUCCO WAll FAILURES DUE TO WEATHER
  • STUCCO WALL METHODS & INSTALLATION
  • STUCCO OVER FOAM INSULATION
  • STUCCO PAINT FAILURES
  • TREES & SHRUBS, TRIM OFF BUILDING
  • TRIM, EXTERIOR CHOICES, INSTALLATION
  • VAPOR BARRIERS & CONDENSATION
  • WALL SIDING TRIM & FINISHES
  • WATER BARRIERS, EXTERIOR BUILDING
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

Hardboard siding failures: Abitibi™ (Abitibi-Price) siding was the subject of a class action suit associated with siding product failures. This building siding material is a hardboard siding wood product that deteriorates when exposed to weather, de-laminating and swelling. Repair of other than the most trivial damage of Abatibi hardboard siding is not feasible and siding replacement is generally in order.

Green links show where you are. © Copyright 2013 InspectAPedia.com, All Rights Reserved. Author Daniel Friedman.

Common Causes of Abatibi Price and other Hardboard Building Siding Failures

Hardboard siding failure (C) Carson Dunlop Associates

Abatibi Price™ hardboard siding is similar to products sold by Masonite Corp., Boise Cascade, and Georgia Pacific Corp,all of which experience failures of delamination, swelling, softening, and general deterioration when exposed to water and weather.

Also see our discussion at TRIM, EXTERIOR CHOICES, INSTALLATION

Our own field observations show that the siding material deteriorates fastest and most severely where:

  • The Abatibi hardboard siding (and similar products) has not been kept perfectly sealed and coated against water intrusion
  • The Abatibi hardboard siding has been damaged by cuts, nicks, or by counter-sunk siding nails that penetrated its top skin and were not kept perfectly sealed
  • The Abatibi hardboard siding has been exposed to high amounts of rain (weather side of buildings), or where it is exposed to roof spillage splash-up against siding, for example where building gutters and leaders are not installed or are not properly maintained
  • The end butt-joints of the siding were not kept sealed where exposed to weather
  • Water penetrates the siding and building wall at poorly-flashed or poorly-installed windows, doors, or other wall penetrations

How to Identify ABITIBI or other Hardboard Siding Products

Watch out: several hardboard siding products look alot alike from their exterior side, especially smooth products without a distinctive embossed pattern. To reliably identify the brand and manufacture date of a siding product you'll need historical data, bills and receipts, or you'll need to examine the reverse side of the siding for identifying markings such as those shown below at ABITIBI Siding Product Identification - Stamps & Markings.

Also see ABITIBI® Siding Back Codes below for help in dating the materials.

Attorney contact information for siding failures class action lawsuit

The law firm handling the case is Ezell & Sharbrough, P.O. 996, Mobile, AL 36601-0996 Phone: (334) 432-5297

If you have additional product failure examples you are welcome to contact us to provide additional field photos or information that may assist others in identifying and repairing siding failures.

ABTCO®/ABITIBI Abiti-Price Hardboard Siding Customer Support Information - Product Identification & Claims Information

Quoting from ABTCO/ABITIBI

Release No. 001-10-2000
ABTco contact
Gerry Soud: 704-948-1453

FOR IMMEDIATE RELEASE - May 8, 2000

ABTco, Inc. Reaches Preliminary Settlement
On Hardboard Siding Class Action Lawsuit

Charlotte, N.C. - ABTco, Inc. announced today that it has reached a tentative settlement agreement with plaintiffs in a class action suit regarding siding that it sold under the names Abitibi lap or panel siding and/or ABTco lap or panel siding.

ABTco has entered into this agreement with the primary goal of servicing its customers' concerns quickly and appropriately. A key provision of the settlement is a program to allow eligible claimants to recover the costs of repair or replacement of damaged hardboard siding.

"The program reflects the confidence of ABTco that its siding products will perform," said Joe Kastelic, president of ABTco Building Products. "If the product fails to perform, the purchasers will be compensated for repairs or replacement of damaged product, including both labor and materials, subject to agreed upon exclusions and deductions."

The Court has preliminarily approved the settlement; and it will hold a formal hearing on September 21, 2000 to consider whether the settlement should be given final approval as fair, reasonable and adequate. Class members who do not wish to participate in the settlement may opt-out by notifying class counsel and the notice administrator by July 31, 2000.

"Even though the overwhelming majority of product is performing, the settlement represents a statement of confidence that ABTco can and will stand behind all siding products that the company has sold," said Kastelic.

Homeowners, who believe they have damaged Abitibi/ABTco siding, or who have questions concerning the program details, are encouraged to contact the Abitibi/ABTco Customer Support Office at 800-549-4465. Customers can also visit the website at www.abtcoclaims.com.

Final ABITIBI Court Order Text

Readers wishing to read the 25 May 2000 final court order involving this case can see Thomas A. Fostger and Linda E. Foster, et al., v. ABTco, Inc. ABT Building Products Corp., ABITIBI-PRICE, Inc., and ABITIBI-PRICE Corp. Civil Action No. CV95-151-M entered in the Circuit Court of Choctaw County, Alabama - [large slow loading PDF file]

ABITIBI Siding Product Identification - Stamps & Markings

Below are images provided by ABTCO® to assist in identifying ABITBI building siding by noting the stamped or dot-matrix printed markings on the back side of the materials. Also see ABITIBI® Siding Back Codes below for help in dating the materials. Enlarged versions of these images can be seen by clicking on our copies below, or by visiting the ABTCO/ABTIBI website.


ABITIBI® Siding Back Codes

Old Code
Letter to represent the month -2 digit for the day -(in 70's,
1 digit for the year) -1 digit for shift -R (in 80's, 2 digits for the year) Example #1: A 01 51R -represents January 1, 1975 1st shift at Roaring River Example #2: B 02 62R -represents February 2, 1976 2nd shift at Roaring River Example #3: C 03 87 3 R -represents March 3, 1987 3rd shift at Roaring River Dot Matrix Code 2 digit for month -2 digit for day -2 digit for year -1 digit for shift -R Example: 05 20 971 R -represents May 20, 19971 st shift at Roaring River BACK CODE CONVERSION INFORMATION A B C D E F G H I J K L 1 2 3 4 5 6 7 8 9 10 11 1

Frequently Asked Questions (FAQs)

...

Ask a Question or Search InspectApedia

Questions & answers or comments about hardboard siding failures, deterioration, warranties, and class action settlements: Abatibi

Ask a Question or Enter Search Terms in the InspectApedia search box just below.

Technical Reviewers & References

Related Topics, found near the top of this page suggest articles closely related to this one.

  • ABTCO®/ABITIBI Abiti-Price Hardboard Siding Customer Support Information, web search 09/14/2010, original source: http://www.abtcoclaims.com/
  • ABTCO®/ABITIBI Abiti-Price Hardboard Siding Final Court Order, web search 09/14/2010, original source: http://www.abtcoclaims.com/images/abtcoorder.pdf

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson DunlopThe Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.

    Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.

  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
    Building inspection education & report writing systems from Carson, Dunlop & Associates Ltd
  • Allen, Edward and Joseph Iano. Fundamentals of Building Construction: Fourth Edition. Hoboken: John Wiley & Sons, 2004. pg. 91 [LVL lumber]
  • Analysis of Modern Paints, Thomas J.S. Learner, Research in Conservation, 2004 ISBN 0-89236-779-2 [Chemistry of modern paints, overview of analytical methods, pyrolysis-gas chromatography signatures of basic modern paints and their constituents, Fourier transform infrared spectroscopy for paint analysis, direct temperature-resolved mass spectrometry, and analysis in practice - technical reference useful for forensic paint science, focused on art works -DF]
  • APA - The Engineered Wood Association, 7011 So. 19th St., PO Box 11700, Tacoma WA 98411-0700, Tel: 253-565-7265. APA provides an HDO/MDO Plywood Product Guide that offers details about these products., provides an HDO/MDO Plywood Product Guide that offers details about these products. Product support help desk: 253-620-7400. Email the APA at help@apawood.org. Web search 09/13/2010, original source: http://www.pacificwoodlaminates.com/img/PDFs/PlywoodGuide.pdf
  • Art, Biology, and Conservation: Biodeterioration in Works of Art, Robert J. Koestler et als. Eds., Metropolitan Museum of Art, 2003, ISBN 1-58839-107-8
  • Building Pathology, Deterioration, Diagnostics, and Intervention, Samuel Y. Harris, P.E., AIA, Esq., ISBN 0-471-33172-4, John Wiley & Sons, 2001 [General building science-DF - ** Particularly useful text **
  • Certainteed Weatherboard fiber cement siding and trim products - see certainteed.com/ or see certainteed.com/resources/sidingandtrimspecsheet.pdf
  • Dream Porches and Sunrooms, Designing the Perfect Retreat [purchase at Amazon.com], Michael Snow, Collings Design, 2006, 176pp. ISBN 0-06-084728-x $35.00 U.S. or $46.50 Canada.
  • Understanding Ventilation, John Bower, The Healthy House Institute, ISBN 0-9637156-5-8, 1995 [General building science-DF - ** Particularly useful text. Mr. Bower has retired from the field but his book continues to be important]
  • Dampness in buildings, Diagnosis, Treatment, Instruments, T.A. Oxley & E.G. Gobert, ISBN 0-408-01463-6, Butterworths, 1983-1987 [General building science-DF]
  • Home Reference Book - Carson DunlopThe Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.

    Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.

  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
    Building inspection education & report writing systems from Carson, Dunlop & Associates Ltd
  • Certainteed Weatherboard fiber cement siding and trim products - see certainteed.com/ or see certainteed.com/resources/sidingandtrimspecsheet.pdf
  • "Flashing: the plain solution to leaky walls", Thomas E. Remmele, Manager, Technical Services, Sto Corporation, Building Standards, November/December 1999 p. 21-25.
  • Laminated Veneer Lumber, Overview of the Product, Manufacturing, Market, Department of Forest Products Marketing, wood-Based Panels Technology, Finland [PDF] web search 09/14/2010, original source: http://www.hochstrate.de/micha/finnland/reports/replvl.html
  • "Moisture Control in buildings: Putting Building Science in Green Building," Alex Wilson, Environmental Building News, Vol. 12. No. 5. [Good tutorial, "Moisture 101" outlining the physics of moisture movement in buildings and a good but incomplete list of general suggestions for moisture control - inadequate attention given to exterior conditions such as roof and surface drainage defects which are among the most-common sources of building moisture and water entry.--DJF]
  • Masonite Woodruf® Roofing or Masonite OmniWood® Siding Lawsuit Settlement Notice - PDF file
  • Paint Handbook: testing, selection, application, troubleshooting, surface preparation, etc., Guy E. Weismantel, Ed., McGraw Hill Book Company, 1981, ISBN-10: 0070690618, ISBN-13: 978-0070690615, [Excellent but a bit obsolete paint theory and practice, also a bit light on field investigation methods, out of print, available used-DF]
    How to select and apply the right paint or coating for any surface. The first major reference to help you choose the correct paint or other finish to do the job best on a particular surface exposed to a particular environment. Experts in the field give full advice on testing surface preparation, application, corrosion prevention, and troubleshooting. The handbook covers wood, metal, composites, and masonry, as well as marine applications and roof coatings. A ``must'' working tool for contractors, architects, engineers, specification writers, and paint dealers.
  • Paint and Surface Coatings, Theory and Practice, R. Lambourne & T.A. Strivens, Ed., Woodhead Publishing Ltd., William Andrew Publishing, 1999 ISBN 1-85573-348 X & 1-884207-73-1 [This is perhaps the leading reference on modern paints and coatings, but is a difficult text to obtain, and is a bit short on field investigation methods - DF]
    Provides a comprehensive reference source for all those in the paint industry, paint manufacturers and raw materials suppliers, undergraduate and postgraduate students, and industrial paint users. R. Lambourne was in the Research Department at ICI Paints Division and the Industrial Colloid Advisory Group, Birstol University, UK.
  • Sealants, Durability of Building Sealants (RILEM Proceedings), J.C. Beech, A.T. Wolf, Spon Press; illustrated edition (1995), ISBN-10: 0419210709, ISBN-13: 978-0419210702
    This book presents the papers given at the RILEM Seminar held at the Building Research Establishment, Garston, UK in October 1994. The book provides an opportunity for researchers to review up-to-date progress towards the achievement of the objectives of the standardisation of laboratory techniques of sealants in the variety of service conditions to which they are exposed.
  • Soiling and Cleaning of Building Facades (RILEM Report), L.G.W. Verhoef (Editor), Routledge; 1 edition (November 3, 1988), ISBN-10: 0412306700, USBN-13: 978-0412306709
    The report of a comprehensive investigation by RILEM which examines all aspects of the cleaning of facades, subject to soiling by both biological and non-biological agencies. The contributors are international authorities working in this field giving essential advice to all those who need to know how to approach the problems connected with the soiling and cleaning of building facades.
  • Staining, Prevention of Premature Staining in New buildings, Phil Parnham, Taylor & Francis; 1996, ISBN-10: 0419171304, ISBN-13: 978-0419171300
    The appearance of ugly staining early in a buildings life, ruins an otherwise pleasing appearance, tarnishes the image of the owners and gives rise to costly refurbishment works. In this book Phil Parnham raises a number of questions that should be considered whenever a new building is being designed or built. These are: * why has staining become so prominent; * what causes premature staining; which parts of new buildings are likely to be affected; * how can it be avoided? By using a number of highly illustrated case studies, the author answers these questions and ends by suggesting measures that should be taken by all design and construction professionals to prevent premature staining.
  • Sealants, Durability of Building Sealants (RILEM Proceedings), J.C. Beech, A.T. Wolf, Spon Press; illustrated edition (1995), ISBN-10: 0419210709, ISBN-13: 978-0419210702
    This book presents the papers given at the RILEM Seminar held at the Building Research Establishment, Garston, UK in October 1994. The book provides an opportunity for researchers to review up-to-date progress towards the achievement of the objectives of the standardisation of laboratory techniques of sealants in the variety of service conditions to which they are exposed.
  • Soiling and Cleaning of Building Facades (RILEM Report), L.G.W. Verhoef (Editor), Routledge; 1 edition (November 3, 1988), ISBN-10: 0412306700, USBN-13: 978-0412306709
    The report of a comprehensive investigation by RILEM which examines all aspects of the cleaning of facades, subject to soiling by both biological and non-biological agencies. The contributors are international authorities working in this field giving essential advice to all those who need to know how to approach the problems connected with the soiling and cleaning of building facades.
  • Staining, Prevention of Premature Staining in New buildings, Phil Parnham, Taylor & Francis; 1996, ISBN-10: 0419171304, ISBN-13: 978-0419171300
    The appearance of ugly staining early in a buildings life, ruins an otherwise pleasing appearance, tarnishes the image of the owners and gives rise to costly refurbishment works. In this book Phil Parnham raises a number of questions that should be considered whenever a new building is being designed or built. These are: * why has staining become so prominent; * what causes premature staining; which parts of new buildings are likely to be affected; * how can it be avoided? By using a number of highly illustrated case studies, the author answers these questions and ends by suggesting measures that should be taken by all design and construction professionals to prevent premature staining.
  • "Weather-Resistive Barriers [copy on file as /interiors/Weather_Resistant_Barriers_DOE.pdf ] - ", how to select and install housewrap and other types of weather resistive barriers, U.S. DOE
  • ...
HOME ABOUT CONTACT COPYING DESCRIPTION POLICIES PRINTING PRIVACY © 2013 Copyright InspectAPedia.com