  • EMF MEASUREMENT BASICS - CONTENTS: Guide to hiring an expert to measure electromagnetic field ("electrical field") strength for power lines, cell towers, radio towers, etc. ; What is an RF or EMF Exposure Hazard? How to make your own RF or EMF electromagnetic exposure and RF EMF field strength measurement survey. What kinds of radio frequency waves are there, what are EMF, RF, hertz, megahertz, MF, VHF, UHF, MHz, GHz, THz?What is the general procedure for making EMF Measurements - guide for consumers and property owners. How to measure EMF or RF electromagnetic field and radio frequency field exposure levels & field strengths
  • POST a QUESTION or READ FAQs about measuring EMF or RF electromagnetic field and radio frequency field exposure levels
  • REFERENCES
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

How to measure electromagnetic field exposure levels:

This article on EMF measurements explains the basics of how we can reliably measure the level of electromagnetic radiation or electromagnetic fields (EMF).



Green links show where you are. © Copyright 2017 InspectApedia.com, All Rights Reserved.

The Basics of Measuring Electromagnetic Field EMF Exposure Levels

Electrical power transformer on a utility pole in the U.S.  (C) Daniel FriedmanOur page top photo shows a Safeco™ electromagnetic field measuring instrument. This the EMF readings that this instrument obtains are position sensitive - where you point it makes a difference even in the same spot.

As we explain at EMF RF FIELD & FREQUENCY DEFINITIONS, there is a wide range of electrical field types when arranged by frequency, from lower frequencies emitted by electrical power lines (EMF), AM and FM radio frequencies (radio towers - MF and HF or VHF), cell phones, FM and TV radio frequencies (UHF) and others in the electromagnetic spectrum.

Question: Can I Hire You to Make Site Measurements of Electrical Fields?

I wonder if you test the RF and magnetic fields given off from cell phone towers. We have recently moved into a building that I just found out that the building owners have placed cell phone towers on the roof. I am worried since I have a baby. Please let me know if you service. A.F. - New York City.

Reply:

We no longer offer on-site investigation services for measuring electromagnetic fields, though certainly you can hire local experts who can provide that service, have the necessary equipment, and are trained in its use. But before hiring someone to measure magnetic fields, here are a few things to consider:

First, if your object is personal safety for building occupants, there are other immediate potential hazards that should be attended first, as the absolute risk from other hazards can be very significant. Explicit, competent, documented electrical field strength measurements are more reliable than unsubstantiated opinions based on visual observation and fear.

No one should be cavalier about people's health, but keeping risks in perspective serves everyone and helps assure that building owners, occupants, parents focus on the big risks first. Review basic building safety items such as

Guide to Hiring Someone to Measure Electromagnetic Field Strengths: EMF

If a building owner or occupant is concerned about EMF or other electromagnetic field strength levels at a property (power lines, cell phone towers, radio transmitter towers, other sources), the local power company or other service providers may be willing to perform site measurements at no charge.

Independent experts provide thorough site profiles for fees ranging from $500. to $2,500. and some include extensive consulting which helps protect realtors from future liabilities and can calm inappropriately frightened buyers or sellers. But below you will read why for many circumstances we do not recommend this approach.

For electromagnetic field testing, whether it is UHF (cell phones), VHF and HF (radio towers), or EMF (power lines), and particularly for EMF testing, unless there is a legal issue that requires that the inspection and test be performed by an independent expert, you may prefer to purchase some equipment and following the procedures we’ve outlined for making an on-site survey of electrical field strengths yourself.

Particularly because the strength of electrical fields can vary enormously depending on the level of use of the emitting system, there is a risk that you hire someone at a high cost whose measurement results by no means tell you the average nor long term level of electrical field exposure at that location.

For a thoughtful, informed person who will read, it’s not technically difficult to use most electrical field measurement devices, and there are these advantages:

Hiring an EMF RF consultant compared with doing it yourself

Our own personal ethical views, combined with even the most basic technical understanding of issues around RF and EMF hazards make us very reluctant to recommend hiring an "expert" perform EMF and RF field investigations for homeowners or apartment dwellers in most circumstances. Why?

  1. Signal strength can be enormously variable at a given location, depending in the case of EMF on the actual current load on the
    power transmission lines, and in the case of high frequency RF, on the transmission activity, antenna direction, and other factors.
    As a result, momentary or single-point-in-time measurements can be quite misleading.

    See EMF Procedures & Causes of EMF Measurement Error & Variation.
  2. Inappropriate expense? On every environmentally fearful topic a quick industry is bred of people who are poorly trained, sometimes unethical, but who prey on consumer fear to become wealthy - the behind the scenes comments from some of these folks can be very disturbing. Professionals are obligated to proceed responsibly in accepting field investigation assignments, respecting both the client's physical health and their financial impacts as well.

    Instead of contacting us with a request to perform EMF Electromagnetic or RF Radio Frequency Field Strength measurements, in most cases it is more economical and convenient for a property owner to purchase their own instrument, making measurements under varying conditions. In this series of articles we describe how to make measurements using a consistent approach and using good documentation.

    See Recommended EMF Measurement Procedure for details of how to collect EMF measurement data.

Three Approaches to Measuring RF and EMF Hazards at Properties

For at least these reasons, we recommend one several different different approaches, among which you should choose, or if you can
describe to us a further viewpoint, Contact Us.

  1. EMF RF Exposure Litigation: If you are involved in or anticipate litigation, then indeed it is appropriate to have a neutral third party professional make a site investigation and to document conditions there.
  2. Accurate, longer term EMF or RF measurements at low cost: If #1 does not apply, then a more informed site risk profile is one that would collect measurements over time, under different conditions of load, season of the year, transmission activity, supplemented by basic research to identify the particular source nearby and its character.

    For example, if it is a power transmission line, the maximum KVA rating of the line and its distance from the building of concern are of paramount interest, even if an instantaneous measurement gives low results. Rather than pay an independent $1800. U.S. or more to perform a single site survey, purchase the appropriate test instruments and make your own measurements, over time.

    To assist in this procedure we have provided a series of articles organized at EMF SURVEY PROCEDURE - Details.

    Following good procedure and using instruments properly are two steps towards making accurate, repeatable EMF measurements.

    But because the signal transmission for RF sources such as radio, TV, or cell towers, the load on a power transmission line is not under control of an individual property owner, and because the EMF strength varies as the power transmission line load varies, it is important to have an idea of that condition as well when attempting to characterize EMF exposure at a specific location.

    In contrast, EMF measurements are quite accurate and repeatable at other EMF sources such as close to electrical appliances and service entry cables.

    At Evaluation of Low-Cost EMF Instruments we list a number of tools that are easy to use, but whose accuracy also depends on the actual measurement procedure - where and how measurements are obtained, which is what we discuss in the EMF Survey Procedure article above, and for which we also provide example field data collection sheets.

    Approach #2 is likely to cost just a few hundred dollars U.S. at most, and allows longer and more extensive measurements.
  3. If there is a special concern at a property, such as health complaints that appear to be building or site-related but that need
    further investigation, then bringing an expert to the site is indeed more likely to be ethically and cost-justified.

Guide to Making Your Own Electromagnetic Field Strength EMF / RF Measurements

TriField EMF MeterIf you're simply curious about finding and measuring local EMF strengths around a home, an alternative might be to simply purchase an inexpensive electromagnetic field strength measuring device.

But before dashing about recording numbers, it is important to understand both the peculiarities of EMF field strength meters and the peculiarities of the size, shape, pattern, and time variation of electromagnetic fields themselves.

Suggestions for using some sample EMF measuring instruments and a discussion of the sources of error and variation in EMF measurements are discussed in more detail at our Electromagnetic Radiation Field EMF SURVEY Procedure

At Evaluation of Low-Cost EMF Instruments such as the TriField EMF and RF meter shown here we show several different types of EMF measuring instruments and discuss their properties.

Please do not contact us to buy equipment. We do not sell anything. To do so would be a conflict of interest for this website.

These devices are readily available from many electrical equipment and home inspection equipment suppliers.

Instead of contacting us with a request to perform EMF Electromagnetic or RF Radio Frequency Field Strength measurements, in most cases it is more economical and convenient for a property owner to purchase their own instrument, making measurements under varying conditions. In this series of articles we describe how to make measurements using a consistent approach and using good documentation.

See Recommended EMF Measurement Procedure for details of how to collect EMF measurement data.

Following good procedure and using instruments properly are two steps towards making accurate, repeatable RF (radio frequency) or EMF (electromagnetic field) measurements.

But because the transmission from a cell tower, television tower, or the load on a power transmission line is not under control of an individual property owner, and because the RF or EMF strength varies as the power transmission line load varies, it is important to have an idea of that condition as well when attempting to characterize EMF exposure at a specific location.

In contrast, RF or EMF measurements are quite accurate and repeatable at other EMF sources such as close to electrical appliances and service entry cables.

Do not contact us with a request buy RF or EMF measuring equipment. These devices are readily available from many electrical equipment and home inspection equipment suppliers.

See Evaluation of Low-Cost EMF Instruments This article describes several low-cost and reasonably accurate EMF measurement devices that are readily available.

See Radio Frequency RF Detection Meters This article describes several low-cost and accurate radio frequency or RF detection and measurement devices suitable for radio, TV, cellphone, microwave, and similar signals.

Readers who need to measure EMF themselves or who intend to hire someone to do so should also be sure to review our more detailed EMF measurement procedures
at Electromagnetic Radiation Field EMF SURVEY Procedure and also

see EMF Survey Worksheet - Excel Spreadsheet

and EMF Survey Worksheet - Sample & Explanation. or select a topic from closely-related articles below, or see our complete INDEX to RELATED ARTICLES below.

Articles About Electromagnetic Fields, Hazards, Measurements

...


Continue reading at EMF MEASUREMENT STEP BY STEP or select a topic from closely-related articles below, or see our complete INDEX to RELATED ARTICLES below.

Suggested citation for this web page

EMF MEASUREMENT PROCEDURES at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

INDEX to RELATED ARTICLES: ARTICLE INDEX to BUILDING ENVIRONMENT

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia


...

Frequently Asked Questions (FAQs)

Click to Show or Hide FAQs

Ask a Question or Search InspectApedia

Questions & answers or comments about measuring EMF or RF electromagnetic field and radio frequency field exposure levels.

Use the "Click to Show or Hide FAQs" link just above to see recently-posted questions, comments, replies, try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Comment Box is loading comments...

Technical Reviewers & References

Click to Show or Hide Citations & References

Publisher's Google+ Page by Daniel Friedman